Perfect protection smallest space

Similar documents
Perfect protection smallest space

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

SIPROTEC 7SC805. Merging Unit for conventional instrument transformer. Products for digital substations.

Siprotec 7ST61 / 7ST63

Products for digital substations SIPROTEC 6MU805. Merging Unit for conventional instrument transformer. Integrated PRP, HSR. siemens.

Answers for energy. SIPROTEC 5 the new benchmark for protection, automation, and monitoring of transmission grids

Product Families and Positioning. Protection Portfolio

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note. Breaker-and-a-half solutions. SIP5-APN-002, Edition 2.

SIPROTEC 5 Application Note

Protective Relays & SCADA Systems

SIPROTEC 5 Application Note

Catalog Edition 6 siemens.com/protection

SIPROTEC 5 Application Note

Protection relays.

Substation Automation Products. Line differential protection RED670 Relion 670 series

SIPROTEC 5 Application Note

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

A full range of monitoring solutions for surge arresters Answers for energy.

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

A full range of monitoring solutions for surge arresters

SICAM AK 3. Flexible automation for all applications. Automation, telecontrol and communication for large data volume.

SIPROTEC Compact Overcurrent Protection 7SJ81 for Low-Power CT and VT Applications

/ sicam SICAM CMIC The smart cube for your distribution network Answers for infrastructure and cities.

Extension of BI/BO for busbar protection SIPROTEC 7SS85

TWO-WINDING TRANSFORMER DIFFERENTIAL

PROTECTION, AUTOMATION & CONTROL

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Maximize protection. Sepam series 10, 20, 40, 60, 80. Modular range of digital protection relays

SIPROTEC 4 7SJ64 Multifunction Protection Relay with Synchronization

Numerical motor protection in medium voltage networks Motor Protection and Control REM620

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

Products Portfolio. Pole mounted Vacuum Recloser

Power Systems Communications Implementation of IEC61850 in a Substation Environment

Automation Unit TM 1703 ACP. SICAM 1703 flexible for all applications. Answers for energy.

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

Go beyond... IEC Leverage the full potential with leading-edge expertise. Answers for infrastructure and cities.

SICAM ertu Your Entry to Telecontrol Technology with Extended Functionality

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

Electrical Integration with Smart Communication

Substation to substation (ss2ss) GOOSE exchange for critical relay operations

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

SIPROTEC 4 7SD61 Differential Protection Relay for Two Line Ends

Application Notes on Generator Protection Schemes

IDS SAS. Station Automation System for Complex Applications

SIPROTEC 5 Application. SIP5-APN-027: Change of switching authority via function keys.

Relion 630 series. Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

Feeder/ Motor Protection Relay VAMP 40

The complete application guide to specifying a Smart-Gear power distribution solution (PDS) E50001-F710-A123-V1-4A00. Answers for energy.

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

e 2 TANGO -400 Overcurrent Relay K Catalogue EN

GPM500 Generator Protection Module

SIPROTEC 5 Protection, automation, and monitoring

SENTRON 3VL Molded Case Circuit Breakers

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

SIPROTEC 5 Devices Protection, Automation and Monitoring

MiCOM P122C Time-Overcurrent Protection

SIPROTEC 5 New features of V7.5

siemens.com/energy/transformers FITformer REG The adaptable distribution transformer Answers for energy.

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note

NPW800R RETROFITTING. Power and Volatge Protection Relay

MiCOM P521. Fast feeder differential protection

The System for Power Automation

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

A low-cost, economical solution for distribution feeder protection

ACOS 300. Reliable protection for network and constructions in medium- and high voltage

MiCOM P521. Fast Feeder Differential Protection

Content REF615 Technical Presentation

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

Non-conventional instrument transformers Advanced GIS substations with IEC LE process bus

Compact Telecontrol System TM 1703 mic. SICAM 1703 flexible for all applications. Answers for energy.

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Secure energy supply Energy Automation for Infrastructure and Functional Buildings

Performance. Simplicity. Sepam, over 20 years of experience of the world leader. Sepam protection relays. For your peace of mind

Clearguard ACM 100 axle counting system. Smart track vacancy detection for cost-effective rail services. siemens.com / mobility

Current Matters. The Device issue. Siemens Protection Devices Ltd. In-depth looks at some of our best and most versatile products to date

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Easily configurable HMI system for power automation siemens.com/sicam

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

Innovative features and solutions for SIVACON S8 siemens.com/sivacon-s8

SICAM RTUs Ready for the Future

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

RelaySimTest. Software for system-based protection testing

Lightweight and flexible recloser control for single-phase applications

DTRV-EP. COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS. Application field

////// SUBSTATIONS. Control command and local Scada

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control

SOLKOR-N (7SR18) Feeder Differential Protection. Make the ight choice! Choose EYROLLE Protection

SWT 3000 Teleprotection siemens.com

ISIO 200. Binary Input/Output (I/O) terminal with IEC interface

Transcription:

www.siemens.com/energy/protection Perfect protection smallest space The SIPROTEC Compact device range redefines protection technology Answers for energy.

SIPROTEC Compact is the ideal solution for almost every protection application Infeed 7SJ80 Backup transformer protection Busbar protection via reverse interlocking Voltage/frequency protection Load shedding Load restoration MV substation 7SD80 Busbar protection via reserve interlocking possible 7SJ80 7SJ80 7SK80 7SJ80 G M 7SD80 7SK80 Cable Generation Transformer Feeder Motor Bus coupler Simple yet comprehensive, safe, and reliable Perfectly suited for protection in distribution systems and industry, with minimal space requirement SIPROTEC Compact devices provide a comprehensive range of functions in a surprisingly compact and space-saving housing. Whether as main or as backup protection, a single SIPROTEC Compact device provides protection functionality for every conceivable fault. And it can do even more it supports the control, automation, and monitoring functions in the substation. Simple to operate and highly flexible The proven concept behind the SIPROTEC Compact range of devices allows effi - cient and safe operation. The devices can be parameterized completely with the DIGSI 4 parameterization tool. The six-line display and eight LEDs indicate all operating states. The new freely programmable function keys can be integrated in the application by the user. With the programmable logic (CFC) and flexible protection functions the device can be adapted to meet the individual requirements in terms of protection for a broad range of applications. Exchangeable communications interfaces will meet future standards, thereby providing security of investment. The comprehensive experience of the market leader in a single device The SIPROTEC Compact range stands for the cumulative experience of millions of successfully operating Siemens systems. They are based on the SIPROTEC 4 range, which has been used in countless systems and applications worldwide to date. Cutting-edge hardware Pluggable terminal blocks make the installation and retrofitting of all voltage and current connections a breeze. No special tools are required, and settings and adaptations are done via software parameters. 2

The SIPROTEC Compact device range SIPROTEC Compact at a glance: the SIPROTEC Compact device range Compact design Simple installation without special tools Six-line display Eight freely assignable LEDs Nine freely parameterizable function keys Pluggable current and voltage terminal blocks Front-mounted USB interface Battery can be exchanged from the front panel Two interfaces for remote access Programmable logic (CFC) and flexible protection functions Binary input voltage threshold adjustable with DIGSI Current transformer rated secondary current (1 A/5 A) adjustable with DIGSI 3

Optical loop and IEC 61850 Parallel operation of control and service connections A strong communicator Much more than a protection device In addition to protection functions, SIPROTEC Compact devices also support control, monitoring, and automation processes. The comprehensive range of features along with communications interfaces ensure that the devices can be fully integrated in the centralized control, supporting control, and service communication. In addition, it provides for connections to be made with other devices, for example via an optical loop according to IEC 61850 with other SIPROTEC 4 devices. Communications interfaces: Interface: - IEC 61850 - IEC 60870-5-103 - PROFIBUS DP - DNP 3.0 - MODBUS RTU Ethernet interface for DIGSI 4 or for optical protection interfaces for differential protection Front-mounted USB interface Features of Ethernet interface for IEC 61850: IEC 61850 with integrated redundancy (electrical or optical) Peer-to-peer communication between devices via Ethernet (IEC 61850 GOOSE) Millisecond-precise synchronization via Ethernet with SNTP Optional optical IEC 61850 loop configuration of SIPROTEC 4 and SIPROTEC Compact devices Ethernet services that can be deactivated 4

Simple parameterization with DIGSI 4 Intuitive user interface with really easy operation DIGSI 4 is the application software on the user s PC for the interface with SIPROTEC devices providing all the related functionality. DIGSI 4 is specifically developed for industrial and utility applications, making the parameterization and evaluation of SIPROTEC devices really easy. The PC software is downward-compatible and provides a user-friendly and intuitive user interface. The interface allows tasks to be carried out simply and conveniently, from the parameterization and commissioning of devices to the analysis and documentation of system disturbances. A powerful analysis tool supports quick fault-finding and also provides important information for maintenance cycles. For a broad range of users, DIGSI 4 has already become an established name in the business. DIGSI 4 at a glance: Mapping of all substation topology types Import and export of parameter sets Flexible and intuitive application of user-defined logic with a logic editor (CFC) no prior programming knowledge is necessary Precise fault analysis and visualization using SIGRA Routing of inputs and outputs with a visually clear matrix (no dialog boxes) Intelligent plausibility checks avoid wrong inputs and settings Test and diagnostics functions Direct interface with the device via a serial interface or from remote via modem Integrated IEC 61850 station configurator 5

7SJ80 VA-B VA-B, VB-C U>, U< U<>, I> Wind farm Time-overcurrent protection 7SJ80 The SIPROTEC Compact 7SJ80 can be used for the line protection of high and medium-voltage networks that have a solid, resistance, isolated, or compensated neutral grounding. The 7SJ80 can be used as a backup protection device for transformer differential relays. Highlights: Multifunction protection in a compact housing Flexible protection functions for the utmost adaptability Ideally suited to energy distribution and industrial networks 6

Time-overcurrent protection 7SJ81 for connecting to low-power current transformers SIPROTEC Compact 7SJ81 makes the advantages of lowpower current transformers available. The device provides four low-power current transformer inputs along with the required protection and control functions. Since low-power current transformers cover a very broad range of primary nominal current while operating almost without saturation, cost-efficient and safe system solutions can be created. Highlights Savings in terms of spares and logistics because only a few low-power current transformer types cover the complete range of conventional transformers while providing protection and measurement CT functionality High operational safety, since low-power current transformers can be operated with short circuit and open circuit on the secondary side Minimal device size of the transformer core, making it ideal for compact switchgear systems in energy distribution and industrial applications Linear and almost no saturation up to short-circuit current Reduction of current transformer types thanks to a high dynamic range and a high precision level In the event of an increase in branch nominal current there is no need for replacement of CT thanks to high, linear transmission range 7

External temperature detection Router Corporate network DIGSI 4/SIGRA 4 Ethernet electrical Switch Router 7TR1200 IP TR1200 IP 1 to 12 RTDs 1 to 12 RTDs SIPROTEC Compact 7SK80 Motor protection 7SK80 The SIPROTEC Compact 7SK80 is a multifunctional motor protection device that has been developed for the protection of asynchronous motors. The 7SK80 can be used as a backup protection for transformer differential relays. Highlights: Highly compact motor protection relay Five integrated inputs for connecting temperature sensors (RTDs) Up to 12 temperature sensors (RTDs) can be connected via a serial-coupled thermobox Overload protection with thermal model and memory function Optimum protection of asynchronous motors of all sizes 8

Line branch with load shedding to protect the entire network from overload Overexcitation protection U> U/f> 59 24 f>; f< U< U> 81 27 59 Further grid φ> Vector jump Decoupling f>; f< U< U> 81 27 59 LR Load restoration f>; f< U< U> 81 27 59 Load shedding/load restoration M Voltage and frequency protection The SIPROTEC Compact has been designed especially for energy distribution applications, for use on transformers, and on electrical machines. It can detect deviations from the permitted voltage or frequency and provides overexcitation protection. The device can also be used for decoupling networks or for load shedding in the event of hazardous network breakdowns arising as a result of impermissibly high frequency drops. The integrated load connection function enables the network to be restored automatically, once the required network frequency has been reestablished. Highlights: Ideally suitable for decentralized generation Network decoupling Load shedding Load restoration Undervoltage/overvoltage and underfrequency/ overfrequency Protection/monitoring Undervoltage/overvoltage protection, underfrequency/ overfrequency protection, and overexcitation protection for generators and transformers Vector surge 9

Station A Station B 7SD80 Fiber optic Twisted pair 7SD80 7SD80 Twisted pair 7SD80 Line differential protection 7SD80 The SIPROTEC Compact 7SD80 line differential protection device can be used for the selective protection of lines in medium-voltage networks with all types of neutral point grounding. For protection data exchange the differential protection uses the integrated two-wire (twisted pair) and FO interfaces in the device. Therefore the 7SD80 can be adapted to existing fibre-optical or copper communication lines which makes it future proof for new investments. The integrated time-overcurrent protection can be directional or non-directional. This allows for the application of protection concepts such as reverse interlocking in meshed networks or emergency mode protection in the event of communication failure. The 7SD80 is perfectly tailored to networks with distributed generation. Highlights: Differential protection for all types of network and neutral point grounding Safe recognition of high and low-resistance faults Efficient protection concepts with powerful additional functions Optimal use of the existing infrastructure with different media for protection-data interface Optional redundant protection-data interface Transfer of circuit-breaker inter-tripping and further binary signals to the opposite end 10

Functions at a glance ANSI Function Abbr. 7SJ80 7SJ81 7SK80 7SD80 Protection functions for 3-pole tripping 3-pole x x x x x 14 Locked rotor protection I> + V< x 21FL Fault locator FL o 24 Overexcitation protection V/f o 27 Undervoltage protection V< o o x o 32F Forward power supervision P>, P< o o 32R Reverse power P>, P< o o 37 Undercurrent I< x x x 38 Temperature supervision x 46 Negative-sequence protection I2> x x x 47 Phase-sequence-voltage supervision V A, V B, V C o o 48 Start-time supervision I 2 start x 49 Thermal overload protection I 2 t x x x x 50 Instantaneous overcurrent I> x x x x 50N Instantaneous overcurrent, ground IE> x x x x 50BF Breaker failure protection x x x x 51 Inverse time overcurrent IP x x x x 51N Inverse time overcurrent, ground IEp x x x x 51M Load-jam protection x 55 Power factor cos φ o o o 59 Overvoltage protection V> o o x o 59N Overvoltage protection, zero sequence system V0> o o x o 66 Restart blocking function I 2 t x 67 Time-overcurrent protection, directional o o 67N Ground-fault protection, directional o o o 67Ns Sensitive ground-fault protection o o 74TC Trip-circuit supervision x x x x x 79 Automatic reclosing function AR o o 81O Over-frequency protection f> o o x o 81U Under-frequency protection f< o o x o 81R Rate-of-frequency-change protection df/dt o o x Vector jump protection φ> o Rate-of-voltage-change protection dv/dt x Load restoration o 86 Lockout x x x x x 87L Differential protection, line ΔI x Switching statistic counters x x x x x CFC x x x x x Inrush detection x x x External trip initiation x x x x x Control x x x x x Fault recording x x x x x Monitoring and supervision x x x x x Protection interface, serial x X: Standard function o: Option 11

Published by and copyright 2011: Siemens AG Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany Siemens AG Energy Sector Power Distribution Division Energy Automation P. O. Box 4806 90026 Nuremberg, Germany For more information, please contact our Customer Support Center. Phone: +49 180 4 70 00 Fax: +49 180 4 24 71 (Charges depending on provider) E-mail: support.energy@siemens.com Power Distribution Division Order No. E50001-G720-A291-X-4A00 Printed in Germany Dispo 06200, c4bs 7439 fb 3630 WÜ 482304 WS 03112. Printed on elementary chlorine-free bleached paper. All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.