HOURLY ANALYSIS PROGRAM 5.10

Similar documents
HOURLY ANALYSIS PROGRAM v5.00 and v5.01

CARRIER HOURLY ANALYSIS PROGRAM v5.0

CARRIER edesign SUITE NEWS

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.90

NEW FEATURES IN CARRIER BUILDING SYSTEM OPTIMIZER 1.40

DEDICATED HEAT RECOVERY UNIT (DHRC)

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

Energy Engineering: Tools and Trends

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Building Re-Tuning (BRT) Lesson 4: SOI Air-Handling Unit Part II

TRACE 700 Learning Series Module 2: Navigation

What s on the Horizon for HVAC in Title ? Mark Hydeman, PE, Principal Taylor Engineering, LLC

TRACE 3D Plus Getting Started - Load Design and Energy and Economics Examples L E T S G O B E YO N D. Trane.com/TRACE3DPlus

New Wisconsin Energy Code: What it Means for Me?

IT Air Conditioning Units

Energy modeling of two office buildings with data center for green building design

DUKE UNIVERSITY DESIGN & CONSTRUCTION STANDARDS

Cooling season full and part load performance evaluation of Variable Refrigerant Flow (VRF) system using an occupancy simulated research building

Commercial HVAC and Other Measures for 7P. Outline

Energy-efficient heating, ventilation and air-conditioning Technologies for certified buildings

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

IESVE Revit Plug-in User Guide <VE> 6.1

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

MECHANICAL CALCULATIONS USING REVIT

ASHRAE elearning Course Catalog

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Validation and Uncertainty Characterization for Energy Simulation

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Carrier Electronic Catalog Customer Suite Version Release Sheet

Sir Walter Scott may not have been thinking of building automation systems. How BACnet. Is Connecting At ASHRAE s Headquarters

equest Training equest Schematic Design Wizard

Customer Suite Version Release Sheet

Variable Speed IPLV.36 kw/tr

Evaluation and Modeling of Data Center Energy Efficiency Measures for an Existing Office Building

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

SE7600E Series Application Guide

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

Integrated Environmental Solutions Virtual Environment Release Notes

ORNL Flexible Research Platforms

DUCTED SPLIT SYSTEMS With Scroll compressors

Building Loads and Dedicated Outdoor Air Systems

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Efficiency of Data Center cooling

MSYS 4480 AC Systems Winter 2015

Copyright Executive Summary

ASHNuN. Fundamentals of HVAC Control Systems. Robert McDowell and Ross Montgomery are the authors of the

VARIABLE REFRIGERANT FLOW SYSTEMS HITACHI SMARTFLEX VRF GEN II FLEXIBILITY, PERFORMANCE AND CONTROL

SECTION GRAPHICS

The challenge is that BAS are often very complex with 1000s of data points to review. EMS Optimization Software

Samuel Tepp Engineering Seminar Topics

Modbus RTU/TCP GOLD RX/PX/CX/SD, GENERATION C/D Applicable to program version 1.05 and newer versions

Installation and Operation Instructions

ASHRAE IRELAND HVAC FOR DATA CENTRES. Michael Geraghty Building Services Engineer (DipEng) Company owner and managing director

Better Building Controls Through Simulation

Advanced Rooftop Controller

Control Strategies Affected by Changes in IECC-2012

Trane mytest Water-cooled Chiller Performance Validation What you spec is what you get *

ASHRAE Standard 90.1

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

Introduction. To use Carrier wireless sensors, you must have: A i-vu v6.5 or later system v6-00 or later drivers

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Webselect VAV Selection/Pricing Quick Start User Guide for Manufacturer Rep Users

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

MEASURE MONITOR UNDERSTAND

interactive tool for 90.1 available on the ASHRAE website.

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management

CenterPoint Energy Retro-Commissioning Program Application

CGAM air-cooled scroll chiller. Highly efficient, yet extremely quiet

Airside Economizer Comparing Different Control Strategies and Common Misconceptions

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Trailblazer AGZ-E air-cooled scroll chillers

Reducing Energy Consumption with

Saving Energy with Free Cooling and How Well It Works

High Efficient Data Center Cooling

Scalable, Secure. Jason Rylands

Data Center Energy Savings By the numbers

TRACE 700. Slide 1. Today, we will be talking about Airside Economizers in TRACE 700. Slide 2

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

Ecoflair Air Economizers

Data Center Trends and Challenges

Data Center Energy and Cost Saving Evaluation

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

Rooftop Unit Optimization Offering Frequently Asked Questions and Updates Released April 1, 2013

Energy Management of the Refrigeration Systems at Zurich Airport. Burkhard Bein. Schaffhausen,

Introducing the Heat Wheel to the Data Center

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Training courses 2018

Data Center Temperature Rise During a Cooling System Outage

Building Management System Application Datasheet

Driving Proactive Facility Operations with Automated HVAC Diagnostics

Airside Economizer Comparing Different Control Strategies and Common Misconceptions

Indirect Adiabatic and Evaporative Data Centre Cooling

TOSHIBA DesignAIRS. Help & Guide Manual

MOLLIER DIAGRAM CAN BE IMPROVED!

Indirect Adiabatic and Evaporative Data Center Cooling

What s New for Data Centers in Title Jeff Stein, PE Taylor Engineering

ecoenergy Innovation Initiative Research and Development Component Public Report

Customer Suite Version Release Sheet

Transcription:

HOURLY ANALYSIS PROGRAM Carrier Software Systems Carrier Corporation Syracuse, New York Rev. August 21, 2017 Copyright 2017 Carrier Corporation

Contents LEED v4 ASHRAE Standards Updates Modeling Capabilities Productivity Enhancements 2

LEED V4 3

LEED v4 Compliance Details: LEED v4 options have been added to projects. 4

LEED v4 Compliance The LEED v4 report mimics the format & inputs of the LEED Minimum Energy Performance Calculator to speed up data entry. Report includes the project s EA credit points score, supporting multiple ratings systems. 5

LEED 2009 Updates The LEED 2009 report has also been updated to match the latest LEED spreadsheet. 6

ASHRAE STANDARDS UPDATES 7

Support for ASHRAE Standard 90.1-2013 Details: 90.1-2013 has been added as a project energy standard option. Using the "ASHRAE Minimum Efficiency" options for equipment, will derive efficiency using 90.1-2013 tables. Now including VRF equipment. 8

Support for ASHRAE Standard 90.1-2013 Details: Templates for 90.1-2013 baseline systems, construction assemblies, and schedules are included with. Load the project archive 51_ASHRAE-90.1-2013_Library_1.0.E3A to get started with 90.1 templates. Updated templates for 90.1-2007 and 90.1-2010 are also included in separate archives. 9

Support for ASHRAE Standard 62.1-2016 Details: ASHRAE Standard 62.1-2016 was added as a project ventilation standard option. When selected, ventilation requirements can be selected from -2016 space usage types in space inputs. System inputs offer an option to calculate system ventilation requirements using the 62.1-2016 Ventilation Rate Procedure. 10

MODELING CAPABILITIES 11

Zone Air Distribution Effectiveness Details: Zone Air Distribution Effectiveness (EZ) can be calculated automatically for a 62.1 ventilation analysis. Alternatively, EZ can be directly specified. 12

Design Supply Temp. for Reheat Terminals Details: Improved reheat coil capacity sizing calculations are now temperature based. Capacity is derived from coil flow, inlet temperature and the specified reheat coil design heating supply temperature. Applies to terminals for: VAV reheat, Single zone constant volume, Constant volume terminal reheat, Dual or triple duct constant volume, Series fan powered mixing boxes, and Parallel fan powered mixing boxes 13

PRODUCTIVITY ENHANCEMENTS 14

New VRF Outdoor Unit Sizing Data Details: The Zone Sizing Summary report for Variable Refrigerant Flow (VRF) systems now includes a sizing table for the VRF outdoor unit (ODU). This lists the peak coincident load for all indoor units, an estimate of pipe losses, and the total capacity requirement for the ODU. 15

Updated EIA Electric and Gas Prices for the US Details: Energy Information Administration (EIA) prices for electricity and natural gas includes the latest data (2015 calendar year). Statewide average commercial sector prices are provided for each US state. 16

Summary of Project Settings Details: The main window the status bar now displays the current project settings for LEED rating method, energy standard, and ventilation standard. 17

Other Enhancements a. Air System Design Reports Added a CFM/ton check figure to the central cooling coil section of the Air System Sizing Summary report. b. Air System Design Reports Added a System Psychrometrics graph for design heating condition. When the graph is selected for the peak time, will generate psychrometric process graphs both for the design cooling and design heating conditions. c. Air System Simulation Reports Modified the Zone Temperature Report for the special case where a system has zero occupied period operating hours for the year (i.e., all hours are in the unoccupied period). In this case the report shows maximum and minimum occupied temperatures as na. d. LEED Reports - The Baseline Performance Performance Rating Method Compliance table now displays process energy cost as a percentage of total baseline energy cost with 1 decimal place rather than as a whole number (e.g. 24.6% rather than 25%). This helps in clarifying compliance with the 25% minimum rule. This change was made both in the LEED v4 Optimize Energy Performance Summary report and the LEED 2009 EA Credit 1 Summary report. e. Spaces - Increased the maximum limit for electric equipment heat gain from 99 W/sqft (1065 W/sqm) to 1000 W/sqft (10763 W/sqm). f. Plants - Increased the maximum size for service hot water storage tanks from 1500 gal (5678 L) to 99999 gal (378537 L). g. Chillers - Reduced minimum chiller EWCT limit from 45 F (7.2 C) to 35 F (1.7 C). 18

Bugs / Corrections a. Air System Design Reports The System Psychrometrics report incorrectly displayed preheat coil airflow. (This was only a display error. correctly calculated coil airflow and coil load.) b. Air System Design Calculations A Subscript out of range error occurred when performing design calculations for a system using ASHRAE Std. 62.1 ventilation sizing. This could occur when the volume of a space was unusually large. c. Air System Input Report The estimated maximum load shown for a VRF outdoor unit (ODU) was incorrect. (This was only a display problem. correctly calculated the estimated maximum load and the ODU cooling and heating capacities.) d. Air System Inputs When defining a Split DX Fan Coil terminal system, the Terminal Cooling equipment input screen incorrectly labeled the equipment performance input as Compressor kw rather than Compressor + Outdoor Fan kw. e. Plant Simulation In a Dedicated Heat Recovery Chiller (DHRC) heat recovery plant with multiple cooling-only chillers, in certain off-design situations the plant operated with an extra cooling-only chiller running. f. Weather Data When importing a simulation weather file, an error occurred if the file used the TMY2, TMY3, ASHRAE IWEC or IWEC2 formats. The error did not occur when importing a file with the EnergyPlus EPW format. g. Space Inputs If a space without exterior walls had been modified via the global change feature to apply a CFM/sqft (L/s/sqm) infiltration value, it could later show a "validation error" message, but no input items were highlighted as invalid. h. Equipment Wizard If a VRF system was defined without a DOAS the options for Demand Controlled Ventilation and Ventilation Reclaim were shown but were invalid for a terminal system using direct ventilation. i. Project Management In some cases data files containing deleted items were not removed from a project. This resulted in greater disk space usage than necessary. 19

QUESTIONS? If you have any questions please contact Carrier Software Systems at software.systems@carrier.utc.com Thank you! 20