DIAS Interface Module VARAN DIV 511

Similar documents
VARAN Splitter Module VSV 041

VARAN Manager PCI Insert module PCV 521 Versatile Automation Random Access Network

C-DIAS VARAN Control Module CIV x VARAN-In 1 x VARAN-Out (Optional Ethernet (VtE))

VARAN Bus Coupler Module VBC 021 For connecting two VARAN bus systems

VARAN Splitter PROFINET VSP 044

VARAN Splitter Module VSV 043

VARAN Splitter PROFINET VSP 042

VARAN Digital Combined Module VDM 086

Protected VARAN Digital Mixed Module PVDM 086

VARAN-INTERFACE VAC 012

VARAN Client Board VEB 011/012 Versatile Automation Random Access Network

VI 021 S-DIAS VARAN Control Module

C-IPC Expansion VM 052 (C-IPC VARAN Manager 052) Versatile Automation Random Access Network

C-DIAS Digital Input Module CDI 161 with 16 inputs

C-DIAS EtherNet/IP Slave CIP 022

to 12a Added Standard and Electrical requirements for UL table 1.1

TSY 041 Training System Extension Motion

SE 051 S-DIAS Splitter Ethernet

Technical Data. C-DIAS-MULTI l/o MODULE CIO 013

Expansion Module HZS 541-1S

C-DIAS Temperature sensing module CAI x temp. inputs C 8 x digital outputs +24V

PC 521 Data Recording PC

ISE 021 S-DIAS Interface Module RS232 / RS485

TO 161 S-DIAS Digital Output Module

Internal Buffer/Boiler Module HZS 534

ICA 012 S-DIAS Interface Module CAN

HZS Internal Controller Expansion

Added Standard and Electrical requirements for UL table Switching-off inductive loads 1.2

DM 161 S-DIAS Digital Mixed Module

RMCN22BD Analog Converter ma - for Zelio Analog

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

C-DIAS-Temperature Recording module CAI x Temp. inputs 50 C to +150 C

AO 081 S-DIAS Analog Output Module

KL 181 S-DIAS +24 V Potential Distributor Module

C-DIAS Analogue Output Module CAO 081 for eight 10V DC outputs

TN-5308 Quick Installation Guide

C-DIAS Serial Interface CSI 021

C-DIAS Analogue Conversion Module CAM 124 for eight 0 10V DC inputs and four 10V outputs

AO561 Analog Output Module

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

RO 051 S-DIAS Relay Output Module

AI561 Analog Input Module

IST ULTRASTAB Power Supply for high precision transducers

ETT 312 Build-In Touch Terminal

DI572 Digital Input Module

DX561 Digital Input/Output Module

TF501, TF521 Terminal Bases

C-DIAS Analogue Conversion Module CAM 011 for 3 x 0-10V DC inputs 2 x PT100 inputs and 1 x ±10V output

DI561 Digital Input Module

C-DIAS Profibus DP Slave module CPB 021

TU531, TU532 Terminal Unit

MOXA EtherDevice Switch

DC562, digital input/output module,

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

GIN-SAM4. Hardware User Manual. Version: 1.02 Date: Language: English

MINI-PS AC/10-15DC/8

JUMO mtron T Measuring, Control, and Automation System

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

SI 021 S-DIAS SSI Interface Module

DATA SHEET DEPRECATED - PCM5 1. Document no.: N/A

Profibus DP slave. dual ported RAM 2Kbyte. Maximum length for I/O data. Maximum length for output data. Status display

AO523 Analog Input Module

Auxiliary Board MP-Bus HZS 562

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

CM597 Ethernet Communication Module

DC561, digital input/output module,

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TCNM-ACBB1 Installation Manual

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

PS 101 S-DIAS Power Supply Module

DC S-DIAS Axis Module

Keyboard Unit Sigmatek

TM241CE24T controller M IO transistor PNP Ethernet

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Faults on the system Proximity switch connection technology:

PTC-101-M12 Hardware Installation Guide

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives

PHOENIX CONTACT

HZS Solar Module

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

PHOENIX CONTACT Features

MobileView Junction Box

TRIO-DIODE/12-24DC/2X10/1X20

SITOP in the SIMATIC Design

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

AI531 Analog Input Module

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

C-DIAS Analog Module CAO 086 For eight ±10 V Outputs

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

Processor module DCP 642

CM589 PROFINET Communication Module

CM579-PNIO PROFINET Communication Module

TM241CE24U controller M IO transistor NPN Ethernet

PTC-101 Quick Installation Guide

Transcription:

DIAS INTERFACE MODULE VARAN DIV 511 DIAS Interface Module VARAN DIV 511 1 x VARAN-In 1 x VARAN-Out (Optional Ethernet (VtE)) The DIAS DIV 511 interface module serves as the voltage supply and connection for a decentralized DIAS bus to a CPU over the VARAN bus. The VARAN-Out port allows the construction of the VARAN bus in a line structure. The VARAN-Out port has automatic Ethernet recognition. If the VARAN-Out is connected to an Ethernet participant, it is automatically changed to an Ethernet port. Incoming Ethernet packets to Ethernet ports are, similar to using a HUB, distributed to all other in the VARAN bus system and the VARAN manager (and therewith the CPU) with VtE (VARAN transmits Ethernet). Technical Data Performance data Interface connections 1 x VARAN-In (RJ45) (maximum length: 100 m) 1 x VARAN-Out (optional Ethernet (VtE)) (RJ45) (maximum length: 100 m) 1 x DIAS bus Electrical requirements Supply voltage Current consumption of voltage supply Current consumption of power supply at +24 V DC (UL) Current capacity on C-DIAS bus (power supply for I/O modules). 18 30 V DC The current consumption is dependent on the connected loads (max.0.5a) Maximum 0.92 A Maximum 1.0 A 04.06.2012 Page 1 a

DIV 511 DIAS INTERFACE MODULE VARAN Only US and Canada: This device was evaluated for UL508 as a limited voltage/current unit (LVLC). To meet the standard requirements, the device must be powered from an isolated transformer (24 V DC) with a UL-certified fuse (UL248) in the secondary circuit. The maximum rated current is 4 A. Alternatively, a class 2 power supply can be used. Miscellaneous Article number 05-003-511 Hardware version 1.x Standard UL508 (E247993) Environmental conditions Storage temperature -20 +70 C Operating temperature 0 +50 C Humidity EMV stability 0 95 %, uncondensed According to EN 61000-6-2:2001 (industrial area) Shock resistance EN 60068-2-27 150 m/s² Protection EN 60529 IP 20 Protection Type (UL) open type device Pollution degree 2 Page 2 a 04.06.2012

DIAS INTERFACE MODULE VARAN DIV 511 Mechanical Dimensions 04.06.2012 Page 3

DIV 511 DIAS INTERFACE MODULE VARAN Connector Layout X1: VARAN-In, X2: VARAN-Out (Optional Ethernet (VtE)) Pin Function 1 TX / RX+ 2 TX / RX- 3 RX / TX+ 4-5 - 6 RX / TX- 7-8 - X3: Power plug 1 Pin Function 1 +24 V supply 2 GND Page 4 04.06.2012

DIAS INTERFACE MODULE VARAN DIV 511 Applicable connectors X1 X2: 8-pin RJ45 X3: 2-pin Phoenix pug with screw terminals MC1, 5/2-ST-3,5 2-pin Phoenix plug with spring terminals FK-MCP1, 5/2-ST-3,5 Connector Type Wire size Max. screw torque X1 RJ 45 - - X2 RJ 45 - - 0.13 1.0 mm², X3 MC1.5/2-ST-3.5 30-16 AWG (UL), 0.22 0.25 Nm 28 16 AWG (CSA) X3 FK-MCP1.5/2-ST-3.5 0.14 1.5 mm², 28 16 AWG (UL/cUL) Cage Clamp Use copper conductors only! 04.06.2012 Page 5 a

DIV 511 DIAS INTERFACE MODULE VARAN Status Display LED L/Act Vin L/Act Vout LED color Definition Description Green Link Lights when the connection between the two PHYs is established. Yellow Active Lights when data is sent or received over the VARAN-In receiver. Green Link Lights when the connection between the two PHYs is established. Yellow Active Lights when data is sent or received over the VARAN-Out receiver. Act DIAS Yellow Active Lights when the DIAS bus is active. Reset / Sync Red Reset Lights when the DIV 511 is in Reset. Green Sync Lights when the DIV 511 is synchronized with the VARAN Manager. DCOK Green DC OK Lights when connected to the 24 V supply plug Applicable Modules The DIV 511 allows the connection of nearly all DIAS modules. Only DIAS modules that require the DIAS interrupt (e.g. communication modules) must be directly connected to the CPU. Page 6 04.06.2012

VARAN Recommended Shielding DIAS INTERFACE MODULE VARAN DIV 511 The VARAN real-time Ethernet bus system offers robust performance in harsh industrial environments. Through the use of IEEE 802.3 standard Ethernet physics, the potential between an Ethernet line and sending/receiving components is kept separate. The VARAN Manager resends messages to a bus participant immediately when an error occurs. It is principally recommended that the shielding guidelines below be followed. For applications in which the bus line is run outside the control cabinet, correct shielding is required. This is especially important, if due to physical requirements, the bus lines must be placed next to sources of strong electromagnetic noise. It is recommended that whenever possible, to avoid wiring VARAN-Bus lines parallel to power cables. SIGMATEK recommends the use of CAT5e industrial Ethernet bus lines. For the shielding variants, an S-FTP bus line is recommended, which is a symmetric, multiwire cable with unshielded pairs. For the total shielding, a combination of foil and braiding is used; it is recommended that an unvarnished variant be used. The VARAN cable must be secured at a distance of 20 cm from the connector for protection against vibration! 04.06.2012 Page 7

DIV 511 DIAS INTERFACE MODULE VARAN 1. Wiring from the Control Cabinet to an External VARAN Component If the Ethernet lines are connected from a VARAN component to a VARAN node outside the control cabinet, the shielding should be placed at the entry point to the control cabinet housing. All noise can then be deflected from the electronic components before reaching the module. Page 8 04.06.2012

2. Wiring Outside of the Control Cabinet DIAS INTERFACE MODULE VARAN DIV 511 If a VARAN bus cable must be placed outside of the control cabinet only, no additional shield connection is required. This requires that only IP67 modules and connectors be used. These components are very robust and noise resistant. The shielding for all sockets in IP67 modules are internally connected to common bus or electrically connected to the housing, whereby the deflection of voltage spikes does not flow through the electronics. 04.06.2012 Page 9

DIV 511 DIAS INTERFACE MODULE VARAN 3. Shielding for Wiring Within the Control Cabinet Sources of strong electromagnetic noise located within the control cabinet (drives, Transformers, etc.) can induce interference in a VARAN bus line. Spike voltages are deflected over the metallic housing of a RJ45 connector. Noise is conducted through the control cabinet housing without further action from the electronic components To eliminate sources of noise during data transfer, it is recommended that the shielding from all electronic components be connected within the control cabinet. Page 10 04.06.2012

DIAS INTERFACE MODULE VARAN DIV 511 4. Connecting Noise-Generating Components With the connection of power components that generate strong electromagnetic noise, it is also critical to ensure correct shielding. The shielding should be placed before a power component (or a group thereof). 04.06.2012 Page 11

DIV 511 DIAS INTERFACE MODULE VARAN 5. Shielding Between Two Control Cabinets If two control cabinets must be connected over a VARAN bus, it is recommended that the shielding be located at the entry points to both cabinets. Noise can thereby be kept from reaching the electronics within the control cabinet. Page 12 04.06.2012