PMT 221A High Impedance Passive Probe. Instruction Manual

Similar documents
PMT 201A-RO High Impedance Passive Probe. Instruction Manual

PML 791-RO Low-Z Passive Probe. Instruction Manual

designed for OMICRON Lab PML 111O High Impedance Passive Probe Instruction Manual

38 MHz Passive Voltage Probe R&S RT-ZP1X

TETRIS 2500 High Impedance Active Probe. Instruction Manual

TA MHz Oscilloscope Probe USER S GUIDE

TETRIS 1000 / High Impedance Active Probe Order-No: Features:

KHT 6000 C HV-Probe Calibrator. Instruction Manual

Instruction Manual LeCroy PP007-WR / PP007-WS Passive Probe

LeCroy PP009 Passive Probe Instruction Manual

LeCroy PP008 Passive Probe Instruction Manual

PP007-WR-1 PP007-WR-2 PP007-WS-1 PP007-WS-2. Operator s Manual. PP007 Passive Probe

N2870A Series Passive Probes and Accessories

N2870A Series Passive Probes and Accessories

Keysight N2870A Series Passive Probes and Accessories. Data Sheet

Instructions. P MHz 10X Passive Probe

P5200A Series High Voltage Differential Probes. Installation and Safety Instructions & Product Documentation CD

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

User's Guide. Extech AM A AC Analog Clamp Meter

TCP305A & TCP312A AC/DC Current Probes Instructions

Mini Digital Multimeter

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User's Guide. MiniTec TM Series Model MN25 MultiMeter

9040/9040UK. Users Manual. Phase Rotation Indicator

HV-CS kv Edge Mount Triaxial Jack

DC 100 A Current Probe

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

MTP INSTRUCTION MANUAL

custom test and measuring environments.

User s Guide. 600A AC Clamp Meter. Model 38387

User's Guide. Phase Sequence and Motor Rotation Tester Model

DS1000B Series Digital Oscilloscope

TVAC25100 TVAC25110 User manual

Instructions. P GHz 10X Active Probe

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

ELV12 Series. Instruction Manual

Mini Digital Multimeter

Mini Digital Multimeter

GPS Synchronization Module

50 Amp AC/DC Current Probe PA-655 INSTRUCTION MANUAL 安培交流 / 直流電流探測鉗. DC 500KHz. 5mA 50A.

DC 100 A Current Probe

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

ETHOS Auto Ranging Digital Multimeter

Mini Digital Multimeter Model MN15. User's Guide

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

Automated Tuner System Power Distribution Hub

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

DM3058/DM3058E Digital Multimeter

OX 5022-CK OX 5042-CK

Quick Start/Installation Guide

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

PCT2000. User Manual. Precision current transducer 2000 A

User Guide True RMS Multimeter Extech EX205T

VDS Series PC Oscilloscopes Quick Guide

CLAMP MULTIMETER METRACLIP 85 ENGLISH. Start Guide

CAEN. Electronic Instrumentation. NIM slot 5U CERN Compliant NIM Crate. Rev July Tools for Discovery

1103 Power Supply (SN B and Above) Instruction Manual

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

PRODUCT SPECIFICATION. PC Board Relays. Series.

700 Series 200 Amp Clamp Meters

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Line Impedance Stabilization Network (LISN)

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

Autoranging Mini Multimeter Model MN16A

User's Guide. Digital Multimeter. Model MN42

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

Ultra Slim Relays 24

AC/DC Current Probe Model SL206 USER MANUAL

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

P344 4-lane MIPI DPhy Stimulus Generator Data Sheet & User Manual. January Rev 1.31

AC/DC Current Probe Model SL201

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

NX8 Pocket Toner Users Guide

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Variable-Speed Vortex Mixer

Model 7701 Multiplexer Module

2016 SIGLENT TECHNOLOGIES CO.,LTD

Agilent U2941A Parametric Test Fixture

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

Model 2380 Rack-Mount Kit

Agilent 16442B. User s Guide. Agilent Technologies

ENGLISH. User manual.

Autoranging Mini Multimeter

Keysight 42941A Impedance Probe Kit

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Pure Sinewave Inverter

DVI Extender over Single CAT5 Mini SET

Model A Mini AC/DC Clamp Meter. User's Guide

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Conductive Level Controller

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

Transcription:

PMT 221A High Impedance Passive Probe Instruction Manual

Copyright 2011 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications are subject to change without notice. Manufacturer PMK Mess- und Kommunikationstechnik GmbH Königsteiner Str. 98 65812 Bad Soden, Germany Internet: www.pmk-gmbh.com Tel: +49 (0) 6196 5927-930 E-Mail: sales@pmk-gmbh.com Fax: +49 (0) 6196 5927-939 service@pmk-gmbh.com Warranty PMK GmbH warrants this oscilloscope accessory for normal use and operation within specifications for a period of two (2) years from date of shipment and will repair or replace any defective product which was not damaged by negligence, misuse, improper installation, accident or unauthorized repair or modification by the buyer. This warranty is applicable only to defects due to material or workmanship. PMK GmbH disclaim any other implied warranties of merchantability or fitness for a particular purpose. PMK GmbH will not be liable for any indirect, special, incidental, or consequential damages (including damages for loss of profits, loss of business, loss of use or data, interruption of business and the like), even if PMK GmbH has been advised of the possibility of such damages arising from any defect or error in this manual or product. 2

Declaration of Conformity (EC conformity marking) The manufacturer declares the conformity of this product with the actual required safety standards in accordance with the Low Voltage Directive (LVD) 2006/95/EC: CEI/IEC 61010-031:2008 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test WEEE/ RoHS Directives (EC conformity marking) This electronic product is classified within the WEEE/ RoHS* category list as monitoring and control equipment (category 9). Category 9 products are exempted from the restrictions under the scope of the RoHS directive. Your help and efforts are required to protect and keep clean our environment. Therefore return this electronic product at the end of its life either to the manufacturer or take care of separate WEEE collection and professional WEEE treatment yourself. Do not dispose as unsorted municipal waste! * EC Directives: WEEE Directive 2002/96/EC - Waste Electrical and Electronic Equipment RoHS Directive 2002/95/EC - Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment 3

IEC Measurement Categories Definitions and Examples (Clause 6.5.2) Measurement Category I Definition: Measurement category I is for measurements performed on circuits not directly connected to a mains supply. Examples: Measurements in circuits not derived from a mains supply and specially protected ( internal ) circuits derived from a mains supply. In the latter case, transient stresses are variable; for that reason it is required that the transient withstand capability of the equipment is made known to the user. Measurement Category II Definition: Measurement category II is for measurements performed CAT II on circuits directly connected to the low voltage installation. Examples: Household appliances, portable tools and similar equipment. IEC Pollution Degrees Definitions (Clause 3.5.6 ) Pollution Degree 2 Only- non conductive POLLUTION. Occasionally, however, a temporary conductivity caused by condensation must be accepted. IEC Safety Symbols The following symbols may appear on the product or in this instruction manual: Caution, risk of danger. Refer to manual. Caution, risk of electric shock. Earth (ground) TERMINAL. 4

Safety Information To avoid personal injury and to prevent fire or damage to this product or products connected to it, review and comply with the following safety precautions. Be aware that if you use this probe assembly in a manner not specified the protection this product provides may be impaired. Only qualified personnel should use this probe assembly. Use only grounded instruments. Do not connect the probe ground lead to a potential other than earth ground. Always make sure the probe and the measurement instrument are grounded properly. Connect and disconnect properly. Connect the probe output to the measurement instrument and connect the ground lead to earth ground before connecting the probe to the circuit under test. Disconnect the probe input and the probe ground lead from the circuit under test before disconnecting the probe from the measurement instrument. Observe probe and probe accessory ratings. Do not apply any electrical potential to the probe input which exceeds the maximum ratings of the probe or the accessories connected to it. In a combination always the lower rating / measurement category applies to both probe and accessories connected to it. Make sure to comply with the voltage versus frequency derating curve on page 6. Keep away from live circuits. Avoid open circuitry. Do not touch connections or components when power is present. Do not operate with suspected failures. Refer to qualified service personnel. Indoor use only. Do not operate in wet/damp environment. Keep product surfaces dry and clean. 5

Specifications Specifications that are not defined to be guaranteed are typical and are published as general information to the user. The instrument should have warmed-up for at least 20 minutes and the environmental conditions should not exceed the probe's specified limits. Electrical Specifications Attenuation Ratio (swichtable) (1) 1:1 10:1 ± 2 % at DC (at 10:1) Voltage Coefficient - 0.0025 %/V (typical) Probe Bandwidth (2) 30 MHz 250 MHz (-3 db) Probe Risetime 12 nsec 1.4 nsec (10 % - 90 %) (typical) Maximum Rated Input Voltage (3) Measurement category I: - 400 V rms 1250 V transient overvoltage Measurement category II: 55 V rms CAT II 300 V rms CAT II Pollution Degree (3) 2 Voltage Derating Typical voltage derating (switched to 10:1) Measurement category I Note that the max. input voltage rating of the probe decreases as the frequency of the applied signal increases. Amplitude AC rms [V]sinus 400 300 200 100 0 100K 1M 10M 100M 1G Frequency [Hz] (1) Connected to oscilloscope with an input impedance of 1 MΩ ± 1 %. (2) at 15 pf input capacitance of the measuring instrument. (3) As defined in IEC 61010-031. See definitions explained on page 4. 6

Specifications Electrical Characteristics Attenuation Ratio 1:1 10:1 Input Resistance (System) - 10 MΩ ± 1 % Input Capacitance (System) 80 pf incl. Osci 13 pf (typical) Compensation Range - 10 pf - 35 pf (typical) Input Coupling of the Measuring Instrument 1 MΩ AC / DC 1 MΩ AC / DC Input Impedance 100M Typical input impedance (switched to 10:1) Note that the input impedance of the probe decreases as the frequency of the applied signal increases. Z [Ohm] 10M 1M 100K 10K 1K 100 10 10 100 1K 10K 100K 1M 10M 100M 1G Frequency[Hz] Mechanical Characteristics Weight (probe only) Cable Length Probe Tip Diameter 55 g 1.2 m 5 mm Environmental specifications Altitude operating up to 2000 m non-operating up to 15000 m Temperature Range operating 0 C to +50 C non-operating -40 C to +71 C Maximum Relative Humidity operating 80 % relative humidity for temperatures up to +31 C, decreasing linearly to 40 % at +50 C 7

Adjustment Procedures The probe can be adjusted for low frequency (LF) compensation and for high frequency (HF) compensation. LF Compensation LF needs to be adjusted when the probe is connected to the oscilloscope input the first time. LF compensation matches the probes cable capacitance to the oscilloscope input capacitance. LF compensation is performed by connecting the probe to the CAL output on the oscilloscope front panel and adjusting the LF compensation trimmer to optimum square wave response. For clarification see below figures. undercompensated optimum overcompensated HF Compensation HF needs to be adjusted when the probe is connected to the scope input the first time.hf adjustment is performed by connecting the probe to a rectangular wave generator with a fast rise time. Adjust the trimmer for optimum square wave response. optimum LF Compensation HF Compensation 8

Handling Handle with care especially when fitted with the extra thin and sharp spring contact tip to avoid any injury. Note that the probe cable is a sensitive part of the probe. Do not damage through excessive bending or pulling. Avoid mechanical shock to this product in general to guarantee accurate performance and protection. Maintenance Cleaning To clean the exterior of the probe use a soft cloth moistened with either distillated water or isopropyl alcohol. Before use allow the probe to dry completely. Changing the Probe Tip To change the probe tip use pliers to grip and pull it carefully straight out of its contact socket, along the axis of the probe. Do not grip the white plastic insulator or the housing with pliers, because the tip could be squeezed and cannot be removed and respectively the probe could be damaged. If the probe tip is removed, the new tip can be inserted with pliers into the contact socket, along the axis of the probe. In order to insert the probe tip completely into the housing, press the probe tip against a hard surface carefully. Use pliers to grip and pull the probe tip carefully out of its contact socket. Do not grip the white plastic insulator or the probe housing with pliers. 9

Probe Accessories 018-292-063 IC-Cap 5.0 0.8 mm pitch; gray 018-292-064 IC-Cap 5.0 1.0 mm pitch; brown 018-292-065 IC-Cap 5.0 1.27 mm pitch; black 018-292-017 Insulating Cap 5.0 black 018-292-027 Protection Cap 5.0 black 018-210-001 BNC Adapter 5.0 890-700-000 PCB Adapter 5.0 972405100 Safety Alligator Clip black 890-220-000 Flexible Adapter 5.0 to 4 mm safety Banana plug 890-210-000 Flexible Adapter 5.0 to 4 mm Banana Plug 890-320-000 Sprung Hook 5.0 black 890-202-000 Flexible Adapter 5.0 to 2 mm Banana Plug 890-510-700 Adapter 5.0 to 0.8 mm socket 890-500-13X QFP IC-Clip 13 mm long down to 0.5 mm pitch ( X : 4 = yellow; 5 = green ) P25SCHWARZ Pico hook 890-520-701 Dual Adapter 5.0 to 0.8 mm socket 890-500-00X QFP IC-Clip short down to 0.5 mm pitch ( X : 4 = yellow; 5 = green ) 10

Probe Accessories 018-292-006 Adjustment Tool T 018-292-024 Adjustment Tool BERNSTEIN 890-010-912 Set Coding Rings 3x4 colors 893-250-001 2 Footer Positioner 890-450-220 HF Compensated Ground Lead 22 cm 891-005-011 5x Solid Tip 0.8 mm 891-005-803 5x Solid Tip 0.8 mm 018-594-808 Spring Tip gold-plated Style H 018-594-804 Spring Tip gold-plated Style C 890-400-015 890-400-000 Ground Lead 15 cm Ground Lead 22cm 890-501-380 5x Spring Tip 0.38 mm 018-594-810 Spring Tip gold-plated Style G 018-594-809 Spring Tip gold-plated Style K 890-400-104 Ground Lead 22 cm to 4 mm Banana Plug 018-291-012 Solid Tip 30 mm gold-plated 018-594-806 Spring Tip gold-plated Style E 890-400-102 Ground Lead 22 cm to 2 mm Banana Plug 018-594-805 Spring Tip gold-plated Style D 890-100-150 10 self adhesive Cu Pads ( 2 x 2 cm ) 890-400-003 Ground Spring 5.0 018-291-102 Ground Blade 5.0 890-400-011 Ground Lead 11 cm to Miniclip DEVICE UNDER TEST 890-400-013 Ground Lead 11 cm to 0.8 mm plug 11

Scope of Delivery The following items are included in the scope of delivery. Please check the delivery for completeness. If any item is missing, send a message to our service department and we will send you this item immediately. Item Qty 2 Footer Positioner 1 Adjustment Tool T 1 BNC Adapter 1 Ground Blade 5.0 1 Ground Lead 22 cm 1 IC-Cap 5.0 0.8 mm pitch; grey 1 IC-Cap 5.0 1.0 mm pitch; brown 1 IC-Cap 5.0 1.27 mm pitch; black 1 Instruction Manual 1 Insulating Cap 5.0 1 Probe 1 Protection Cap 5.0 1 (1) self adhesive Cu Pad (2 x 2 cm) 2 Solid Tip 0.8 mm 1 Spring Tip 0.8 mm 1 (2) Sprung Hook 5.0 1 (1) plugged on probe (2) installed in probe Use ground lead only for connections to earth ground. The BNC Adapter is rated: 100 V rms CAT II, Pollution Degree 1 The accessories provided with the probe have been safety tested. Do not use any other accessories than those originally provided. M25-221-A00 Revision C - Juli 2011