Welkom bij het Webinar Industrial Automation

Similar documents
TIA Portal V15. The digital revolution

WinAC RTX 2010 Getting Started. Getting-started. Edition ( )

SIMATIC. S7-1500, ET 200SP, ET 200pro Structure and Use of the CPU Memory. Preface. Documentation guide. Memory areas and retentive memory

Bienvenue au webinaire SPS IPC Drives Pour le bon déroulement de ce webinaire, merci de couper votre micro. Ce webinaire sera enregistré.

Siemens Safety Integrated Take a safe step into the future

1 What's new in SIMATIC imap STEP 7 AddOn?

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

Multi Panel options. SIMATIC WinAC MP 2/169

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

Why can you not transfer the HMI configuration to the panel? - PROFIBUS Connection - FAQ 03/2014

PLC COURSE LIST NMU TRAINING CENTRE

SIMATIC. PCS 7 Process Control System CFC Readme V9.0 SP2 Upd2 (Online) Security information 1. Overview 2. Notes on Installation 3.

SCE Training Curriculum For Integrated Automation Solutions Totally Integrated Automation (TIA)

Sample project Filling Station SIMATIC. STEP 7 Professional / WinCC Advanced V11 for Sample project Filling Station. Overview of the Getting.

SCE Training Curriculum for the end-to-end automation solution Totally Integrated Automation (TIA)

ID Title Description of the restriction Solutions for the restriction

SIMATIC S7-PLCSIM Advanced V1.0. Simulation with TIA Portal V14 and PLCSIM Advanced

SIEMENS CERN EN/ICE annual meeting

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

General information. Configuration control. Display. Control elements. Supply voltage

SIMATIC. TIA-Portal SIMATIC Visualization Architect. Security information 1. Basics 2. Installation 3. Elements and basic settings 4

TIA Portal V11 Exercises

1 What's new in SIMATIC imap STEP 7 AddOn?

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

WinCC RT Professional V15 architectures V1.0

WinCC Professional V15 architectures

How can you display error messages and warnings of a frequency converter on a panel? WinCC flexible RT and Panels FAQ

SCE Training Curriculum for the end-to-end automation solution Totally Integrated Automation (TIA)

I-Device Function in Standard PN Communication SIMATIC S7-CPU, CP, SIMOTION, SINUMERIK. Configuration Example 08/2015

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

General information. Configuration control. Display. Control elements. Supply voltage

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

SIMATIC. PCS 7 Licenses and configuration limits (V9.0) Security information 1. Preface 2. Selecting the correct license keys 3

Engineered with TIA Portal. Increase productivity with the ultimate power. Advanced Controllers SIMATIC S with ET 200MP. siemens.

Applications & Tools. Communication between WinAC MP and a SIMATIC S7. Application for the PUT and GET Function Blocks of the S7 Communication

SIMATIC S Central processing units

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

STEP 7 PROFESSIONAL. Function STEP 7

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

SITRAIN. Introduction TIA Portal. Siemens AG All rights reserved. Unrestricted

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

Service & Support. Data Communication between S7 Station and PC Station, using SIMATIC NET OPC Server SIMATIC S7. Function description March 2013

S7-400 CPU ES XJ05-0AB0 V5.2 Work memory 144KB code and 144KB of data; ms/1000 instructions; 4KB DI/O; 32 connections 1*DP/MPI;


Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

Advanced Process Functions V2.0

Totally Integrated Automation (T I A) MODULE A1 Totally Integrated Automation (T I A)

General information. Display. Control elements. Supply voltage

PC-based Control Open, flexible and reliable. Product Brief February 2004

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

Service & Support. MODBUS/TCP Communication over Integrated PROFINET Interface of S7-300 and S7-400 CPU. Modbus/TCP PN CPU.

Applications & Tools. Programming Guideline for S7-1200/S STEP 7 (TIA Portal) Background and system description October 2013

PROFINET at the SPS/ IPC/DRIVES exhibition

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

Display of SINAMICS Fault Messages in WinCC V7.4

Sitrain. Training which combines theory and practice. Complete training catalogue. Innovation for generations.

Communication between HMI and Frequency Converter. Basic Panel, Comfort Panel, Runtime Advanced, SINAMICS G120. Application Example 04/2016

SCE Training Curriculum

The library for plastics machines. Building a complete machine with modular software and hardware.

Simple - smaller - stronger SIMATIC ET 200SP. Unrestricted / Siemens AG All Rights Reserved.

General information. Display. Control elements. Supply voltage

SIMATIC S plus TIA Portal

View the most recent product information online

SIMATIC HMI Panels. Technical Data. siemens.com/hmi. Answers for industry. Engineered with TIA Portal

SPEED7 Studio - the engineering software from VIPA that allows a more economic and effi cient use of all new VIPA controllers

Engineered with TIA Portal. Increase productivity with the ultimate power. Advanced Controllers SIMATIC S with ET 200MP. siemens.

Product type designation

SIMATIC. Process Control System PCS 7 V7.0 SP1 Software Update With Utilization of New Functions (PCS 7 V6.x to V7.0 SP1) Preface.

General information. Supply voltage. Input current

IE/PB LINK PN IO. PROFINET applications

Configuration Control with the S and ET 200SP

Block Library Motor Starter SIRIUS for SIMATIC PCS 7

General information. Display. Control elements. Supply voltage

SIMATIC Visualization Architect (SiVArc) Getting Started

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 7 2. Improvements in Update 6 3. Improvements in Update 5 4

General information. Supply voltage. Input current

Expertise in Industrial Networks. Ian Poulett Head of Sales Siemens



SINUMERIK Integrate Create MyHMI / WinCC V13 SP1 SINUMERIK. SINUMERIK 840D sl SINUMERIK Integrate Create MyHMI / WinCC V13 SP1. Preface.

Panels 270 series SIMATIC TP 277 6" 2/131. Overview

TIA Portal Workshop. Unrestricted. Siemens AG All rights reserved.

SINAMICS Drives Connectivity with EtherNet/IP TM. Networks. Manufacturing in America 02/22-23/2017

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

internet in google, bing, yahoo and other mayor seach engine. This special edition completed with other document such as :

SIMATIC. Process Control System PCS 7 Product Brief on Software Updates from V5.1/V5.2 to PCS 7 V7.0 SP1. Preface 1

The SIMATIC ET 200SP Open Controller: The compact PC-based controller from the S series siemens.com/open-controller

SIMIT Simulation. Optimize your plant, increase your competitiveness

SITRAIN Training for Industry. Customer Services Information 2019


Configuration Control with the S and ET 200SP

SIMATIC. PCS 7 process control system PCS 7 SMART (V9.0) Security information 1. Preface 2. System Requirements 3. Licenses 4

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

SCE Training Curriculum

TIA Portal V15. TIA Portal V15 news. Rostislav Kosek

Siemens Automation Parts

STEP 7. Function. Page 1791 Mar 2008 Siemens ITS

Connecting a PC Station to an S using OPC

Transcription:

Welkom bij het Webinar Industrial Automation We starten om 0u00. Voor een vlot verloop van dit webinar, gelieve uw microfoon uit te schakelen. Dit webinar wordt opgenomen

Agenda. Hoever staan we met de TIA portal? 2. Welke PLC's zijn beschikbaar? 3. Hoe ziet de toekomst eruit? 4. Migratiethema's, Page 2

Agenda. Hoever staan we met de TIA portal? 2. Welke PLC's zijn beschikbaar? 3. Hoe ziet de toekomst eruit? 4. Migratiethema's, Page 3

Totally Integrated Automation Portal One Engineering Framework for all Automation Challenges Totally Integrated Automation Portal STEP 7 V5 Safety V5 WinCC V5 Startdrive V5 SIMATIC PLC Safety SIMATIC HMI SINAMICS V5, 22/2/207 One common Engineering Framework for the Production-Automation Page 4

Basic licenses Overview of the software performance range SIMATIC STEP 7 V4/ STEP 7 Safety V4 SIMATIC WinCC V4 Programming languages (F-)KOP, (F-)FUP, SCL, AWL ), S7-GRAPH ) Machine-level operator control and monitoring and process visualization (SCADA) S7-500/ SW-Controller (F) SCADA S7-300/400/WinAC (F) Single station PC S7-500 (F) S7-200 (F) Basic Basic Professional Advanced Basic Comfort Advanced Professional Comfort Panels and Mobile (without Micro) Basic Panels and 2 nd Generation Communication Common functions Engineering options PROFIBUS, PROFINET, AS-i, IO-Link, ET 200, network topology PROFIsafe via PROFIBUS and PROFINET E.g. System diagnostics, import/export to Excel, Undo, E.g. TIA Portal Multiuser, SIMATIC Energy Suite, SIMATIC ProDiag ) S7-300/400/500/WinAC Page 5

System functions Win0-Support for TIA Portal Use case Supported operating systems Windows 7 (64-bit) Windows 7 End of ext. support: 0/2020 Windows 7 Home Premium SP * Windows 7 Professional SP Windows 0 Customer benefits V3 SP2 V4 SP V5 0/2025 Windows 7 Enterprise SP Windows 7 Ultimate SP Windows 0 (64-bit) Windows 0 Home Version 703 * Windows 0 Professional Version 703 * Windows 0 Enterprise Version 703 Windows 0 Enterprise 206 LTSB Long-term Microsoft Windows support with Windows 0 One shared operating system platform for TIA Portal and "Classic* products" Project upgrade to a single-station computer : Vxx V3 SP2 V4 SP /V5 Windows 0 IoT Enterprise 205 LTSB Windows 0 IoT Enterprise 206 LTSB Windows Server (64-bit) Windows Server 202 R2 StdE (full installation) Windows Server 206 Standard (full Installation) *for Basic edition only Page 6

TIA Portal Products and actual products compatibility Installation of different software products on a single computer WinCC flexible 2008 SP2 onwards STEP 7 V5.4 SP5 onwards TIA Portal based software: V, V2, V3, V4, V5... Page 7

Available Devices in TIA Portal Overview All modules that are still actively marketed as of 0.0.2007 Controller Modular Controller SIMATIC S7 S7-500 S7-200 S7-300 S7-400 SIMATIC PC-based Controller SIMATIC S7-modular EC (F) SIMATIC WinAC RTX (F) SIMATIC WinAC MP Page 8 Distributed I/O ET 200S ET 200M ET 200L ET 200iSP ET 200pro ET 200eco PN ET 200eco ET 200R ET 200SP ET 200MP Industrial Communication PROFIBUS PROFINET Gateways AS-Interface SIMATIC HMI Panel SCADA SINAMICS Drives G20 Others via GSD(ML)

Vraag : Heeft U reeds ervaring met TIA-portal?

Agenda. Hoever staan we met de TIA portal? 2. Welke PLC's zijn beschikbaar? 3. Hoe ziet de toekomst eruit? 4. Migratiethema's, Page 0

SIMATIC S7-500 Positioning modular controller Segment Product Application Characterization Advanced Basic Standard Nano SIMATIC S7-400 SIMATIC S7-300 SIMATIC S7-200 LOGO! The modular controller for system solutions in the middle to high-end range automation * ) The modular compact controller for solutions in the compact / basic area of automation Logic modules for switching and monitoring for low-end applications automation (modular) controller (modular) compact controller logic modules TIA applications Stand alone applications Applications complexity Capability I/O capacity, program size, instruction time, communication skills, Page

SIMATIC New Controller Generation Controller scalability that meets all requirements Performance S7-200: Basic Control Perfect for stand-alone simple machine control Material handling & packaging Vertical form, fill and seal S7-500: Advanced Control Balance of control for machines or plants Complex automation architectures that require Many HMI s, Drives and other field devices Customized mass production control Perfect for when machine to machine controls are required for an entire production process Application Requirements Page 2

SIMATIC New Controller Generation Always the appropriate Controller performance with comprehensive functionalities! Engineered with TIA Portal System performance Advanced Controller SIMATIC S7-500 Software Controller SIMATIC S7-500 Distributed Controller SIMATIC ET 200SP CPU Basic Controller SIMATIC S7-200 Application complexity Page 3

Discover New Dimensions Imagine the perfect CPU Page 4

SIMATIC Basic Controller portfolio SIMATIC S7-200 CPU CPU type 2C 22C 22FC 24C 24FC 25C 25FC 27C PROFINET Ports Work memory / int. load memory 50 kb MB 75kB 2 MB 00kB 2 MB 00kB 4 MB 25kB 4 MB 25 kb 4 MB 50 kb 4 MB 50 kb 4 MB Bit performance 85 ns 85 ns 85 ns 85 ns 85 ns 85 ns 85 ns 85 ns Connection resources 38 38 38 38 38 38 38 38 Integrated Digital I/O 6/4 8/6 8/6 4/0 4/0 4/0 4/0 4/0 Integrated Analog I/O 2/- 2/- 2/- 2/- 2/- 2/2 2/2 2/2 High-Speed Counter 6 6 6 6 6 6 6 6 Page 5

Hardware Configuration Overview of SIMATIC S7-500 The right CPU for every application Compact CPUs Standard-CPUs Technology CPUs MFP CPU types 5C- PN 52C- PN 5F- PN 53F- PN 55F-2 PN 56F-3 PN/DP 57F-3 PN/DP 58F-4 PN/DP 5TF- PN 55TF-2 PN 56TF-3 PN/DP 57TF-3 PN/DP 58F-4 PN/DP MFP Interfaces 2 2 2 2 3 2 2 2 2 3 Program/ data storage 75 KB MB 250 KB MB 50/ 225 KB MB 300/ 450 KB.5 MB 500/ 750 KB 3 MB /.5 MB 5 MB 2/3 MB 8 MB 4/6 MB 20 MB 225/ 225 KB MB 750/ 750 KB 3 MB.5/.5 MB 5 MB 3/3 MB 8 MB 4/6 MB 20 MB 50 MB Bitperformance Max. number of connections 60 ns 48 ns 60 ns 40 ns 30 ns 0 ns 2 ns ns 60 ns 30 ns 0 ns 2 ns ns 96 28 96 28 92 256 320 384 96 92 256 320 384 Positioning axes Typical 2 Maximum 2 5 0 5 0 5 0 5 0 7 30 7 30 70 28 28 28 5 0 7 30 65 80 70 28 28 28 Width 85 mm 0 mm 35 mm 35 mm 70 mm 70 mm 75 mm 75 mm 35 mm 70 mm 75 mm 75 mm 75 mm Additional 50 MB memory for ODK applications; 2 For 4ms Servo/IPO cycle Page 6 New New

SIMATIC Distributed Controller portfolio PROFIBUS PROFINET / IE S7-50SP S7-50SP F S7-52SP S7-52SP F CM DP CPU type 50SP -PN 50SP F-PN* 52SP -PN 52SP F-PN* DP-Master / DP-Slave Interfaces Program / Data memory 00 KB 750 KB 50 KB 750 KB 200 KB MB 300 KB MB 25 DP Slaves Bit instruction time 72 ns 72 ns 48 ns 48 ns Width 00 mm 00 mm 00 mm 00 mm 35 mm ET 200SP CPUs for low and middle range application Page 7

Vraag 2 : Heeft U reeds ervaring met de nieuwe generatie van PLC s? (S7-200 of S7-500)

Agenda. Hoever staan we met de TIA portal? 2. Welke PLC's zijn beschikbaar? 3. Hoe ziet de toekomst eruit? 4. Migratiethema's, Page 9

TIA Portal V5 There is even more Integrated Engineering Installation: Package, Classic Multiuser: Automatic selection, working locally and server improvements Shared commissioning: Download/upload of tag tables PLCSIM: Simulation of blocks with knowhow protection for S7-500 Recipes with S7-500 in ASCII format Security: Configuration of Scalance M/S, UMAC integration Digital Workflow Openness: SCL export, PLC download, Startdrive supported PLCSIM Advanced: Interrupts, events, process image partitions, FW.8 to 2.5 SiVArc: Interrupt generation, template screens, trend view control Transparent Operation ProDiag: Improvements and quantity limit increase OPC UA: Client, methods, companion specifications Energy Suite: new instruction energy efficiency of maschines, change of powertag count within WinCC RT Prof. User Management Component: Plant-wide user management Page 20

SIMATIC S7-500 Positioning modular controller Segment Product Application Characterization Advanced Basic Standard Nano SIMATIC S7-400 SIMATIC S7-300 SIMATIC S7-200 LOGO! Phase-out st of october 203 The modular controller for system solutions in the middle to high-end range automation * ) The modular compact controller for solutions in the compact / basic area of automation Logic modules for switching and monitoring for low-end applications automation (modular) controller (modular) compact controller logic modules TIA applications Stand alone applications Applications complexity Capability I/O capacity, program size, instruction time, communication skills, Page 2

SIMATIC S7-500 Positioning modular controller Segment Product Application Characterization Advanced Basic Standard Nano SIMATIC S7-400 SIMATIC S7-300 SIMATIC S7-200 LOGO! Phase-out planned as from:st of october 2023 The modular controller for system solutions in the middle to high-end range automation * ) The modular compact controller for solutions in the compact / basic area of automation Logic modules for switching and monitoring for low-end applications automation (modular) controller (modular) compact controller logic modules TIA applications Stand alone applications Applications complexity Capability I/O capacity, program size, instruction time, communication skills, Page 22

Phase Out ET 200S Migration-strategy ET 200S ET 200SP Phase-out planned:st of october 209 Page 23

SIMATIC S7-500 Positioning modular controller Segment Product Application Characterization Advanced Basic Standard Nano SIMATIC S7-400 SIMATIC S7-300 SIMATIC S7-200 LOGO! The modular controller for system solutions in the middle to high-end range automation * ) The modular compact controller for solutions in the compact / basic area of automation Logic modules for switching and monitoring for low-end applications automation (modular) controller (modular) compact controller logic modules TIA applications Stand alone applications Applications complexity Capability I/O capacity, program size, instruction time, communication skills, Page 24

Vraag 3 : Is de strategie voor de PLC s duidelijk geworden voor U?

Agenda. Hoever staan we met de TIA portal? 2. Welke PLC's zijn beschikbaar en op welke manier een keuze maken? 3. Hoe ziet de toekomst eruit? 4. Migratiethema's, Page 26

Which kinds of migration exist? Existing solution Migration engineering Partial modernization Exchange of devices based on: End of product lifecycles Increase in productivity with new devices Advantage: investment protection, minimal effort Disadvantage: if so, two systems System extension Extension of an existing plant Advantage: investment protection Disadvantage: two systems Complete conversion Exchange of hardware, migration of software Advantage : innovative products, advantages of the new system will be completely used Disadvantage: considerable effort Page 27

SIMATIC S7-200 Positioning modular controller Segment Product Application Characterization Advanced Basic Standard Nano SIMATIC S7-400 SIMATIC S7-300 SIMATIC S7-200 LOGO! Phase-out st of october 203 The modular controller for system solutions in the middle to high-end range automation * ) The modular compact controller for solutions in the compact / basic area of automation Logic modules for switching and monitoring for low-end applications automation (modular) controller (modular) compact controller logic modules TIA applications Stand alone applications Applications complexity Capability I/O capacity, program size, instruction time, communication skills, Page 28

Siemens Controller Family Release Overview CPU22 CPU222 CPU224 CPU224XP CPU226 Page 29 Every CPU had two variants: 24V or 20-240V AC. 224XPsi: with current sinking outputs

Design and handling S7-200 Set-up and extension options - maximum S7-22 Ł S7-2 S7-222 Ł S7-22 S7-224 Ł S7-24 S7-224 XP Ł S7-24 S7-226 Ł S7-25 Page 30

SIMATIC S7-500 Positioning modular controller Segment Product Application Characterization Advanced Basic Standard Nano SIMATIC S7-400 SIMATIC S7-300 SIMATIC S7-200 LOGO! Phase-out planned as from:st of october 2023 The modular controller for system solutions in the middle to high-end range automation * ) The modular compact controller for solutions in the compact / basic area of automation Logic modules for switching and monitoring for low-end applications automation (modular) controller (modular) compact controller logic modules TIA applications Stand alone applications Applications complexity Capability I/O capacity, program size, instruction time, communication skills, Page 3

TIA-selection Tool Migration-strategy Need some help with the migration? Page 32

SIMATIC Innovation Migration to SIMATIC S7-500 CPU 55(F)-2 PN S7-300 S7-400 S7-500 CPU Type 35-2 PN/DP 35F-2 PN/DP 42-42-2 42-2PN 55-2PN 55F-2 PN Interfaces 2 2 2 Program / Data memory 384 KB 52 KB 256 KB 256 KB 52 KB 52 KB 52 KB 52 KB 500 KB 3 MB 750 KB 3 MB Bit-Performance 50 ns 50 ns 75 ns 75 ns 3.25 ns 30 ns 30 ns 3 Retain memory: Flags Counters Timers DB 2Kb 256 256 28Kb 2Kb 256 256 28Kb 4Kb 2048 2048 64Kb 4Kb 2048 2048 64Kb 4Kb 2048 2048 64Kb 52Kb 52Kb Page 33 PROFIBUS/MPI MPI IF Module PROFINET / IE PROFIBUS

CPU-Migration Page 34

SIMATIC Innovation Migration to SIMATIC S7-500 CPU 5(F)- PN S7-300?? S7-500 CPU Type 35-2 PN/DP 35F-2 PN/DP 5- PN 5F- PN Interfaces Program / Data memory 384 KB 52 KB 50 KB MB 225 KB MB Bit-Performance 50 ns 50 ns 60 ns 60 ns Retain memory: Flags Counters Timers DB 2Kb 256 256 28Kb 2Kb 256 256 28Kb 28 Kb 28 Kb Page 35 PROFIBUS/MPI MPI IF Module PROFINET / IE PROFIBUS

Overview STEP 7 V5.x STEP 7 V/2ŁV3 SP STEP 7 V4 S7-300 S7-400 Migrate Project S7-300 S7-400 Migrate to S7-500 S7-500 S7-300 S7-400 Upgrade S7-300 S7-400 Migrate to S7-500 S7-500 Page 36

Overview STEP 7 V5.x STEP 7 V/2ŁV3 SP STEP 7 V4 S7-300 S7-400 Migrate Project S7-300 S7-400 S7-300 S7-400 Upgrade S7-300 S7-400 Page 37

Migration steps Migration of engineering data (Availability of hardware testable by Readiness Check Tool) 2 Check the migration log and change the project if necessary 3 Compile the migrated project and resolve detected errors/warnings Page 38

Hardwareconfiguration With modules can be migrated All modules of the STEP 7 V5.5 project must be in the TIA-portal hardware catalog Important: Most of the modules which are actively marketed at the 0.0.2007 are included in the hardware catalog (readiness check tool) No longer actively marketed at the deadline Page 39

Step : Migration of the engineering data Start migration ŁProject Migrate,.. Portal view Project view Project to be migrated Migrate dialog Source: STEP 7 V5.5 project Target: Path for TIA-portal project Filetype *.S7P *.HMI *.am2 STEP 7 V5.x project WinCC flexible project Migrationfile Destination Progress Page 40

Start migration with/without hardware Default without hardware Page 4

Step 2: Check of the migration log Display of migration messages in the inspector area Direct link to respective editor Display of migration log Dialog at the end of the migration Folder Logs in project navigation Properties of the project Page 42

Step 3: Compile of the migrated project After a successful migration the user has to adjust the project if neccessary. Only a consistent program can be downloaded. Possible errors: Most common error, The STEP 7 V5.5 project needs to be consistent for the migration. If there are errors the migration will be aborted with an error message. Page 43

Achive block consistency Solution: Check the block consistency before you start the migration. Compile the program afterwards 2 2 Compile Check the block consistency Page 44

Precondition of the migration Error free project, Before migrating, TIP: Create a copy of you program with Save as with reorganization (slow)! Page 45

Overview STEP 7 V5.x STEP 7 V/2ŁV3 SP STEP 7 V4 S7-300 S7-400 Migrate to S7-500 S7-500 S7-300 S7-400 Migrate to S7-500 S7-500 Page 46

Migration steps Migration to S7-500 (right-click on the S7-300 or S7-400 CPU) S7-300 S7-400 2 Check the migration log and change the project if necessary 3 Compile the migrated project and resolve detected errors/warnings S7-500 Page 47

Step Start migrate PLC S7-500 S7-200 S7-300/400/WinAC 2 Open project with S7-300/400 and compile the project Start migrate to S7-500 Only the PLC will be migrated! Central modules and peripheral stations will not be changed and have to be reconfigured / reconnected by the user 2 Page 48

Step Choose S7-500 S7-500 S7-200 S7-300/400/WinAC 3 Choose new S7-500 plc for example CPU 56-3 PN/DP 3 Page 49

Step Security Advice S7-500 S7-200 S7-300/400/WinAC Before the migration will be started the user must confirm a security advice Program could be modified during the migration Manual corrections might still be necessary Test the program under security conditions Page 50

Step 2 Check the migration log Entrys in the log file Page 5

Step 3 After migration S7-500 S7-200 S7-300/400/WinAC After the migration the new PLC exists beside the old PLC Alle new PLCs have to be compiled Page 52

Vraag 4 : Heeft U reeds migraties gedaan van S7-300/400 naar S7-500?

Thank you