Guide for using HddSurgery head change tools:

Similar documents
Guide for using HddSurgery head change tools:

Guide for using HddSurgery head change tools:

Guide for using HddSurgery head change tools:

Guide for using HddSurgery head change tools:

Guide for using HddSurgery head change tools:

Lab 4: Trajectory Following 1

Instructions for SVC-KIT-0020

A5000 2Mb RAM Upgrade Fitting Instructions

HP Photosmart c3180 Main Circuit Board Replacement

Product Development Rev II

EN-CAUH-B. Enclosure. Assembly Guide

Figure 4-29 Removing the CPU compartment cover

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

Installing the Server into a Rack

Canon PowerShot SD500 Digital ELPH LCD Replacement

EasyIO FG-32 Installation Guide v1.2. FG-32 Installation Guide

LG Chocolate Touch VX-8575 Side Buttons Replacement

imac Intel 21.5" EMC 2389 Stand Replacement

Disassembly / Assembly Acer Aspire 5315

JLTX Lever and Joystick Replacement Instructions

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1

Oracle <Insert Picture Here>

Apple 3.5 Drive External Floppy Drive

Mag EraSURE TM Professional Value Product Manual

Mac Mini Mid 2011 SSD Dual Drive Installation

Removal and Installation8

To connect the AC adapter:

LG Chocolate Touch VX-8575 LCD Screen

MacBook Core 2 Duo Display Replacement

SMART FORCE AND TORQUE SENSORS. User s Guide

MacBook Pro 17" Unibody AirPort Board Replacement

HP Pavilion dv7-6c90us Cooling fan Replacement

Printhead Replacement and Adjustment Guide for the CD Printer Revision B

Mac mini Late 2014 Power Supply Replacement

ML MLT-D104S TONER CARTRIDGE REMANUFACTURING INSTRUCTIONS

Sony Alpha 5100 Teardown

Written By: Allie Menard

Print Head Replacement and Adjustment Guide for the CD Printer Revision C

VMC Touch: Mounting Monitor Bracket Ports Connection And Cables Installation

HP ProLiant MicroServer

Written By: Walter Galan

Written By: Brittany K

Adding or Replacing a PCI Card

LNS-S10/LNS-T10/LNS-W10/LNS-T11/LNS-W11

Dell PowerEdge R940. Upgrading the dual processor to quad processor system

Sony Xperia XZ Premium Motherboard Replacement

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

C-pan arm USERS INSTRUCTIONS

HP ProLiant DL165 G7 Server

SMART FORCE AND TORQUE SENSORS. User s Guide

V5420 Host Card Upgrade Kit for R3082D Quick Start Guide

Dell Inspiron XPS and Inspiron 9100 Service Manual

HP ENVY Rove 20-k014us Ram Replacement

User Manual THALES SIMPLICITY II

Central Processing Unit (CPU) Replacement

MacBook Core 2 Duo Clutch Cover

ASSET LGA1366 Top-side Probe

Samsung Galaxy S4 Front Facing Camera

Upgrading and Servicing Guide

HP rp5700 Repair Central Processing Unit(CPU) Replacement

Toshiba Satellite A105-S4011 Touchpad

Removing and Replacing Parts

Upgrading and Servicing Guide

Installing imac Intel 27" EMC 2390 Dual HDD or

Xbox Motherboard Replacement

Setup Information Panosaurus May 3, 2011

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

SPARE PARTS & HOW TO HANDLE. μ-icc 2.45 compact. - Instructions - S/N: A01-PG10-SPE Version No.: 0 V

CRESCENDO /PB G3. Processor Upgrade Card for Macintosh PowerBook 1400 Series Computers. Quick Start Guide for Crescendo/PB G3

EasyIO FG-20 Installation Guide v1.1. FG-20 Installation Guide

Written By: Nicole Welter

Dell Inspiron N5110 Service Manual

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

How to add a Second Drive to a Mac mini (2012) using the OWC Data Doubler SSD/2.5 Installation Kit

MBX INSTRUCTION MANUAL. Please read this manual carefully before using the MBX! Mid-range studio stand

Page. Foreword. We sincerely hope that you enjoy using our product! P2 - INDEX

2015 SIMMCONN LABS, LLC. All rights reserved. NewScope-T1 Operation Manual

Replacing/Upgrading Mac Pro Processors (Early 2008)

OPTRON mobile. User Guide. magnified vision. Vers. 2.1AL Magnified Vision, Inc. 2013

imac Intel 27" EMC 2309 and 2374 Hard Drive

BROTHER HL TN TONER CARTRIDGE REMANUFACTURING INSTRUCTIONS

5000, 7000 Series StorSimple Appliance. Rack Installation Guide

FUSION R800RAID. 8-Bay Serial ATA Disk Array Storage System. Drive Enclosure User s Guide

Xbox DVD Drive Disassembly

Removal and Installation 8

Page

Instructions to Install Retrofit Kit 6/7000 Machine

Samsung Galaxy Tab Motherboard

How to replace the memory card slot board and DVD drive DIGITAL PHOTO PRINTER UP-CR20L

GbX Backplane and Daughtercard Tooling. *GbX is a Trademark of Teradyne Inc.

User Guide for NUC7i3DNHNC. Intel NUC7 Business, a Mini PC with Windows 10 NUC7i3DNHNC. User Guide

imac Intel 27" EMC 2390 Hard Drive

Removing the Battery. 2.Disassembly. Disassembly. Figure 1 Battery Removal. Removing the Battery 2-5

Instruction Manual. B1 Series. Copyright 02/02 Motic Microscopes, European Division

Packard Bell Vibe 300 Disassembly Manual

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide

Asus G53JW-A1 CD/DVD Optical Disk Drive

Dell OptiPlex All-in-One. Stand Installation Guide

Replacement Instructions

Nintendo DS Lite Rear Display Bezel Replacement

Transcription:

Page 1 of 15 Guide for using HddSurgery head change tools: HDDS Sea 7200.11/ES.2 p2 (2 platters) HDDS Sea 7200.11/.12/LP/ES.2 p3-4 (3 or 4 platters)

Page 2 of 15 Table of contents: 1. Introduction.. page 3 2. HddSurgery head change tools page 4 3. Supported models page 5 4. Head replacement process (10 steps) Step 1 - Handling the tool page 6 Step 2 - Mounting the tool on actuator arm page 7 Step 3 - Lifting the heads. page 8 Step 4 - Securing the tool. page 9 Step 5 - Moving the tool outside of platters area... page 10 Step 6 - Unscrewing the heads. page 11 Step 7 - Mounting the heads in a new drive page 12 Step 8 - Removing the securing pin.. page 13 Step 9 - Removing the tool outside of platters. page 14 Step 10 - Dismounting the tool page 15

Page 3 of 15 1. Introduction This guide is intended as a short course in handling of our tools for professionals in data recovery. It is assumed that the user is experienced in data recovery and familiar with "traditional" ways of saving data. This manual should not be taken as a guide for training. Using these tools without adequate software support is not recommended. It is recommended to use some of the proven systems for cloning, such as Ace Lab, Salvation Data, Copy-r and other products. It is possible to recover data without HddSurgery TM tools. In many cases, the known processes of hard drive head replacement are effective and sufficient. The general idea behind HddSurgery TM tools was to make sure that the process of replacing damaged hard drive heads goes with no errors. The use of HddSurgery TM tools prevents the ferromagnetic read/write heads to come in any kind of contact with the platter i.e. disk surface or other read/write heads. Also, with some basic procedures and short training, it is possible to let junior data recovery technicians handle complex tasks. With the development of these tools, we are trying to eliminate the element of luck that usually accompanies the process of data recovery. Experienced data recovery technicians or engineers can have great success even without our tools, but they can have absolute security only by using HddSurgery TM tools. Non-contact head replacement implies that there is no contact between the heads, or between heads and platters in the process of dismounting the donor heads and mounting heads on the patient drive. Traditional techniques of replacing the heads imply contact between the heads and contact of heads with the platters in data area. These problems especially come to light on drives that have suffered some form of physical damage. A donor selection process is not covered by these guidelines. If you have questions about compatibility, you can send them to HddSurgery TM support team on HddSurgery TM is not responsible for any eventual damage caused by usage of our tools. HddSurgery TM is not responsible for the data stored on the patient or donor hard drives.

Page 4 of 15 2. HddSurgery head change tools Seagate hard drives belong in the category of disks that "park heads" above the magnetic platters. That way of functioning implies that, in a situation when the drive is powered off, the heads are located on the surface that has no sensitive magnetic material. This allows drive to start the motor to the required speed. The purpose of HddSurgery TM head change tools is to enable safe heads passage over the "data" area above platters surface, and to provide non-contact transfer to patient disc. HDDS Sea 7200.11/ES.2 p2 (2 platters) This head change tool is made for safe and easy head replacement on Seagate 7200.12, Seagate 7200.11, Seagate LP and Seagate ES.2 drives with 2 platters. HDDS Sea 7200.11/.12/LP/ES.2 p3-4 (3 or 4 platters) This head change tool is made for safe and easy head replacement on Seagate 7200.11, Seagate LP and Seagate ES.2 drives with 3 or 4 platters, and on Seagate 7200.12 and Seagate LP drives with 2 platters. As there is no conceptual difference between these two tools, we will explain only the functioning of HDDS Sea 7200.11/.12/LP/ES.2 p3-4 tool. In the case of HDDS Sea 7200.11/ES.2 p2, apply the same procedure. During the whole procedure of head replacement, heads and platters do not have contact. Heads are lifted over NON-data area and safely guided over the platters. In process of installing back the donor head same procedure needs to be done. Heads are guided over platters with no contact and safely deployed in non-data area.

Page 5 of 15 3. Supported models HDDS Sea 7200.11/ES.2 p2 (2 platters) SATA ST3500320AS ST3500620AS ST3500820AS ES.2 SATA ST3500320NS ES.2 SAS ST3500620SS HDDS Sea 7200.11/.12/LP/ES.2 p3-4 (3 or 4 platters) SATA ST32000542AS ST31500341AS ST31500541AS ST31000333AS ST31000340AS ST31000640AS ST31000520AS ST31000524AS ST31000528AS ST3750330AS ST3750630AS ST3750525AS ST3750528AS ST3640323AS ST3640623AS ES.2 SATA ST31000340NS ST3750330NS ES.2 SAS ST31000640SS ST3750630SS

Page 6 of 15 4. Head replacement process Step 1 Handling the tool When not in use, the tool should always be kept in a wooden box delivered with the tool. This way of keeping the tool prevents any possible damage to it which could appear when not handled correctly. When taking the tool out of the box, always hold it for the shank. Never hold the tool in the part where the head lifting snouts are. Due to sensitivity of hard drive platters to dust and any kind of contamination, be sure to clean the tool before it s use. Tool can be cleaned with a piece of cotton wool and alcohol. When cleaning the head lifting snouts, be extremely gentle. Picture 1. (handling the tool )

Page 7 of 15 Step 2 - Mounting the tool on actuator arms Unscrew and remove the screws that are holding flat cable contact and, using a finger, push the connector from the bottom upwards to release it. The pressure from below may cause this connector to pop out and possibly damage the platters. Because of this, hold the top of the connector firmly with one hand, while pushing it from below with another. Carefully center the tool over the axle hole of the hard disk head arm. Take care that the notch on the bottom of the tool coincides with the commas in the actuator arm base. Place a screw through the tool s shaft and tighten it to connect the tool to the head arm. Picture 2. (mounting the tool ) While tightening this screw, hold the tool with your hand and make sure that its shank with snouts remains in the area outside of the platters.!!! IMPORTANT!!! Be sure to tighten the mounting screw because this will ensure a good contact and proper tool height.

Page 8 of 15 Step 3 - Lifting the heads By horizontally moving tool shank we slide the tool over platters. Construction of the tool enables its snouts to lift the heads by using a relatively small force. If you feel that the necessary force is greater than expected, check the tool s position and possible damage to the HDA assembly. Push the tool until its snouts lift the heads as far as the limiter is allowing. Picture 3. (lifting the heads)

Page 9 of 15 Step 4 - Securing the tool The tool has a hole at its edge, which coincides with the hole in the head arm. The leftmost position of the tool is necessary to ensure the bound between the tool and actuator arm. Securing of the tool is done by using the securing pin. Picture 4. (securing the tool)!!!important!!! If the connection of the tool and actuator arms is not properly engaged, heads might slip from snouts during the disassembly.

Page 10 of 15 Step 5 - Moving the tool outside of platters area ` By vertical scrolling move the tool (previously secured by pin) to the initial position. Picture 5. (moving secured tool with heads outside of platters area)

Page 11 of 15 Step 6 - Dismounting the heads In order to dismount the heads from the hard drive, unscrew the screw at the bottom of the hard drive that s holding the actuator axis connected to the casing. While unscrewing this screw, hold the tool outside of the platter area with your other hand. Turn the screwdriver counter-clockwise until heads are free. Picture 6. (dismounting the heads)

Page 12 of 15 Step 7 - Mounting the heads in a new drive Place the tool with heads to its place in a patient hard disk. Screw the arm from the bottom side of the hard disk. After this, tighten the screw that s holding the tool and head arm connected too, just in case it got loosen up during the manipulation. This operation is necessary because of possible changes in height! Picture 7. (mounting the heads on a patient drive) By horizontal force return the heads back towards the central section of the platters.

Page 13 of 15 Step 8 - Removing the pin Carefully remove the securing pin when heads are above the parking zone. Picture 8. (remove the securing pin)

Page 14 of 15 Step 9 - Removing the tool outside of platters Using a finger push the tool shank horizontally to move the tool outside of the platter area.!!! IMPORTANT!!! With your other hand, hold the back side of the head arm (magnetic coil) to prevent heads from moving. Picture 9. (returning the tool outside of platters)

Page 15 of 15 Step 10 - Dismounting the tool Take out the screw and remove the tool. While unscrewing the screw, use the assisting tool to make counter-force. Picture 10. (removing the tool, using the assisting tool) Put the lid back and close the disk. Put PCB back and start cloning the drive. You can find more information about this tool and many other tools used for data recovery on our website. http:/// Also you can watch the videos that show how this tool works on our YouTube channel. http://www.youtube.com/user/hddsurgery