Cluster FX-Bar. Portable performance lighting and laser rig

Similar documents
Kam StarWash Multicolour wash effects with green & red star cluster laser

PowerGlide Multicolour sweeping beam effects

Star Cluster 300 RGB

LASERSCAN 1000/1200RGB

LASERSCAN D M A N U A L V E R S I O N / 0 4 / 1 2

Microbar Multi System

3D OBJECTS RGB LASER. Order ref: UK User Manual

Blitzer Strobe. User Manual. Order code: EQLED366

Spectrum Laser. User manual UK. Version 1.0

OPERATION MANUAL FEATURES BEFORE USE SAFETY INSTRUCTIONS: JB SYSTEMS 1/6 COLOR JET

Flat Par 9 LEDs. battery power, Wirelss, Remote Control, RGBWA-UV 6-in-1 USER MANUAL. Please read over this manual before operating the light

LED SPIDER MOVING HEAD LIGHT

Blitzer RGB Strobe. User Manual. Order code: EQLED365

LED Slimline PAR RGBW 7x8W

DDS 405 digital dimmer and switcher. user manual

LED W RGBA User Manual

12X3W UV LEDS PROJECTOR LED- 12 USER GUIDE

Blue Weapon Laser. User manual UK. Version 1.0

Microbar COB System. User Manual. Order code: EQLED137

RGB Power Batten. User Manual. Order code: EQLED032

Gobo Projector XP 80W

Crossfire. User Manual. Order code: EQLED061

LED Giga Bar 4. User Manual

ALO Duo Roll DMX LED barrel scanner with dual light source

Robot Light V2. User Manual

xbrick Full-Colour 16 3W LED floodlight user manual

APT20. User Manual.

TourPro RGBAW Stagebar USER MANUAL

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

SUBWOOFER SYSTEM YST-MSW10

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

LED DANCING FLOOR User Manual

UV Power Flood. User Manual. Order code: EQLED029

TECHCONNECT TC2-HDMI14 OWNERS MANUAL

UV Spectra Batten 12 x 5W UV LEDs

GLX LED STAGE 4 MANUAL GLS-4 LED STAGE 4. owners manual

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

1 Channel Strobe Controller ORDERCODE 40226

DPX-620III 6-Ch. dimmer pack. user manual

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

DUAL LASER PACK & CONTROLLER USERS MANUAL

KCD3000 USB. Professional anti-shock twin CD/USB player 16 / 09 / 10

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

PORTABLE SPEAKER & AMPLIFIER USER MANUAL

PRE116/126. User Manual.

RGBW PAR CANS. Item ref: SL-FC3, SL-36, SL-64, SL-SW, SL-Q8, SL-Q12 User Manual. Errors and omissions excepted. Copyright AVSL Group Ltd.

DDS-405 LC DMX 4 Ch. Dimmer dimmer pack. user manual

CS2 DMX Distribution Splitter

Eternal Lighting. Premier150 Spot. User Manual

DMX Tool Splitter 1 to 5 User Manual

MICRON DJ Booth Tri-colour Starcloth

Beam Stage Light (RGBW)

5 B&W Rear View System Camera

D1210H dimmer pack. user manual

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

UP-1-1 Channel Dimmer. User manual. dimmer pack

TPC25 active crossover. user manual

AV-1600 DIGITAL AMPLIFIER OWNERS MANUAL

LED Pixel Rail Drive 640 controller. user manual

Octostrip ORDERCODE 42220

Network Camera. Quick Guide DC-B1203X. Powered by

FUSION SPOT MKII EQUINOX. Contents. User Manual. Order codes: Black housing - EQLED Safety Instructions. 2. Features & Specifications

SAFETY WARNINGS AND GUIDELINES

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

Hypnos. User Manual. Order code: EQLED372

DMX LED Starcloth Systems

UP-1-1 Channel Dimmer dimmer pack. user manual

Revo 120. User Manual

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

STAGE-PAR CX-2 RGBAW LED PAR. user manual

PAR56 10MM UV LED PAR. user manual

Fusion Saber. User Manual. Order code: EQLED070

CDP 405 Digital Dimmer Pack

DMX Splitter 4 MKIII 19" DMX splitter. user manual

w w w. p r o l i g h t. c o. u k STAGE PAR 64

Slimline CW & WW Series

Outdoor Stage PAR 12 3W Tri LED-PAR. user manual

LED Derby ST. User manual. LED effect

LED Par 64 Short DMX ORDERCODE 42431

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

Owner s Manual. DJ Lase 150-RGY MKII

LIGHT BRICK - 12 X 3W TRI-COLOUR

MONOPRICE. ShowPony 12-Watt LED Derby FX Light (RGBW) User's Manual P/N

MODEL 805 USER MANUAL

DS-2 RF DMX dimmer. user manual

N-E Color Par 64 USER MANUAL

User s manual. Giga Bar II

SP-1800 OWNERS MANUAL

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

LED Commander 16/2 DMX controller. user manual

Flexoled FTP3HP RGB LED DMX Driver

RevueLED 150 Profile 3200K 26 LED spotlight. user manual

SP-1400P POWERED SPEAKERS OWNERS MANUAL

MATRIX LED LED User Manual Please read the instructions carefully before use

7x15W 4IN1 Infinity Rotation LED Pixel Bar. This product manual contains important information about the safe

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

INSTALLATION MANUAL. HDMI 1x8 Splitter B-230-HDSPLTR-1x8 B-230-HDSPLTR-1X8

TECHCONNECT TC2-HDMI41 OWNERS MANUAL

Performer 18 RGBWA MKII

Transcription:

Cluster FX-Bar Portable performance lighting and laser rig Due to continuous product development, please ensure that you have downloaded the latest instruction manual for this product from the AVSL website at www.avsl.com For the latest instruction manual updates and information on the entire range visit: www.avsl.com

Thank you for purchasing this product, we are sure that it will serve you for many years to come. To optimise it s performance, please read these instructions carefully to familiarise yourself with the basic operations of the unit. Please retain them for future reference.this unit has been tested at the factory before being shipped to you. To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture. To prevent a fire hazard, do not expose the unit to any naked flame sources. Unplug this apparatus during lightning storms or if it is unlikely to be used for long periods of time. When installing the unit, please ensure you leave enough space around the unit for ventilation. Slots and openings in the unit are provided for ventilation to ensure reliable operation of the product and to protect it from overheating. To prevent fire hazard, the openings should never be blocked or covered. The unit is powered by the mains, always handle the power cable by the plug. Never pull out the plug by pulling on the cable. Never touch the power cable when your hands are wet as this could cause an electric shock. Do not tie a knot in the cable. The power cable should be placed such that it is not likely to be stepped on. A damaged power cable can cause a fire or give you an electrical shock. Check the power cord periodicaly, if you ever find that it is damaged, replace it before using the unit again. Contact your retailer for a replacement. The voltage of the available power supply differs according to country or region. Be sure that the power supply voltage of the area where this unit is to be used meets the requirements of the unit. The lightning flash symbol inside a triangle is to alert the user to the presence high voltage within the unit s enclosure that may be of sufficient power to constitute a risk of electrical shock to persons. Caution: to prevent the risk of electric shock, do not attempt to open the unit. No user-serviceable parts inside. Refer all servicing to qualified service personnel. The exclamation mark inside a triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the appliance. Please read and pay attention to all laser safety warning sticker labels on the unit. Select the installation location of your unit carefully. Avoid placing it in direct sunlight or locations subject to vibration and excessive dust. Do not use the unit where there are extremes in temperature (below 41ºF / 5ºC or exceeding 95ºF / 35ºC). Unpacking and safety Please unpack your new product carefully. Your new product should reach you in perfect condition. Please check that no damage has occurred during transit. If any damage is found, do not operate your unit. Please contact the retailer you purchased it from immediately. If there is any damage to the mains cable do not use the device. Always disconnect the unit from the mains supply when carrying out any cleaning of the unit. Manufacturer declarations In compliance with the following requirements: RoHS Directive (2002/95/EU) and WEEE Directive (2002/96/EU). If this product is ever no longer functional please take it to a recycling plant for environmentally friendly disposal. CE declaration of conformity R&TTE Directive (1999/5/EU), EMC Directive (2004/108/EU), Low Voltage Directive (2006/95/EU). Before putting the devices into operation, please observe the respective country-specific regulations. This manual contains important laser system safety and operation information. Read and understand all instructions prior to powering on the laser unit the first time to avoid eye injury and to avoid breaking the law. Keep this manual in a safe place for future reference. Lasers can be hazardous and have unique safety considerations. Permanent eye injury and blindness is possible if lasers are used incorrectly. Pay close attention to each safety WARNING statement in this manual.

Laser safety warnings Potential laser injury hazard exists with this product! Please read these instructions carefully, which include important information about installation, safe use and service! Caution Avoid direct eye contact with laser light. Never intentionally expose your eyes or others to direct laser radiation. Caution It is illegal and dangerous to shine any laser at aircraft. Caution Operating procedures other than those specified herein may result in hazardous radiation exposure. Overhead rigging Important - the installation must be carried out by qualified service personal only. Improper installation can result in serious injuries and /or damage to property. Overhead rigging required extensive experience. Working load limits should be respected, certified installation materials should be used, the installed unit should be inspected regularly for safety. l Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing. l Locate the unit in a well ventilated spot, far away from any flammable materials and/or liquids. The fixture must be fixed at least 50cm from surrounding walls l The device should be installed out of reach of people and outside of areas where persons may walk by or be seated. l Before rigging make sure that the installation area can hold minimum point load of 10 times the device`s weight. l The device should be well fixed; a free swinging mounting is dangerous. l Do not cover any ventilation opening as this may result in overheating Before first time use, the unit should be inspected for safety. Inspection the unit regularly every year. AC power The unit is supplied with a power plug appropriate to its voltage. Should any other connections be required they must be carried out with the following configuration: Cable (EU) Cable (US) Pin International Brown Black Live L Light blue White Neutral N Yellow/green Green Earth DMX-512 connection If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the first unit in a DMX chain. If you wish to connect a DMX controller with other XLR outputs you will need to use adapter cables. 1 = Shield DMX output 2 = Signal (-) DMX input 3 = Signal (+) Connect the DMX output of the first unit in a DMX chain with the DMX input of the next unit in the chain. Always connect the the output of one unit with the input of the next unit until all units are connected.

Unit features & functions Number Feature Function 1 Power supply input Attach the IEC mains cable here. Built-in fuse. 2 DMX input 3 pin XLR connector for DMX512 input communication. 3 DMX output 3 pin XLR connector for DMX512 output communication. 4 LED display LED function display and menu buttons to control the operating mode of the unit. 5 MENU buttons MENU function buttons x 4 (see below for operation). 6 Mic Built-in microphone for Sound-to-Light operation. 7 Par can mounts Attach the par can lights to the controller bar at the 2 points shown. 8 Lighting unit connections Attach all 4 lighting cables to the controller bar at the points shown. 9 Laser mounts Attach the lasers to the controller bar at the 2 points shown. 10 Light stand socket Tighten screw to secure the controller bar to the light stand. Function setting Using the four function buttons on the controller bar you can set the operating mode of the unit. Press the Menu button to display the different functions (see table below for a description of the functions). Use the Up or Down arrow buttons to make your selection. When you have chosen your desired function, press the Enter button to confirm the change. Auto modes: AP (parcan effects) / AF (laser effects) / AN (parcan and laser effects) Sound to Light modes: SP (parcan effects) / SF (laser effects) / SN (parcan and laser effects) Display Mode Function AUT SOU COL dnh (DMX) AUTP par can auto mode AP01-AP13 auto shows S01-S32 par can speed AUTF laser auto mode AF01-AF07 auto shows S01-S32 laser speed N00-N09 motor speed setting AUTN unit auto mode AN01-AN10 auto shows S01-S32 lighting speed N00-N09 motor speed setting SOUP par can sound mode SOUF laser sound mode SOUN unit sound mode COLO D001-D510 SP01-SP13 sound shows SF01-SF07 sound shows SN01-SN10 sound shows R 0-255 red adjust G 0-255 green adjust B 0-255 blue adjust U 0-255 white adjust S00-32 strobe adjust N00-09 motor speed adjust 3CH 3 channel DMX mode 7CH 7 channel DMX mode 11CH 11 channel DMX mode SLA SLAU Master/Slave mode SYS ASEN SN01-SN04 mic sensitivity

DMX address setting When controlling the unit (or units) with a DMX controller, each one must be set with a specific DMX address. You can choose to set all units with the same DMX address or you can set every unit with its own DMX address. If all units are set with the same DMX address all units will be synchronised and operate in the same way. If you set each unit with a different DMX address, they will receive the DMX signal from their own DMX address. You will now be able to control each unit individually. The DMX address that you set for each unit must be determined by the number of channels. This unit has different options of DMX channel modes (3, 7 or 11). When working in 3 DMX channel mode, you should set the starting address of the first unit to 1, the second unit must be set to 4 (1+3), the third to 7 (4+3), the fourth to 10 (7+3) and so on. When working in 7 channel mode, you should set the starting address of the first unit to 1, the second unit must be set to 8 (1+7), the third to 15 (8+7), the fourth to 22 (15+7) and so on. When working in 11 channel mode, you should set the starting address of the first unit to 1, the second unit must be set to 12 (1+11), the third to 23 (12+11), the fourth to 34 (23+11) and so on. 3 channel DMX mode NB The DMX settings in Channel 2, relate to the 6 settings in Channel 1 (AP, AF, AN, SP, SF, SN) Channel 1 2 ANxx/SNxx Value 0-9 Black out 10-49 APxx 50-89 AFxx 90-129 ANxx 130-169 SPxx 170-209 SFxx 210-255 SNxx 0-19 Auto Program 1 20-39 Auto Program 2 40-59 Auto Program 3 60-79 Auto Program 4 80-99 Auto Program 5 100-119 Auto Program 6 120-139 Auto Program 7 140-159 Auto Program 8 160-179 Auto Program 9 180-255 Auto Program 10 3 Speed adjust 0-255 7 channel DMX mode Channel Value Function 1 0-255 Red 2 0-255 Green 3 0-255 Blue 4 0-255 White 5 0-255 Strobe 6 0-255 Motor 0-9 NO 7 10-99 Red laser 100-199 Green laser 200-255 Red and green laser

11 channel DMX mode Channel Value 1 0-255 Red 2 0-255 Green 3 0-255 Motor 4 0-255 Red 5 0-255 Green 6 0-255 Blue 7 0-255 White 8 0-255 Red 9 0-255 Green 10 0-255 Motor 11 0-255 Strobe Laser Par cans Laser Remote control operation ON/OFF button turn the unit on or off DMX button set the unit to DMX mode Laser ON/OFF button turn the lasers on or off AUTO MIX button set the unit to Auto mode with par cans and lasers LED button set the unit to Auto mode with par cans LASER button set the unit to Auto mode with lasers SOUND MIX button set the unit to Sound mode with par cans and lasers LED button set the unit to Sound mode with par cans LASER button set the unit to Sound mode with lasers R button turn the red laser diode on G button turn the green laser diode on R G button turn the red and green laser diodes on - COLOR + buttons > adjust the par can colour/speed (- slower / + faster) - MOTOR + buttons + adjust the laser motor speed (- slower / + faster) - SEN + buttons adjust the sensitivity of the Sound mode (- less senstitive / + more sensitive) Product specification Mains power / rated power AC 220~240V, 50/60Hz / 60w Control modes 3/7/11 channel DMX512 / Auto / Sound-to-Light / Master/Slave / Remote control Light source 2 x par cans with 12 x 1w RGBW LEDs plus 2 x lasers with 120 mw red + 50mW green diodes Operating temperature -20 C to 40 C Laser safety class 3R DMX512 connections 3 pins XLR male/female Dimensions (WxDxH) 725 x 200 x 150mm (not including stand) Weight 5.8Kg Due to continuous product development, specifications and appearance are subject to change.