Keysight E7515A UXM Firmware Update Tool

Similar documents
Keysight GUI Data Logger Software for U1731C, U1732C, and U1733C Handheld LCR Meter

Keysight N5191A/93A UXG X-Series Agile Signal Generator

Operations and Installation Manual. Keysight 85132E/F 3.5 mm to 7 mm Test Port Return Cables

Keysight N5990A Test Automation Software Platform

Keysight N5990A DisplayPort Extended Tests Embedded DisplayPort

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures.

Keysight N5990A Type-C Extension. User Guide

Agilent W2100 Antenna Modeling Design System

Agilent OpenLAB Chromatography Data System (CDS)

Keysight N7015A/16A Type-C Test Kit. User Guide

Agilent CytoGenomics 2.5

Keysight Combiner and Mechanical Switches Upgrade Kit

Firmware Guide. Keysight PXIe Chassis Family

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit

BenchCel Workstations Software

Agilent CSV Export Utility

Agilent OpenLAB Chromatography Data System (CDS)

Keysight M9393A PXIe Vector Signal Analyzer

Agilent OpenLAB Chromatography Data System (CDS)

Agilent OpenLAB Data Analysis Upload Download Tool. User s Guide

Keysight Software. Installation Guide

Keysight 11878A 50 Ohm 3.5 mm Adapter Kit

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

Agilent OpenLAB Data Store Administration. Guide for Administrators

Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit

86100 Series Infiniium DCA Oscilloscope

Agilent G2721AA/G2733AA

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Keysight N108xA-Series IEEE Ethernet KR/CR Compliance and Debug Application

Agilent OpenLAB. Data Store. Backup and Restore Guide

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz

Agilent OpenLAB Chromatography Data System

Agilent Lab Advisor. IT Administrator's Guide. Agilent Technologies

Agilent 1260 Infinity Purification Solution

Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Agilent Series Logic Analysis System

Agilent OpenLAB. Data Store. Maintenance Guide

Agilent ChemStation Plus

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Agilent OpenLAB Chromatography Data System

Keysight DSOXT3NFC/ DSOX4NFC Near Field Communication Test Application

Agilent E2094M IO Libraries

Agilent Technologies E5385A 100-Pin Probe

Agilent M9502A and M9505A AXIe Chassis Firmware Revision. Firmware Update Guide. Agilent Technologies

Microscan Barcode Reader

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

Errata. Agilent References in this manual. About this manual. Support for your product

Agilent ChemStation Plus

DDR/LPDDR Custom Configuration Creator Tool. User s Guide

Keysight U2722A/U2723A USB Modular Source Measure Units

Agilent Genomic Workbench 6.0

Agilent OBSAI Protocol Tester

Agilent ChemStation. ECM Interface Guide. Agilent Technologies

Agilent Genomic Workbench 7.0

Agilent 89600B VSA. Software Installation Guide

Keysight Add 4-Port Capability Upgrade Kit

Agilent OpenLAB Data Store. Maintenance Guide

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Agilent OpenLAB Chromatography Data System (CDS)

Agilent InfiniiMax II 1168A/1169A Probes

Agilent E4418/19A Power Meter Hardware Upgrade Kit

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

Setting Up Probes. Online Help

Agilent EZChrom SI. Startup Guide

Agilent Technologies. Connectivity Guide. USB/LAN/GPIB Interfaces. Agilent Technologies

Keysight Wireless Test Sets

Agilent OpenLAB Chromatography Data System (CDS)

Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect

87421/22A Power Supply. Operating and Service Manual

Agilent MSD Productivity ChemStation G1701 & G1710. Performance Report Parameters

User s Guide. Keysight W2635A and W2636A DDR3 BGA Probe Adapters for Oscilloscopes

Agilent OpenLAB ECM Intelligent Reporter

Keysight N5990A-155 Display Port. User Guide

Agilent Dissolution Tester Driver

Errata. Agilent References in this manual. About this manual. Support for your product

Keysight N5990A-104 Test Automation Software Platform for Thunderbolt. User Guide

Agilent Gb/s Serial BERT

Keysight N5990A-301 PCI Express Link Training Suite. User Guide

Agilent Genomic Workbench 7.0

BIT-3000 Dynamic Sequencing Generator and Analyzer. Datasheet 1.11

Copyright 1998, 2009, Oracle and/or its affiliates. All rights reserved.

Automated Plate Labeling

Quick Start/Installation Guide

Agilent Genomic Workbench Lite Edition 6.5

Keysight Software

Agilent OpenLAB CDS. ChemStation Edition Instrument Configuration. Guide. Agilent Technologies

Keysight MIPI M-PHY Command Line Packet Generator. User s Guide

Agilent Genomic Workbench 6.5

Keysight Add Source and Receiver Attenuators Upgrade Kit

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

JD Edwards EnterpriseOne 8.12 Standalone Client Installation Guide. for the Oracle Application Server

Agilent 7890 Series Gas Chromatograph

Agilent 1120 Compact LC Firmware

Agilent Protocol Analyzer and Jammer for USB. Quick Start Guide

New Features in Primavera Professional 15.2

Keysight Add 4-Port Capability Upgrade Kit

Oracle Enterprise Single Sign-on Logon Manager How-To: Configuring ESSO-LM Event Logging with Microsoft SQL Server 2005 Release

G5584A Labware MiniHub

Agilent OpenLAB CDS Waters Alliance HPLC Instrument Control Add-On. Installation, Upgrade and Migration Guide

Transcription:

Keysight E7515A UXM Firmware Update Tool For the E7515A UXM Wireless Test Set Installation & User Guide

Notices Keysight Technologies, Inc. 2014-2017 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Keysight Technologies, Inc. as governed by United States and international copyright laws. Trademark Acknowledgments Manual Part Number E7515-90022 Edition Edition 1, March 2017 Printed in USA/Malaysia Published by: Keysight Technologies 1400 Fountaingrove Parkway Santa Rosa, CA 95403 Warranty THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED AS IS, AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCUMENT OR ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL. Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. U.S. Government Rights The Software is commercial computer software, as defined by Federal Acquisition Regulation ( FAR ) 2.101. Pursuant to FAR 12.212 and 27.405-3 and Department of Defense FAR Supplement ( DFARS ) 227.7202, the U.S. government acquires commercial computer software under the same terms by which the software is customarily provided to the public. Accordingly, Keysight provides the Software to U.S. government customers under its standard commercial license, which is embodied in its End User License Agreement (EULA), a copy of which can be found at http://www.keysight.com/find/sweula The license set forth in the EULA represents the exclusive authority by which the U.S. government may use, modify, distribute, or disclose the Software. The EULA and the license set forth therein, does not require or permit, among other things, that Keysight: (1) Furnish technical information related to commercial computer software or commercial computer software documentation that is not customarily provided to the public; or (2) Relinquish to, or otherwise provide, the government rights in excess of these rights customarily provided to the public to use, modify, reproduce, release, perform, display, or disclose commercial computer software or commercial computer software documentation. No additional government requirements beyond those set forth in the EULA shall apply, except to the extent that those terms, rights, or licenses are explicitly required from all providers of commercial computer software pursuant to the FAR and the DFARS and are set forth specifically in writing elsewhere in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. With respect to any technical data as defined by FAR 2.101, pursuant to FAR 12.211 and 27.404.2 and DFARS 227.7102, the U.S. government acquires no greater than Limited Rights as defined in FAR 27.401 or DFAR 227.7103-5 (c), as applicable in any technical data. Safety Notices A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.

Where to Find the Latest Information Documentation is updated periodically. For the latest information about these products, including instrument software upgrades, application information, and product information, browse to one of the following URLs, according to the name of your product: http://www.keysight.com/find/uxm To receive the latest updates by email, subscribe to Keysight Email Updates at the following URL: http://www.keysight.com/find/mykeysight Information on preventing instrument damage can be found at: www.keysight.com/find/preventinginstrumentrepair Is your product software up-to-date? Periodically, Keysight releases software updates to fix known defects and incorporate product enhancements. To search for software updates for your product, go to the Keysight Technical Support website at: http://www.keysight.com/find/techsupport 3

4

Keysight Wireless Test Set E7515 UXM Firmware Update Tool Installation & User Guide Firmware Update Tool The E7515A UXM Firmware Update Tool is designed as a one-click application which allows you to easily update the firmware of E7515A UXM units. Just selecting a firmware version and clicking on a button, you can uninstall the current UXM firmware version and install the new one, including an update of the required software components. This application must be installed and executed in the UXM embedded PC, running Microsoft Windows 7 Standard Embedded Edition. The application can be executed only by local Administrator user, and no other users can be logged on the system. It also will work only on UXM units. The following sections are included here: Firmware Update Tool on page 5 Installation on page 6 Repository on page 7 on page 8 Add Versions on page 8 Remove Versions on page 10 Get UXM Information on page 11 Firmware Update on page 12 Special Considerations on page 15 Restrictions on page 17 5

Installation Installation Figure 1-1 The E7515A UXM Firmware Update Tool is distributed as a Windows installer: UXM_FirmwareUpdateTool_Installer_x.y.w.z.exe To install the application just execute the installer and follow the guided installation dialogs. Once installed, the application can be launched from Windows Start menu: All Programs > Keysight E7515A UXM > Firmware Update Tool Firmware Update Tool in the Windows Start Menu 6 Installation & User Guide

Repository Repository Figure 1-2 The UXM Firmware Update Tool repository is located at: D:\ProgramData\Keysight\E7515A\Firmware To be able to update the UXM firmware to a specific version, the installer associated with that version must be present in the repository folder. UXM firmware installers file names must be in the form E7515A_UXM_*.exe to be recognized by the application. Repository for the Firmware Update Tool Installation & User Guide 7

Add Versions There are three different options for adding UXM versions to the application repository. The first method is to select Add from the Versions menu: Figure 1-3 Adding a version (using Versions menu) The second method is to select Add from the menu invoked by right-clicking on the list of firmware versions: Figure 1-4 Adding a version (using right-click menu) 8 Installation & User Guide

The third method is to use Windows Explorer to copy an installer file into the repository folder. In that case, the list box has to be refreshed from within the application, using any of these methods: Selecting Refresh on the Versions menu. Selecting Refresh on the menu which is invoked by right-clicking on the list of firmware versions. Pressing the F5 key. Installation & User Guide 9

Remove Versions There are three different options for removing UXM versions from the application repository. The first method is to select Remove from the Versions menu: Figure 1-5 Removing a version (using Versions menu) The second method is to select Remove from the menu invoked by right-clicking on the list of firmware versions: Figure 1-6 Removing a version (using right-click menu) 10 Installation & User Guide

The third method is to use Windows Explorer to delete an installer file from the repository folder. In that case, the list box has to be refreshed from within the application, using any of these methods: Selecting Refresh on the Versions menu. Selecting Refresh on the menu which is invoked by right-clicking on the list of firmware versions. Pressing the F5 key. Get UXM Information The application can display information about the version of the UXM firmware currently installed in the unit, as well as for all the installed software components that are part of this firmware. This information can be displayed in a text box by pressing the F6 key, or by selecting Get from the Information menu: Figure 1-7 Getting information from the UXM Installation & User Guide 11

Firmware Update Before starting a firmware update it is highly recommended to close any running application that interacts with the UXM, and disconnect the LAN. The UXM firmware update process can be launched by double-clicking on a firmware version element in the list box of available versions, or by selecting a firmware version from the list and clicking the Update button. Figure 1-8 Launching a firmware update 12 Installation & User Guide

Before the update process begins, a confirmation dialog appears, showing the firmware version number the UXM unit will be updated to: Figure 1-9 Confirming the firmware update Clicking YES causes the update operation to start. Information about the process is displayed in the Update Process Information text box. A green progress bar is also displayed. The update process can take 30 minutes or more. Figure 1-10 Update Process Information Installation & User Guide 13

When the update operation is finished, a new dialog is displayed, indicating that the update is completed. Figure 1-11 Completion dialog After you dismiss the dialog (by clicking OK), you can check the installed firmware version by requesting the UXM information (click on Information > Get from UXM, or press the F6 key). Figure 1-12 Checking the installed firmware version 14 Installation & User Guide

Special Considerations Arrays If the UXM unit is part of an array ( Main or Auxiliary role), starting the update process causes the UXM to exit automatically from the array, and operate as a StandAlone unit. Reboot The UXM firmware update operation may require the unit to be rebooted during the process. If that happens, you will be informed in the update confirmation dialog, and also before the unit is rebooted. After the reboot, the process will continue automatically, with no user interaction required. Figure 1-13 Reboot warnings Installation & User Guide 15

al State The firmware update process concludes when the unit reaches the al state; if a SPC or XPC board is present, the process also waits until the board is in al state. If this state is not reached, an error message is displayed in the conclusion dialog. If the unit does not become operational, the following error is shown: Figure 1-14 Error message if UXM is not operational If the SPC/XPC board is present but doesn t become operational, the following errors are shown: Figure 1-15 Error message if SPC/XPC board is not operational 16 Installation & User Guide

Restrictions Restrictions The following version restrictions apply to the Firmware Update Tool. Versions Too Low or Too High UXM firmware versions lower than 1.4.0.0, and versions equal or greater than 1.10.0.0, are not supported. The following dialogs will be displayed: Figure 1-16 Error messages if the version is too low or high Versions Not Compatible with SPC or XPC If neither an SPC board nor an XPC board is installed, any version of the firmware which isn t too high or low (see above) can be installed. However, the SPC and XPC boards have compatibility requirements for specific versions of firmware: If the SPC board is installed in the unit, then UXM firmware versions 1.7.2.x, 1.8.2.x, and 1.9.2.x cannot be used to update the system. If the XPC board is installed in the unit, then only UXM firmware versions 1.7.2.x, 1.8.2.x, and 1.9.2.x can be used to update the system. Installation & User Guide 17

Restrictions The following dialogs will be displayed if you try to update to a firmware version not compatible with the installed hardware: Figure 1-17 Errors shown if the version selected isn t compatible with installed hardware If you install an SPC/XPC board, and the currently installed firmware is not compatible with the new hardware, you will be blocked from running the firmware update to correct the problem (see the error messages illustrated below). Therefore, it is necessary to run the firmware update before installing the SPC/XPC board. If you have installed the board already, your two options are: Unplug the SPC/XPC board, update the firmware to a version compatible with it, and then plug it in again. Uninstall the UXM firmware manually from Windows Control Panel (under Control Panel > Programs > Programs and Features, select Keysight E7515A UXM and right-click Uninstall). Then install a version compatible with the new board. Figure 1-18 Errors shown if added hardware isn t compatible with installed version 18 Installation & User Guide

This information is subject to change without notice. Keysight Technologies 2017 Edition 1, March 2017 E7515-90022 www.keysight.com