AS-Interface Safety at Work

Similar documents
Communication & Networking

Communication & Networking

SX5A AS-Interface(Communication Terminal and Repeater)

Oiltight Switches & Pilot Devices

Communication & Networking

Oiltight Switches & Pilot Devices

Communication & Networking

Communications & Networking

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Switches & Pilot Devices

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Automation & Sensing Communication &

Table of Contents LED Machine Lighting - Pg. 1 Automation & Sensing - Pg. 27 Safety - Pg. 255 Switching & Controls - Pg. 449 Index - Pg.

Timers. GT3W Series Dual Time Range Timers. 250V AC/150V DC Time Range. 1: 0.1sec to 6 hours, 3: 0.1sec to 300 hours

Intrinsically Safe Explosion Proof Barriers

Relays & Sockets RR Series Power Relays. Part Number Selection

Varistor installation. Input logic. Voltage of relay coil

Communications & Networking

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

Light Curtains. Type 4 SG4. Type 4 SG4 Series. 468

RTE Series Analog Timers. UL Listed File No. E kPa to 110kPa (Operating), 70kPa to 110kPa (Transport)

SA1E: Photoelectric Switches. Polarized Retroreflective Type. Through-beam Type

XB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC

Barriers. EB3N Discrete Input Barrier with Redundant Output

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

Model Number Structure

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

One step ahead in performance and mounting ease

FS1A Safety Controller

FS1A Safety Controller

Model Number Structure

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs

DIN Rail Mounting Accessories. Style Appearance Use with Timers Part No. Appearance Part No. RTE-P2 SR3P Pin FingerSafe Socket RTE-P2 SR3P-05C

Model Number Structure

Safety Control. Safety.

Safety Control. Safety. Selection Guide Safety Relay HR1S-AC Safety Relay HR1S-AF

Barriers. Discrete Output Barrier

Safety Relay Unit (I/O Unit Type)

Timers. GT5Y Series ON Delay Timers. ±3% maximum (over 10 to 50 C, reference temperature 20 C) Setting Error. ±10% maximum

H3CA-8H-AC/100/110/120

XB5AS8445 red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Timers NEW DESIGN! RTE Series. RTE Series Analog Timers

GT3F Series True OFF Delay Timers

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

NX integrated safety System configuration. Integrated safety into machine automation

Operation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR

Digital I/O Units Compatible with MULTIPLE I/O TERMINAL

XB4BS542 red Ø40 Emergency switching off pushbutton Ø22 latching turn release 1NC

Solid-state Timer H3YN

Oiltight Switches & Pilot Devices

Push Buttons and Operator Interface New Product Catalog XAL Control Stations

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

PRODUCT SPECIFICATION. PC Board Relays. Series.

BGS (at min. setting) BGS (at max. setting)

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

XB4BT845 Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC+1NO

Compact Inductive Proximity Sensor

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

J8 SWITCHES WITH TRIP FUNCTION UPGRADED TYPE

2. Actuator B: Ball type P: Pin type F: Flat type

Switches & Pilot Devices

The World s in Compactness. * Among photoelectric sensors with built-in amplifier, as of June 2015 (survey by our company)

General Data. Ambient Conditions - Operating temperature: -25 C C - Storage temperature: -40 C C - Humidity: up to 95%, non-condensing

Switches & Pilot Devices

Remote I/O Unit with Connectors for Light Curtain CC-Link Safety System. panasonic.net/id/pidsx/global

4.6 Monochrome STN LCD Touchscreen - HG1F

ZB5AT8643M red Ø40 illum Emergency stop pushbutton head Ø22 trigger and latching

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

XB4BT842 Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC

Magnetic and Hydraulic-Magnetic Circuit Breaker

Ultra Slim Relays 24

No. 1. The World s in Compactness. Amplifier Built-in Ultra-minute Photoelectric Sensor EX-Z SERIES panasonic.net/id/pidsx/global

ZB5AW743 red Ø40 illum mushroom pushbutton head Ø22 latching for integral LED

Suitable for detecting transparent films or transparent bottles

Photoelectric Sensors E3F2

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

XB7EV07BP round pilot light Ø 22 - clear - integral LED - 24 V - screw clamp terminals

Optimum sensing capability for LCD manufacturing

Long-distance Photoelectric Sensor with Built-in Amplifier. Connection method Sensing distance. --- Retro-reflective. (500 mm) Terminal block ---

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Pushbutton and selector switch series Quality touch!

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available

V-3000 Series Miniature Basic Switches

XB7NG33 key selector switch - Ø 22 - keylock - 3 positions - 2 NO - Ronis 455 center

XB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"

Accessory Kit for all Designs of Hand-held Pendant Station

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Vandal-proof latching action switch MSM LA

Terminal block 2 A 5 X 3. Specification

Self-Powered Counters H7EC

Transcription:

Safety Emergency Stop Switches... 478 Operating Instructions... 482 www.idec.com/safety AS-Interface Safety at Work Light Curtains Table of Contents LED Lighting - Pg. 1 Automation & Sensing - Pg. 21 Safety - Pg. 281 Switching & Controls - Pg. 483 Index - Pg. 139

AS-Interface safety at work integrates a safety network into one wire-saving system. Work, further reducing wiring. Safety slaves and safety monitors can be simply connected to the existing AS-Interface network to establish the. Safety components can be connected to other networks through gateways. Interlock switches, safety relay modules and other safety components can be connected to the safety network via safety slaves. Emergency stop switches can be connected directly to AS-Interface Safety at SX5A AS-Interface Safety Communication Terminal (Safety Slave) Safety Relay Module Grip Switch Safety Relay Module Light Curtain SX5A AS-Interface Safety Communication Terminal (Safety Slave) M12 Cable for Plastic Control Box Light Curtains Interlock Switch HS1B, HS2B, HS5B, HS6B 476 XA/XW Series www.idec.com

MicroSmart Series AS-Interface Master Module + FC4A FC5A Non-contact Interlock Switch PLC Gateway SX5A AS-Interface Safety / Gateway SX5A AS-Interface I/O Module Control Unit SX5A AS-Interface Safety Monitor PS2R AS-Interface Power Supplies Light Curtains Safety slaves and standard slaves can be connected to one network. 8-262-IDEC (4332) USA & Canada HW Series Photoelectric Switches L6 Series 477

Emergency Stop Switches Light Curtains Emergency Stop Switches XA Series/XW Series/ (Plastic Enclosures) with Safety Slave Functions for Direct Connection to the AS-Interface Safety at Work Emergency stop switches with safety slave functions can be connected to the network. Complies with IEC 6158 SIL3 (Functional safety of electrical/electronic/programmable electronic safety-related systems) and EN954-1 safety category 4 (Safety of machinery-safety related parts of control systems). Space, wire, and labor-saving solutions for safety equipment Equipped with AS-Interface standard slave functions. Monitored with AS- Interface master devices. A wide variety of safety components: 1) (non-illuminated) and /1-OUT (illuminated) available. 2) FB series plastic control stations with ø16mm XA series and ø22mm XW series emergency stop switches available. 3) XA series available with ø29mm and mm mushroom buttons and XW series available with mm and ø6mm jumbo mushroom buttons. 4) Terminal connectors are available in insulation displacement, crimping, and M12 connectors which enable effective connection of multiple switches. ø16mm XA Series Part Numbers Button Size Connector Terminal I/O Points Illumination Part Number Button/Lens Color ø29 IDC ø22mm XW Series XA1E-BV3Z1C1R XA1E-BV3Z1C1N 1-OUT Illuminated XA1E-LV3Z114C1R XA1E-BV4Z1C1R 1-OUT Illuminated XA1E-LV4Z114C1R Button Size Connector Terminal I/O Points Illumination Part Number Button/LensColor ø6 IDC Crimping IDC Crimping IDC E-Stop Enclosure Crimping 1-OUT Illuminated XW1E-BV4Z1C1R XW1E-BV4Z1C2R XW1E-LV4Z114C1R XW1E-LV4Z114C2R XW1E-BV5Z1C1R XW1E-BV5Z1C2R Button Size Connector Terminal I/O Points Illumination Nameplate Part Number Button/Lens Color M12 Without With Red Gray Red Red FB1W-XW1E-BV4Z1C2R-Y-1 FB1W-XW1E-BV4Z1C2R-Y1-1 Without FB1W-XW1E-LV4Z114C2R-Y-1 Illuminated 1-OUT With FB1W-XW1E-LV4Z114C2R-Y1-1 ø6 Without FB1W-XW1E-BV5Z1C2R-Y-1 AS- Interface Piercing 1-OUT Illuminated Without With Without With FB1W-XW1E-BV4Z1C2R-Y-2 FB1W-XW1E-BV4Z1C2R-Y1-2 FB1W-XW1E-LV4Z114C2R-Y-2 FB1W-XW1E-LV4Z114C2R-Y1-2 ø6 Without FB1W-XW1E-BV5Z1C2R-Y-2 1. Units have been evaluated as emergency stop devices by TÜV. 2. Units with nameplates are engraved Emergency Stop. Red 478 www.idec.com

Emergency Stop Switches Accessories Name Specification Part Number XA/XW Series End connector (with cover) XW9Z-C1-1 IDC Connector Kit 1 Through connector (with cover) XW9Z-C1-2 IDC Connector Termination Tool Manufactured by ITW Pancon MMIT-156F Crimping Type Connector Cable Control Station M12 Connector Cable Length 5 mm, with one connector Length 1m, with one connector Length 3 mm, straight Length 1m, straight Length 2m, straight Length 1m, right-angle Length 2m, right-angle XW9Z-C25 XW9Z-C21 FB9Z-CS3 FB9Z-CS1 FB9Z-CS2 FB9Z-CL1 FB9Z-CL2 Hand-held Programming Device 2 SX9Z-ADR1N General Communication 1. Minimum order is 5 pieces. IDC connector termination tool MMIT-156F (ITW Pancon) may be required to connect the cable to the connector. 2. *Hand-held programming device accessories: -Programming device cable (SX9Z-CN1) -Programming device AC adapter (SX9Z-ADPT) -SwitchNet addressing port adapter (LA9Z-SNADP) Operating Voltage Rated Input Current Dielectric Strength Insulation Resistance Operating Temperature Storage Temperature Operating Humidity Pollution Degree (IEC6664) Degree of Protection IEC6529 Corrosion Immunity Vibration Resistance Specifications 26.5 to 31.6V DC (supplied from AS-Interface) Illuminated type: 35 ma (XA series), 4 ma (XW, FB series) type: 25 ma 5V AC, 1 minute 1 MΩ (5V DC megger) XA, XW series: -25 to +55ºC (no freezing) FB series: Illuminated type -25 to +5ºC (no freezing) type -25 to +55ºC (no freezing) -4 to +7ºC (no freezing) 45 to 85% RH (no condensation) XA, XW series - Operator unit: 3, Communication unit: 2, FB series: 3 (2 - per UL) Operator unit: IP65 Terminal unit: IP2 (FB series: IP65) Free from corrosive gases Damage limits/operating extremes: 1 to 5 Hz, amplitude.35 mm, acceleration 5 m/s 2 Shock Resistance Damage limits: 15 m/s 2, Operating extremes: 1 m/s 2 XA series ø29: 35g, : 4g Weight (approx.) XW series : 6g, ø6: 7g FB series M12 connector: 195g (), 25g (ø6) Piercing: 235g (), 245g (ø6) Communication AS-Interface Ver. 3. Slave Type Safety slave Maximum Network Length 1m total Maximum No. of Slaves 31 (when only safety slaves are connected) Profile (I/O, ID, ID2) S-7, B, E (illuminated type) S-, B, E (non-illuminated type) Emergency stop switch DI DI1 DI2 DI3 When pressed Input Emergency stop switch DI DI1 DI2 DI3 Data Bit When not pressed X X X X x:.1 (unspecified) Output DO = 1 Pilot light: on DO1 to 3: not used DO = Pilot light: off Parameter Bit Not used Light Curtains 8-262-IDEC (4332) USA & Canada 479

Emergency Stop Switches Operating Force Minimum Force Required for Direct Opening Action Pushlock: 1.5N (XA series), 32N (XW, FB series) Pull reset: 1N (XA series), 21N (XW, FB series) Turn reset:.16n m (XA series),.27 N m (XW, FB series) 6N (XA series), 8N (XW, FB series) Mechanical/Electrical Minimum Operator Stroke Required for Direct Opening Action Maximum Operating Stroke Operating Frequency Mechanical Life Electrical Life Connectors Recommended Tightening Torque for Locking Ring 4. mm 4.5 mm 9 operations/hour 25, operations minimum 25, operations minimum IDC connector (XA series) IDC connector, crimping connector (XW series) M12 connector/as-interface piercing connector (FB series).88 N m (XA series), 2. N m (XW series) XA/XW Series 1 2 1 2 Pin Assignment (M12 Connector) (AS-Interface Piercing Connector) 1 1: AS-i+ 2: AS-i- 2 4 1 2 IDC: XW9Z-C1-1 (End connector) XW9Z-C1-2 (Through connector) Light Curtains 1 2 3 48 www.idec.com

Emergency Stop Switches Dimensions XA Series 76. ø29 76. 45 2.6 5.3 2.6 AS-Interface Cable Piercing Model M12 Connector Model 76. 76. 59.5 Without nameplate: 32 With nameplate: 33.5 59.5 Without nameplate: 32 With nameplate: 33.5 Mounting Centers XA Series XA Size ø29 ø6 X & Y 4mm minimum 5mm minimum 7mm minimum The above values are for installing with ø16mm pushbutton switches. For using with control units of other size and operator shape, determine the mounting centers in consideration of easy operation and wiring. XW Series XW Size øa X & Y 4mm 22.3 +.4 7mm min Communication Block IDC Connector (Optional) ø16.2 +.2 31.1 3.3 1.7 4-M4 Tapping Screw Holes for Rear Mounting (Depth: 1 mm) 2-Front Mounting Holes ø14 Knockout 21 +.2 29.6 Panel Cut-out 15.5 62 21 41 2-ø4.6 4-M4 Tapping Screw Holes for Rear Mounting (Depth: 1 mm) 2-Front Mounting Holes ø14 Knockout 21 Y Y 15.5 62 21 41 ø16.2 +.2 øa 2-ø4.6 X X 17.9 +.2 XW Series ø6 M12 Connector Cable for L 25 35 Resetting 32 32 5 7 4.2 2 4 54.2 59.5 19 Communication Block 33.6 IDC Connector (Optional) R.8 max. ø22.3 These emergency stop switches are push-lock, pull/turn reset types. When pressed, the operator is latched, and reset by pulling or turning. +.4 17.4 2.1 3.2 +.2 Panel Cut-out +.4 24.1 Light Curtains 8-262-IDEC (4332) USA & Canada 481

Operating Instructions Light Curtains AS-Interface Safety Monitor Wiring and Installation Before wiring the interface cable, discharge static electricity. Tighten the screws to a torque of.8 to 1.2 N m. The AS-Interface power supply unit must separate the main power (input) and output safely according to IEC 6742. It must also maintain a stable supply in the event of instantaneous power failure. Replacing the Safety Slave Press Service button before and after replacing the safety slave. Resetting of safety monitor using the PC is not necessary. After replacement, check whether the new safety slave performs correctly. Replacing the Safety Monitor The settings of the safety monitor can be transferred to the new safety monitor using the download cable sold separately, and the new safety monitor does not require resetting using software. After replacement, check whether the new safety monitor performs correctly. AS-Interface Safety Communication Terminal & Base Module Wiring The AS-Interface safety communication terminal will be connected to the AS- Interface network via the base module. When only one AS-i flat cable is used, plug the unused grooves using the gaskets supplied with the base module. Tighten the screws to a torque of.7 N m maximum. Before wiring, disconnect the safety communication terminal and discharge static electricity with an adequate method. Connect the emergency stop switches and interlock switches in normally-closed status. The slave has two independent inputs for connecting the products to comply with the required safety category. When complying with safety category 4, limit the cable length between the module and the input device to not longer than 3m. For leading in the cables, use the upper part (1 and 2), and tighten the cable gland to a torque of.5 to.7 N m. Operating Instructions Emergency Stop Switches Panel Mounting The panel thickness should be within the range from.8 to 6. mm. Remove the locking ring from the operator and check that the rubber gasket is in place. Insert the operator from panel front into the panel hole. Face the side without thread on the operator with TOP marking upward, and tighten the locking ring using ring wrench MW9Z-T1 to a torque of 2. N m maximum. Do not use pliers. Do not tighten with excessive force, otherwise the locking ring will be damaged. To prevent the XW emergency stop switches from rotating when resetting from the latched position, use of an anti-rotation ring (HW9Z-RL) or a nameplate is recommended. Address Setting The lid of the address setting device on the side of the unit can be removed by prying it out. Take care not to lose the lid, which comes off completely. By removing the lid of the address setting section, you can see the terminals for connecting a programming cable. Connect the programming cable to the terminals. To set an address while mounting this product on the panel, more than 6mm space is necessary on the left side in terms of the AS-Interface communication unit. Note that adequate space cannot be allocated by the distance specified with minimum mounting centers. If adequate space cannot be allocated, set the address before installing the product on the panel or set the address after removing the AS-Interface communication unit from the operation section. Wiring A maximum of 31 units can be connected to a network. Addresses must be assigned to avoid overlaps. This product allows connecting safety slaves with safety equipment, and normal slaves without safety equipment at the same time. Do not connect safety related signals to a normal slave. The AS-Interface slaves are divided into two types: A/B slaves with expanded addresses and standard slaves without expanded addresses. If A/B slaves and standard slaves are connected simultaneously, the maximum number of slaves connectable to a network may exceed 31. The network length is a maximum of 1 meters, including all wires. However, the maximum possible length of the wires may actually be shorter than 1 meters depending on the type of master and composition of slaves. Consider the lengths of cables and wiring topology so that voltage drops in transmission lines are no higher than 3V. Use applicable two-wire flat cables for wiring. Do not operate the switch using solid object such as metal or with excessive force, otherwise the switch may be deformed or damaged, causing malfunction or operation failure. 482 www.idec.com