is then retained absolutely without interruption.

Similar documents
Considerations for Use. of the SITOP DC UPS Module

SITOP in the SIMATIC Design

SIPLUS S7-200 PS 203. Overview

SITOP 3-phase 24 V DC, 20 to 40 A

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

PHOENIX CONTACT - 01/2007

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

PHOENIX CONTACT - 07/2006

Uninterruptible Power Supply Unit for Universal Use QUINT-DC-UPS/24DC/40

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Industrial Power Supplies

SITOP PSU8600 power supply system

QUINT-BUFFER/24DC/24DC/40

Industrial Power Supplies

MINI-PS AC/10-15DC/8

Uninterruptible power supply - TRIO-UPS/1AC/24DC/

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

onlinecomponents.com

Product and functional description

DPM Digital DC Power Meter with Data logging capability. User Manual

PHOENIX CONTACT Features

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

TRIO-DIODE/12-24DC/2X10/1X20

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Chrome DC-UPS Module 24V 10A / DRU-24V10ACZ

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

MINI MCR-SL-UI-REL(-SP)

Electronic timer CT-ERS.21

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Power Supply HARTING pcon

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

DIN Rail. user manual Models , & INT /503556/ UM

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

STEP-PS/1AC/24DC/1.75

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Contact protection relay

General information Engineering with Programming package. Display with display

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

QUINT-PS-3x AC/24DC/10

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Power Supply HARTING pcon

Redundancy unit CP-A RU

SITOP PSU300M/300B. SITOP power supply SITOP PSU300M/300B. Overview. Safety notes 1. Description, device design, dimension drawing 2

General information. Display. Supply voltage. Input current

RTU500 series Data Sheet Power Supply CP-E 24/2.5

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Andover Continuum. Power Supplies with or without UPS

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

What supplies 24 V DC even with voltage fluctuations, power failures, or overload reliably?

Installation / Control Technique

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

General information. Display. Supply voltage

TM221CE40T controller M IO transistor PNP Ethernet

Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual Pulsar Series

Electronic timer CT-AHD.22

Electronic timer CT-ERD.12

Power supply module, bus connection module

Electronic time relays ATI, BTI, SDT and MTI

TM221M16TG controller M IO transistor PNP spring

TM221M16R controller M IO relay

SITOP power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/removal 3

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

TM221M32TK controller M IO transistor PNP

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Operating instructions. Standstill monitor A / / 2011

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

TM221ME32TK controller M IO transistor PNP Ethernet

Disconnect Switches. Safe Switching and Disconnecting

Siemens AG 2015 SITOP. Power Supply SITOP. Catalog KT Edition siemens.com/sitop

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage

CU port USB 2.0 hub. Version: 1.1 Date:

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

MINI MCR-SL-UI-2I(-SP)(-NC)

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

Signal Doublers. VariTrans A 20300

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

QUINT-PS AC/24DC/10

TM221ME16T controller M IO transistor PNP Ethernet

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

Transcription:

Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 6 A Compact design, only 50 mm wide Simple DIN rail mounting Absolutely interruption-free buffering of mains failures through immediately electronic connection of the batteries as soon as the DC UPS input voltage drops below the value set using DIP switches High safety and availability through monitoring of operational readiness, battery supply line, battery aging (message "Battery replacement necessary") and battery charge (message "Battery charge >85%") Support of automatic restart of industrial PCs through selectable switch-off response Optionally with serial or USB interface. SW tool as download at http://www.siemens.de/sitop executes under WinNT4.0, Win2000 and WinXP. The following timing diagrams show examples of the characteristic of the input and output voltages at the terminals of the DC-UPS module as well as the signal chart of the signals (relays) and of the remote signal (port). "Long" voltage failure with DC UPS without serial or USB port (Fig. 1) Voltage return only once buffer time tp (t3 follows t4) has expired: Upon failure of the input voltage on the DC-UPS module (time t1), the battery "Bat" immediately takes over the DC supply, and the output voltage U out is then retained absolutely without interruption. The isolated changeover contact "OK/Bat" switches over to its off position "Bat". At the same point in time t1, the buffer time tp set on the DIP switches is started automatically. The fact that the DIP switch is set to "Interruption output U out " in this example has no effect because the input voltage returns at time t3 only once the set buffer time (time t4) has expired. "Short" voltage failure with DC UPS without serial or USB port (Fig. 2) Voltage return before buffer time tp (t3 before t4) has expired:

Page 2 of 11 Upon failure of the input voltage on the DC-UPS module (time t1), the battery "Bat" immediately takes over the DC supply, and the output voltage U out is then retained absolutely without interruption. The isolated changeover contact "OK/Bat" switches over to its off position "Bat". At the same point in time t1, the buffer time tp set on the DIP switches is started automatically. With the DIP switch set to "Interruption output U out ", the output voltage U out is automatically interrupted for 5 s once the set buffer time tp (time t4) has expired. The accumulator has already been disconnected because the input voltage has returned at the time t3. If the DIP switch is not set to "Interruption output U out " there is no interruption in this example because the input voltage has already returned at time t3 prior to expiry of the set buffer time (time t4). Buffer time (time t4) automatically interrupted for 5 s and the accumulator, which has not yet been disconnected because of the missing input voltage, is simultaneously disconnected from the output. Fig. 1 "Long voltage failure" Fig. 2 "Short voltage failure" DC UPS without serial or USB port (6EP1931-2DC21/2EC21) DIP switch positions on device: buffer time tp (from 5 s to 635 s with bottom row nos. 2 to 7)//t = according to setting (with bottom row no. 1 to left)/xxxx = with setting for interruption U out (with bottom row no. 8 to left) Legend: U in : input voltage at terminals X1.1 X1.2 U out : output voltage at terminals X1.3 X1.4 and X1.5 - X1.6 OK: signal for input voltage U in OK or above the set accumulator connection threshold

Page 3 of 11 Bat: signal for battery operation (accumulators connected to output, accumulators power the load) Remote: signal for remote timer start with signal level = 0 at pin 7 of 9-pin serial port (pin 7 is usually the positive power supply for the port) t1: input voltage U in failed or fallen below set connection threshold t2: buffer time set on DIP switches is started by remote timer start (signal level = 0) t3: input voltage U in rises above set connection threshold t4: end of set buffer time (output is switched off and/or accumulator is disconnected) t5: output is connected again 5 s after shutdown tp: buffer time set on the DIP switches (bottom row nos. 2 to 7) "Long" voltage failure with DC UPS with serial or USB port (Fig. 3) Voltage return only once buffer time tp (t3 follows t4) has expired: Upon failure of the input voltage on the DC-UPS module (time t1), the battery "Bat" immediately takes over the DC supply, and the output voltage U out is then retained absolutely without interruption. The isolated changeover contact "OK/Bat" switches over to its off position "Bat". The buffer time tp set on the DIP switches is started at the user-selectable time t2 by means of the signal "Remote timer start" (signal level = 0 at pin 7 of the 9-pin serial port following previous signal chart according to operating instructions). The fact that the DIP switch is set to "Interruption output U out " in this example has no effect because the input voltage returns at time t3 only once the set buffer time (time t4) has expired. Note: Without a remote signal level = 0 with a setting t = max. duration, there is no interruption to the output voltage in this case because the set buffer time is not started (or interruption only if the exhaustive discharge protection disconnects the accumulator and the input voltage has not returned by then). "Short" voltage failure with DC UPS with serial or USB port (Fig. 4) Voltage return before buffer time tp (t3 before t4) has expired: Upon failure of the input voltage on the DC-UPS module (time t1), the battery "Bat" immediately takes over the DC supply, and the output voltage U out is then retained absolutely without interruption. The isolated changeover contact "OK/Bat" switches over to its off position "Bat". The buffer time tp set on the DIP switches is started at the user-selectable time t2 by means of the signal "Remote timer start" (signal level = 0 at pin 7 of the 9-pin serial port following previous signal chart according to operating instructions). With the DIP switch set to "Interruption output U out ", the output voltage U out is automatically interrupted for 5 s once the set buffer time tp (time t4) has expired. The accumulator has already been disconnected because the input voltage has returned at the time t3. The interruption to the output voltage U out for 5 s permits an automatic restart for many industrial PCs, even if the line voltage (or the input voltage U in on the DC-UPS module) returns during shutdown of the PC, as in this example. Note: Without a remote signal level = 0 with a setting t = max. duration, there is no interruption in the output voltage here because the set buffer time is not started.

Page 4 of 11 Fig. 3 "Long voltage failure" Fig. 4 "Short voltage failure" DC UPS with serial or USB port (6EP1931-2DC31/-2DC42/-2EC31/-2EC42) DIP switch positions on device: buffer time tp (from 5 s to 635 s with bottom row nos. 2 to 7)/t = max. time (with bottom row no. 1 to left)/interruption of U out (with bottom row no. 8 to left) Legend: U in :input voltage at terminals X1.1 X1.2 U out :output voltage at terminals X1.3 X1.4 and X1.5 - X1.6 OK: signal for input voltage U in OK or above the set accumulator connection threshold Bat: signal for battery operation (accumulators connected to output, accumulators power the load) Remote: signal for remote timer start with signal level = 0 at pin 7 of 9-pin serial port (pin 7 is usually the positive power supply for the port) t1: input voltage U in failed or fallen below set connection threshold t2: buffer time set on DIP switches is started by remote timer start (signal level = 0) t3: input voltage U in rises above set connection threshold t4: end of set buffer time (output is switched off and/or accumulator is disconnected) t5: output is connected again 5 s after shutdown tp: buffer time set on the DIP switches (bottom row nos. 2 to 7)

Page 5 of 11

Page 6 of 11 DC-UPS module 6 Order number 6EP1 931-2DC21 6EP1 931-2DC31 (with serial port) 6EP1 931-2DC42 (with USB port) Input L+/M in normal operation Rated voltage U in rated 1) Voltage range Connection threshold for accumulator Rated current I in rated Controlled DC voltage 24 V DC 22 V to 29 V DC 22.5 V DC ±0.1 V (factory setting), adjustable in the range 22 V to 25.5 V DC (in 0.5-V steps) 6 A + approx. 0.6 A with empty accumulator Line buffering Line buffering or buffer time On/off control circuit Buffering time Dependent on connected accumulator and load current: With battery module 3.2 Ah (6EP1935-6MD11) at +25 C: approx. 10 min. at 6 A; 20 min. at 4 A; 45 min. at 2 A With battery module 7 Ah (6EP1935-6ME21) at +25 C: approx. 30 min. at 6 A; 45 min. at 4 A; 150 min. at 2 A External isolated NO contact required (loading max. 15 V DC/max. 10 ma). With an open control circuit, the accumulator is isolated from output L+, thus canceling line buffering. Adjustable using DIP switches to a maximum buffering time up to forced shutdown through exhaustive discharge protection (at approx. 19 V) or to a time limit of 5 to 635 s (in 10-s steps) Output L+/M in normal operation Rated voltage U out rated Voltage range Output current I out Dynamic current with overload Dynamic current with shortcircuit 24 V DC (output voltage of SITOP power supply) Input voltage U in less approx. 0.5 V DC 0 A to 6 A Electronic current limitation to 1.05 to 1.4 x I out rated for approx. 80 ms, then electronic shutdown of the output with automatic restart attempts (approx. 20-s intervals between restart attempts) Electronic current limitation to 1.5 to 3 x I out rated for

Page 7 of 11 approx. 20 ms, then electronic shutdown of the output with automatic restart attempts (approx. 20-s intervals between restart attempts) Output L+/M with battery operation Rated voltage U out rated Approximate voltage range Output current I out Dynamic current with overload Dynamic current with shortcircuit Output +Bat/-Bat in normal operation End-of-charge voltage U Load current I 24 V DC (from battery module) 27 V to 19 V DC at I out = 0.05 x C x 1/h or 24 V at I out = 1 x C x 1/h or 23 V at I out = 2 x C x 1/h (C = total connected accumulator capacity in Ah), 19 V disconnection threshold for exhaustive discharge protection 0 A to 6 A (constantly permissible) Electronic current limitation to 1.05 to 1.4 x I out rated for approx. 80 ms, then electronic shutdown of the output with automatic restart attempts (approx. 20-s intervals between restart attempts) Electronic current limitation to 1.5 to 3 x I out rated for approx. 20 ms, then electronic shutdown of the output with automatic restart attempts (approx. 20-s intervals between restart attempts) CVCC charging characteristic (first constant current I, then constant voltage U) 27.0 V DC ±0.1 V (factory setting), adjustable in the range 26.3 to 29.3 V (in 0.1-V steps) Approx. 0.4 A (factory setting), adjustable to 0.2 A or 0.4 A (charging is carried out with closed and open on/off circuit) Efficiency/heat loss At U out rated, I out rated approx. With battery operation approx. 95%/7 W 94.5%/8 W Protection and monitoring Reverse-polarity protection Overload protection Short-circuit protection Against polarity reversal on input voltage and accumulators Electronic current limitation to 1.05 to 1.4 x I out rated for approx. 80 ms, then electronic shutdown of the output with automatic restart attempts (approx. 20-s intervals between restart attempts) Electronic current limitation to 1.5 to 3 x I out rated for

Page 8 of 11 approx. 20 ms, then electronic shutdown of the output with automatic restart attempts (approx. 20-s intervals between restart attempts). Built-in, inaccessible 16 A fuse Exhaustive discharge protection Monitoring "Wire breakage in accumulator circuit" Monitoring "Accumulator replacement required" Monitoring "Accumulator charge status > 85%" Automatic shutdown if accumulator voltage below approx. 19 V Alarm signal if accumulator circuit not closed or if it opens during operation (cyclic check approximately every 20 s) Alarm signal flashing at approx. 0.25 Hz (approx. 2 s alarm, approx. 2 s no alarm, approx. 2 s alarm, etc.). Check every 4 hours if there has been no buffering or shutdown within 4 hours Signal to indicate that accumulators are charged to at least 85% of rated capacity Signaling 2) Normal operation Buffering or battery operation (accumulator supplies load alone or in addition to PS in the case of overload) Alarm (buffer not ready, or prewarning at and above < 20.4 V accumulator voltage) "Accumulator replacement required" "Accumulator charge status > 85%" Green LED (OK) and isolated changeover contact "24 V DC OK/Bat" at setting "24 V DC OK" 3) Yellow LED (Bat) and isolated changeover contact "24 V DC OK/Bat" at setting "Bat" (= off position) Red LED (alarm) and isolated changeover contact at setting "Alarm" (= off position). Causes of the buffer not being ready during normal operation can include: Off status or open on/off control circuit, battery module not connected, polarity reversal or defective accumulator (accumulator voltage < 18.5 V) or wire breakage between accumulator and uninterruptible-power-supply module. Signal is scanned and, thus, updated, every 20 s. Causes of the buffer not being available during buffer operation can include: Accumulator voltage has dropped below 20.4 V DC (= prewarning before shutdown through exhaustive discharge protection) and shutdown of the accumulator due to overload, short-circuit, exhaustive discharge protection or expired buffer time. The red LED then goes out. Red LED (alarm) flashing at 0.25 Hz and isolated changeover contact (alarm) switching at approx. 0.25 Hz Second green LED (Bat > 85%) and isolated NO contact closed (off position = open) Optional port and software Serial port Only on 6EP1 931-2DC31

Page 9 of 11 Output of all signals and receipt of the "Remote Timerstart signal. Technical design: PC-compatible. 8N1 send and receive, 9600 baud, 8 data bits, 1 stop bit, no parity bit. Required connection to PC: 1 : 1 interconnected 9- pole sub D extension cable (connector/socket), only pin 2 (RXD), pin 3 (TDX) and pin 7 (RTS) are required. USB port Only on 6EP1 931-2DC42 Output of all signals and receipt of the "Remote Timerstart signal. Technical design: Specification 2.0 with full speed, i.e., 2 Mbit/s. Supplied with +5 V by DC UPS ("selfpowered"). Required connection to PC: Commercially available 4-core shielded cable, 90 Ohm, max. 5 m, USB series "A" connector to PC and USB series "B" connector to DC UPS Software A software tool (runs under WinNT 4.0, Win 2000 and WinXP) for reading out and processing the signals is available to download from the Internet at http://www.siemens.de/sitop This site also provides more information on the port. Control signals On/off control signal "Remote Timerstart" via serial port or USB Buffering is terminated or the accumulator is disconnected from the output by opening the control circuit (or by using DIP switches on the device). All other functions are retained. Starts line buffering for the set buffer time Security Primary/secondary galvanic isolation Protection class No Class III (ext. circuit and power supply unit: safety extra-low voltage required in accordance with EN 60950) EMC Emitted interference Radio interference suppression in accordance with EN 55022, limit-value curve B Noise immunity Noise immunity in accordance with EN 61000-6-2 Ambient conditions Ambient temperature during operation Transport/storage temperature 0 C to +60 C with natural convection -40 C to +70 C

Page 10 of 11 Degree of protection (EN 60529) IP20 Humidity class Conditions of use in accordance with EN 60721, climate class 3K3 (relative humidity 5% to 85% and Approvals absolute humidity 1 g/m 3 to 25 g/m 3 ; no condensation) CE UL/cUL CE conformity in accordance with 89/336 EEC UL 508/CSA C22.2, file E197259 Mechanical system Input connections 24 V DC 2 screw-type terminals for 1 mm to 4 mm 2 /17 to 11 AWG Output connections 24 V DC Accumulator-module connections 24 V DC Connections for control circuit and signals Dimensions (W x H x D) in mm Required clearances 4 screw-type terminals for 1 mm to 4 mm 2 /17 to 11 AWG 2 screw-type terminals for 1 mm to 4 mm 2 /17 to 11 AWG 10 screw-type terminals for 0.5 mm to 2.5 mm 2 /20 to 13 AWG 50 x 125 x approx.125 50 mm above and 50 mm below the device Weight Approx. 0.4 kg (with serial or USB port: approx. 0.45 kg) Mounting Snaps onto DIN rails DIN EN 50022-35x15/7.5 1) All SITOP 24 V DC power supplies are permissible without restriction. 2) Permissible contact rating: 60 V DC/1 A or 30 V AC/1 A 3) "24 V DC OK" means: voltage of the power-supply unit is greater than the accumulator connection threshold set on the DC-UPS module 6.

Page 11 of 11