VARAN Manager PCI Insert module PCV 521 Versatile Automation Random Access Network

Similar documents
DIAS Interface Module VARAN DIV 511

VARAN Splitter Module VSV 041

VARAN Splitter PROFINET VSP 044

Protected VARAN Digital Mixed Module PVDM 086

VARAN Bus Coupler Module VBC 021 For connecting two VARAN bus systems

VARAN Digital Combined Module VDM 086

VARAN Splitter Module VSV 043

C-DIAS VARAN Control Module CIV x VARAN-In 1 x VARAN-Out (Optional Ethernet (VtE))

VARAN Client Board VEB 011/012 Versatile Automation Random Access Network

VARAN Splitter PROFINET VSP 042

VARAN-INTERFACE VAC 012

C-IPC Expansion VM 052 (C-IPC VARAN Manager 052) Versatile Automation Random Access Network

VI 021 S-DIAS VARAN Control Module

C-DIAS EtherNet/IP Slave CIP 022

C-DIAS-Temperature Recording module CAI x Temp. inputs 50 C to +150 C

TSY 041 Training System Extension Motion

C-DIAS Digital Input Module CDI 161 with 16 inputs

Expansion Module HZS 541-1S

Internal Buffer/Boiler Module HZS 534

C-DIAS Profibus DP Slave module CPB 021

C-DIAS Analogue Output Module CAO 081 for eight 10V DC outputs

to 12a Added Standard and Electrical requirements for UL table 1.1

TO 161 S-DIAS Digital Output Module

Technical Data. C-DIAS-MULTI l/o MODULE CIO 013

C-DIAS Serial Interface CSI 021

SE 051 S-DIAS Splitter Ethernet

DI572 Digital Input Module

HZS Internal Controller Expansion

DI561 Digital Input Module

ISE 021 S-DIAS Interface Module RS232 / RS485

ETT 312 Build-In Touch Terminal

DM 161 S-DIAS Digital Mixed Module

AO 081 S-DIAS Analog Output Module

Profibus DP slave. dual ported RAM 2Kbyte. Maximum length for I/O data. Maximum length for output data. Status display

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

DX561 Digital Input/Output Module

C-DIAS Temperature sensing module CAI x temp. inputs C 8 x digital outputs +24V

Keyboard Unit Sigmatek

AO561 Analog Output Module

DC562, digital input/output module,

C-DIAS Analogue Conversion Module CAM 124 for eight 0 10V DC inputs and four 10V outputs

TF501, TF521 Terminal Bases

5-Port Industrial Ethernet Switch - DIN Rail Mountable

ICA 012 S-DIAS Interface Module CAN

TN-5308 Quick Installation Guide

RO 051 S-DIAS Relay Output Module

AI561 Analog Input Module

C-DIAS Analog Module CAO 086 For eight ±10 V Outputs

DC561, digital input/output module,

net4more IP connected lighting system net4more Driver net4more driver DC 30W mA un:c LED Driver for net4more systems

Ha-VIS mcon 3000 Next Generation Introduction and features

Technology modules. 1 SSI interface for absolute encoders, 1 analog output S20-SSI-AO-1/1

PC 521 Data Recording PC

Fork sensors and optical windows

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

TU531, TU532 Terminal Unit

TM3DI16G module TM3-16 inputs spring

RS485 MODBUS Module 6RO

TM241CE24T controller M IO transistor PNP Ethernet

AO523 Analog Input Module

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

RMCN22BD Analog Converter ma - for Zelio Analog

IST ULTRASTAB Power Supply for high precision transducers

Connection Cables for Operating Devices

SI 021 S-DIAS SSI Interface Module

CM597 Ethernet Communication Module

Legacy Serial. Legacy Serial Redundant Ring Ethernet Extender DDW-222. High Speed Ethernet extension over copper. Configuration and diagnostics

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

TM221CE40T controller M IO transistor PNP Ethernet

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

PTC-101-M12 Hardware Installation Guide

CM589 PROFINET Communication Module

Micropulse Transducers

KL 181 S-DIAS +24 V Potential Distributor Module

CM579-PNIO PROFINET Communication Module

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

TM221CE24R controller M IO relay Ethernet

Fork sensors and optical windows

TM241CE24U controller M IO transistor NPN Ethernet

Time Counters mini "h", DC Version

GIN-SAM4. Hardware User Manual. Version: 1.02 Date: Language: English

TM241CE40R controller M IO relay Ethernet

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

TM3DI16 module TM3-16 inputs

Ethernet Media. Introduction Quick Selection Ethernet Media. Systems. PannelConnect Connection. Connection. Safety.

optical sensors through-beam, retro-reflective, dif. reflection sensors 3000 transmitter with test input robust metal housing

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

HZS Solar Module

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

User Manual. MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T

PTC-101 Quick Installation Guide

TM3AI4 module TM3-4 analog inputs

INJ-24A Series Quick Installation Guide

Hardened 4-Port 10/100/1000M DIN-Rail Mount Switch GATB. User's Manual (V1.0 Version)

TM200CE24T controller M IO transistor Source+ Ethernet

AI531 Analog Input Module

camera sensor ipf opti-check 1070 fully integrated camera system contour-based recognition

Added Standard and Electrical requirements for UL table Switching-off inductive loads 1.2

GFK-2415A March Type of sensor connection

Industrial Ethernet Switch

Transcription:

PCI INSERT MODULE PCV 521 VARAN Manager PCI Insert module PCV 521 Versatile Automation Random Access Network The PCI insert module, PCV 521, can be used in any standard PC. A VARAN Manager is available on the PC and serves as an interface between the PC and VARAN bus. With the PVC 521, VARAN modules can be controlled by the PC directly. Technical Data Performance data PCI-Bus 32-Bit PCI bus card / 33 MHz Vendor ID: 5112 Device ID: 0C00 VARAN bus 2 x VARAN-Out (Manager) (maximum length: 100 m) Status display Green: Link Yellow: Active 15.02.2011 Page 1

PCV 521 PCI-EINSTECKMODUL Electrical requirements Supply voltage +5V DC (from PCI bus) Current consumption on the PCI bus (+5V) Supply voltage Typically 1mA +3,3V DC ( from PCI bus) Maximum 5mA Current consumption on the PCI bus (+3,3V) Typically 400mA Maximum 450mA Miscellaneous Article number 01-320-521 Hardware version 1.x Environmental conditions Storage temperature Operating temperature Humidity -20 +85 C 0 +60 C 0 95%, Uncondensed EMV stability According to EN 61000-6-1 Shock resistance EN 60068-2-27 150m/s² Page 2 15.02.2011

PCI INSERT MODULE PCV 521 Mechanical Dimensions 15.02.2011 Page 3

PCV 521 PCI-EINSTECKMODUL Connector Layout Page 4 15.02.2011

PCI INSERT MODULE PCV 521 X1, X2: VARAN-Out Pin Function 1 TX/RX+ 2 TX/RX- 3 RX/TX+ 4 5-6 RX/TX- 7 8 - LEDs Yellow Green Function ACTIVE LINK LED Color Description ACTIVE Yellow Lights when data is received over the VARAN bus. LINK Green Lights when the connection between the two PHYs is established. More information over the VARAN bus can be found in the VARAN bus specifications! Applicable connector VARAN-Bus: 8-pin RJ45 CAUTION: Insert cards with a +5V level used on the PCI bus with the PCV 521; this will destroy the PCV 521. 15.02.2011 Page 5

PCV 521 PCI-EINSTECKMODUL VARAN Recommended Shielding The VARAN real-time Ethernet bus system offers robust performance in harsh industrial environments. Through the use of IEEE 802.3 standard Ethernet physics, the potential between an Ethernet line and sending/receiving components is kept separate. The VARAN Manager resends messages to a bus participant immediately when an error occurs. It is principally recommended that the shielding guidelines below be followed. For applications in which the bus line is run outside the control cabinet, correct shielding is required. This is especially important, if due to physical requirements, the bus lines must be placed next to sources of strong electromagnetic noise. It is recommended that whenever possible, to avoid wiring VARAN-Bus lines parallel to power cables. SIGMATEK recommends the use of CAT5e industrial Ethernet bus lines. For the shielding variants, an S-FTP bus line is recommended, which is a symmetric, multiwire cable with unshielded pairs. For the total shielding, a combination of foil and braiding is used; it is recommended that an unvarnished variant be used. The VARAN cable must be secured at a distance of 20 cm from the connector for protection against vibration! Page 6 15.02.2011

PCI INSERT MODULE PCV 521 1. Wiring from the Control Cabinet to an External VARAN Component If the Ethernet lines are connected from a VARAN component to a VARAN node outside the control cabinet, the shielding should be placed at the entry point to the control cabinet housing. All noise can then be deflected from the electronic components before reaching the module. 15.02.2011 Page 7

PCV 521 PCI-EINSTECKMODUL 2. Wiring Outside of the Control Cabinet If a VARAN bus cable must be placed outside of the control cabinet only, no additional shield connection is required. This requires that only IP67 modules and connectors be used. These components are very robust and noise resistant. The shielding for all sockets in IP67 modules are internally connected to common bus or electrically connected to the housing, whereby the deflection of voltage spikes does not flow through the electronics. Page 8 15.02.2011

3. Shielding for Wiring Within the Control Cabinet PCI INSERT MODULE PCV 521 Sources of strong electromagnetic noise located within the control cabinet (drives, Transformers, etc.) can induce interference in a VARAN bus line. Spike voltages are deflected over the metallic housing of a RJ45 connector. Noise is conducted through the control cabinet housing without further action from the electronic components To eliminate sources of noise during data transfer, it is recommended that the shielding from all electronic components be connected within the control cabinet. 15.02.2011 Page 9

PCV 521 PCI-EINSTECKMODUL 4. Connecting Noise-Generating Components With the connection of power components that generate strong electromagnetic noise, it is also critical to ensure correct shielding. The shielding should be placed before a power component (or a group thereof). Page 10 15.02.2011

5. Shielding Between Two Control Cabinets PCI INSERT MODULE PCV 521 If two control cabinets must be connected over a VARAN bus, it is recommended that the shielding be located at the entry points to both cabinets. Noise can thereby be kept from reaching the electronics within the control cabinet. 15.02.2011 Page 11

PCV 521 PCI-EINSTECKMODUL Page 12 15.02.2011