Target Interface / Construction Compliance Inspection Checklist

Similar documents
Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist

General. Exterior Cameras. Camera Towers

Computer Network Design Guide Existing Systems 1 / 6

Installation Notes TII Model 341 Protector

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

MICHIGAN DEPARTMENT OF TRANSPORTATION

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

alid portable power cart epcc panel ccts EPCC-60 40" 60A, 120/208V 3PH 24 EPCC " 100A, 120/208V 3PH 24

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

MICHIGAN DEPARTMENT OF TRANSPORTATION

Installing the Cisco AS5400XM Universal Gateway

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet

Spring Test 9 due 05/11/2013

ICS Entrance Management Sign Installation Guide. Version 1.0

The six major components of a structured wiring system are:

Communications Site Installation R56 Installer and Communications Site Inspector/Auditor version COMPETENCY REQUIREMENTS

Tarleton State University. Specifications

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA

MODELS PD230 AND PD1230 Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Site Preparation CHAPTER

PXC Compact Unitary Equipment Controller (UEC)

Haworth Power Technical Sheets January 2018

Spring Test 16 due 06/14/2013

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

Lightning Protection and Grounding Guidelines

Installation Manual. Table of Contents

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

SECTION PANELBOARDS

Power-Over-Ethernet Weatherproof 18" x 16" x 8" Enclosure with Equipment Mounting Plate and Cooling Fans

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017.

Government of Prince Edward Island Structured Cabling Standards August 24, 2009

SECTION WIRING DEVICES

Outdoor Risk and Equipment Protection

Datasheet. Fiber Optic Modular Patch Panel Features

EATON Transformer Module

HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series

Los Angeles Community College District Design Standards

VRp Three-Phase Precision AC Voltage Regulator

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans and Solid State Fan Controllers Model: NB FS

NEC 2008 Code Changes Top 20 Revisions. By: Rafi Wartan, PE, LEED AP

PanelView Plus/VersaView CE Terminals and Display Modules

Emery County Senior Center Green River 06/07

10.0 Enclosures Enclosures. Integrated Routing Connectorised Fibre Enclosure 143. Integrated Routing Fibre Enclosure 144. Integrated Routing 145

Arca LED 5YEAR LED WARRANTY. Order Code: Pole Order Code: Customer: Date: Project: Qty: Type: ACL ACL. R2 Type II Distribution.

KTX REMOTE INSTALLATION INSTRUCTIONS

Metropolis ADM MultiService Mux Compact Shelf

Items Dimension(WxDxH) Max.Capacity Mounting P-FDB8 181X45X207mm 8 ports & splice Pole/Wall P-FDB16 220x80x300mm 16 ports & splice Pole/Wall

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

This Wiremold aluminum raceway system meets the

Meter Enclosure and Equipment Standards

Installing the ILC LightSync 4.3 or 7 Touch Screen Station. Rev. B

Spring Test 5 due 4/26/2013

SECTION WIRING DEVICES

Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate and Cooling Fan. Model: NB F. Applications and Features

Instruction / Installation Sheet DataComm Electronics WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

BEJED DISTRIBUTION PRODUCTS FAX:

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

COMPUTER NETWORK WIRING SYSTEMS FOR PLCs

SNAP Compact Fiber Optic Patch Panel

U-SERIES SPECIFICATION GUIDE

EP/2 Installation Instructions

Category 5e Solutions

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

RCC45 ➁ Overview / /

Data Cabling / Low Voltage Technology Specifications

ONE GANG WEATHERPROOF OUTLET BOXES - DIE CAST METAL BWF Product Benefits & Features B-5V DB-5V B5-2V. Applications

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE

Compact Series Wallmount Enclosures

4188, 4288, 4288-S and 4688 Protected Entrance Terminals

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

WIREMOLD Tele-Power Poles

SECTION PANEL WORK

This Special Provision refers to the following standards, specifications or publications:

SECTION WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

ADJUSTABLE FLOOR BOXES

Voice Integration Overview

Spring Test 17 due 06/14/2013

FIBER OPTIC HARDWARE STEVE PAULOV

Electrical Demand Specification (Reference SOP: )

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Cabinet

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

SmartLogger1000 Quick Guide. Issue: 10 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

Aerial Façade. Cabinets and borders. Butt and Sleeves Closures for manholes and handholes

PREVENTING DOWNTIME OF E911 CENTERS

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

Transcription:

A. Targets Quantities meet DD9, applicable TC 5-, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC 5-, and CEHNC Design Guide 0--. Note: Two tank trails per lane for armor ranges Trails and service roads provide adequate access to targets for maintenance C. Line of Sight Targets can be adequately seen from pertinent firing positions to allow 90% of target to be viewed Vegetation does not obscure target positions Left and right limit markers are outside greatest angle of fire from firing positions/points D. Testing Results-provided to the local government construction representative Secondary power cabling tests Data cabling tests including fiber optic and/or copper network (ie. Cat5e) Target berm compaction tests. Grounding tests results. Control building (ie. ROC) has 5 Ohms or less earth resistance E. Drawings Contract drawings are available on-site Date: Common Items "As-builts" will be made available to government representative after completed construction YES NO NOTES Page of

Date: A. Power Minimum 0V is provided via incoming service power. SPD is provided for the DTR and Range Control System (RCS) panelboard. Receptacles (0V, 0A) are provided for RCS and printer along front wall of control room under work table. Two dedicated circuits (0V, 0A) to two duplex or a quadplex receptacle are provided near DTR. B. Data Termination Rack (DTR) Control Tower DTR is an enclosed "Dx"Wx"H free standing rack with 9" rack frame. " space is available to front and rear and one side. DTR is located a minimum of " from the wall on the remaining side DTR rack is properly grounded to TMGB or a single point ground via a minimum # AWG insulated ground cable. "x" wireway is provided under the floor or along the side 5 wall from the DTR location to the RCS workstation located along the front wall. Data cabling from downrange is only a single type entering DTR (ie. fiber or Cat5e). Data cabling armor or shield is properly grounded as close 7 as practical to the point of entrance. Data cabling is properly terminated (ie. fiber-sc connectors, Cat5e-female RJ5 connectors). Copper cabling from downrange also has data network surge protection with V clipping voltage installed. Data cabling in DTR is neat and orderly and adequately 9 anchored. meter minimum service loop of data cabling is provided in 0 DTR. Data cables are be permanently tagged identifying destination (ie. SIT X or lane X). Fiber cabling has no visible microbending, pinching, or other marking to indicate fiber failure. Patch panels have labeling identifying each cable's destination. Buffer tube fanout kits and furcation units are installed and 5 adequately anchored in DTR. Conduits entering DTR are sealed to ensure moisture and rodents are kept out. Innerduct in conduits or spare conduits are provided from 7 the DTR to downrange. YES NO NOTES Page of

Date: Control Tower C. Department of Information Management (DOIM) DOIM cabling is not terminated or entering the DTR. RJ5 jacks for DOIM cabling are properly labeled and identified as "Common User". D. Miscellaneous Back wall of control room is windowless. Work table surface is " deep, the width of the tower and has a minimum of one slot for cable access. HVAC is provided in an appropriate location. Pull wires are provided in all empty conduits. 5 Lightning protection is provided and is properly installed. Red lights are provided on separate switching from other lighting. (Applicable if range is used for night firing). Limit marker switch is provided and labeled properly. Note: 7 Only provide limit marker switch on non-maneuverable ranges. YES NO NOTES Page of

A. Miscellaneous Emplacement size: Front wall height is ". Front wall length is 5". Floor width is 5". A minimum of 9" of clearance is provided to the rear of the emplacement allowing space for the target in the down position. Adequate space is available in emplacement for target mechanism. Berm fill is level with the top of the protective timber at the front of the emplacement and free of holes. 5 Emplacements are sloped to the rear for drainage. All emplacements and enclosures are clean of dirt and debris. All power and data enclosures are mounted no higher than 7 inches from top of wall. Target power outlet is () NEMA L-0R and () NEMA L5-0R with wet location covers. GFCI maintenance receptacle (0A, 0V) is provided with 9 an in-use weatherproof cover. All boxes and enclosures have weatherproof covers 0 installed A -foot free length coil of # AWG bare copper ground cable is provided above ground from the grounding rod for future bonding to target mechanism. Emplacement is permanently labeled (ie. SIT X) and power center panel schedule agrees with label. All data and power conduits are routed to the rear or side of emplacement. B. Loadcenter (LC) 0/0V is provided via feeder circuit. Size of LC is maximum "Hx"Wx"D. LC has SPD installed properly A pole 0A circuit breaker is provided for the target 5 power outlet. LC is properly grounded via a minimum # AWG bare copper ground cable to SIT ground rod. 7 Location of LC is adequate to allow lid to be opened. Date: Stationary Infantry Target (SIT) Panel schedule is provided which indicates circuit designations and where feeder circuit originates (ie. SIT X and panelboard PB-X) YES NO NOTES Page of

Date: Stationary Infantry Target (SIT) C. Master Target Data Panel (MTDP) and Target Data Panel (TDP) Size of MTDP is "x"x" - TDP is minimum "x"x" Type of MTDP/TDP enclosure is galvanized steel NEMA. NEMA rating is maintained after installation (ie. screws do not penetrate the enclosure). The gasket is one piece and seamless in the enclosure cover. Cable seal fittings are properly installed on cables entering MTDP/TDP from underground. Location of MTDP/TDP is adequate to allow lid to be 5 opened. A back plate is installed that covers the entire back of the MTDP/TDP. A 0"x0" space is available for target installer equipment 7 in MTDP. "x" space required in TDP. Data cabling is installed neatly and orderly and properly anchored or fastened in the MTDP/TDP. 9 Fiber cabling is armored and properly grounded. 0 Fiber is terminated with SC connectors. Fiber is permanently tagged and labeled (ie. To SIT X or From SIT X). Fiber SC connectors are terminated on a patch panel with number of ports to support total number of fiber strands terminated. Fiber patch panel is mounted to the back plate. Minimum meter service loop of fiber cabling is provided and properly secured inside MTDP. Fiber cabling has no visible microbending, pinching, or 5 other marking to indicate fiber failure. Fiber terminations allow adequate space for target installer to jumper to target installer equipment. Buffer tube fanout kit and furcation unit for the fiber cabling 7 is anchored or securely fastened. A standard duplex receptacle (0A, 0V) is mounted to the back plate and properly grounded. 9 The duplex receptacle is not GFCI protected. 0 Cat5e or better cabling is shielded and properly grounded. Each end of Cat5e shall be terminated on a data network surge protector with a 5V-0V clamping voltage. Each surge protector shall not be larger than 5"x5". Cat5e cable is terminated on a 0-block style modular outlet. RJ-5 connertor patch cable connects modular outlet to surge protector. MTDP/TDP is grounded to the target ground rod via # AWG bare copper ground cable. YES NO NOTES Page 5 of

A. Date: Miscellaneous Limit Markers Limit marker locations are visible from pertinent firing positions. Lighted or heated for night firing. Red lighting is used on the face of the limit marker or limit marker face is illuminated with white lighting shining upon it. 0V, 0A, duplex GFCI receptacle is provided near the base of the limit marker. Controls are provided. In the ROC for non-maneuverable range and locally at the LM or nearby location for maneuverable. Any ground light, receptacle, and control switch are located 5 or protected to avoid direct fire. YES NO NOTES Page of