AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

Similar documents
AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

Digital Modules AS-i, IP67, M12

Analog Modules AS-i, IP67, M12

Digital Modules AS-i in IP20, 22,5 mm

AS-i 3.0 motor module

AS-i 3.0 Motor modules

AS-i Safety Input Modules (M12), IP67

AS-i 3.0 motor modules

Active Distributors AS-i Safety, Active Distributors AS-i

Analog Modules AS-i IP65, M12

AS-i Safety Output Module, IP20

Active Distributors ASi Safety, IP67

PCB AS-i modules, board based solutions

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O

Encoder signal/ Sensor signal. Number of monitored axes. sine/cosine, SSI, TTL (1) up to 2 independent axes. sine/cosine. up to 2 independent axes

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor

AS-i Safety Analog Input Module, IP20

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 EtherCAT Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-Interface I/O Module

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017

Operating instructions. ProcessLine analogue module AC / / 2012

Installation Instructions Temperature transmitter TAA /00 06/2011

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No

Magnetically Actuated Safety Interlock Switches

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident no

Diagnostics (Logical) Diagnostics (Physical)

VersaMax IP I/O Module

Operating instructions valve control box AS-i

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

EtherNet/IP. Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

GS202 Encoder Switch

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

Magnetically Actuated Safety Interlock Switches

Protected VARAN Digital Mixed Module PVDM 086

Device manual AS-i PowerSwitch ZB0028 ZB0040

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

Inductive proximity sensors IQ 40 series, sensing range 15 / 20 mm DC 3-wire, plastic housing

BNI IOL-104-S01-Z012-C02

Programmable Set for Ethenet/IP in IP67 TI-BL67-PG-EIP-2

Diagnostics (Logical)

Sensor boxes SRBG Key features

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection

Programmable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45

Faults on the system Proximity switch connection technology:

Operating instructions AC010S Compact AS-i E-STOP safety module

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

TM221ME32TK controller M IO transistor PNP Ethernet

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Operating instructions Memory plug E /02 11/2011

Expansion Module HZS 541-1S

TABLE OF CONTENTS AS-INTERFACE

SITOP in the SIMATIC Design

Technical Description

AS-interface modules CESA

MobileView Junction Box

AS-i Safety Relay Output Module with Diagnostic Slave

IT power distribution Power distribution units (PDU) Basic. Versions available:

Operating instructions RFID evaluation unit DTE / / 2016

Compact Coded Magnetic Safety Interlock Switch and Control Units

RSTI-EP Slice I/O. Digital Output Module

Operating instructions. Switching amplifier DN0210 DN / / 2015

TM221CE24R controller M IO relay Ethernet

GFK-2415A March Type of sensor connection

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

Datasheet AZM 161 Z ST1 AS RA

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

INTEGRUS BOSCH DIGITAL INFRA-RED LANGUAGE DISTRIBUTION SYSTEM. Installation and Operating Manual

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Multiturn absolute encoder

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Transcription:

/ IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master single in one housing Power supply of s out of AUX (or ) Figure Type Inputs digital 8x M 8x M 4 x + 4 x + Outputs digital 4x 4x 8x M 4 x 4x M wiring class A class A Class B Input voltage (sensor supply) out of AUX out of out of Output voltage (actuator supply) out of AUX out of out of connection 3 address 4 single single single Max. output current Art. no. 500 ma BWU853 0 ma BWU945 5 0 ma Input voltage (sensor supply) Inputs are supplied by or by AUX (auxiliary 4 V power). If supplied by, inputs can neither be connected to earth nor to external potential. Output voltage (actuator supply) The supply of the outputs is made by or by AUX (auxiliary 4 V power). By supply out of there is no connection to earth or external potential allowed. 3 connection The connection to as well to AUX (auxiliary 4 V power) is made via yellow or black with piercing technology or via M socket (in IP0 via clamps). 4 address AB slave (max. 6 AB / network), AB (max. 3 modules with AB ), single (max. 3 single / network), mixed use allowed (upon request, are available with specific AS-slave profiles). 5 Only on request. www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 5.6.4 page

/ IO-Link Module, Article no. BWU853 Connection /AUX connection and piercing Periphery connection M Length of connector cable I/O: max. 0 m IO-Link Number 4 ports Data rate COM / COM / COM3 IO-Link revision. Profile slave : S-7.5.5 (ID=F default) slave : S-7.5.5 (ID=E default) Address single Operating voltage 30 V (8 3.6 V) 30 V (4 3.6 V) Required master profile M4 Since specification 3.0 Max. current consumption 50 ma 00 ma Max. current consumption without 50 ma 80 ma sensor / actuator supply AUX Voltage 4 V (8 30 V) Max. current consumption 4 A Input Number 4 (via ) + 4 (via ) Power supply out of AUX out of Supply of attached sensors 500mA per port, (sensors + outputs) max. A (sensors + outputs) max. 0 ma 3 Switching threshold U<5 V (low) U>5 V (high) Output Number 4 (via ) Power supply out of AUX out of Max. output current 500 ma per port, (sensors + outputs) max. A (sensors + outputs) max. 0 ma 3 Display LED ASI (green) LED FLT/FAULT (red) LED AUX (red/green) LEDs P... Pn (red/green) on: no data exchange flashing: AUX voltage missing, overload sensor supply, overload output or IO-Link error on: voltage on off: no voltage green: AUX voltage OK red: AUX voltage < 8 V state of P... P4 green: IO-Link communication OK yellow: switching signal at input or output red: IO-Link communication error on: no data exchange flashing: overload sensor supply, overload output or IO-Link error page Mannheim, 5.6.4 We reserve the right to change any data www.bihl-wiedemann.de

/ IO-Link Module, Article no. BWU853 Environment Applied standards EN 6000- EN 6000-3 EN 6 3- Operating temperature -30 +70 Storage temperature -30 +85 Housing plastic, for DIN rail mounting Protection cat. (EN 6059) Max. tolerable shock and vibration stress Isolation voltage 5 g, T ms 0... 55 Hz, 0,5 mm amplitude 500 V Dimensions (W / H / D in mm) 60 / 5 / 3 Weight 00 g Derating total current out of AUX I Σ (AUX) A 4 40 70 BWU853 Derating total current per port I Port max. A 0,5-30 0 5 70 www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 5.6.4 page 3

/ IO-Link Module, 3 Derating total current out of I Σ (Sensors and outputs) ma 0 80 40 70 Programming bit assignment Bit D0 D D D3 Input BWU853 / Slave : P-I Slave : P-I Slave : P3-I Slave : P4-I Output BWU853 / adjustable adjustable BWU853 / Parameter bit P0 P P 0=data mapping 0= IO-Link parameter 0= manual setting of adjustable backup active port configuration = default data mapping activated = no IO-Link parameter backup Via process data mapping and IO-Link gateway configuration adjustable. Plug and Communication mode is not usable with digital outputs (actuator without IO-Link). Digital inputs are frozen during IO-Link wakeup sequence. = plug and comm mode active Pin assignment Signal name Explanation 4 V ext out power supply, out of external voltage, positive pole (AUX, actuator supply) 0V ext out power supply, out of external voltage, negative pole (AUX, actuator supply) I digital input L+ out power supply, out of, positive pole (IO-Link, sensor supply) 0V out power supply, out of, negative pole (IO-Link, sensor supply) I/O/Com connection optionally for input, output or IO-Link communication page 4 Mannheim, 5.6.4 We reserve the right to change any data www.bihl-wiedemann.de

/ IO-Link Module, Connections Art. no. M Marking Function Pin Pin Pin3 Pin4 Pin5 connection assignment P P 4 V slave ext out I 0 V ext out I/O/Com nc X P P 4 V ext out I 0 V ext out I/O/Com nc BWU853 P3 P3 4 V slave ext out I3 0 V ext out I/O/Com3 nc X4 P4 P4 4 V ext out I4 0 V ext out I/O/Com4 nc (dummy plug) connection for addressing device P P L+ Slave out 4 V ext out 0V out I/O/Com 0 V ext out X P P L+ out 4 V ext out 0V out I/O/Com 0 V ext out P3 P3 L+ Slave out 4 V ext out 0V out I/O/Com3 0 V ext out X4 P4 P4 L+ out 4 V ext out 0V out I/O/Com4 0 V ext out (dummy plug) connection for addressing device X X4 3 4 5 Accessories: substructure module (CNOMO) for 8 channel module in 60 mm housing (art. no. BW35) Protection caps for unused M sockets (art. no. BW368) www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 5.6.4 page 5