Room Temperature Controllers

Similar documents
Room Temperature Controller

Room Temperature Controller

Semi flush-mounted room temperature controllers with LCD

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

Semi flush-mounted room temperature controllers with LCD

Semi Flush-mount Room Temperature Controllers with LCD

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

Room unit with PPS2 interface

RDF301 RDF CE1N3171en 02 Jun 2010 Building Technologies

Master room unit for RRV controllers

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

7-day room temperature controller

Temperature controller Ducted systems

Heating Circuit Controller

Room thermostat with KNX communications For VAV heating and cooling systems

7-day room temperature controller

Weekday / weekend room temperature controller

Non-communicating room controllers

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Heating Circuit Controller

Room unit with PPS2 interface

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Temperature Controller

Temperature Controller (Heat Pumps)

Weekday / weekend room temperature controller

Room unit with PPS2 interface

Room unit with PPS2 interface

Room thermostats with KNX communications

RDF Series Room Temperature Controllers

Immersion Temperature Sensors

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Room thermostats with KNX communications

Universal Controller

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Non-communicating room controllers

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Product and Application Description

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Compact Universal Controllers

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Temperature controller for multi-zone ducted systems

Temperature controller Multi-zone ducted systems

24-hour room temperature controller

Heating Controllers. Siemens Building Technologies HVAC Products. Synco 700

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

UCU Room Display. Operation Modes. Features. Applications DATASHEET

Electrical Actuators

ERF910. RF Repeater. Synco living

Electrical Actuators

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Electrical Actuators

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

M-Bus Central Unit. Use

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

QMX3.P30 QMX3.P70 QMX3.P02 QMX3.P34 QMX3.P74 QMX3.P37. Wall-mounted sensors and room operator units for KNX PL-Link, KNX S-mode and KNX LTE-Mode

Wall-mounted room thermostats with LCD

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

Pre-programmed room controller with display and communication

Power supply module, bus connection module

Communicative controller for VAV systems

TC-8900 Controller Units with PM-8900 Power Modules

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Electromotive actuators for combi valves

Room controller STRA-17

Product and functional description

VAV modular controller

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

VAV compact controller KNX / PL-Link

Extension module for lighting control

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Electromotoric actuators

Digital input modules

VAV compact controller GDB181.1E/3 GLB181.1E/3

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Product and functional description

7-day room temperature controller

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

Rotary version, three-position control

Zelio Control-modular measurement and control relays 1

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Switching and Monitoring Device

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

HERZ Actuator 7708, 7990

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

Compact universal controllers

Pre-programmed room controller with display and communication

Contact protection relay

Product and Function Description

Status display unit with P-bus connection

Transcription:

3 021 Room Temperature Controllers for two-pipe fan coil units RCC10 Output for on / off valve actuator Outputs for three-speed fan Control depending on the room or return air temperature (RCC10) Automatic heating / cooling changeover Operating modes of RCC10: normal, energy saving and frost protection mode or OFF Operating modes of RCC10.1: normal and energy saving mode or OFF Operating mode changeover input for remote control Function for avoiding damage resulting from moisture (RCC10.1) Selectable control parameters (RCC10) Operating voltage AC 230 V Use Typical use: Control of the room temperature in individual rooms that are heated or cooled with two-pipe fan coil units. For opening or closing a valve and for switching a three-speed fan. Suitable for use in systems with automatic heating / cooling changeover continuous heating or cooling operation. CE1N3021en 12.06.2003 Siemens Building Technologies Landis & Staefa Division

Functions The controller acquires the room temperature with its integrated sensor or external room temperature sensor (QAA32) or external return air temperature sensor (QAH11.1) if used (optional with the RCC10) and maintains the setpoint by delivering control commands to the 2-point-valve. The switching differential with the RCC10 is adjustable; it can be 1 or 4 K in heating mode and 0.5 or 2 K in cooling mode RCC10.1 is fixed; it is 2 K in heating mode and 1 K in cooling mode Fan operation The fan is switched to the selected speed via control output Q1, Q2 or Q3. When the function Temperature-dependent fan control is activated (can be selected with DIP switch no.1), the fan is switched on / off depending on the temperature, that is, together with the valve. It is switched off by leaving the heating or cooling sequence, provided the function Temperaturedependent fan control is activated, or manually changing to standby, provided plant conditions do not call for frost protection mode (only with the RCC10), or activating an external operating mode changeover switch, provided plant conditions do not call for energy saving or frost protection mode (only with the RCC10), or turning the controller s power supply off. Heating and cooling mode ON OFF The heating or cooling valve receives the OPEN command via control output Y11 when 1. the measured room temperature lies by half the switching differential below the setpoint (heating mode) or above the setpoint (cooling mode), and 2. the valve has been fully closed for more than one minute. The heating or cooling valve receives the CLOSE command via control output Y11 when 1. the measured room temperature lies by half the switching differential above the setpoint (heating mode) or below the setpoint (cooling mode), and 2. the valve has been fully open for more than one minute. Note: control output Y12 delivers a control command which is inverted to the control command at output Y11 and can be used for normally open valves Return air temperature The RCC10 provides control either depending on the measured room temperature or depending on the fan coil unit s return air temperature. Changeover is automatic if a QAH11.1 cable temperature sensor is connected. 2/8

Automatic changeover The water temperature acquired by the changeover sensor (QAH11.1 + ARG86.3) is used by the controller to switch from heating to cooling mode, or vice versa. When the water temperature lies above 28 C, the controller switches to heating mode, below 16 C it switches to cooling mode. If, immediately after switching on, the water temperature lies between the 2 changeover points, the controller will start in heating mode. The water temperature is measured at minute-intervals and the operational status updated. Heating mode Cooling mode Automatic changeover 1 0 Y11 W SDH 3021D01 T [ C] 1 0 Y11 W SDC 3021D02 T [ C] CM HM M 16 28 3021D03 T W [ C] CM Cooling mode T W Water temperature HM Heating mode w Room temperature setpoint M Operating mode Y11 Manipulated variable Valve SDC Switching differential Cooling T Room temperature SDH Switching differential Heating Purging function Energy saver The task of the changeover sensor is to initiate the change from heating to cooling mode even if the two-port valves are shut down for a longer period of time. To ensure this function, the valves are opened for one minute at 2-hour intervals during off hours. (Note: this function is not effective when using thermal actuators) The room temperature setpoint can be limited in increments of 1 K by making use of the minimum and maximum limitation facility. Arbitrary setpoint readjustments can thus be prevented. Operating modes Normal operation Frost protection mode (only with the RCC10) Energy saving mode The following operating modes are available: Heating or cooling mode with automatic changeover and with manually selected fan speed III, II or I. In normal operation, the controller maintains the adjusted setpoint. The frost protection function is activated only when DIP switch no.4 is set to OFF. Frost protection mode can be activated either by manually switching to standby. by activating the external operating mode changeover switch, provided DIP switch no.2 is set to OFF If the room temperature falls below 8 C, the controller will automatically switch to frost protection mode. In that case, the heating valve opens and the fan operates at the selected speed. If the operating mode selector is in position standby, the fan will operate at speed I. The room temperature is maintained at a setpoint of 8 C and the setpoint adjusted by the user will be ignored. If frost protection mode is locked (DIP switch no.4 in position ON), standby is locked also, which means that the controller will not switch to standby but to OFF: In energy saving mode, the setpoint of heating is 16 C and the setpoint of cooling 28 C, independent of the position of the setpoint knob. This operating mode will be activated when input D1 for operating mode changeover is active and DIP switch no.2 is set to ON. 3/8

Avoiding damage resulting from moisture (only with the RCC10.1) Operating mode changeover switch To avoid damage due to moisture in very warm or humid climatic zones resulting from lack of air circulation in energy saving mode, the fan will not be switched off when selecting the function Temperature-independent fan control (with DIP switch no.1) A changeover switch can be connected to status input D1-GND. When the switch closes its contact (caused by an open window, for instance), the operating mode will change from normal operation to energy saving mode (provided DIP switch no.2 is set to ON), or from normal operation to standby (provided DIP switch no.2 is set to OFF). If the room temperature falls below 8 C and if DIP switch no.3 is set to OFF, frost protection mode will become active. The operating action of the switch (N.C. or N.O.) can be selected. Type summary Type reference RCC10 RCC10.1 Features With input for return air temperature sensor Without input for return air temperature sensor, without frost protection function Ordering When ordering, please give name and type reference. The QAH11.1 temperature sensor (can be used as a return air temperature or changeover sensor), the changeover sensor mounting kit and the valves are to be ordered as separate items. Equipment combinations Type of unit Type reference Data sheet Temperature sensor QAH11.1 1840 Room sensor QAA32 1747 Changeover mounting kit ARG86.3 1840 Motoric on/off actuator SFA21... 4863 Thermal actuator (for radiator valve) STA21... 4893 Thermal actuator (for small valve 2,5 mm) STP21... 4878 Mechanical design The unit consists of two parts: A plastic housing which accommodates the electronics, the operating elements and the built-in room temperature sensor A mounting base The housing engages in the mounting base and snaps on. The base carries the screw terminals. The DIP switches are located at the rear of the housing. 4/8

Setting and operating elements 3021Z01 2 3 5 6 4 1 Legend 6 Set of DIP switches 1. Operating mode selector (standby, heating or cooling mode with manual selection of fan speed) 2 LEDs for indicating heating mode, cooling mode and fan operation 3 Setting facility for minimum setpoint limitation (in increments of 1 K) 4 Setting facility for maximum setpoint limitation (in increments of 1 K) 5 Room temperature setpoint knob DIP switch no. Meaning Position ON Position OFF 1 Fan control Fan control is temperaturedependent in all operating modes 2 Operating mode changeover via external switch 3 2) Operating action of switch for external operating mode changeover Changeover between normal operation and energy saving mode Changeover activated when contact of switch is closed (N.O.) 1) 4 2) Standby Frost protection function not enabled Fan control in normal operation (and in energy saving mode with the RCC10.1) is temperature independent 1) Changeover between normal operation and standby 1) Changeover activated when contact of switch is open (N.C.) Frost protection function enabled 1) 4 K in heating mode 5 2) Switching differential 1 K in heating mode 1) 0.5 K in cooling mode 1) 2 K in cooling mode 1) Factory setting 2) Only with the RCC10 The RCC10.1 comes with the following fixed settings: Switching differential in heating mode: 2 K Switching differential in cooling mode: 1 K Standby: OFF, no frost protection Operating action of switch for external operating mode changeover: N.O. Accessories Description Adapter plate 120 x 120 mm for 4 x 4 conduit boxes Adapter plate 96 x 120 mm for 2 x 4 conduit boxes Adapter plate for surface wiring 112x130 mm Type reference ARG70 ARG70.1 ARG70.2 5/8

Engineering notes In systems with automatic changeover, the temperature sensor can be replaced by an external switch for manual changeover. In systems with continuous heating operation, no sensor will be connected to the controller s input. With continuous cooling operation, the controller input (B2 M) must be bridged. Mounting, installation and commissioning notes Mounting location: on a wall or inside the fan coil unit. Not in niches or bookshelves, not behind curtains, above or near heat sources and not exposed to direct solar radiation. Mounting height is about 1.5 m above the floor. The connecting wires can be run to the controller from a recessed conduit box. Check the settings of the DIP switches no.1 through no.5 (with the RCC10) and of no.1 and no.2 (with the RCC10.1) and change them, if required. If setpoint limitation is required, use the minimum and maximum limitation facility (energy saver). After applying power, the controller makes a reset during which the fan LED flashes, indicating that the reset has been correctly made. This takes about 3 seconds. Then, the controller will be ready to operate. Prior to fitting the changeover sensor, thermal conductive paste must be applied to the location on the pipe where the sensor is placed The cables used must satisfy the insulation requirements with regard to mains potential Sensor inputs B1 M and B2 M carry mains potential. If the sensor s cables must be extended, the cables used must be suited for mains voltage The controller is supplied with Mounting Instructions. Technical data Power supply Operating voltage AC 230 V +10/-15 % Frequency 50/60 Hz Power consumption max. 6 VA Control outputs Q1, Q2, Q3 Rating Control output Y11 (N.O. contact) Rating Control output Y12 (N.C. contact) Rating Signal input B1 for return air sensor Signal input B2 for changeover-sensor AC 230 V max. 600 VA AC 230 V max. 300 VA AC 230 V max. 300 VA QAH11.1, Safety class II NTC resistor 3kΩ at 25 C QAH11.1, Safety class II NTC resistor 3kΩ at 25 C 6/8

Operational data Environmental conditions Norms and standards General Status input D1 and GND Contact sensing Insulation against mains Operating action With the RCC10 With the RCC10.1 Perm. cable length with copper cable 1.5 mm 2 for connection to terminals B1, B2 and D1 SELV DC 6-15V / 3-6 ma 4 kv, extra insulation selectable (N.O. / N.C.) (N.O.) 80 m Setpoint setting range 8...30 C Max. control deviation at 25 C max. ±0.7 K Switching differential in heating mode SDH 1 K or 4 K (selectable) Switching differential in cooling mode SDC 0.5 K or 2 K (selectable) Setpoint «Energy saving mode», heating 16 C Setpoint «Energy saving mode», cooling 28 C Setpoint «Standby» 8 C Operation Climatic conditions Temperature Humidity Transport Climatic conditions Temperature Humidity Mechanical conditions Storage Climatic conditions Temperature Humidity conformity to EMC directive Low voltage directive to IEC 721-3-3 class 3K5 0...+50 C <95 % r.h. to IEC 721-3-2 class 2K3 25...+70 C <95 % r.h. class 2M2 to IEC 721-3-1 class 1K3 25...+70 C <95 % r.h. 89/336/EEC 73/23/EEC and 93/68/EEC N474 C-Tick conformity to EMC emission standard AS/NSZ 4251.1:1994 Product standards Automatic electrical controls for household and similar use Electromagnetic compatibility Emissions Immunity EN 60 730 1 and EN 60 730 2-9 EN 50 081-1 EN 50 082-1 Safety class II to EN 60 730 Pollution class normal Degree of protection of housing IP 30 to EN 60 529 Connection terminals Use solid wires or prepared stranded wires. 2 x 0.4-1.5 mm 2 or 1 x 2.5 mm 2 Weight 0.25 kg Colour of housing front white, NCS S 0502-G (RAL9003) 7/8

Connection terminals Connection diagrams L B1* M B2 D1GND N Q1 Q2 Q3 Y12 Y11 N SELV 3021G01 L, N Operating voltage AC 230 V B1* Status input Return air temperature sensor M Measuring neutral Return air temperature sensor B2 Status input Changeover sensor D1, GND Status input for potential-free operating mode changeover switch (operating action can be selected) Q1 Control output Fan speed I AC 230 V Q2 Control output Fan speed II' AC 230 V Q3 Control output Fan speed III' AC 230 V Y11 Control output ' Valve AC 230 V (N.O. contact, for N.C. valves) Y12 Control output Valve ' AC 230 V (N.C. contact, for N.O. valves) * Only with the RCC10 L B1* B2 S1 L B1 M B2 D1 GND N Q1 Q2 Q3 Y12 Y11 N 3021A01 N1 B1* Return air temperature sensor (QAH11.1) B2 Changeover sensor (QAH11.1 temperature sensor + ARG86.3 changeover mounting kit) M1 Three-speed fan N1 RCC10 / RCC10.1 room temperature controller S1 External operating mode changeover switch Y1 MVE... / MXE... zone valve N I II III M1 Y1 * Only with the RCC10 N Dimensions Unit/baseplate 4 28 28 114,15 30 35 28 28 3021M01 4 104 96,6 42,8 11,8 4 26 30 90 3021M02 8/8 2000 Siemens Building Technologies AG