Hydraulics with IO-Link: Reduced effort, high value

Similar documents
IO-Link System Description. Technology and Application

IO-Link System Description Technology and Application

Inductive sensors with IO-Link interface

SafeLogic compact Safety in a small format

Temperature module. 4 inputs for thermocouples

FIELDBUS OVERVIEW Graham Traill 02/09/2015

Parametrization instead of programming: HACD-2X Standard Motion Control for electrohydraulic axes

Technology modules. 1 SSI interface for absolute encoders, 1 analog output S20-SSI-AO-1/1

Communication modules. Serial interface module

Analog input module. 4 inputs, voltage and current

Digital I/O modules. 8 inputs/outputs, M8

Temperature modules. 8 inputs for connection of thermocouple sensors S20-AI-8-UTH

Servo drives. SafeMotion

Modular I/O system. Power module

Consistent Automation Solutions for Electrohydraulic Drives in Times of Industry 4.0

Fieldline. 4 digital inputs, 4 digital inputs/outputs RF-FLM DIO 8/4 M8

Temperature module. 4 inputs for resistance thermometers

digsy ServiceLink Remote Data Transmission GSM + GPS for mobile outdoor machinery Printed in Germany

IndraDrive Mi Intelligent, decentralized drive technology

IO-Link Design Guideline

IO-Link for more Production Efficiency

Safety modules. 8/4 inputs PROFIsafe S20-PSDI8/4

Fieldline. Fieldline Modular bus coupler, PROFIBUS, 8 digital inputs 24 V DC, M12 RF-FLM BK PB M12 DI 8 M12

The economical solution for continuous communication in automation

The innovative interface for the last few meters to the process

SafeLogic compact. CPU module (EFI, ACR) SLC-3-CPU3

HNC100-3X Programmable motion control for electrohydraulic drives

Your Global Automation Partner. IO-Link: Simple, Seamless, Efficient

IndraDrive Mi cabinet free for highest flexibility and efficiency

Preface. Guide SIMATIC. System overview. Integration into the automation system 3. IO-Link system. Function Manual 12/2017 A5E AB

DESINA installation technology

Integrating IO-Link Devices into CIP Networks

Linear Motion and Assembly Technologies Pneumatics Service. Choosing an Electrohydraulic Controller

FIELDBUS TRAINING 1.01

IO-Link point-to-point communication.

General. Remote I/O A4/1.

HMI/industrial PC. Plug-in card Sercos master module Sercans

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

Intelligent vibration monitoring.

Functional Safety for Electronic Control

SIMATIC ET 200SP and ET 200MP

LION SAFE Remote I/O System. LÜTZE TRANSPORTATION GMBH Dimitrios Koutrouvis V00

Application of CIP Safety for functional safety in motion applications - analysis of CIP Safety motion application use case scenarios

Line Coupler, MDRC LK/S 3.1, GH Q R0001

At Miele, Beckhoff bus terminals represent the corner points of remote automation

ECONOMICAL INSTALLATION CONCEPTS. Murrelektronik is your partner. ÔÔMetal cutting machine tools. ÔÔAssembly and handling equipment

Design Benefits. Teo Puay Yong Pepperl+Fuchs. On Behalf of FF Marketing Society. The Future is Digital. 1 The Future is Digital

Electric Drives and Controls. Integrated Motor/Drive technology with Rockwell connectivity

Rexroth IndraDrive Cs Multiprotocol-capable compact drives

IO-Link What is it? 2

Diagnostics (Logical) Diagnostics (Physical)

Partner Product Valve island AirLINE SP Type 8647 for ET 200SP. unrestricted

Power distribution system SVS16-PB

IndraLogic L Controller based

AS-i Safety Relay Output Module with Diagnostic Slave

IndraMotion MLC Motion Logic System for Hydraulic Drives

Control hardware. IndraControl L75

Control blocks CPX-CEC- -V3

Keeping the Lights On: Machine Monitoring Basics

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

Synchronized motion control functionality IndraWorks The Tool for All Engineering Tasks

Compact Power for Decentralized Applications MOVIPRO SDC/ADC

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ]

Protected VARAN Digital Mixed Module PVDM 086

Providing flexibility. Simplifying integration. Opening communication channels. RFID Read/Write Heads with IO-Link

The LVS Directional Valve with Digital Pilot Control A New Generation

Digital closed-loop control electronics

Siemens AG UG46 PLC. 1 Analog. 2 signal. 3UG48 monitoring relay

Micropulse Transducers

Electrical Demand Specification (Reference SOP: )

products PC Control

IndraDrive Mi Cabinet-free Drive Technology for highest Flexibility and Efficiency

FAQs for Background. 1. What is Open Core Engineering?

WAGO-I/O-SYSTEM 750 IO-Link Master

DC561, digital input/output module,

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system and / or counter inputs

Point-to-point communication.

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Industrial Revolutions. Smart Industry / Industry 4.0

INFO GMM EC. Advanced controls system for ECOSS. The New Choice In Evaporative Cooling

New Product Bulletin. Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications

Rexroth IndraMotion MLC The innovative Motion Logic system

INTELLIGENT PROGRAMMABLE DRIVES BECOME A CONTROL FOR THE ENTIRE MACHINE

HIMA specialist essay Integrated safety controllers with safeethernet.

Electronic Control Unit RC

Digital command value and controller card. Type VT-HACD-1. Contents. Features. RE Edition: Replaces: 04.12

DC562, digital input/output module,

Cube20. Application-oriented. Installation-friendly. Efficient

Partner for automation Water technology

07. har-link INTERFACE CONNECTORS

Future has begun - IO-Link Application stories

Service case with test unit for servo-valves without integrated electronics

PROFINET The industrial Ethernet standard. This is my way

Functional Principle and the resulting Benefits.

Servo Drives. Compact Drives IndraDrive Cs

Quick Disconnect vs. Hard-Wiring: Selecting A Connectivity System For Your Industrial Application

LioN-Power IO-Link System Multiprotocol IO-Link Masters and I/O Hubs

DI561 Digital Input Module

Simple Machines success stories Build together...

Transcription:

Hydraulics with IO-Link: Reduced effort, high value

Standardized wiring and electronic name plate support commissioning and increase availability Open standard for bi-directional point-to-point connections in parallel to field bus Easy connection with standard cables and M12 connectors No additional engineering tool necessary, possible configuration via control system. Data for predictive maintenance and quick device replacement Industry 4.0-compatible hydraulic components for vertical flow of information Abstract: In almost all industries, machine users require increased flexibility for production means for small batches and continuous diagnostics of all actuators and sensors to increase availability. In addition to this, there is quickly increasing horizontal and vertical connection of machinery and systems for Industry 4.0 applications. The open standard IEC 61131-9, IO-Link, fulfills these requirements at low connection costs and energy consumption. Flexibility of hydraulics is increased by transmission of parameter changes in running operation. Provision of diagnostics information offers numerous opportunities to extend the concepts of predictive maintenance for hydraulics to increase availability of systems and machinery. The manufacturer-independent IO-Link can be integrated easily and quickly in any industrial automation application. Introduction: Limits of serial field bus communication The introduction of field bus technology in the 1980s was the starting point for horizontal connection of decentralized actuators within machinery. Serial wiring lead to a considerable reduction in cabling and opened new possibilities for modularization in mechanical engineering. Field buses as well as most current real-time Ethernet protocols are manufacturer-specific, proprietary systems. The protocols have been developed by control system manufacturers and focus on communication between own electric control systems and selected peripherals. For actuators, sensors and other third-party equipment, either their manufacturers or system integrators are required to provide suitable interfaces in hardware and software for the respective field bus. This is very complex as device profiles and software have to be created in the respective PLC for every individual field bus and control system of each manufacturer. Possibilities for hydraulic connection Integration of hydraulics in modern automation systems can be realized in different ways. Numerous existing machine concepts apply on-board electronics for control of hydraulic valves. Exchange of digital information is restricted and only possible if the respective device is connected to a superior control system via individual wiring. This state-of-the-art in technology increasingly no longer meets the requirements of end users. The alternative are valves with integrated field bus connection. These, however, require extensive wiring as well as integration into the control system and the respective field bus protocol by means of dedicated software. Both requires considerable effort that is too high particularly for price-sensitive applications. Thanks to IO-Link, machine manufacturer and system integrators are enabled to integrate for example proportional hydraulic series valves and sensors into digital communication structures with very little engineering effort. With its simple communication structure, IO-Link has low hardware requirements. Additionally, the standardized M12 connection technology enables simple and cost-efficient connection of hydraulic valves in the field. This way, previously "deaf-mute" components with analog control are transformed in communicating and flexible actuators and sensors. IO-Link: Manufacturer-independent and compatible with all field bus protocols The manufacturer-independent IO-Link according to IEC 61131-9 standardizes connection technology for actuators, sensors and other equipment and provides a digital communication protocol for data exchange between control systems and devices regardless of the field bus. Field bus technology is not replaced but extended. Parallel communication enables machine manufacturers use of IO-Link with all protocols and integration of IO-Link-compatible devices into various concepts without additional effort. IO-Link is currently already supported by around 130 device manufacturers and companies in the field of technology. IO-Link Masters are offered by around 40 manufacturers and the standard is supported by nine manufacturers of control systems with central Masters and respective engineering tools. IO-Link devices are in the product range of almost sixty manufactur-

IO-Link system set-up ers of sensors, actuators and other peripherals. Rexroth, for example, now also offers hydraulic proportional valves and pressure sensors with respective technology. Function and performance of these proportional valves are identical to series valves. However, they also offer all options for bi-directional communication via IO-Link. This way, the hydraulics can be integrated seamlessly into connected structures. Parameters can be changed and operating states changed by the control system during running operation. A full IO-Link system consists of one centralized or decentralized IO-LINK Master, one or more IO-Link devices as well as unshielded 3 or 5-conductor standard cables with M12 connectors. Project planning and parameterization of the IO-Link Master can be realized in the control system hardware or an optional engineering tool. The point-to-point connections between IO devices and the automation system are established by the IO-Link Master. It serves as the interface to the superior control system. Open standards Industrial Ethernet IO-Link Master Field Bus IO-Link Master IO-Link Master Proportional Valve 4WRPEH Pressure Switch HEDE 10 IO-Link integrates hydraulic valves and sensors with analog control in any type of automation structures and establishes bi-directional digital communication.

IO-Link Masters are offered by around 50 manufacturers for connection of one IO device per port. The selection includes options for the IP20 control cabinet as well as decentralized modules with protection class IP65/67 for installation at machinery or systems. Particularly in large-scale systems, cabling is considerably reduced. For decentralized IO-Link Masters, the user organization of IO-Link has defined M12 plug-in connectors with three or five conductors. The 5-pole version "Class B" port is used for devices with increased current consumption like hydraulic valves. The 3-pole version "Class A" port provides an energy supply of up to 200 ma which is sufficient for most sensors. In contrast to analog controls, unshielded cables are sufficient for fault-free communication over a cable length of up to 20 meters. IO-Link standardizes connection technology for all actuators and sensors and eliminates numerous sources of errors during the installation of systems. Otherwise complicated and expensive cable dimensioning with individual wiring and shielding is no longer required. In addition, the logistic effort is reduced thanks to application of uniform M12 cables for sensors and actuators. Rapid commissioning per software Every IO-Link device features an electronic device description, referred to as IO Device Description (IODD). It provides standardized important information: Device data Text description Identification, process and diagnosis data Communication properties Device parameters with value range and default value. Image of the device Logo of the manufacturer The IODD set-up is identical for all devices of all manufacturers. The IODD enables automatic recognition of the device by the IO-Link Master for immediate parameterization. Also automatically, device descriptions are included in the system documentation. For project integration of the IO-Link Master in overall automation, commissioning personnel use the engineering tools of the respective PLC manufacturer. The IO-Link Master is selected from the device portfolio and added to overall automation. Depending on the control system manufacturer, all blocks for communication are available in a library for free. Type Data* Manufacturer Device Type Item Number Serial Number Instance Data* Location and Use Assignment (e. g. AKZ, OKZ) IO-Link is i4.0 ready! *Terms according to "Plattform Industrie 4.0" Source: Standardization Council i4.0 Ready for the future: IO-Link provides defined type and instance data and turns series valves into Industry 4.0 components.

Via IO-Link to Industry 4.0 IO-Link enables access to device data either directly from the control system or remotely via networks from any location. Particularly important for future-oriented concepts: Already today, IO-Link offers type and instance data of Industry 4.0 devices according to the definition of the German "Plattform Industrie 4.0" initiative. This way, also hydraulic actuators meet all conditions for future requirements of Industry 4.0 applications. Additionally, this approach is well-suited for subsequent connection of existing machinery and systems with low effort. Users replace installed proportional valves and sensors by interchangeable options with IO-Link connection for direct communication with actuators and sensors. Diagnosis functions for increased availability The diagnosis functions of IO-Link devices enable new maintenance concepts and considerably reduce repair times. Now possible call-up of device information in parallel to the process forms the basis for condition-oriented and predictive maintenance concepts In this respect, proportional valves report whether they are functional as well as errors like under or overvoltage and electronic temperatures exceeding the admissible value. In addition, the valve and sensor status is displayed for transparent error analysis. An integrated operating hour indicator enables calculation of the residual life cycle for maintenance and decision-making on further use of the valve. In case of faults, IO-Link accelerates diagnosis thanks to remote access for maintenance specialists to identify the type and location of any errors. Precise localization without personal presence at the system alone considerably reduces reaction times. If necessary, the maintenance technician opens the IODD file of the respective device in the control system. Other than before, components do not need to be disassembled to decipher hardly readable labels and manufacturers and types no longer need to be looked for in system documentations. Thanks to the electronic name plate, all this information can now be accessed with just one mouse click to initiate the respective order without delay. IO-Link follows the plug & play principle. Replaced devices are recognized by the IO-Link Master according to their IODD file and the respective parameters are automatically transferred without any actions in the software. This way, even less experienced technicians are enabled to replace components without problems to considerably reduce system downtimes. Summary The open IO-Link standard establishes continuous communication with sensors and actuators irrespective of the used field bus. Now, even hydraulic proportional valves can be intelligently, easily and cost-effectively integrated in bi-directional digital communication. This simplifies commissioning in hardware and software and enables flexible adjustment of hydraulic valves for varying production processes. Increased requirements for flexible machinery and systems are now complied with. Extended diagnosis information enables condition-oriented and predictive maintenance concepts and standstill and maintenance times are reduced. This increases the availability of machinery. In addition, IO-Link enables future-proof integration of hydraulic valves into connected structures as Industry 4.0 components with all their related features. Bosch Rexroth AG Bgm.-Dr.-Nebel-Str. 8 97816 Lohr am Main Theobald Herrmann Product Management Hydraulic Valves Bosch Rexroth AG