TM3SAK. Main. Device short name

Similar documents
TM3SAF. Main. Device short name

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

TM3DI16G module TM3-16 inputs spring

TM3DI16 module TM3-16 inputs

TM3AI4 module TM3-4 analog inputs

TM3TI4 module TM3-4 inputs temperature

TM3TI8T module TM3-8 inputs temperature

XPSMCMDI Input expansion module with screw term

TM3TI4 module TM3-4 inputs temperature

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

TM3TM3 module TM3-2 temperature inputs and 1 analog output

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

XPSMCMDO Digital output pairs expansion modules with screw term

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

TM241CE24T controller M IO transistor PNP Ethernet

XPSMCMMX inputs 2 output pairs expansion module with screw term

TM241CE40R controller M IO relay Ethernet

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

TM3DI8A module TM3-8 inputs 120V AC

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

TM3DM8R module TM3-8 IO relays

XPSMC32Z safety controller XPS-MC - 24 V DC - 32 input - 46 LEDs signalling

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

TM241C24T controller M IO transistor PNP

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

RM35LM33MW liquid level control relay RM35-L V AC/DC

TM241C40R controller M IO relay

TM241C40U controller M IO transistor NPN

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

TM200C24R controller M IO relay

RE9RA21MW7 off-delay timing relay s V AC -

XMLP200PD730 pressure transmitter - XMLP - 200psi - 1/4"18NPT V - M12 - set 1

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

TM221CE40R controller M IO relay Ethernet

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

TM241CE24U controller M IO transistor NPN Ethernet

TM241CE40R controller M IO relay Ethernet

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

TM221M16R controller M IO relay

TM221CE24R controller M IO relay Ethernet

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TM221CE40T controller M IO transistor PNP Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE40T controller M IO transistor PNP Ethernet

TM200CE24T controller M IO transistor Source+ Ethernet

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

K1F006ALH cam switch - 6-pole A - screw mounting

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

TM221CE40R controller M IO relay Ethernet

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

TM241CE40R controller M IO relay Ethernet

XB7EV07BP round pilot light Ø 22 - clear - integral LED - 24 V - screw clamp terminals

RM4TA32 three-phase network control relay RM4-T - range V

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

XGCS491B201 Standalone panel smart antenna

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

TM221M32TK controller M IO transistor PNP

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

ABS2EC01EB input interface module mm - solid state - 24 V DC

RM4TR31 three-phase network control relay RM4-T - range V

TM241CEC24R controller M IO relay Ethernet CAN master

TM221ME32TK controller M IO transistor PNP Ethernet

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

TM221ME16T controller M IO transistor PNP Ethernet

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

TM221CE24T controller M IO transistor PNP Ethernet

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

TM221M16TG controller M IO transistor PNP spring

Transcription:

Product datasheet Characteristics TM3SAK6R SAFETY MODULE FOR PLC TM2xx, 3 FUNCTIONS, CAT4, SCREW TERMINALS Complementary Main Range of product Product or component type Device short name Safety module application Function of module Modicon TM3 Safety Safety module TM3SAK For emergency stop, switch, sensing mat/edges or safety light curtain monitoring Emergency stop monitoring 1-channel wiring Emergency stop monitoring 2-channel wiring Monitoring of a movable guard Multiple emergency stop monitoring 2-channel wiring Sensing mat and edges monitoring Monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP Proximity sensor monitoring PNP/PNP Monitoring of electro-sensitive protection equipment (ESPE) PNP/NPN Proximity sensor monitoring PNP/NPN Monitoring of a movable guard with 2 switches and automatic start Safety level Can reach PL e/category 4 EN/ISO 13849-1:2008 Can reach PL e/category 4 EN/ISO 13849-2:2012 Can reach SILCL 3 EN/IEC 62061:2005 Can reach SIL 3 EN/IEC 61508:2010 Safety reliability data DC = 95 % EN/ISO 13849-1 PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC 4 A PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC 1 A MTTFd = 500 years EN/ISO 13849-1 1 operation/hour DC-13 24 V DC 4 A MTTFd = 85 years EN/ISO 13849-1 60 operations/hour DC-13 24 V DC 1 A SFF = 95 % IEC 61508-1 HFT = 1 IEC 61508-1 Type = A IEC 61508-1 Synchronisation time between inputs Connections - terminals Unlimited 2 or 4 s depending of wiring configurable by software Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34 Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34 Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34 Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34 Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² flexible without cable end 13-14, 23-24, 33-34 Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² solid without cable end 13-14, 23-24, 33-34 Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34 Captive screw clamp terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34 Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.5 mm² flexible without cable end other terminals 1 / 7 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Number of safety circuits Output type Maximum switching voltage Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.75 mm² solid without cable end other terminals Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 0.34 mm² flexible with cable end, without bezel other terminals Captive screw clamp terminals, removable terminal block 2 x 0.5 mm² flexible with cable end, with double bezel other terminals 3 NO (relay instantaneous opening) [Us] rated supply voltage 24 V DC - 15...20 % Power consumption in W Input protection type Control circuit voltage Cable length Breaking capacity Breaking capacity Output thermal current [Ith] conventional free air thermal current 3 NO relay instantaneous opening potential free 230 V utilisation category AC-15 at 50 Hz (relay instantaneous opening) 24 V utilisation category DC-13 (relay instantaneous opening) 0.2 W 5 V DC 3.6 W 24 V DC Internal, electronic 24 V DC <= 30 m 360 VA holding AC-15 B300 relay output 3600 VA inrush AC-15 B300 relay output 4 A 24 V 50 ms DC-13 relay output 6 A per relay relay output Associated fuse rating 4 A gg or gl relay output EN/IEC 60947-5-1 6 A fast blow relay output EN/IEC 60947-5-1 Minimum output current Output voltage Response time on input open 18 A 10 ma relay output 10 V relay output <= 40 ms [Ui] rated insulation voltage 300 V 2 IEC 60647-5-1 [Uimp] rated impulse withstand voltage 4 kv III IEC 60647-5-1 Current consumption Local signalling Electrical connection 100 ma 24 V DC external supply 8 LEDs green/red user Screw terminal Product compatibility Safety light curtains EN/IEC 61496-1 (type 4) Sensing mat/edges EN 1760-1 Standards EN/ISO 13849-1:2008 EN/ISO 13849-2:2012 EN/IEC 62061:2005 EN/IEC 61508:2010 EN/IEC 60947-5-1:2010 EN/IEC 61131-2:2007 EN/IEC 60204-1:2005 EN/IEC 60204-1:2009/A1 IEC 61010-1:2010 EN 50581:2012 Product certifications Marking Electromagnetic compatibility TÜV RCM EAC UL 61010-2-201 CSA 61010-2-201 (pending) ANSI Haz Loc Class 1 Division 2 (pending) CSA Haz Loc Class 1 Division 2 (pending) CE CSA UL EFUP 10 REACH TÜV EAC RCM Electrostatic discharge immunity test 8 kv air discharge conforming to EN/IEC 61000-4-2 Electrostatic discharge immunity test 6 kv contact discharge conforming to EN/IEC 61000-4-2 Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3 2 / 7

Mounting support Height Depth Width Product weight Magnetic field at power frequency 30 A/m 50...60 Hz conforming to EN/IEC 61000-4-8 Electrical fast transient/burst immunity test 3 kv power lines (DC) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test 2 kv I/O conforming to EN/IEC 61000-4-4 1.2/50 µs shock waves immunity test 1 kv power lines (DC) conforming to EN/IEC 61000-4-5 Conducted RF disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6 Radiated emission 40 dbµv/m class A 24 V conforming to EN 55011 Radiated emission 47 dbµv/m class A 24 V conforming to EN 55011 Wall mount using attached fasteners Rail top hat type TH35-7.5 IEC 60715 Rail top hat type TH35-15 IEC 60715 94 mm 73 mm 43.7 mm 0.19 kg Environment standards EN 1088/ISO 14119 EN 60204-1 EN/IEC 60947-1 EN/IEC 60947-5-1 EN/ISO 13850 resistance to electrostatic discharge 8 kv in air EN/IEC 61000-4-2 6 kv on contact EN/IEC 61000-4-2 resistance to electromagnetic fields 10 V/m 80 MHz...1 GHz EN/IEC 61000-4-3 3 V/m 1.4 GHz...2 GHz EN/IEC 61000-4-3 1 V/m 2 GHz...3 GHz EN/IEC 61000-4-3 resistance to magnetic fields 30 A/m 50...60 Hz EN/IEC 61000-4-8 resistance to fast transients surge withstand resistance to conducted disturbances, induced by radio frequency fields 3 kv power lines (DC) EN/IEC 61000-4-4 DC 2 kv I/O lines EN/IEC 61000-4-4 1 kv power lines (DC) differential mode EN/IEC 61000-4-5 DC 1 kv power lines (DC) common mode EN/IEC 61000-4-5 DC 10 V 0.15...80 MHz EN/IEC 61000-4-6 electromagnetic emission Radiated emissions 50 dbµv/m class A 24 V DC 30...230 Hz IEC 61131-3 Radiated emissions 57 dbµv/m class A 24 V DC 230...1000 Hz IEC 61131-3 ambient air temperature for operation ambient air temperature for storage -25...70 C relative humidity IP degree of protection pollution degree 2 operating altitude storage altitude -10...55 C horizontal installation 10...95 % without condensation in operation 10...95 % without condensation in storage IP20 EN/IEC 60529 terminals 0...2000 m 0...3000 m vibration resistance +/- 3.5 mm 5...150 Hz IEC 60068-2-6 shock resistance 15 gn 11 ms IEC 60068-2-27 mechanical robustness Bumps 6 ms 300 shocks 25 gn IEC 60068-2-27 Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Green Premium product Compliant - since 1408 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Available Available Dimensions 3 / 7

(*) 8.5 mm/0.33 in when the clamp is pulled out. Spacing Requirements Mounting on a Rail Incorrect Mounting Mounting on a Panel Surface (1) Install a mounting strip Mounting Hole Layout 4 / 7

Emergency Stop Wiring Diagram S1 : Emergency stop switch S2 : Start switch (1) Safety outputs (2) Monitored start (3) Non-monitored start (4) For automatic start, directly connect [S33] and [S39] terminals (5) Second external device monitoring channel. Connect [S41] and [S42] terminals if not used (6) Fuses. Refer to technical specifications for fuse values (7) Non-safety related TM3 Bus communication with logic controller Protective Guard Wiring (1) Protective guard 5 / 7

Electro-Sensitive Protective Equipment (ESPE) Wiring S2: Start switch NOTE: The ESPE must be supplied by the same PELV/SELV power supply as the safety module. Safety-Mat Wiring (1) Safety-mat NOTE: Normally, most safety-mats are maladapted for use in combination with the automatic start mode. In addition, if you use the safety-mat in your application which includes the automatic startmode, you should consider this in your risk analysis. Emergency Stop Wiring One Channel S1: Emergency stop switch Two Channel S1: Emergency stop switch NOTE: Inputs S11 and S12 are not intended for the monitoring of short circuits in external wiring. 6 / 7

Proximity Sensors Wiring Without Short Circuit Detection NOTE: The sensors must be supplied by the same PELV/SELV power supply as the safety module. With Short Circuit Detection NOTE: The sensors must be supplied by the same PELV/SELV power supply as the safety module. Synchronization Time Monitoring Chronogram 2 Channel Application 1 : S2 operated before S3 2 : S3 operated before S2 3 : Outputs are not activated because the synchronization time is expired. 7 / 7