Advantage Series Switch-Rated IEC Pin & Sleeve. Highest Performing IEC Pin & Sleeve Connections for the Most Demanding Environments

Similar documents
IEC H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and

Wastewater Solutions. Featuring Meltric s DECONTACTOR TM Series Switch-Rated Plugs, Receptacles and Electrical Connectors. meltric.

TABLE OF CONTENTS. IEC and IEC Pin and Sleeve Devices. IEC and IEC Mechanical Interlocks. Manual Disconnect Switches

Switch rated plugs and receptacles with NEMA 4X protection

Switch-Rated Electrical

Compact plugs and receptacles standard or high temperature rated

Mining, Aggregate & Concrete Industries

MELTRIC Corporation. The best in industrial wiring devices. Product Technology & Safety. Value

SWITCH-RATED PLUGS & RECEPTACLES. DECONTACTOR Technology. meltric.com

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Pin & Sleeve. EUREKA-HD Series WATERPROOF SPLASHPROOF. Heavy duty Industrial Wiring Devices

TeSys IEC Contactors and Overload Relays

SWITCH-RATED PLUGS & RECEPTACLES. DECONTACTOR Technology. meltric.com A COMPANY OF MARECHAL ELECTRIC

Accessories & Options

Auxiliary/Pilot Contacts p. 189 Additional Watertightness p. 190 Lid Configurations p. 191 Plug Caps p. 192 Pawl Options p. 193 Auxiliary Switches p.

Accessories & Options

2013 ESL Power Systems, Inc. All Rights Reserved.

POWER CABLES FOR MISSION CRITICAL FACILITIES

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Hazardous Location plug and receptacle

Accessories & Options

Plugs, Receptacles & Connectors

Emery County Senior Center Green River 06/07

1492-SP Supplementary Protectors

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

DISCONNECTABLE MOTOR SWITCH AC-3 UP TO 45 kw

Amphenol Miniature Cylindrical Proprietary/MIL-C-26482, Series 1

ASCO SERIES 300 Manual Transfer Switch Solutions

Brasch Washdown Unit Heaters

SPECIFICATION AND PERFORMANCE CHARACTERISTICS OF DVI MALE AND FEMALE CONNECTOR SERIES

Zenith Series DPB Distributed Power Busway

M12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET

Instruction Manual HPH-8

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

Zenith Series DPB. Distributed Power Busway

ArmorConnect Power and Control Media

Versatile Safety Interlock Switch with Guard Door Locking

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Leviton Products Referenced in the Rockwell Automation ENCOMPASS Program

Product Brochure. Series 70 erpp-fs. Web-Enabled Remote Power Panel

Analog Voltage Combination Module

07. har-link Interface Connectors

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

SolConeX plugs and sockets. our new global player

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

FOOD AND BEVERAGE AUTOMATION & ELECTRICAL SOLUTIONS

Model 7705 Control Module

LIGHTING & POWER PRODUCT GUIDE HAND SOLDERED SINCE DMX - MULTI PIN - POWER DISTRIBUTION - EXTENSION CORDS

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE

V-3000 Series Miniature Basic Switches

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

A Complete Floor Box System for Concrete

07. har-link INTERFACE CONNECTORS

File E Project 08NK November 24,2009 REPORT TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7)

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

VPR A 3W3P P&S Conn. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Jockey Pump Controllers

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

IIM Warwick Court. Williamsburg VA REV 5

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

Bulletin Installation of Solar Photovoltaic Systems Section 50; Rules: , , ; Tables 11 and 19 Issued July 2010

UTS UTS. UTS provides a connection that performs faster, easier, safer and more reliable, it makes :

Posi-Lok Plugs and Panels

INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold. Tru-Break switchgear module

UL 508 A standard-compliant design of industrial control panel

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

B&W RearView Camera Installation & Operation

HE Insert Series. Product Specification Sep 11 th, 2015 Rev. B. Table of contents

SAVE THESE INSTRUCTIONS

Allen-Bradley 1492-RCDA4A40

v1.0 JL10 Series Circular Waterproof Connector Connector Training Module Copyright 2015 JAE Electronics, Inc.

UL 489 DIN Rail Miniature Circuit Breakers

THE SURGE PROTECTION SOLUTION

Surge Guard Don t Plug In Without It! Bumper to Bumper. Power Protection

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

07. har-link Interface Connectors

SECTION TRANSIENT VOLTAGE SURGE SUPPRESSION

Bulletin Installation of solar photovoltaic systems Rules , , , , and

DN9c Multipin 20A Plugs & Receptacles

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

UL 489 DIN Rail Miniature Circuit Breakers

NCLOSURES & TTERMINATIONS

AMPMODU* MOD I Interconnection System

Jockey Pump Controllers

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

TNC SERIES Miniature Coaxial Connectors

UL2930 Healthcare Facility Outlet Assemblies UL1449 Heavy Duty Surge Protection Devices. Wiring Device-Kellems

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

Disconnect Switches. Safe Switching and Disconnecting

Avanti HP Series Centrifuges Preinstallation

The reliable connector to power up your device

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

Transcription:

Advantage Series Switch-Rated IEC Pin & Sleeve Highest Performing IEC Pin & Sleeve Connections for the Most Demanding Environments

The Evolution of Pin & Sleeve Hubbell is the Only IEC 60309 Pin & Sleeve Manufacturer to Publish UL Witnessed Horsepower Results/Ratings. HUBBELL s HP Rated Pin & Sleeve are Recognized by the NEC as a Suitable Disconnecting Means. Most traditional plugs and receptacles should never be connected or disconnected under load. - Competitor s Safety Guide

What is a UL 2682 Switch-Rated Connection? North American Standard for Non-Interlocking Plugs, Receptacles, Power Inlets, and Connectors for use in Switching Applications. UL 2682 Minimum Performance Requirements for Both: Plugs, Receptacles and Connectors Similar Testing to UL 1682 Heat Rise Water Ingress Endurance Dielectric Conductor Secureness Cold Impact Switching Mechanism Similar Testing to both UL 508 and UL 98 Over load - Locked Rotor AIC Short Circuit Withstand Short Circuit Make UL 2682 Devices are Plugs, Connectors, receptacles and Inlets are Approved as a Disconnecting Means for Both Motor and Branch Circuits

Hubbell s Advantage Series UL 2682 Switch- Rated Connector Spring Loaded Disconnect Button SCCR Rating of 100kA IEC 60309 Device - Color Coded by Voltage Impact Resistant Cover Arm Heavy Duty External Cord Grips Pocketed Recess for Screws Robust & Durable Valox Housing Spring-Loaded Cover Power Indicating LED Lights Permanent Labelless Markings

Newest Hubbell Disconnecting Advantage UL Listed Suitable as General Purpose Branch Circuit Disconnect NEC 430.42 Yes Yes UL Listed Suitable as: Motor Branch Circuit Disconnect NEC 430.109(A)(6) Yes Yes Yes Yes Yes Yes UL Listed as: Manual Motor Controller 430.81-430-91 Yes Yes Yes Various Disconnecting Solutions Depending On: Code Application Devices Used at the Facility Customer Preference

Making Great Connections Mating: 1. Shroud of Plug Unlocks the Shuttle 2. Shuttle Moves: Loading the Disconnect Spring Bringing Contacts Closer Together 3. When Contacts Mate: Shuttle is Locked in Place Sleeves are Energized LEDs Illuminate

Inside the Shuttle Mating: 1. Shroud of Plug Unlocks the Shuttle 2. Continuous Feed Through Ground is First to Mate 3. Neutral Followed by Phase Pin(s) Bottom Out in Sleeves 4. Shuttle Moves: Loading the Disconnect Spring Bringing Contacts Closer Together 5. When Contacts Mate: Shuttle is Locked in Place Sleeves are Energized LEDs Illuminate

Advantage in the Palm of Your Hand Similar in Size to Standard IEC Connector Robust and Durable Housing Leverage Grip Mating Many More Advantages

The NEW ADVANTAGES IEC 60309 Mating Device C1 North American: C2 All IEC 60309 Manufacturers: C3 Meltric Continuous Ground Engagement 20 HP Rating for 30A 480V Devices Power Indicating LED Lights Safety and Convenience Superior Water Ingress Protection UL Witnessed 4X, 12 and IP69k Permanent Labelless Markings

Designed to Get Clean & Stay Clean Extremely Hot 176 F High Pressure 4-6 from the device and 4 gpm at pressure of 1160 psi 1450 psi Various Angles Sprayed for 30 seconds each from 4 different angles ( 0, 30, 60 and 90 ) while the device rotates at a rate of 5 RPM

Just Add An S for Switched Catalog Numbers for 4 Wire 3Ø 480V: Connector: HBLS430C7W Receptacle: HBLS430R7W Mounts to Same Back Box as Standard Hubbell IEC Pin & Sleeve Plug: HBLS430P7W UL Witnessed IP69k & UL Type 4x, 12 Mating Plug* UV Stabilized, Impact & Corrosion Resistant Valox Lock Out / Tag Out Cord Grip Clamping Screws are on the Same Side of the Device *To Maintain IP69k Rating. Standard Pin & Sleeve Will Mate.

Applications for the Advantage Series Food Processing Everywhere You (and Competition) Sells IEC Pin & Sleeve! Motor Disconnect Manufacturing Fast Food Entertainment Quick Change Out Beverage & Bottling Dairy Conveyors Water Processing

Who, What, Where, When & Why General Equipment Connections Motor Connections Motor Controller Branch Circuit Disconnect Hubbell's IEC Pin & Sleeve Mechanical Interlock Advantage Series Wall / Column Mount Box Mount Cord Drop Wash Down HP Rating SCCR Rating (4W & 5W). Lock Out Tag Out on Line Side Highly Visible Red Handle Auxiliary Contacts Supports NFPA 70E Practices NFPA 70E Enthusiast

100% Quality Inspection 1. Clock Position Verification 2. Dielectric (HIPOT) testing between the braided terminals 3. Dielectric (HIPOT) testing between the sleeves 4. Dielectric (HIPOT) testing between the sleeves and terminals 5. Continuity Testing (Verification that Ground makes contact 1st, Neutral 2 nd and lines 3rd) 6. Insertion / Button Latching Verification 7. LED Function Verification 8. Button Release / Ejection Verification

Acknowledging the Gorilla Proprietary Configuration NO - IEC 60309-2 YES Water Ingress Protection IP69k IP67 UL Type 4X, 12 Type 4X Continuous Ground Engagement YES NO Visual Verification of Power YES NO 30A Horsepower Ratings 120V 1Ø 2 HP 1 HP 240V 1Ø 5 HP 3 HP 208V 1Ø 10 HP 5 HP 120V 3Ø 10 HP 5 HP 240V 3Ø 20 HP 10 HP 208V3Ø 30 HP 15 HP Permanent Labelless Markings Yes NO Auxiliary Contacts Amperages Available No - Not Part of IEC 60309 for 30A 30A (60A By End of Year) Yes 20A - 200A

Newest Hubbell Disconnecting Advantage Customers In Scope: Pricing: Customers Using Hubbell IEC Pin & Sleeve Potential Customers Using Competitions IEC Pin & Sleeve Converting Meltric Customers is Not Likely Comparable Pricing to Meltric If Already Using IEC Pin & Sleeve Inherent Savings Since Buying Female Device Only Technically No IEC 60309 Competition New Quote Group A-44 No Quote Group Discounting Action Items: Call on All IEC Pin & Sleeve Users Educate People on UL2682 Qualify Your Customers to Determine Their Disconnecting Needs & Preference Do Not Forget the Value of Mechanical Interlocks

Final Exam: The Big Question??? Does Yes: Both are UL 2682 Switch-Rated Connections Approved as Motor Disconnect & Branch Disconnect No Because the Hubbell Device Has: IEC 60309-2 Compatibility Not a Proprietary Configuration Superior HP Ratings Continuous Ground Pin Engagement Improved Water Ingress Protection Power Indicating LED Lights Labelless Markings

A Time and Place for Everything Hubbell's IEC Pin & Sleeve Mechanical Interlock Advantage Series Supports NFPA 70E Servicing Practices Yes Yes Yes Motor Controller No Yes No Motor Disconnect Yes Yes Yes Branch Disconnect No No Yes SCCR NA 65Ka 100Ka H.P. Rating 30A 480V 3Ø 7½ 15 20 Water Ingress IP67 IP67 Type 4X & IP69k Visual Verification of Power No Yes Yes Lock Out Tag Out On Plug Yes On Plug Auxiliary Contacts No Yes No Horsepower Rated Pin & Sleeve Devices are an Approved Disconnecting Means for Motor Circuits

Line of Sight Disconnecting Means Supports NFPA 70E Servicing Practices IEC 60309-2 Safe Intermatability UL Listed as Manual Motor Controller NEC 430.81-430-91 UL Listed Suitable as Motor Circuit Disconnect NEC 430.102(B) UL Listed Suitable as Branch Circuit Disconnect NEC 430.2 Hubbell's IEC Pin & Sleeve Motor Disconnect MotorQuick Mechanical Interlock Fused Mechanical Interlock Advantage Series Yes Yes Yes Yes Yes Yes Yes NA NA Yes Yes Yes No Yes Yes Yes No No Yes Yes Yes Yes Yes Yes No No No No Yes Yes SCCR NA 65Ka 65Ka 65Ka 200kA 100Ka H.P. Rating 30A 480V 3Ø 7½ 15 15 15 15 20 Water Ingress IP67 Type 4X & IP69k Type 4X & IP69k IP67 IP67 Type 4X & IP69k Labelless Markings Yes Yes No No No Yes Visual Verification of Power No Yes Yes Yes Yes Yes Lock Out Tag Out On Plug Yes Yes Yes Yes On Plug Auxiliary Contacts No Yes Yes Yes Yes No

Why The Advantage Advantage Series Series Switch-Rated IEC Pin & Sleeve Flexibility & Cost Savings: Intermateable with Existing installed Base of IEC 60309-2 Pin & Sleeve No Need To Buy Plug if Already Using IEC Pin & Sleeve! Certifications: UL 2682 Switch-Rated Pin & Sleeve Connections Meets NEC Requirements for both Motor & Branch Disconnecting Superior Ratings: HP Rating Up to 30HP at 480V SCCR Rating of 100kA Water ingress Ratings of UL Witnessed IP69k and UL Type 4X, 12