Tongue Switches Visit our website: Interlock. Switches. Safety Switches. Trojan 5 & 6. Specifications.

Similar documents
3-14. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Tongue Switches Cadet 3.

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs Safety Contacts Direct Opening Action. Operating Radius, Min

Tongue Switches Trojan 5 & 6

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs Safety Contacts Direct Opening Action. Operating Radius, Min

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts. Auxiliary Contacts

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Auxiliary Contacts

Safety Switches 3-1. General. 3-Interlock. Switches. Operator. Interface. Logic. Power. Safety Switches Table of Contents. 2-Opto-electronics

SensaGuard. Description. Features. Benefits. Specifications

Standard actuator 440K-A Standard actuator 440G-A Fully flex actuator 440G-A07269

Specifications. Functional Safety Data Note: For up-to-date information, visit Certifications.

Non-contact Machine Safeguarding with RFID Technology. LED offers diagnostics for switch status, margin alignment, and fault finding

Safety Interlock Switches

MSR42 Micro 400 Controller/Muting Module

3-6. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Interlock Switches Overview.

3-56. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Non-Contact Switches SensaGuard

3-6. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Interlock Switches Overview.

SafeC S to MSR127 Conversion

4-20 Visit our website: Emergency Stop. Devices. Stop Devices. 4-Emergency. Operator Interface Enabling Switches Overview

Magnetically Actuated Safety Interlock Switches

MSR178DP. Description. Features. Specifications

Safety Light Curtains GuardShield Remote Teach

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Inputs. Switching Voltage, Min. Conductor Size, Max.

Universal Tongue-Operated Safety Interlock Switch

Versatile Safety Interlock Switch with Guard Door Locking

Safety Systems Safety Integrated

Datasheet - RSS 36-D-R-ST

Bul. 440R Guardmaster Safety Relays (DI, DIS, SI, CI, EM, and EMD) Selection Guide

Magnetically Actuated Safety Interlock Switches

Presence Sensing Safety Devices

Compact Coded Magnetic Safety Interlock Switch and Control Units

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Bulletin 440R 440R 440R-S

Compact Magnetic Non-contact Safety Switches. Model Number Structure

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

Datasheet - AZ 16-02ZVK

SR B series coded magnetic safety sensors

Datasheet - AZ 16-03ZVRK

Datasheet - AZ 16-02ZVRK-ST

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Datasheet - AZ 16ZVRK

Datasheet - AZ 15 ZVRK

Safety Products Core Products Document

Datasheet - AZ 15 ZVK

Safety switches with separate actuator

Datasheet - AZ 15 ZVRK

Datasheet - AZ 15 ZVRK

Datasheet - AZ 15 ZVRK

Magnetically Coded Non Contact Switch (MC2) Installation Instructions

Datasheet - AZM300Z-ST-1P2P-A

Safety switches for hinged doors

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R

Datasheet - ZS Z

Magnetic Non-contact Safety Switches. Model Number Structure

Safety switches with separate actuator

SensaGuard 18 mm Barrels

Safety switches with separate actuator

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

SR A series coded magnetic safety sensor

Safety coded magnetic sensor SR A series

Datasheet - ZR Z

Bulletin 871L & 872L Limit Switch Style

Bulletin 440, 442, 802 Safety Product Overview

Coded magnetic safety sensor SR B series

Safety switches with manual mechanical delay and separate actuator

24 VDC or 24 VAC/DC or 110 VAC or 220 VAC NOTE: 220 VAC not available for S2 and S3 configurations. EN1088, EN , EN292, EN

Safety Switches CES-AR/CET-AR

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Limit switches 3. with solenoid interlocking. Metal, type XCSE and XCSL. Page 6/284. Page 6/296

Safety coded magnetic sensor SR B series

SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK

the Interactive Catalog

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Datasheet - MZM 100 B ST-1P2PW2REM-A

Compact Magnetic Non-contact Safety Switches. Model Number Structure

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Datasheet AZM 161 Z ST1 AS RA

Bulletin 700-HL 2-Pole Terminal Block Relay

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Copyright 2011 Rockwell Automation, Inc. All rights reserved. Next Generation Guardmaster Safety Relay Platform Overview

Safety Monitoring Relays

Datasheet SRB301ST 24V (V.2)

Magnetically Coded Safety Switches CMS

Pile Driver Weld Immune Sensors

Guardmaster Safety Relays DI, DIS, SI, CI, GLP, EM, And EMD

Specifications. Description. Degree of Protection. Input Voltage (Relay type) Input Voltage (Solid-State type) Electrical Design Life (Relay type)

Datasheet - SRB 301LC/B-24V

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

SERIES AZ15/16. Tamper-Resistant Movable Machine Guard Safety Interlock Switch. Features & Benefits. Description. Operation. Typical Applications

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Safety Products Introduction LS-Titan Safety Interlock Switches. Technical Reference... 2

SMARTSCAN INFORMATION

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Bulletin 871D Cylinder Position Inductive Style

Safety coded magnetic sensor SR A series

Transcription:

1-2 -Interlock Safety 4 Description The Trojan family is a universal tongue-operated (or key-operated) safety-interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards. The dual key entry slots and rotatable head, movable only by releasing the cover screws, allow four actuator entry options. The Trojan contains all of the safety related functions i.e., forced guided contacts, tamper resistant mechanism allowing the machine to be safeguarded in compliance with the machine directive. Operation of the switch is achieved through the insertion of a specially-profiled stainless-steel key that is permanently mounted to the leading edge of the guard door. The standard (not GD2) Trojan actuator includes a self-ejecting mechanism that prevents operation of the switch if the actuator is not mounted to the guard door (e.g., if the operator uses a spare key). Features Strong and versatile, can be used in most applications Self-ejecting tamper resistant actuator, only operates when mounted to the guard (not with GD2 models) Four possible actuator entry points, easy to install GD2 style available for demanding applications Specifications Safety Ratings EN 94-1, ISO 1849-1, IEC/EN 60204- Standards 1, NFPA 79, EN 1088, ISO 14119, IEC/EN 60947--1, ANSI B11.19, AS 4024.1 Cat. 1 device per EN 94-1 dualchannel interlocks suitable for Cat. or Safety Classification 4 systems B10d: 2 x 106 operations at min. load PFHD: > x10-7 MTTFd: > 8 years Functional Safety Data Dual channel interlock may be suitable Note: For up-to-date information, for performance levels Ple or Pld visit http://www.ab.com/safety/ (according to ISO 1849-1:2006) and for use in SIL2 or SIL systems (according to IEC 62061) depending on application characteristics Certifications CE marked for all applicable directives, culus, TÜV, and CCC Outputs Safety Contacts Direct Opening Action N.C. 2 N.C. 2 N.C. Auxiliary Contacts 1 N.O. 2 N.O. 1 N.O. Thermal CurrentIlth 10 A Rated Insulation Voltage (Ui) 00V Switching Current @ Voltage, Min. ma @ V DC Utilization Category Trojan A00/AC-1 (Ue) 240V 120V (le) A 6 A P00/DC-1 (Ue) 20V 24V (le) 0. A 2 A Trojan 6 A600/AC-1 (Ue) 600V 00V 240V 120V (le) 1.2 A 1.4 A A 6 A N600/DC-1 (Ue) 600V 00V 12V 24V (le) 0.4 A 0. A 2.2 A 2 A Operating Characteristics Trojan : 12 N (2.7 lb) and 0 N Break Contact Force, Min. (6.7 lb) Trojan 6: 20 N (4. lb) Actuation Speed, Max. 160 mm (6.29 in) per sec Actuation Frequency, Max. 2 cycle per sec Operating Radius, Min 17 mm (6.89 in) (60 mm) (2.6 in) with flexible actuator) Operating Life @ 100 ma load 1 x 106 operations Environmental Enclosure Type Rating IP 67 Operating Temperature C (F) -20 +80 (-4 +176 ) Physical Characteristics Housing Material UL approved glass-filled PBT Actuator Material Stainless Steel Weight g (lbs) 160 (0.) Color Red Usable for ISO 1849-1:2006 and IEC 62061. Data other than B10d is based on: - Usage rate of 1op/10 mins., 24 hrs/day, 60 days/year, representing 1840 operations per year - Mission time/proof test interval of 8 years The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. -22 Visit our website: www.ab.com/catalogs

Product Selection Type Trojan 6 Trojan 6 GD2 Safety Cat. No. Contact M20 Conduit Connector Connect to Connect to ArmorBlock 1/2 inch NPT Distribution Box Guard I/O Type Safety Auxiliary Action Actuator Type M20 Adaptor 6-Pin Micro (M12) -Pin Micro (M12) Standard 440K-T11090 440K-T11202 440K-T1120 BBM Flex 440K-T11110 440K-T1120 440K-T11206 Flex 440K-T11467 440K-T11204 440K-T11207 440K-T2NNBPS 440K-T11089 440K-T11129 Trojan BBM Standard Gold Standard 440K-T1108 Contacts Standard 440K-T11118 440K-T11208 440K-T11224 MBB Flex 440K-T1112 440K-T11209 440K-T116 Flex 440K-T11468 440K-T11210 440K-T1164 2 N.C. 1 N.O. 440K-T11146 440K-T11469 440K-T116 GD2 Standard 440K-T116 440K-T11211 440K-T1166 440K-T2NNGPS-NG BBM Flex 440K-T117 440K-T11212 440K-T1167 Flex 440K-T118 440K-T1121 440K-T1168 Trojan GD2 440K-T11147 440K-T11226 GD2 Standard 440K-T119 440K-T11470 440K-T1169 MBB Flex 440K-T1140 440K-T11471 440K-T1170 Flex 440K-T1141 440K-T11472 440K-T1171 440K-T11167 440K-T1172 Trojan 0 N BBM Standard 440K-T11 440K-T91024 440K-T11492 For connector ratings see page -9. With a -pin micro (M12) connector, not all contacts are connected. See Typical Wiring Diagram on page -27 for wiring details. Cat. No. Contact M20 Conduit Connector Safety Auxiliary Action Actuator Type M20 1/2 inch NPT Adaptor 8-Pin Micro (M12) N.C. 1 N.O. BBM Standard 440K-T11171 440K-T114 440K-T11449 440K-T11408 2 N.C. 2 N.O. BBM Standard 440K-T11174 440K-T1148 440K-T1142 440K-T11416 440K-W21BNPH MBB 440K-T114 440K-T1144 440K-W21MNPH N.C. 1 N.O. BBM GD2 Standard 440K-T11418 440K-T11466 440K-T11188 440K-T11444 MBB 440K-T1146 440K-T1147 2 N.C. 2 N.O. BBM GD2 Standard 440K-T1144 440K-T1142 440K-T1149 440K-T114 440K-W21BNPH-NG MBB 440K-T11460 440K-T11461 440K-W21MNPH-NG For connector ratings see page -9. With an 8-pin micro (M12) connector, not all contacts are connected. See Typical Wiring Diagram on page -27 for wiring details. 1-2 -Interlock 4 Visit our website: www.ab.com/catalogs -2

1-2 -Interlock Safety Recommended Logic Interfaces Description Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. Page No. Cat. No. Single-Function Safety Relays MSR127RP N.O. 1 N.C. Removable (Screw) Monitored Manual 24V AC/DC -24 440R-N21 MSR127TP N.O. 1 N.C. Removable (Screw) Auto./Manual 24V AC/DC -24 440R-N212 MSR126T 2 N.O. None Fixed Auto./Manual 24V AC/DC -22 440R-N2117 MSR0RT 2 N.O. Solid State 1 N.O. Solid State Removable Auto./Manual or Monitored Manual 24V DC -16 440R-N2198 Modular Safety Relays MSR210P Base 2 N.C. only 2 N.O. 1 N.C. and 2 PNP Solid State Removable Auto./Manual or 24V DC from the Monitored Manual base unit -74 440R-H2176 MSR220P Input Module Removable 24V DC -78 440R-H2178 MSR10P Base MSR00 Series Output Modules PNP Solid State Removable Auto./Manual Monitored Manual 24V DC -94 440R-W2219 MSR20P Input Module 2 PNP Solid State Removable 24V DC from the base unit -98 440R-W2218 Note: For additional Safety Relays connectivity, see the Safety Relays section (page -8) of this catalog. For additional Safety I/O and Safety PLC connectivity, see the Programmable Safety System section (page -107) of this catalog. For application and wiring diagrams, see the Safety Applications section (page 10-1) of this catalog. Connection Systems Trojan Trojan 6 -Pin Micro (M12) 6-Pin Micro (M12) 8-Pin Micro (M12) Description Cordset 889R-F6ECA- 889D-F8AB- Patchcord 889R-FECRM- 889R-F6ECRM- 889D-F8ABDM- Distribution Box 898R-F68MT-A Shorting Plug 898R-P61MU-RM T-Port Replace symbol with 2 (2 m), ( m), or 10 (10 m) for standard cable lengths. Replace symbol with 1 (1 m), 2 (2 m), ( m), ( m), or 10 (10 m) for standard cable lengths. Replace symbol with 4 or 8 for number of ports. Note: For additional information, see the Safety Connection System section (page 7-1) of this catalog. 4-24 Visit our website: www.ab.com/catalogs

Accessories Safety Description To Be Used With: Dimensions Cat. No. Standard Actuator Trojan T and T6 Standard Models Only -1 440K-A1109 1-2 -Interlock 4 GD2 Standard Actuator GD2 Models Only -0 440G-A27011 GD2 Flat Actuator GD2 Models Only -1 440K-A11112 Alignment Guide with Semi-Flexible Actuator Discard Alignment Guide for GD2 Models -1 440K-A11144 Alignment Guide with Fully-Flexible Actuator Discard Alignment Guide for GD2 Models -2 440K-A27010 Sliding Bolt Actuator GD2 Models Only - 440G-A2716 Catch and Retainer Kit Trojan T and T6 Standard Models Only -0 440K-A11094 Trojan T Standard Models Only 440A-A1149 Replacement Cover Trojan T GD2-4 440A-A11496 Trojan T6 Standard Models Only 440A-A11497 Trojan T6 GD2 440A-A11498 Dust Cover All Models -4 440K-A17180 Visit our website: www.ab.com/catalogs -2

Safety Approximate Dimensions mm (inches) Dimensions are not intended to be used for installation purposes. Standard Model End Entry 2 (1.26) (0.2) 1.7 (0.62) 9 (0.) 1.7 (0.62) 20. (0.2) 9 (.74) 1-2 -Interlock GD2 Model 2 (1.26) 1.7 (0.62) 2 (1.26) 20. End Entry (0.2). (0.22) 2 (2.0) 14 (0.) 24 (0.94) 24 (0.94) 46 (1.81) 7 (0.28) (0.2) 20.. (0.22) Front Entry 40 (1.7) 1.7 (0.62) Mounting Holes for M Screws 8 (0.1) 9 (0.) 6 (1.42) 9 (.74) (0.2) (0.2). (0.22) Front Entry 2 (2.0) 20. 40 (1.7) 4 Note: 2D, D and electrical drawings are available on www.ab.com. 46 (1.81) 7 (0.28) 1.7 (0.62) Mounting Holes for M Screws 8 (0.1) -26 Visit our website: www.ab.com/catalogs

H $ H H L H $ Typical Wiring Diagrams Description Safety Trojan Trojan 6 2 N.C. & 1 N.O. 2 N.C. & 2 N.O. N.C. & 1 N.O. Contact Configuration Contact Action 6-Pin Micro (M12) 2 4 6 78 9 4 : % & ' ( ) * + % & ' ( ) *, + -. + @ = G G I J G -Aux A 4-Aux A! " # "$ 1-2 -Interlock 4 / / $ 0 "$ / /! " % & ' ( ) * + % & ' ( ) * + % & ' ( ) *, % & ' ( ) *, + -. + % & ' ( ) * 1 + -., + -. + 0 " #! " BBM BBM BBM ; < ; = > < > @ = K K @ = ; < ; = > < = K K @ = ; < ; = > < G G G I J G G I J H G I J > = > = MBB MBB MBB 6-Safety B 2-Safety B / / = K K -Pin Micro (M12) for ArmorBlock Guard I/O -Safety A -Safety B -NA 8-Pin Micro (M12) 2-Safety A 1-Safety A 1-Safety A 4-Safety B -NA 8-Safety A 4-Safety B -Safety A 2-NA 1-Aux A 7-Aux A 6-Safety B Red/White Red/Black Safety A 6-Pin Cordset Red Safety B 889R-F6ECA- Red/Blue Green Red/Yellow Aux Grey Red Safety A Yellow 8-Pin Cordset Pink Safety B 889D-F8AB- White Blue Aux A Green Brown NA Replace symbol with 2 (2 m), ( m) or 10 (10 m) for standard cable lengths. Visit our website: www.ab.com/catalogs -27