Power Management. Reliable and Precise Overview Over Electrical Characteristics and Power. Answers for industry. SENTRON PAC Power Monitoring Devices

Similar documents
Power Management System. Measuring Devices for Power Distribution

Reliable and precise control over electrical systems and power

Power Management System. Multifunction Measuring Instruments

7KT/7KM PAC Measuring Devices

7KT/7KM PAC measuring devices

New Functions and Integrated Communication Capability. The new SENTRON 3VL ETUs SENTRON 3VL. Answers for industry.

with Backlight Graphic LCD Screen

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

SENTRON 3VL Molded Case Circuit Breakers

Uniform parameterisation, operation, and monitoring of intelligent switchboards

FAQ collection for PAC3100/3200/4200

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

SENTRON ATC Automatic Transfer Control Device

SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

SENTRON SIVACON ALPHA

MIC-2 MKII, Multi-instrument DATA SHEET

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

Measuring Devices and

UMG 605. UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC)

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

3VA Molded Case Circuit Breakers

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

UMG 605. UMG 605 Power quality analysers for DIN rails. Flicker. Reporting. Memory 128 MByte.

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information

Combinable for All Applications

3VA molded case circuit breaker. communication SENTRON. Protection devices 3VA molded case circuit breaker communication.

SIMATIC S plus TIA Portal

SENTRON. Power Monitoring Device SENTRON PAC3200. Introduction. Safety instructions 2. Description 3. Operation planning 4.

Quick Start powermanager SENTRON. Software Quick Start powermanager. Introduction. Installation. Starting the project 3

FOUR FUNCTIONS ONE SOLUTION

SIMATIC ET 200SP and ET 200MP

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

Usage of the digital inputs of SENTRON PACs

powermanager SENTRON Software for supporting a power management system in accordance with ISO Answers for infrastructure and cities.

PQM - Power Quality Monitoring

The innovative interface for the last few meters to the process

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

Innovative features and solutions for SIVACON S8 siemens.com/sivacon-s8

Savings Potential through Transparent Energy Flows

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Make the sun your energy source. SOLAR

PQM - Power Quality Monitoring

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

PQM - Power Quality Monitoring

powermanager SENTRON Software for supporting a power management system in accordance with ISO Answers for infrastructure and cities.

Flexible insurance against downtimes. SIMATIC S7-400H: high availability and safety in one system based on PROFIBUS and PROFINET

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument

Automation meets IT. SCALANCE X-500 central interface between Industrial Ethernet and IT networks SIMATIC NET. siemens.

General information. Display. Supply voltage

Digital Multifunction Meters. Digital Multifunction Meters

For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

Online data sheet MEAC CEMS SOLUTIONS

Digital multimeters DMG

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

Siemens AG PAC3200 Multifunction Measuring Instruments and Expansion Modules. Catalog News LV 1 N June 2008 SENTRON

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

PQM - Power Quality Monitoring

SINAMICS DCM Cabinet. DC drive converter cabinets for fast and simple system integration. siemens.com/sinamics. Answers for industry.

General information. Display. Supply voltage

Power monitoring made simple Easy safe cost-efficient

EngyVolt RV12 and RV15

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

7KM2112-0BA00-3AA0 SENTRON PAC3200. English. Operating Instructions DANGER CAUTION DANGER. Order-No.: A5E Last update: 18 January 2008

POWER MEASUREMENT IN ELECTRICAL SYSTEMS SIRAX MONITOR SERIES BUILT-IN DEVICES FOR MEASUREMENT IN POWER SYSTEMS

THE NEXT TRANSDUCER GENERATION

Miniature Circuit Breakers for Railway Applications

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

MARINE & OFFSHORE SHIP ENERGY MONITORING SYSTEM

SICAM ertu Your Entry to Telecontrol Technology with Extended Functionality

o SIPLUS LOGO! MODULAR BASIC VARIANTS

6-Channel power analyser UMG 96RM-E. Operating current and RCM fault current monitoring. Smart Energy & Power Quality Solutions RCM.

RUGGEDCOM RMC8388. Rugged Media Converter. siemens.com/rmc8000. Edition 10/2015. Brochure

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Smart Energy & Power Quality Solutions. UMG 507 Power analyser

SIMEAS Q80 quality recorder: Voltage quality starts with measurement.

CPU module for zone 2 Series 9442/35

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

General information. Display. Supply voltage. Input current. Encoder supply. Output current

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

/ sicam SICAM CMIC The smart cube for your distribution network Answers for infrastructure and cities.

The 3VA molded case circuit breaker.

Smart Energy & Power Quality Solutions. UMG 103-CBM energy meter with memory COMPACT, BEST-PRICED & SAFETY

General information. Display. Supply voltage. Input current. Encoder supply. Output current

POWER SIMPLY SAVE. Catalogue Catalogue 2017

General information. Supply voltage

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Transcription:

Reliable and Precise Overview Over Electrical Characteristics and Power SENTRON PAC Power Monitoring Devices Power Management Answers for industry.

When and where is how much power consumed? SENTRON PAC makes consumption apparent A sustainable reduction of power costs first requires an analysis of the electrical system s current consumption and power flows. This is supported by our SENTRON PAC3200 and SENTRON PAC4200 power monitoring devices. They precisely and reliably detect the power values of electrical feeders and individual consumers. In addition, they provide important measured values for assessing the system state and power quality. Whether in industrial applications or commercial buildings our SENTRON PAC power monitoring devices can be employed wherever electric power is distributed. They detect various measuring values and comfortably illustrate them on a graphical LC display. For further processing of the measured data, the devices can be very easily integrated in superior automation and power management systems, for example in our SIMATIC PCS 7 powerrate and SIMATIC WinCC powerrate software packages. Precise power measuring matched to your needs The two power monitoring devices provide accurate knowledge of your systems characteristics with maximum, minimum and average values for voltage, current, power values, frequency, power factor, symmetry and THD. While the SENTRON PAC3200 detects more than 50 basic values, the SENTRON PAC4200 offers a total of 200 values with further relevant data regarding the power quality. Both devices feature 10 power counters for comprehensive load detection. Their measuring accuracy meets the high requirements found in the power counter standards, thanks to which they are excellently suited for internal accounting. The SENTRON PAC4200 offers a considerably higher measuring accuracy than its smaller brother. Moreover, its on board logging capabilities and individually configurable screen displays provide additional comfort and for ease of evaluation of the data. 2

Fast and space-saving installation Minimum space requirements thanks to compact design: Panel-mounting format: 96 x 96 mm (3.78" x 3.78") Installation depth in switch panel: SENTRON PAC3200: 51 mm (2"), 73 mm (2.88") with expansion module SENTRON PAC4200: 77 mm (3"), 99 mm (3.89") with expansion module Easy mounting: Mounting without tools with easily latching retainers; additional support of uncomplicated screw fastening for increased degree of protection Easy operation and configuration Intuitive menu prompt via 4 function keys Plain text displays in 9 languages Optimum readability of the LC display thanks to adjustable background illumination Time-saving configuration of multiple devices via free SENTRON powerconfig software (included with each device) Versatile application range Direct connection to industrial networks up to 690 V, CAT III Support use of potential transformer Connection to current transformer x/1 A or x/5 A Application in systems with UL/CSA requirements Application in harsh environments: dust and splash water protection (IP 65 / NEMA 12) through standard spray-on sealing Developed and tested in accordance with European and international standards 3

From integrated communication Our power monitoring devices facilitate flexibility thanks to multiple communication options. Whether PROFIBUS DP, Modbus RTU or Ethernet with Modbus TCP integration in superior systems is ever so easy with the SENTRON PAC3200 and SENTRON PAC4200. Ethernet on board Both the PAC3200 and PAC4200 come standard with an Ethernet interface built in making additional hardware unnecessary saving space and money. The devices can be configured via LAN networks and reliably provide measured data via Modbus TCP. Yet, the flexible power monitoring devices offer further alternatives for integrated data transmission: PAC PROFIBUS DP expansion module Data transmission via PROFIBUS DP, cyclic and acyclic data traffic via PROFIBUS DPV1 Transmission rates of up to 12 MBit/sec Easy (plug-in) mounting on rear device side PAC RS485 expansion module Data transmission via Modbus RTU and SEAbus Transmission rates of up to 38.4 kbd Easy (plug-in) mounting on rear device side Digital inputs and outputs The SENTRON PAC3200 features one multifunctional digital input and output each and the SENTRON PAC4200 comes with two multifunctional digital inputs and outputs. One of up to six possible functions can be independently assigned to every input and output according to your individual requirements. This provides you with maximum flexibility and reduces the implementation costs for system adjustments. Integrated Ethernet interface Digital inputs and outputs PAC PROFIBUS DP expansion module PAC RS485 expansion module 4

to systematic power management Exploit the full potential of our power monitoring devices by integrating them in a superior power management system. The precise and comprehensive measuring functions of the SENTRON PAC3200 and SENTRON PAC4200 provide the required measured data. Together with power management add-ons and block libraries, Siemens offers an innovative and future-proof solution for optimized power utilization with up to 20 % saving potentials in terms of power costs. SIMATIC PCS 7 powerrate and SIMATIC WinCC powerrate Power management par excellence based on tried-and-tested industrial technology: Our power monitoring devices can be easily coupled with the SIMATIC PCS 7 powerrate and SIMATIC WinCC powerrate power management add-ons. Comprehensive measured value detection and processing as well as cost-by-cause allocation support the transparency and control of your power distribution system and costs. The load management functionality represents a further highlight. This feature monitors the power limit agreed with the power supplier and controls the consumption if required. System integration via block libraries The optionally available block libraries support the easy integration of the SENTRON PAC devices in the SIMATIC PCS 7 process control system and the SIMATIC WinCC SCADA system. Together with the faceplates, the driver and diagnostics blocks in the control serves as the user interface for operating and monitoring. This way, all technologically important values and functions of the power monitoring devices can be easily displayed and used in the respective target system. Faceplates Industrial Ethernet PROFIBUS S7 drivers/blocks 5

SENTRON PAC3200 The basis for reliable and precise measuring Flexible The SENTRON PAC3200 detects more than 50 electrical characteristics such as voltages, currents, ratings, power values, frequency, power factor, symmetry and THD. In addition to the current measured value, the minimum and maximum values are detected for the measuring values (non-return pointer function). The SENTRON PAC3200 is designed for measuring applications in singleor multi-phase networks with and without neutral conductor. A particularity of this device is that it supports the direct measuring of phase voltages up to 830 V. The SENTRON PAC3200 can thus be employed in 690 V networks. Furthermore, measuring via potential transformers is possible with the transformation ratio respectively adjustable. The current inputs are dimensioned for measuring on x/1 A or x/5 A current transformers. The SENTRON PAC3200 detects the values for active, reactive and apparent energy both for high and low tariff. It measures ratings and power values via the four quadrants, i.e. power import and export are measured separately. The SENTRON PAC3200 also facilitates the detection of a measuring period s average values for active and reactive power. These values can be further processed into load curves in a power management system. Typically, 15-minute intervals are used for this purpose. and precise measuring The measuring accuracy are 0.5 % for active energy and power and to 0.3 % for voltages and 0.2 % for currents. The device allows for the monitoring of up to six parameters for an upper or lower limit value. The six limit values can be interlinked via the integrated logic function. The SENTRON PAC3200 is equipped with one multifunctional digital input and output as a standard. The output can be used as pulse or switching output or for limit value signaling. The input can, for example, be used for switchover between high and low tariff detection or for the pulse counting of power counters with S0 interface. 6

Features Basic measuring values PAC3200 PAC4200 Voltage L-L, L-N, 3-phase average Current Per phase, 3-phase average Neutral conductor current Apparent power Per phase and total Active power Per phase and total Total reactive power Per phase and total Fundamental wave reactive power Per phase and total Power factor Per phase and total Fundamental wave power factor Per phase Frequency Of import phase Min./max. values / date and time Non-return pointer function / / Moving average values U, I, S, P, Q, LF Extended measuring values Phase displacement angle Between voltage and current per phase Phase angle Between phase voltages THD voltage Per phase THD-R (U L-N ) THD (U L-N & U L-L ) THD current Per phase THD-R (I L1..3 ) THD (I L1..3 ) Harmonics voltage Per phase 3 rd to 31 st Harmonics current Per phase 3 rd to 31 st Distortion current strength Per phase Max. values / date and time Non-return pointer function / / Asymmetry voltage / current 3-phase system U nba / I nba U nb / I nb Power detection / counters Apparent energy Continuous counter total energy Active energy Continuous counter total energy Import and export Reactive energy Continuous counter total energy Import and export 2 tariff counters (HT / LT) Apparent, active, reactive energy Daily power values for 365 days Apparent, active, reactive energy Power demand of last measuring period Active and reactive power average value Measuring period Adjustable in minutes Min./max. values of ratings Within the measuring period Operating hours counter Operating period consumers Universal counter Multifunctional Monitoring functions Limit value monitoring Max. number of limit values 6 12 Boolean logic AND, OR / NAND, NOR, XOR, XNOR / / Limit values / inputs Logically interlinkable / /

Recording functions PAC3200 PAC4200 Load curve recording Apparent, active, reactive power average values Min./max. values Per measuring period Recording period With 15-min. measuring period 40 days Synchronization Digital input, bus, internal clock Adjustable averaging Arithmetic or accumulated Recording methods Fixed block or rolling block Event recording Max. number of events > 4000 Priority control Selectable warning levels Adjustable acknowledgement requirement Selectable event storage Interfaces Ethernet (integrated) For twisted-pair cables 10 Mbit/sec 10/100 Mbit/sec Interface functions Auto-negotiation / auto MDI(X) Number of connections Simultaneous 1 3 Protocol Modbus TCP Gateway Ethernet RS485 (Modbus) PROFIBUS DPV1 Via PAC PROFIBUS DP module Optional expansion module Modbus RTU Via PAC RS485 module Optional expansion module Inputs / outputs Digital inputs Multifunctional 1 2 Digital outputs Multifunctional 1 2 Operating voltage DI/DO Nominal value 24 V DC 24 V DC Clock / calendar Real-time clock Second-accurate time stamp Calendar function Adjustable date and time format Summertime / wintertime switchover Automatic (US/EU) or manual Fault limits Voltage / current Referred to the measured value 0.3 % / 0.2 % 0.2 %* Apparent / active / reactive power Referred to the measured value 0.5 % / 0.5 % / 2 % 0.5 % / 0.2 % / 1 % Active energy According to 62053-22 Class 0.5S Class 0.2S Reactive energy According to 62053-23 Class 2 Class 2 Display / operation Display LCD graphical display with background illumination Indication Alphanumeric and text Fully graphical Operation Menu prompt via function keys Languages Selectable on the device GER, ENG, PT, TR, ES, IT, FR, CHN, RU User-definable indication Bar or digital indication 4 * Complies with the stated function-related accuracy classes in accordance with IEC 61557-12 U nba I nba Asymmetry with regard to amplitude U nb I nb Asymmetry with regard to amplitude and phase

SENTRON PAC4200 Comprehensive and comfortable overview of the system state You require detailed knowledge of your system s state? Then the SENTRON PAC4200 is the right solution for you. It detects approximately 200 electrical characteristics. In addition to over 50 basic values, which are also provided by the SENTRON PAC3200, you can thus also generate measured data for assessment of the power quality. Besides the THD for three- and four-conductor networks, the PAC4200 also detects uneven harmonics from the 3rd to the 31st for voltage and current, the distortion current strength (I d ), the phase angle and the asymmetry for voltage and current with reference to the amplitude and phase. This facilitates early counter-measures against interferences, e.g. caused by mains pollution. Maximum precision and safety The PAC4200 sets new precision standards in its device class. With an accuracy of 0.2 % for voltages, currents, active power and energy, referred to the measured value in accordance with IEC 61557-12, this device is not only highly precise, but also complies with the latest standards. This guarantees the power monitoring device s suitability regarding the requirements of modern industrial systems in terms of performance, safety and operating behavior. Comprehensive storage functions The SENTRON PAC4200 stores load curves in its internal memory. Apparent, active and reactive power average values are stored over a period of 40 days with a 15-minute measuring period. These data form the basis for an accurate determination and optimization of your system s utilization for reduced power costs and improved system efficiency. The PAC4200 supports the recording of more than 4000 operating and system events, which can be individually adjusted. With an integrated real-time clock, all events can be traced accurate to the second. This saves valuable troubleshooting time in case of faults. User-defined screen displays A total of four individually configurable screen displays offers further comfort. You can have the values displayed as bar chart or have them compiled as digital indication to gain a rapid overview of your system s state directly on the device. Integrated gateway function The integrated gateway function of the SENTRON PAC4200 allows for the convenient integration of devices with simple serial RS485 interface in an Ethernet network. This way, several subordinate devices, e.g. simple measuring devices or circuit breakers, can send their data to the SENTRON PAC4200 via Modbus RTU. The SENTRON PAC4200 for example forwards this data to a supervising power management system via its integrated 10/100 MBit/sec Ethernet interface. Connection of Modbus RTU devices to a power management system via SENTRON PAC4200 SQL database Server Client Client Ethernet SENTRON PAC4200 with serial gateway Modbus RTU SENTRON PAC3200 SENTRON VL SENTRON WL Multifunction measuring devices 9

Technical data SENTRON PAC3200 Applicable for TN, TT, IT networks Continuous signal detection SENTRON PAC4200 Measuring / supply voltages Measuring inputs for voltage 3 AC; UL-L/UL-N; CAT III Max. 690 V / 400 V Wide voltage power supply unit AC/DC 95 to 240 V AC 50/60 Hz ±10 % 110 to 340 V DC ±10 % Measuring inputs for voltage 3 AC; UL-L/UL-N; CAT III Max. 500 V / 289 V Extra-low voltage power supply unit DC 22 to 65 V DC; ±10 % Measuring on voltage transformers For voltages > 500 V or 690 V Measuring inputs for current 3 AC; CAT III x/1 A or x/5 A Current direction programmable Per phase Measuring via current transformer Mechanics Dimensions W x H x D [mm] 96 x 96 x 56 96 x 96 x 82 Installation depth without module [mm] 51 77 Installation depth with module [mm] 73 99 Protection class II II Degree of protection Front IP65 IP65 Slots for expansion modules Number 1 2 Operating temperature C 10... +55 10... +55 Relative humidity during operation Up to 25 C without 95 % 95 % condensation Pollution degree 2 2 Approvals CE Europe culus USA / Canada C-Tick Australia In preparation GOST Russia Accessories PAC PROFIBUS DP expansion module (optional) Parameterizable via device front or parameterization software Selection of measuring values to be transmitted via GSD file Transmission rate Protocol PAC RS485 expansion module (optional) Parameterizable via device front or parameterization software Transmission rate Protocol 9.6 Kbit/sec to 12 Mbit/sec DPV1 Optionally 4.8 / 9.6 / 19.2 / 38.4 kbd Optionally SEAbus or Modbus RTU (selectable) 10

Ordering information Product U c Order number SENTRON PAC3200 power monitoring device 95 to 240 V AC 50/60 Hz ±10 % 7KM2112-0BA00-3AA0 with AC/DC wide voltage power supply unit and screw terminals 110 to 340 V DC ±10 % SENTRON PAC3200 power monitoring device with DC extra-low voltage power supply unit and screw terminals 22 to 65 V DC ±10 % 7KM2111-1BA00-3AA0 SENTRON PAC3200 power monitoring device with AC/DC wide voltage power supply unit and ring cable lug terminals SENTRON PAC4200 power monitoring device with AC/DC wide voltage power supply unit and screw terminals SENTRON PAC4200 power monitoring device with AC/DC wide voltage power supply unit and ring cable lug terminals 95 to 240 V AC 50/60 Hz ±10 % 110 to 340 V DC ±10 % 95 to 240 V AC ±10 % 110 to 340 V DC ±10 % 95 to 240 V AC ±10 % 110 to 340 V DC ±10 % 7KM2112-0BA00-2AA0 7KM4212-0BA00-3AA0 7KM4212-0BA00-2AA0 Accessories Product Order number PAC PROFIBUS DP expansion module DPV1; up to 12 MBit/sec 7KM9300-0AB00-0AA0 PAC RS485 expansion module Modbus RTU / SEAbus up to 38.4 7KM9300-0AM00-0AA0 kbd SIMATIC PCS 7 Library PAC3200 Engineering + runtime license 3ZS2781-1CC10-0YG0 Runtime license 3ZS2781-1CC10-6YH0 Library PAC3200 Engineering + runtime license 3ZS2791-1CC10-0YG0 for SIMATIC WinCC Runtime license 3ZS2791-1CC10-6YH0 Information on the SIMATIC PCS 7 powerrate and SIMATIC WinCC powerrate power management add-ons as well as on the power management system is available at www.siemens.com/powermanagementsystem 11

For further information... please contact your local Siemens sales partner. For technical questions, please contact: Technical Assistance Tel.: +49 (911) 895-5900 E-mail: technical-assistance@siemens.com Siemens AG Industry Sector Low-Voltage Controls and Distribution P.O. Box 48 48 90026 NÜRNBERG GERMANY www.siemens.com/powermanagementsystem Subject to change without prior notice 01/09 Order No. E20001-A460-P307-V3-7600 Dispo 27605 2100/17907 EVPM.52.9.03 PA 01097.0 Printed in Germany Siemens AG 2009 The information provided in this brochure contains merely general descriptions or characteristics of performance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.