Data sheet Single phase Energy meter with integrated S-Bus interface

Similar documents
Controls Division. Mounting. Mounting Terminal connections main circuit. Terminal connections control circuit. Insulation characteristics

Single-phase Energy meter

Electrical Energy Meter with integrated Serial Modbus interface

EEM230-D-M. Energy meters. Electrical Energy Meter with integrated M-Bus interface

EEM230-D-M. Energy meters. Electrical Energy Meter with integrated M-Bus interface

Singlephase Energy meter with M-Bus interface

Assembly. Assembly. Connections Main circuit. Connections Control circuit. Insulation properties

3-phase energy meters with M-Bus interface

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

SDM120C. Single-Phase Energy Meters. RS485 Modbus RTU. User Manual V1.0

User Manual V2.6. SDM120-Modbus. Single-Phase Multifunction DIN rail Meter

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Installation and Operating Instructions

Energy Management Energy Transducer Type ET112

SPM91 DIN Rail Single Phase Energy Meter Installation & Operation Manual V1.0

RESIDENTIAL ZMF100AC, ZMF100AB, ZFF100 TECHNICAL DATA. IEC-specific data Current Base current I b. Measurement Accuracy. Measurement Behaviour

User Manual V1.1. SDM120-Modbus(mV) Single-Phase Multifunction DIN rail Meter

COUNTIS E05. Single-phase energy meter Direct - 40 A M-BUS. Instruction manual. en/countis-e0x

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

Jiaxing Eastron Electronic Instruments Co.,Ltd. Tel: Fax:

Energy Management BUS Adapter Type VMU-B 01

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

MIC-2 MKII, Multi-instrument DATA SHEET

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

SDM530-Modbus USER MANUAL 2015 V1.5. Three Phase Multi-function DIN rail meter. Eastron SDM530-Modbus User Manual

E350 series 2. ZCF100Ax/Cx s2. Technical Data. Electricity Meters IEC/MID Residential

EM270. Multi-channel power analyzer. Benefits. Description

SDM530CT-Modbus USER MANUAL 2015 V1.6. Three Phase Multi-function DIN rail meter. Eastron SDM530CT-Modbus User Manual

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

EM271. Multi-channel power analyzer. Benefits. Description

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

U niversal Measuring Device NEW! UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs.

USER MANUAL 2012 V1.1

E350 series 2. Electricity Meters IEC/MID Residential. ZxF100Ax/Cx. Technical Data

TU531, TU532 Terminal Unit

DIN Rail Smart Meter for Single and Three Phase Electrical Systems

LED Driver Linear / area fixed output

Energy Management BUS Adapter Type VMU-B

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

LED Driver Linear / area fixed output

Features and Benefits. Certifications

DI572 Digital Input Module

FL MC 2000E (SM40) LC

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

MIC-2 Multi-instrument DATA SHEET

SDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

Smart Energy Meter. Benefits and Main Features. User Manual Revision English OB (100)A

AI561 Analog Input Module

Multifunction Transducer MT440

AB Axis Industries. Use

LED Driver Linear / area fixed output

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

4 Is this model available for special primary current and special primary voltage?

AO523 Analog Input Module

TF501, TF521 Terminal Bases

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

DI561 Digital Input Module

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Technical information

Manual. Q.PS-PEL-240x 24 VDC Power Supply Unit. Document ; Version ENG

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

General information. Display. Supply voltage. Input current. Encoder supply. Output current

LED Driver Compact fixed output

AI531 Analog Input Module

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

User Manual V1.0 SDM230-DR. Single-Phase Two Module DIN rail Meters

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Installation and User Guide

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Power Meter PowerMonitor 500

LED Driver Compact fixed output

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

General information. Display. Supply voltage

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

General information. Display. Supply voltage. Input current. Encoder supply. Output current

PADPULS2 M-BUS Pulse Input Modules

Electronic timer CT-ERD.12

ISOMETER isoev425/isoev425hc with coupling device AGH420

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Digital input/output modules. The digital input/output modules The economic interfaces to the process

MINI-PS AC/10-15DC/8

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

DC561, digital input/output module,

Transcription:

Data sheet Single phase Energy meter with integrated S-Bus interface Controls Division Bus ALD1 Energy meters with an integrated S-Bus interface allow direct reading of all relevant data, such as energy (Total and partial), current, voltage, active and reactive power and cos φ. Main features: Single-phase energy meter, 230 VAC 50 Hz Direct measurement up to 32 A Display of active power, voltage and current S-Bus Interface to query the data Reactive power and cosφ available through interface Up to 254 meter can be connected to the S-Bus Interface 7-digit display Lead seal possible with cap as accessory Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21 Order Number Standard Version: ALD1D5FS00A2A00 MID Version: ALD1D5FS00A3A00 Technical data Precision class Operating voltage Reference/ measurement current Starting/minimum current Power consumption B according to EN50470-3, class 1 according to IEC62053-21 230 VAC, 50 Hz Tolerance 20 % /+15 % I ref = 5 A, I max = 32 A I st = 20 ma, I min = 0.25 A Active 0.4 W per phase Counting range 00 000.00 99 999.99 100 000.0 999 999.9 Display LCD backlit, digits 5 mm high Pulses per kwh LC-Display 2000 Imp./kWh Mounting Mounting Terminal connections main circuit Terminal connections control circuit Insulation characteristics On 35 mm rail, according to EN60715TH35 Conductor cross-section max. 6 mm 2, screwdriver Pozidrive no. 1, slot no.1 Breakaway torque: 1,2 Nm Conductor cross-section max. 2.5 mm 2, screwdriver Pozidrive no. 0, or slot no.1 Breakaway torque: 0,5 Nm 4 kv/50 Hz test according to VDE0435 for Energy Meter part 6 kv 1.2/50 µs surge voltage according to IEC255-4 2 kv / 50 Hz test according to VDE0435 for Interface device protection class II Ambient temperature 25 +55 C Storage temperature 30 +85 C Relative humidity EMC/interference immunity 95 % at 25 +40 C, without condensation Surge voltage according to IEC61000-4-5 at main circuit, 4 kv at S-Bus interface, 1 kv Burst voltage according to IEC61000-4-4, at main circuit 4 kv at S-Bus interface 1 kv ESD according to IEC61000-4-2, contact 8 kv, air 15 kv

Dimension diagram Structure Display elements, direct measurement T total (kwh) Indicates the total consumption T part (kwh) Indicates the partial consumption. This value can be reset P (kw) Indicates the instantaneous power U (V) Indicates the voltage I (A) Indicates the current 2000 pulses/kwh Pulsates according to the amount of used power. Data sheet Saia 2 ALD1, Single-phase energy meter with integrated Serial S-Net interface

Menu to display the value on LCD Start T total Total consumption Tpart. Partial consumption > 3 s > 3 s P Instantaneous power U Voltage > 3 s I Current > 2 s 20 s Back to Start Back to Start Data sheet Saia ALD1, Single-phase energy meter with integrated Serial S-Net interface 3

Wirings Diagram 5560 N Saia S-Bus, pair of wires, twisted max. 1200 m /D D Technical data S-Bus Bus system Saia S-Bus Transmission rate 2 400-4 800-9600-19 200-38 400-57 600-115 200. The transmission Baud rate is automatically detected Transmission mode Data Bus length (max.) 1200 m (without repeater) Response time: (to system response) Write: up to 60 ms Read: up to 60 ms The communication is ready 30 s after the power on The use of energy meter in bus with intensive communication could reduce the performance of the bus Refresh time for the data is 5 s. For this reason one energy meter should be not polled faster as 5 s 254 devices could be connected to the S-Bus. Over 128 devices, a repeater should be used The interface don t have a terminal resistor, this should be provided external For a description of the used registers please look at the register page Data transmission Only «read/write» register instructions are recognized Only one register can be written at a time The device will respond «NAK if more than 1 register is written Up to 10 Registers could be read at a time The device will respond «NAK if more than 10 registers are read The device will not respond to any unknown query The device has a voltage monitoring system. In case of voltage loss, registers are stored in EEPROM (transmission rate) etc. Change the S-Bus address direct on device In the menu, go for «U» Push long ( 3 sec) «SBUS-ADR» Push short S-Bus address +1, push long S-Bus address +10 Once the desired address is selected wait, to validate, till the root menu to come back 4 Data sheet Saia ALD1, Single-phase energy meter with integrated Serial S-Net interface

Register The following registers are available. The registers 4, 10, 11, 12, 18, 19, 22 and 23 are not used and will give always the answer 0. R Read Write Description Unit 0 X Firmware-Version Ex: «11» = FW 1.1 1 X S-Bus com. number of supported registers will give «29» 2 X S-Bus com. number of supported flags will give «0» 3 X Baudrate BPS 4 X Not used will give a «0» 5 X Type/ASN function will give «ALD1» 6 X Type/ASN function will give «D5FS» 7 X Type/ASN function will give «00A» 8 X Type/ASN function will give 9 X HW Vers. Modif Ex: «11» = FW 1.1 10 X Not used will give a «0» 11 X Not used will give a «0» 12 X Not used will give a «0» 13 X Serial number 14 X Status/Protect 15 X S-Bus timeout ms «0» = no Problem «1» = Problem with last communication request 16 X X S-Bus address 17 X Error flags 0 : No error 1 : Error 18 X Not used will give «0» 19 X Not used will give «0» 20 X Counter energy total 21 X X Counter energy partial Any written value reset the counter 22 X Not used will give «0» 23 X Not used will give «0» 24 X Effective voltage 25 X Effective current 26 X Effective active power 27 X Effective reactive power 28 X cos phi phase 10-2 kwh. (multiplier 0,01) Ex: 00912351= 009123,51 kwh 10-2 kwh. (multiplier 0,01) Ex: 00912351= 009123,51 kwh V Ex: 230 = 230 V 10-1 A (multiplier 0,1) Ex: 314 = 31,4 A 10-2 kw (multiplier 0,01) Ex: 1545 = 15,45 kw 10-2 kva (multiplier 0,01) Ex: 1545 = 15,45 kvar 10-2 (multiplier 0.01) Ex: 67 = 0.67 Data sheet Saia ALD1, Single-phase energy meter with integrated Serial S-Net interface 5

Contact Switzerland and international Saia-Burgess Controls AG Bahnhofstrasse 18 CH-3280 Murten / Switzerland T +41 (0)26 672 72 72 F +41 (0)26 672 74 99 pcd@saia-burgess.com Supplied by: Product Support, Technical reference website: www.saia-support.ch P+P26/523 EN03 12. 2012 Subject to changes to technical details and figures.