Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Similar documents
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Overview of types. Technical data

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing

Functional data Factory settings Variable Setting Torque Inhibiting torque

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

s Spring return C / max C

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Technical data sheet. Technical data

Technical data. PRCA-BAC-S2-T en-gb subject to changes 1

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Brief description. Type overview

Brief description. Type overview

Products no longer available

Technical data sheets

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Products no longer available

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

VAV system solution for non-pressure dependent applications in enclosed spaces

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

NKQB24-1, NKQX24-1 On/Off, Electronic Fail-Safe, Direct Coupled, 24V

Technical data. Safety notes. Product features

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

Belimo Gateway MP to Modbus RTU - UK24MOD

Brief description. Service tool ZTH, PC-Tool service socket: locally pluggable or via PP connection.

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

A CLOSER LOOK. Electronic Fail-Safe Series Direct Coupled Actuators. The Belimo Difference. Brushless DC Motor for Added Accuracy and Controllability

ZN230-24MP-1 MP-BUS

Electrical Actuators

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Electrical Actuators

Electrical Actuators

Control engineering information VARYCONTROL VAV Units VAV Compact flow rate controller BC0 BF0

BUS. Adaptive control system for pressure applications (STP) Table of contents

Power consumption motor (motion) 2,5 W Power consumption standby (end position) 1,0 W. Position feedback -

Belimo Gateway MP to Modbus RTU - UK24MOD

Technical data sheet

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)

VA-7700 Series. Electric Valve Actuators. Product Bulletin

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Electromotoric actuators

ASI Systems ML5720A Series

EY-EM : Remote I/O module, ecolink

ML7421A,B Electric Linear Valve Actuators

BUS. Adaptive VAV control system for sensitive working areas. Table of contents

ASI Systems ML5740A Series

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

InReg Volume flow controller Pa

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Immersion Temperature Sensors

AVM 321, 322: Valve actuator

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

InCos-P Pressure sensor 20 Pa Pa

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and functional description

Operating instructions. Standstill monitor A / / 2011

Millenium II +: general characteristics

Product and functional description

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

24V, Motorized Actuators

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Rotary version, three-position control

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Modulating controlled actuator AME 11

Operating instructions. Switching amplifier DN0210 DN / / 2015

Actuators for modulating control AME 55, AME 56

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Electromotive actuators for combi valves

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

Operating Instructions VEGAMET 381

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

Transcription:

echnical data sheet LH24A-00-P Communicative linear actuator adjusting dampers and slide valves in technical building installations Air damper size up to approx. m² Actuating force 50 N Nominal voltage AC/DC 24 V Control communicative, modulating DC (0)2...0 V Variable Position feedback DC 2...0 V Variable Length of Stroke Max. 00 mm, adjustable in 20 mm increments Conversion of sensor signals Communication via Belimo -Bus echnical data Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency 50/60 Hz Nominal voltage range AC 9.2...28.8 V / DC 2.6...28.8 V Power consumption in operation 2.5 W Power consumption in rest position.2 W Power consumption for wire sizing 5 VA Connection supply / control erminals 4 mm² (cable Ø 4...0 mm, 4-wire) Parallel operation es (note the performance data) Functional data Actuating force motor Min. 50 N Modifiable actuating force 25%, 50%, 75% reduziert Positioning signal DC 0...0 V Positioning signal note Input impedance 00 kω Control signal variable Open-close 3-point (AC only) Modulating (DC 0...32 V) Operating range DC 2...0 V Operating range variable Start point DC 0.5...30 V End point DC 2.5...32 V Position feedback DC 2...0 V Position feedback note Max. 0.5 ma Position feedback variable Start point DC 0.5...8 V End point DC 2.5...0 V Position accuracy ±5% Direction of motion motor Selectable with switch Direction of motion note = 0 V: with switch 0 (retracted) / (extended) Direction of motion variable Electronically reversible Manual override With push-button, can be locked Length of Stroke Max. 00 mm, adjustable in 20 mm increments Stroke limitation can be limited on both sides with mechanical end stops Running time motor 50 s / 00 mm Motor running time variable 70...270 s / 00 mm Adaption setting range manual Adaption setting range variable No action Adaption when switched on Adaption after pushing the gear disengagement button Override control MAX (maximum position) = 00% MIN (minimum position) = 0% ZS (intermediate position, AC only) = 50% Override control variable MAX = (MIN + 32%)...00% MIN = 0%...(MAX 32%) ZS = MIN...MAX Sound power level motor 45 db(a) Safety Protection class IEC/EN III Safety extra-low voltage Protection class L L Class 2 Supply Degree of protection IEC/EN IP54 Degree of protection NEMA/L NEMA 2, L Enclosure ype 2 EMC CE according to 204/30/E www.belimo.eu LH24A-00-P en-gb 206-03-09 subject to changes

LH24A-00-P echnical data Safety Certification IEC/EN IEC/EN 60730- and IEC/EN 60730-2-4 Certification L clus according to L 60730-A, L 60730-2- 4 and CAN/CSA E60730-:02 Mode of operation ype Rated impulse voltage supply / control 0.8 kv Control pollution degree 3 Ambient temperature -30...50 C Non-operating temperature -40...80 C Ambient humidity 95% r.h., non-condensing Maintenance Maintenance-free Weight Weight 0.47 kg Safety notes! he device must not be used outside the specified field of application, especially not in aircraft or in any other airborne means of transport. Outdoor application: only possible in case that no (sea)water, snow, ice, insolation or aggressive gases interfere directly with the actuator and that is ensured that the ambient conditions remain at any time within the thresholds according to the data sheet. Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied during installation. he device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. he rotary supports and coupling pieces available as accessories must always be used if transverse forces are likely. In addition, the actuator must not be tightly bolted to the application. It must remain movable via the rotary support (refer to «Assembly notes»). If the actuator is exposed to severely contaminated ambient air, appropriate precautions must be taken on the system side. Excessive deposits of dust, soot etc. can prevent the gear rod from being extended and retracted correctly. If not installed horizontally, the gear disengagement pushbutton may only be actuated when there is no pressure on the gear rod. o calculate the actuating force required for air dampers and slide valves, the specifications supplied by the damper manufacturers concerning the cross section, the design, the installation site and the ventilation conditions must be observed. If a rotary support and/or coupling piece is used, actuation force losses are to be expected. he device contains electrical and electronic components and must not be disposed of as household refuse. All locally valid regulations and requirements must be observed. Product features Mode of operation Converter for sensors Parameterisable actuators Simple direct mounting Conventional operation: he actuator is connected with a standard modulating signal of DC 0...0V and drives to the position defined by the positioning signal. Measuring voltage serves for the electrical display of the damper position 0...00% and as slave control signal for other actuators. Operation on the -Bus: he actuator receives its digital positioning signal from the higher level controller via the -Bus and drives to the position defined. Connection serves as communication interface and does not supply an analogue measuring voltage. Connection option for a sensor (passive or active sensor or switching contact). he actuator serves as an analogue/digital converter for the transmission of the sensor signal via -Bus to the higher level system. he factory settings cover the most common applications. Single parameters can be modified with the Belimo Service ools MF-P or ZH E. he actuator can be directly connected with the application using the enclosed screws. he head of the gear rod is connected to the moving part of the ventilating application individually on the mounting side or with the Z-KS2 coupling piece provided. 2 LH24A-00-P en-gb 206-03-09 subject to changes www.belimo.eu

LH24A-00-P Product features Manual override Adjustable stroke High functional reliability Home position Manual override with push-button possible (the gear is disengaged for as long as the button is pressed or remains locked). If a stroke limitation will be adjusted, the mechanical operating range on this side of the gear rod can be used starting with an extension length of 20 mm and then can be limited respectively in increments of 20 mm by means of mechanical end stops Z-AS2. he actuator is overload protected, requires no limit switches in intermediate positions and automatically stops when the end stop is reached (at rest). he first time the supply voltage is switched on, i.e. at the time of commissioning, the actuator carries out a synchronisation. he synchronisation is in the home position (0%). he actuator then moves into the position defined by the positioning signal. 0 = 0 V = 0 V Adaption and synchronisation An adaption can be triggered manually by pressing the Adaption button or with the PC-ool. Both mechanical end stops are detected during the adaption (entire setting range). Automatic synchronisation after pressing the gearbox disengagement button is configured. he synchronisation is in the home position (0%). he actuator then moves into the position defined by the positioning signal. A range of settings can be adapted using the PC-ool (see MF-P documentation) Accessories Description ype Gateways Gateway to Modbus R, AC/DC 24 V K24MOD Gateway for BACnet MS/P, AC/DC 24 V K24BAC Gateway to LonWorks, AC/DC 24 V, LonMark certified K24LON Gateway to KNX, AC/DC 24 V, EIBA certified K24EIB Description Electrical accessories Signal converter voltage/current, supply AC/DC 24V Z-IC Digital position indicator for front-panel mounting, 0...99%, front mass ZAD24 72 x 72 mm Range controller for wall mounting, adjustable electron. Min./max. SBG24 angle of rotation limitation Positioner for wall mounting, range 0...00% SGA24 Positioner in a conduit box, range 0...00% SGE24 Positioner for front-panel mounting, range 0...00% SGF24 Positioner for wall mounting, range 0...00% CRP24-B Connecting cable 5 m, A+B: RJ2 6/6, o ZH/ZIP-SB- ZK-GEN Connection cable 5 m, A: RJ 6/4, B: Free wire end, o ZH/ZIP- ZK2-GEN SB- -Bus power supply for actuators, AC 230/24V for local power ZN230-24 supply Connecting board bus suitable for wiring boxes EX-WR-FP..- ZFP2- Description Mechanical accessories End stop set for LH Z-AS2 Rotary support for compensation of transverse forces Z-DS Coupling piece M6 for LH, galvanised steel Z-KS2 erminal protection IP54 Z-P Cable sleeve for Ø 4-6 mm, suitable for strain relief NG 43235-0000 Strain relief bushing (cable sleeve) for Ø 6-8 mm, suitable for strain 43235-00002 relief NG Cable sleeve for Ø 8-0 mm, suitable for strain relief NG 43235-00003 ype ype www.belimo.eu LH24A-00-P en-gb 206-03-09 subject to changes 3

LH24A-00-P Accessories Service ools Description Service ool, for MF//Modbus/LonWorks actuators and VAV- Controller Belimo PC-ool, software for adjustments and diagnostics Adapter to Service ool ZH ype ZH E MF-P MF-C Electrical installation! Notes Connection via safety isolating transformer. Parallel connection of other actuators possible. Observe the performance data. Wiring diagrams AC/DC 24 V, modulating Operation on the -Bus DC (0)2 0 V DC 2 0 V Sensor Functions Functions when operated on -Bus Connection on the -Bus Network topology + A) Connection of active sensors A) more actuators and sensors (max.8) Connection of external switching contact here are no restrictions for the network topology (star, ring, tree or mixed forms are permitted). Supply and communication in one and the same 3-wire cable no shielding or twisting necessary no terminating resistors required + p + A) A) A) more actuators and sensors (max.8) Supply AC/DC 24 V Output signal DC 0...0 V (max. DC 0...32 V) Resolution 30 mv A) more actuators and sensors (max.8) Switching current 6 ma @ 24 V Start point of the operating range must be parameterised on the actuator as 0.5 V 4 LH24A-00-P en-gb 206-03-09 subject to changes www.belimo.eu

LH24A-00-P Functions Connection of passive sensors + A) Ni000 28...+98 C 850...600 Ω 2) P000 35...+55 C 850...600 Ω 2) NC 0...+60 C ) 200 Ω...60 kω 2) A) more actuators and sensors (max.8) ) Depending on the type 2) Resolution Ohm Functions with basic values (conventional mode) Override control with AC 24 V with relay contacts Override control with AC 24 V with rotary switch a b c (DC 0...0 V) 0% ZS 50% 00% (DC 0...0 V) e.g. N 4007 0% ZS 50% a b c e.g. N 4007 00% Remote control 0...00% with positioner SG.. Minimum limit with positioner SG.. Z 2 3 4 SGA24 SGF24 SGE24 Z 2 3 4 SGA24 SGF24 SGE24 0 [V] (DC 0...0 V) min 0 [%] 0 00 Follow-up control (position-dependent) Position indication DC (0)2 0 V DC 2 0 V ZAD24 2 3 4 ) ) Adapting the direction of stroke www.belimo.eu LH24A-00-P en-gb 206-03-09 subject to changes 5

LH24A-00-P Functions Control with 4...20 ma via external resistor Functional check 500 Ω ( ) (+) 4 20 ma DC 2 0 V Caution: he operating range must be set to DC 2...0 V. he 500 Ω resistor converts the 4...20 ma current signal to a voltage signal DC 2...0 V Procedure. Apply 24 V to connection and 2 2. Disconnect connection 3: - for direction of stroke 0: Actuator travels in the direction retracted - for direction of stroke : Actuator travels in the direction extended 3. Short circuit connections 2 and 3: - Actuator runs in the opposite direction Functions for actuators with specific parameters (Parametrisation with PC-ool necessary) Override control and limiting with AC 24 V with relay contacts Override control and limiting with AC 24 V with rotary switch a b c d e (DC 0...0 V) Close ) MIN ZS MAX Open (DC 0...0 V) e.g. N 4007 Close ) MIN ZS MAX Open a b c d e e.g. N 4007 ) Caution: his function is only guaranteed if the start point of the operating range is defined as min. 0.5 V. Control open-close Control 3-point a b e.g. N 4007 a b 0 0 6 LH24A-00-P en-gb 206-03-09 subject to changes www.belimo.eu

LH24A-00-P Operating controls and indicators 4 Adaption Adress 5 0 2 Power 3 Status Direction of stroke switch Switch over: Direction of stroke changes 2 Push-button and LED display green Off: No power supply or malfunction On: In operation Press button: riggers stroke adaptation, followed by standard mode 3 Push-button and LED display yellow Off: Standard mode Flickering: communication active On: Adaptation or synchronising process active Flashing: Request for addressing from master Press button: Confirmation of the addressing 4 Gear disengagement button Press button: Gear disengages, motor stops, manual override possible Release button: Gear engages, synchronisation starts, followed by standard mode 5 Service plug For connecting parameterisation and service tools Check power supply connection 2 Off and 3 On Possible wiring error in power supply Installation notes! Notes If a rotary support and/or coupling piece is used, losses in the actuation force losses are to be expected. Applications without transverse force Applications with transverse forces he linear actuator is screwed directly to the housing at three points. Afterwards, the head of the gear rod is fastened to the moving part of the ventilation application (e.g. damper or slide valve). Connect the coupling piece with the internal thread (Z-KS2) to the head of the gear rod. Screw the rotary support (Z-DS) to the ventilation application. Afterwards, the linear actuator is screwed to the previously mounted rotary support with the enclosed screw. Afterwards, the coupling piece, which is mounted to the head of the gear rod, is attached to the moving part of the ventilating application (e.g. damper or slide valve). he transverse forces can be compensated for to a certain limit with the rotary support and/or coupling piece. he maximum permissible swivel angle of the rotary support and coupling piece is 0, laterally and upwards. Service Service ools connection he actuator can be parameterised by ZH E via the service socket. For an extended parameterisation the PC tool can be connected. AC 24 V DC 24 V SB ZH E i esc OK BELIMO PC-ool SB www.belimo.eu LH24A-00-P en-gb 206-03-09 subject to changes 7

LH24A-00-P Dimensions [mm] Dimensional drawings 25 97 68 6.5 35 94 264.2 67 22.5 4...0 4 3.2 233.5 Further documentation Overview Cooperation Partners ool connections 8 LH24A-00-P en-gb 206-03-09 subject to changes www.belimo.eu