MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION INSTRUCTION MANUAL FMX-125

Similar documents
OPERATOR MANUAL OSD730 FULL DUPLEX FOUR CHANNEL DIGITAL AUDIO/DATA SYSTEM

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

The AMG5715A1B9 is designed to be powered using an AMG2001 standalone power supply.

Instruction Manual RR-915C Video Receiver With Bi-directional Multi-Protocol Data And Bi-directional Contact Closure

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER

OPERATOR MANUAL OSD420 SERIES VIDEO, AUDIO AND DATA FIBER OPTIC TRANSMISSION SYSTEM

HD-3500 Series. HD Video, Audio, Data & Tally/GPIO Channels FEATURES

CFO100 Series. User Manual CRT141 & CRR141. CFO141 User Manual, , rev001

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

Mini4 Data Mux User s Manual. ( xxx) And. Troubleshooting Guide

LASER PLUS OPERATING INSTRUCTIONS

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

Instruction Manual RT-91685SL RR-91685SL Sixteen Channel Video Multiplexer With Two Bi-directional Data Channels

L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL

OPERATOR MANUAL OSD8826 SERIES DIGITAL VIDEO AND DATA FIBER OPTIC TRANSMISSION SYSTEM

Precise Fiber Couple Laser Light Source

OPERATOR MANUAL OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM

Single Channel FM Video Transmission System 850 nm Multimode Low Profile

HD-CVI / AHD / HD-TVI Video + Bi-Directional Data

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

VCL-TP, Teleprotection Equipment

Optimux-34 Fiber Optic Multiplexer

OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE

Single Channel Video Insert Unit with Bi-directional Data Channel for a Dual Redundant fibre ring

Fiber optic converter audio and CAN TA OPERATION MANUAL

OTEB-CO-B Series. Booster EDFA OPERATING MANUAL

Table of Contents. Functional Description Installation Power Source Power Connection Fiber Connection... 4

Blue LED Pulsed Light Source LS-475. Installation and Operation Manual Document Number

OPERATOR MANUAL. OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER. WITH PoE SOURCE

SPECIAL SPECIFICATION 1303 Lifelink

OPERATOR MANUAL OSD840 SERIES DIGITAL VIDEO, ETHERNET, DATA AND AUDIO FIBER OPTIC TRANSMISSION SYSTEM

OPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM

6100E Series DIGITAL FIBER OPTIC MULTI-CHANNEL AUDIO TRANSPORT SYSTEM

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc.

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

2 Channel POTS with I/O DIN Fiber Link System

PLD Series +5V Laser Diode Drivers

Model 7705 Control Module

Serial Data DIN Fiber Link System

MODEL 805 USER MANUAL

Multicom 1550nm High Power Erbium Doped Fiber Amplifier MUL 2RU EDFA 1550 XX xx

Resolver to Digital Expansion Board

RS-232 Industrial Media Converter

2 Channel POTS DIN Fiber Link System

Installation and Operation Manual Document Number

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

Optimux-4T1 Four-Channel T1 Multiplexer

Data Isolation Cards. ADSL High Voltage Isolation Card. Single Line Voice Isolation Card With CID, CW & MWI. Floated 130VDC or 120VAC Input P30121

OPERATOR MANUAL OSD860 SERIES DIGITAL 2/4/8 CHANNEL VIDEO/AUDIO/DATA/IP FIBER OPTIC MULTIPLEXER

PSW-002. Fiber Optic Polarization Switch. User Guide

OTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL

Audio Interface Quick start guide

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

INSTRUCTION MANUAL HIGH CURRENT DRIVER BOARD STAND ALONE

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

Models 1417 and 1437 User s Manual. High-Speed Photodetector Modules

APPLICATION NOTE DD-100

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

SPECIAL SPECIFICATION 6230 Fiber Optic RS-232 Data Modem

USER MANUAL SES-FA4BAL

Optical Loss Budgets

MUSIC SERVER SERVICE MANUAL CONTENTS

8 Channel Video Receive Unit with 2 Bi-directional Data and Audio Channels plus Ethernet for a Dual Redundant multimode fibre ring.

KFC-200. Installation Guide

Media Converters. Media Converters. Product Selection Guides

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

10/100 Ethernet Converter xxxxx and xxxxx OEM Board Version Users Manual And Installation Guide

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

OG COMMS USER MANUAL OG COMMS

OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM

FIBER OPTIC TRANSMISSION SYSTEM 3730 & 3530 SERIES. Digital Video with Bi-directional/Return Data. User Manual. Infinova

Installation and Operation Manual Document Number

RS-422/485 to Fiber Industrial Converter

Industrial 3-Port Fast Ethernet Media Converter Switches

Fiber Optic and CAT 5-6 Installer Premise Cabling

RS-232 Fiber Link Card System

Data Insert Unit with 2 Bi-directional Data Channels for a Dual Redundant Singlemode Fibre Ring

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

EOS-6000 Series Optical A/B Switch User Manual DC Version

HRS-1S. Half Rack Analog Stereo Audio Speaker Monitor. User Guide. Part Number , Revision E

LBO-DVI-EAD LINK BRIDGE TM FIBER OPTIC DVI WALL PLATE AND STANDALONE TRANSMITTER SYSTEM

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

CH 2 CH 1 BALANCED INPUTS

OLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide

Instruction Manual MT-984C-SL Eight Channel Digital Transmitter With RS485, RS-422, RS232 or Manchester Data

ADAM Fiber Optic to RS-232/422/485 Converter

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Neve 8803 Dual EQ User Manual

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

The AMG5716A9 is designed to be powered using an AMG2001 standalone power supply.

This provides an easily configurable solution, flexible enough to meet the specific requirements of a broad range of applications.

Optimux-34, Optimux-25

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

BU400,BU400B,UB400B, UB400B, & BI400

HDMI Optical Extender USER MANUAL VE882 / VE892

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS. KC-300DM Series. Installation Guide

A Watt Stereo Amplifier

Transcription:

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION INSTRUCTION MANUAL FMX-125 FIBER OPTIC, BI-DIRECTIONAL DATA, CONTACT CLOSURE and AUDIO MULTIPLEXER SYSTEM Revision: 0, Date: October 28, 2013 MULTIDYNE Electronics, Inc. Innovations in Television Testing & distribution 1-(800)-4TV-TEST, 1-(800)-488-8378 191 FOREST AVENUE LOCUST VALLEY, NY 11560-2132 USA (516)-671-7278 FAX (516)-671-3362

2 MULTIDYNE, FMX-125 is registered trademarks of MULTIDYNE Electronics, Inc. Copyright 2008 MULTIDYNE Electronics, Inc., Locust Valley, New York. Printed in the United States of America. All Rights Reserved. Contents of this publication may not be reproduced in any form without the written permission of MULTIDYNE Electronics, Inc. This product was designed and manufactured in the UNITED STATES of AMERICA TABLE OF CONTENTS INTRODUCTION 4 OPERATION AND CONNECTIONS 4

3 BASIC FUNCTIONALITY 4 FMX-125 OPERATION 4 FMX-125 AUDIO OPTION 4 CIRCUIT DESCRIPTION 5 TRANSMITTER SECTION 5 RECEIVER SECTION 5 INSTALLATION AND PRECAUTIONS 5 OPTICAL PRECAUTIONS AND REQUIREMENTS: 6 INSTALLATION: 6 MOUNTING, POWER AND INSTALLATION REQUIREMENTS 7 SPECIFICATIONS 7 ELECTRICAL 7 OPTICAL 7 DRAWINGS 7

Instruction Manual, FMX-125 INTRODUCTION 4 INTRODUCTION The Multidyne FMX-125 Series of Fiber Optic Multiplexers support transport of twelve bidirectional RS-232 or RS-422/485 data channels, with the option of up to two audio or intercom channels. It also supports 8 dry contact closures.!!!!!! DANGER!!!!!! INVISIBLE LASER RADIATION AVOID DIRECT EXPOSURE TO BEAM OUTPUT POWER MAX: 2 mw. WAVELENGTH: 1300/1550 NM. CLASS III b LASER The optical laser transmitter may harm the human eye. Proper eye protection should be used at all times when working with laser. Please read the entire manual before operating the Fiber Optic devices. WARNING VOLTAGES INSIDE The unit should be only serviced or opened by qualified personnel. There are no user serviceable parts or adjustments inside. OPERATION and CONNECTIONS BASIC FUNCTIONALITY FMX-125 OPERATION The FMX-125 has 12 bi-directional RS-232 or RS-422/485 channels and 8 dry contactclosure channels. The data I/O s are connected through the 68 pin high density SCSI connector to a screw terminal adapter/breakout board. A SCSI cable is used to connect the data portion of the breakout board to the FMX-125. The contact closure relays and screw terminals for same are on the breakout board. The contact closure portion of the breakout board connects to the FMX- 125 via a DB9 cable. Do not use a standard RS232 cable for this, as the pins may not be connected one-for-one. Use only a cable that has all 9 pins connected individually one for one. SCSI and DB9 cables are available from Multidyne. You ll need 2 FMX-125s and 2 breakout boards, plus cables, to form a complete link. FMX-125 AUDIO OPTION If the FMX-125 is equipped with the audio/intercom option, the audio inputs and outputs are found on RIA connectors on the breakout board. By connecting a headset/microphone to them, it becomes an intercom link with side tone.

Instruction Manual, FMX-125 OPERATION and CONNECTIONS 5 CIRCUIT DESCRIPTION TRANSMITTER SECTION All data, contact closure and audio inputs are through the rear panel connectors. A breakout board with screw terminals connects to the FMX-125 with a SCSI cable for data and contact closure control. The RS-422/485 or RS-232 inputs are converted to TTL by data convertors. A parallel to serial convertor (SERDES) converts the 8 control and 12 TTL data channels into one serial bit stream which is outputted to a fiber optic transceiver module, modulated onto the fiber and sent to the other FMX-125. The optional audio input is through the 68 pin SCSI connector from a headset mic attached to the screw-terminal adapter breakout board. The analog audio is then sent to a PCM (pulse code modulated) CODEC, where it is modulated into a TTL digital bit stream. The digital audio bit stream is then sent to the SERDES as described above. RECEIVER SECTION The optical data is received by a fiber optic transceiver, demodulated and sent to a serial to parallel convertor (SERDES) where it is de-multiplexed into the 12 TTL data channels and 8 contact closure controls. The TTL channels are converted back into RS- 232 or RS-422/485 data by data convertors. The data is then outputted through the 68 pin SCSI connector and the relay controls via the DB9 connectors to the breakout board. In the case of audio, the TTL audio data from the SERDES is sent to a PCM CODEC, and converted back into analog audio. It is sent to the breakout board via the SCSI connectors. INSTALLATION and PRECAUTIONS

Instruction Manual, FMX-125 OPERATION and CONNECTIONS 6 OPTICAL PRECAUTIONS and REQUIREMENTS: Extreme caution should be used when handling Laser equipment. Appropriate eye protection should be worn at all times. Direct exposure to the eyes and skin can be harmful. The audio, data and optical connections can be found in the sections above. There are no user serviceable parts or adjustments inside the system. The only user controls and interfaces are present on the front and rear panels. If service or calibration adjustments are necessary, please return the system to the factory. When installing a 1300nm Singlemode Laser system the launched optical power can vary from -10 dbm to +3 dbm depending on the model purchased. The receiver will compensate for variations in optical attenuation. If the systems are used over very short distances with minimal optical attenuation, the receiver may become over loaded. In this case, an external optical attenuator should be used: For a 1300 nm Laser System, use a -5 to -10 dbm attenuator for short distances. The FMX-125 for Singlemode applications all have an optical window from the wavelength of 1100 to 1600 nm. If a Singlemode system is to be Wave Division Multiplexed with other optical wavelengths in the 1100 to 1600 nm range, the appropriate optical filters and wave division multiplexers should be used. The user may contact MULTIDYNE to purchase such devices. The optical fiber should be free of defects or flaws. The optical fiber should not have any excessive bends or micro-bends as this will attenuate or cause optical power to be lost. Proper splicing and connectorization techniques should be used. Improperly assembled, cleaved and polished optical connectors can cause significant optical losses and reflections. All optical connectors should be inspected with a microscope for cracks, chips or any blemishes on the optical surface. INSTALLATION BREAKOUT BOARD The DB9 and SCSI connections to the FMX-125 are on the rear of the board. The breakout board front panel is divided into several sections, from left to right: 1. Jumpers for 100 ohm terminations for the data inputs. There is a jumper for each of the 12 data channels. Place a jumper in the on position if RS422/485 is used for that channel. 2. Screw terminals for the 12 data inputs to the breakout board. There are 3 rows, from top to bottom: Ground, inverting input, non-inverting input for each channel. When using RS232, use only the ground and inverting connections. If an input is RS422/485, set its corresponding termination jumper accordingly. 3. Screw terminals for the 12 data outputs. There are 3 rows as above. 4. Balanced audio inputs and outputs. The AUOx labels refer to audio output; the AUIx labels refer to audio input, where the x denotes the channel. The G label is ground. If your audio is unbalanced, connect to the non-inverting audio terminal and ground.

Instruction Manual, FMX-125 SPECIFICATIONS 7 5. Screw terminals for contact closure control inputs. Apply TTL logic 1 to close relay. 6. Screw terminals for the 8 dry contact closures. The contact closures are to a common return, which is floating. FMX-125 SETTINGS The front panel of the FMX-125 has level adjustments for the 2 audio channels. These are for receiver audio output level. Adjust to personal taste. There are dip switches to set the data protocol for each of the 12 data channels. Set the switch for each channel to either RS422/485 or RS232. Be sure the termination jumper selections on the breakout board are consistent with the switch settings on the FMX-125 connected to it. Normally, for a given channel, you would select both ends of the link to have the same protocol, but this is not necessary if you want to use the link to convert from one protocol to another. MOUNTING, POWER and INSTALLATION REQUIREMENTS The fiber optic system dissipates a significant amount of heat due to the high-speed circuitry and optics. The units should have adequate ventilation. The units are powered by a desktop universal-input supply. ELECTRICAL SPECIFICATIONS Power Requirements:... 100-250 VAC @ 0.8A Max. with desktop supply Input and Output Level:... Audio: 0 dbm (+10dBm) Input and Output Impedance:... Audio: High or 600 Ohms, 22 ohms respectively Bandwidth:... Audio: 100 Hz to 8 KHz (standard) Data: DC to 230KBaud Data:... Standard RS-232 or RS-422/485 Contact closure control: 5 volt TTL/CMOS compatible OPTICAL Optical Wavelength:... 850 nm and 1300 nm Multimode 1300 nm Singlemode Optical Budget... >19 db for 850 nm MM, 62.5 µ >15 db for 1300 nm MM, 62.5 µ >28 db for 1300 nm SM, 8.3 µ Sensitivity... >-28 db MECHANICAL Portable and Wall-mount:... 7 L x 5 ¾ W x 1 ¾ H Triple Rack-mount Kit for 3 modules (Part number -RMT):... 7 L x 19 W x 1 ¾ H DRAWINGS

Instruction Manual, FMX-125 DRAWINGS 8 Sheet 1: SCSI and DB9 Connector wiring

Instruction Manual, FMX-125 DRAWINGS 9 Sheet 2: Mechanical