Digital Modules AS-i in IP20, 22,5 mm

Similar documents
Digital Modules AS-i, IP67, M12

AS-i Safety Output Module, IP20

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

Analog Modules AS-i, IP67, M12

Active Distributors AS-i Safety, Active Distributors AS-i

AS-i Safety Input Modules (M12), IP67

AS-i 3.0 Motor modules

AS-i 3.0 motor module

Active Distributors ASi Safety, IP67

AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Analog Modules AS-i IP65, M12

AS-i 3.0 motor modules

Encoder signal/ Sensor signal. Number of monitored axes. sine/cosine, SSI, TTL (1) up to 2 independent axes. sine/cosine. up to 2 independent axes

AS-i Safety Analog Input Module, IP20

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

PCB AS-i modules, board based solutions

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-Interface I/O Module

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 EtherCAT Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Installation Instructions Temperature transmitter TAA /00 06/2011

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017

Diagnostics (Logical) Diagnostics (Physical)

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

VersaMax IP I/O Module

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i Safety Relay Output Module with Diagnostic Slave

ILB DN 24 DI16 DO16. Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs. AUTOMATIONWORX Data Sheet 6885_en_05

System manual AS-i safety monitor AC041S /00 05/2013

Device manual AS-i PowerSwitch ZB0028 ZB0040

Operating instructions. ProcessLine analogue module AC / / 2012

VersaPoint I/O Module

Protected VARAN Digital Mixed Module PVDM 086

Data Sheet 1SD210F2-5SNA1200G Single-Channel SCALE Plug-and-Play IGBT Driver

Operating instructions valve control box AS-i

SENSICK AS-i Components. Technical Description

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

CPX-Terminal. Brief description. CPX analogue I/O modules CPX-4AE CPX-2AA. English e [ ]

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

Solid State Remote Power Controller E /627

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

RSTI-EP Slice I/O. Digital Output Module

GS202 Encoder Switch

Operating instructions AC010S Compact AS-i E-STOP safety module

VersaMax IP Input Module

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ]

Faults on the system Proximity switch connection technology:

02/11/2015

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Digital electropneumatic positioner

Expansion Module HZS 541-1S

Zelio Control-modular measurement and control relays 1

BMXMSP0200 PTO module - 2 channels - 4 input - 24 V DC ma - 2 connectors 28 pins

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Data Sheet 1SD210F2-5SNA0750G Single-Channel SCALE Plug-and-Play IGBT Driver

XPSMCMDO Digital output pairs expansion modules with screw term

SX5A AS-Interface(Communication Terminal and Repeater)

Cube20. Application-oriented. Installation-friendly. Efficient

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Diagnostics (Logical) Diagnostics (Physical)

Operating instructions Programming and display unit PP / / 2010

Communication & Networking

Solid State Remote Power Controller E

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

General Data. Ambient Conditions - Operating temperature: -25 C C - Storage temperature: -40 C C - Humidity: up to 95%, non-condensing

Diagnostics (Logical)

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

Compact Coded Magnetic Safety Interlock Switch and Control Units

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

Non-communicating room controllers

AS-Interface INSTALLATION GUIDE, TIPS AND TRICKS

LVX Control Unit. Features:

XPSMCMMX inputs 2 output pairs expansion module with screw term

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

EARTH-FAULT AND SHORT-CIRCUIT INDICATOR TYPE EKL8001 / EKL8002 surface mounted

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

I/O Modules Active Stand-Alone: Interbus

Transcription:

Digital Modules AS-i in 22,5 mm Cost efficient solution in IP20 (Figure similar) Figure Type Housing s digital digital voltage (sensor supply) (1) Output voltage (actuator supply) (2) AS-i connection (3) AS-i address (4) Article No. 22,5 mm x 50 mm, COMBICON 4 out of AS-i out of AS-i clamps 1 AB slave 22,5 mm x 114mm, 6 x COMBICON 22,5 mm x 114mm, 6 x COMBICON 3x COMBICON 4 out of AUX clamps 1 AB slave BWU2723 COMBICON 4 COMBICON 4 COMBICON out of AUX out of AUX clamps 1 AB slave BWU1938 out of AUX out of AUX clamps 1 single slave BWU 2759 8 out of AUX clamps 2 AB slaves BWU2721 6x COMBICON 8 8x 6x COMBICON 8 8x out of AUX out of AUX clamps 2 AB slaves BWU2490 out of AUX out of AUX clamps 2 single slaves BWU2800 (1) voltage (sensor supply): inputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, inputs shall not be connected to earth or to external potential. (2) Output voltage (actuator supply): outputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, outputs shall not be connected to earth or to external potential (3) : the connection to AS-i as well to AUX (auxiliary 24 V power) is made via yellow resp. black AS-i profile cable with piercing technology or via M12 socket (in IP20 via clamps). (4) AS-i address: 1 AB Slave (max. 62 AB Slaves/AS-i network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/AS-i network), mixed use allowed. For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0". Upon request, slaves are available with specific AS-i Slave profiles. www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 6.8.15 page 1

Digital Modules AS-i in 22,5 mm I/O: unlimited (1) Article no. BWU1938 BWU2759 BWU2723 BWU2721 BWU2490 BWU2800 General data Device type input / output input input / output Connection AS-i / AUX connection COMBICON plug Periphery connection COMBICON plug Length of connector cable I/O: max. 15 m (1) AS-i Profile S-7.A.7, ID1=7 (fixed) S-7.0.E, ID1=F S-7.A.E, ID1=7 Slave 1: S-7.A.E, ID1=7 Slave 2: S-7.A.E, ID1=6 Slave 1: S-7.A.7, ID1=7 (fixed), Slave 2: S-7.A.7, ID1=6 Slave 1: S-7.0.E, ID1=F Slave 2: S-7.0.E, ID1=E AS-i address 1 AB slave 1 single slave 1 AB slave 2 AB slaves 2 single slaves Required Master profile M4 M0 M3 M4 M0 Since AS-i specification 3.0 2.0 2.1 3.0 2.0 Operating voltage 30 V (18 31.6 V) Max. current consumption 165 ma 35 ma 60 ma Max. current consumption 45 ma 35 ma 60 ma without sensor/ actuator supply AUX Voltage 24 V (18 30 V) Max. current consumption 4 A 1,2 A 8 A Number 4 8 Power supply out of AS-i out of AUX Power supply of attached sensors 120 ma max. 1,2 A permanent operation (4) ( in- and outputs) max. 120 ma (2) Switching threshold U<5 V (low) U>15 V (high) Output Number 4 x 4 x 8 x, short circuit protected Power supply out of AS-i out of AUX out of AUX Max. output current 120 ma ( in- and outputs) max. 120 ma (2) 1A ( 3A max.) (5) 1 A ( 3A max. O1-O4, 3A max. O5-O8) (5) page 2 Mannheim, 6.8.15 We reserve the right to change any data www.bihl-wiedemann.de

Digital Modules AS-i in 22,5 mm Article no. BWU1938 BWU2759 BWU2723 BWU2721 BWU2490 BWU2800 Display LED ASI (green) on: AS-i voltage on, flashing: AS-i voltage on, but peripheral fault (3) or address 0 off: no AS-i voltage LED FLT/FAULT (red) on: slave address 0 or slave offline flashing: peripheral fault (3) off: slave online LED ASI/FLT 1 (red/green) green: slave online red: slave offline yellow/red flashing: address 0 red/green flashing: peripheral fault (3) LED ASI/FLT 2 (red/green) green: slave online red: slave offline yellow/red flashing: address 0 red/green flashing: peripheral fault (3) red flashing: slave 2 is switched off, because slave 1 is offline LEDs I1... In (yellow) state of inputs I1... I4 state of inputs I1... I8 LEDs O1... On (yellow) state of outputs O1-O4 state of outputs O1-O8 LED AUX (green) on: 24 V DC AUX off: no 24 V DC AUX Environment Applied standards EN 61000-6-2 EN 61000-6-3 EN 60529 Operating altitude max. 2000 m Ambient temperature -25 C... -25 C +70 C +55 C Storage temperature -25 C +85 C Housing plastic, din-rail mounting Protection category IP20 Voltage of insulation 500 V Weight 65 g 120 g Dimensions (W / H / D) in mm 22,4 / 99,6 / 50,5 22,5 / 99 / 114 (1) Loop resistance: 150 Ω. (2) Derating current ma 120 60 20 40 50 55 C operating temperature (3) see table Peripheral fault indication www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 6.8.15 page 3

Digital Modules AS-i in 22,5 mm (4) Derating BWU1938, BWU2490, BWU2721, BWU2723, BWU2759, BWU2800 current A 1.2 0.6 40 70 C operating temperature (5) at operating temperature >60 C: Σ 1A max. Article no. Peripheral fault indication Overload sensor supply AUX voltage missing BWU1938 BWU2490 BWU2721 BWU2723 BWU2759 BWU2800 connections BWU1938 / BWU2759 I+, I- Sensor supply O- 1, O- 2 GND for outputs I1... I4 s O1... O4 I I + O 2 O 1 I 4 I 3 I 2 I 1 I 2 I 3 I 1 I 4 O 2 O 3 O 1 O 4 FAULT ASI I+, I- Sensor supply O- 1, O- 2 GND for outputs I1... I4 s O1... O4 ADDR O 1 O 2 O 3 O 4 ASI+ ASI NC NC + ASI page 4 Mannheim, 6.8.15 We reserve the right to change any data www.bihl-wiedemann.de

Digital Modules AS-i in 22,5 mm connections BWU2490 / BWU2800 I+, I- Sensor supply O- 1, O- 2 GND for outputs I1... I8 s O1... O8 BWU2723 I+ 1, I- 1, I+ 2,I- 2 Sensor supply I1... I4 BWU2721 I+ 1, I- 1, I+ 2,I- 2 Sensor supply I1... I8 module BWU1938 / BWU2490 / BWU2721 / BWU2723 / BWU2759 / / BWU2800... Output module BWU1938 / BWU2490 / BWU2759 / / BWU2800... I+ I1 I2... Ix O- O1 O2... Ox Separate power supply 24 V (s)... 0 V 24 V () I+ I1 I2... Ix AUX+ AUX- www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 6.8.15 page 5

Digital Modules AS-i in 22,5 mm Programming Bit setting D0 D1 D2 D3 BWU1938 / BWU2723 / BWU2759 / I1 I2 I3 I4 BWU2490 / BWU2721 / BWU2800 Slave 1: I1 Slave 1: I2 Slave 1: I3 Slave 1: I4 Slave 2: I5 Slave 2: I6 Slave 2: I7 Slave 2: I8 Output BWU1938 / BWU2759 / O1 O2 O3 O4 BWU2490 / BWU2800 Slave 1: O1 Slave 1: O2 Slave 1: O3 Slave 1: O4 Slave 2: O5 Slave 2: O6 Slave 2: O7 Slave 2: O8 Parameter bit P0 P1 P2 P3 BWU2490 / BWU2800 BWU2723 / BWU2721 BWU1938 / BWU2759 not used, watchdog always on 0 = off / 1 = on (peripheral fault, if AUX voltage missing) 0 = off / 1 = on (watchdog) 0 = on / 1 = off (data input filter 128 μs) not used 0 = on / 1 = off (synchronous I/O mode) not used page 6 Mannheim, 6.8.15 We reserve the right to change any data www.bihl-wiedemann.de