MODBUS MASTER ALERTING SMS MODEM V1.50

Similar documents
MODEM for REMOTE SWITCH CONTROL V1.20

GSM Interfacing Board

Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols

RM6000 GPRS Modem / Router

AB300-Series Automated Filter Wheels

IO64 User's Manual. Rev C. Document

User Manual for VE GSM Modem

USB/RS232 TO cctalk COMMUNICATION BOARD Technical Information

Bluetooth TO Serial CONVERTER E-P132-B

JVA SMS Gateway User Manual

UCM 94/1 3G/GPRS Modem for RTU32 Series

HARDWARE MANUAL MMS100. M-BUS TO MODBUS GATEWAY Series 07 / 2017 MIKRODEV_HM_MMS100_EN

SMS Commander Manual

GW-7228 J1939/Modbus RTU Slave Gateway

GTM-204M-4G Industrial 4G LTE Modem User s Manual V1.0 High Quality, Industrial Data Acquisition, and Control Products

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE

USER MANUAL FOR FIOA-0402-U-16

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

Offer Matrix. Offer Period: 22nd Dec 18 to 5th Jan 19. End User Pay. End User Pay. Offer Option 2. Category Offer Option 1.

USER MANUAL FOR GS100/GS1003G

Industrial Quad-band GPRS/GSM Modem GTM-201 Series. User Manual

OZONE SWITCH Model OS-6. OS-6 Features

3 Input Multiplexer Operation Manual

Hardware Manual RM CANview

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

GC 055. GSM Remote Monitoring. Operating and installation instructions

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

GNS-MC35iT, GNS-MC35iU Terminals datasheet

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

Industrial Tri-band 3G Modem GTM-201-3GWA Series. User Manual

SOFTWARE VERSION 3.3. CD P/N Rev. C

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

Technical Manual for RTCU M10 / M10G

InLinK HM Setup Software Installation & Operation Manual

DCM Digital Control Modules

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

EverPump Wireless Pump control system

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

PLA User. WARNING: read connection information(p5) before connecting PL controllers to the PLA

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter.

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

1550-N2 Revision 1.7 A-B Drives Protocol Interface September 1999

EDW-ML8021 GSM GPRS Modem User s Manual. Page 1

ES-600 Ozone Controller Operation Manual

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

WARRANTY & LIMITATION OF LIABILITY

User manual Compact Web PLC WP240 series IEC-line. update:

Introduction SIM Installation Configuration Unit Installation VEHICLE TRACKING UNIT 86VT. User s Manual.

Rev. A. ANC Series RS-485/RS-422 Synchronous Clock Display. Antona Corporation (818) URL:

WARRANTY & LIMITATION OF LIABILITY

QUADIMODO. Quad-Band IP68 GSM MODEM. Quad Band for Worldwide Use. IP68 Enclosure Submersible. Voice / Fax / SMS and Data. GPRS Class B Class 10:

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Hybrid AC Driver [GCNC-1110]

MEC-COM-M114. User s Manual

Wireless Doorphone Intercom

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

Product description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS

StarFinder Aire User Manual

GPRS/SerialGateway. GPRS/Serial Gateway. User Manual

Trillium US Inc. E1000 Dual Channel Temperature Monitor / Water Pump Controller User s Manual Rev A / March 2016

INTMOD485-LH Protocol Converter

Gateway Module Programmable in C

OnCell G3100 Series Quick Installation Guide

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

INSTRUCTION MANUAL FOR MODEL IOC537 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE

1550 MBS. User Manual. Modbus Protocol Interface Communications Interface for 1336 Adjustable Frequency AC Drive

Thermoelectric Cooler Controller TED1000

Metacom SCADA Communications Systems. Metacom MC402 Remote Router. Installation Manual V2.0

PCM-7140 Pulsed Current Source Operation Manual

Clockaudio ARM-C Control Box Instructions

Intelligent Devices IDI 1100 Series Technical Manual

Industrial RFID Reader

A1000 GSM ALARM DEVICE

MEC-COM-M154. User s Manual

User's Manual PLC09 Modbus Converter for PAL-AT Leak Detection System

Serial to Ethernet Converter HL-SE02P-V1. User s Manual V3.606

Model OI x22 ProSafe

PC 150. Digital Bench Scale. Operation Manual

PACSystems* RX3i IC695CMM002 and IC695CMM004

HI GSM Supervisor. Instruction Manual

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

A1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1

DOLXFD1000B. Waterproof Access Control/Reader

RemoteTRAK RS485 Distributed I/O for Modbus and Sixnet Systems

The I-7530A-MR Modbus RTU to CAN Converter

TG Technical specifications

MX-1 GSM/GPRS M-BUS DATA LOGGER USER MANUAL

Installation and Programming Manual

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

1. Overview Technical Specifications Applications Pin Description Connection Diagram of RS 485 / 422 Converter...

Development KIT for TM2 GPRS modem User manual 1.2. Development KIT. Development KIT for TM2 GSM/GPRS modem User s manual 1.2

User Manual (Version 2.0T)

Eagle PT-MP1 Pan Tilt Communications Multiplexer Installation and Operations Manual Revision 3.0 August 20, 2001

APPLICATION NOTE. Using the SUTRON RADAR LEVEL CONTROLLER (RLR ) with a MULTIMODEM GPRS (Wireless Modem MTCBA-G-F4)

I/O SIGNAL CONDITIONER

DIN Rail RTU 540CMD01 Data sheet

Transcription:

User manual MODBUS MASTER ALERTING SMS MODEM V1.50 UASAGE NOTICE This software / document / material are property of Kurolikar Automation Research Labs (KARL PL) Pvt Ltd. It has been provided for the exclusive use of customers for the products of KARL PL. It must not be copied, saved or duplicated in full or in part in any form without the written permission of KARL PL. Unauthorized copying, duplication or reproduction of this material is restricted and may attract severe legal penalties. The specifications and features mentioned in this document are available at the time this document was prepared. Utmost care has been taken to maintain accuracy and consistency of the information. However KARL PL does not guarantee this document to be free from errors and use of the information is at sole responsibility of the user. KARL PL reserves the right to change or modify this document at any time without prior notice. 1

INDEX 1. INTRODUCTION a. GSM / GPRS features b. Alerting features c. Applications d. Specifications e. Connection pin-out f. Application diagram 2. DEVICE CONFIGURATION a. Configuration commands 3. APPENDIX a. Troubleshooting notes b. Warranty statement 2

INTRODUCTION Product: MODBUS Master alerting SMS modem Data collection interface: MODBUS communication over RS232 or RS485 Data output: Plain text SMS alert This modem is designed to interface with any standard MODBUS RTU device that want to send SMS. In typical PLC applications, situations such as failure of particular component or out of normal situation needs to intimated to someone who can take corrective action. The receiver can even be a SMS receiving modem that can operate a switch to control the situation without involvement of human. In so far applications, interfacing a standard GSM modem to PLC requires writing specific AT commands in PLC. Writing vast variety of messages along with AT commands and interfacing all those over serial port may not be an easy task for an ordinary programmer. The MODBUS master modem does the job for you. The MODBUS modem reads specific register from PLC and triggers SMS for the message code present in that register. The SMS is sent only when a new code is detected. For idle situation, a 0 message code can be kept in register. Modem stores up to 150 different messages along with their message code. For every message triggered, a total of up to 15 numbers can receive SMS. Each of the message can be separately enabled or disabled. Similarly, any particular SMS receiver can be enabled or disabled. The modem has one master number configured in it. The master can modify any or all of the configuration settings of modem from the mobile phone only. In addition, a configuration utility is available for initial configuration. GSM/GPRS Features: Based on Quectel quad band GSM/GPRS module. Quad band 850/900/1800/1900MHz. 3V SIM Card Slot. Works with off-the-shelf available 50E antenna. Aluminum casing with powder coating. 3

Alerting Features: Reads specified register from connected MODBUS RTU device such as PLC Up to 150 messages with massage code can be saved inside modem. Whenever message code in register matches with any of the saved message code, corresponding SMS is sent to all enabled receivers. Up to 15 receiver numbers can be configured in the modem. Each of the configured number receives the alert SMS The alert message can also include time stamp of the event that caused the SMS alert. This can be disabled if not required. Alerting criteria is fully configurable by end user. The configuration can be done from mobile phone or from configuration utility software. SMS message text and the alert receiver numbers can be set by master end user. Applications: SMS sending from PLC based SPM Alert message sending from any MODBUS RTU device Specifications: Power supply: 7.5V to 24V DC. Dimension: 80mm x 55mm x 25mm Weight: 142gm approx. Connections pin-out: Modem has D sub miniature 9 pin female connector for signal interface and 2pin phoenix two piece right angle screw terminal for power supply connections. Below are pin wise details for both these connectors. DB9 PIN SIGNAL NAME (RS485) SIGNAL NAME (RS232) 1 NC NC 2 RS485 TX (B) TXD 3 RS485 TX+ (A) RXD 4 NC 5 GND 6 NC 7 NC 4

8 NC 9 NC case Connected to Ground Table Terminology NC: No internal connection. GND: Supply negative Warning: Wrong connection or over voltage at any of the D type serial connector pin may permanently damage the modem. Application Diagram: 5

DEVICE CONFIGURATION Modbus master modem is fully configurable using SMS. Each setting that needs to be changed can be configured using a simple text SMS from a predefined number. The configuration commands are entertained from an authorized number only. Any configuration command received from unknown number is discarded. Configuration is a onetime process and all the setting information is saved in modem permanently Configuration commands a. Setting master user mobile number: Service engineer can set master user number using following SMS command. Master user can set or modify all settings except service provider number. SET<space>MASTER<space><mobile number> e.g. SET MASTER 7588623994 b. Setting receiver mobile number: Receiver is any user who will receive the alert message for any digital input trigger. If the receiver is enabled then it receives alert message input is triggered. Receiver cannot change any settings of modem. Maximum 15 different receiver numbers can be set. Receiver number is set using following SMS command. Here sequence number is location of internal table where the setting will be saved. There are to 15 locations in to store up to 15 different receivers. SET<space>RECEIVER<space><receiver sequence number>,<receiver mobile number> e.g. SET RECEIVER 1,7588623994 Here mobile number 7588623994 is set as first receiver number. c. Enabling receiver number: The receiver number which is set, can be enabled by using following SMS command. 6

ENABLE<space>RECEIVER<space><receiver sequence number> e.g. ENABLE RECEIVER 4 Here receiver 4 is enabled which receives alert messages, when input is triggered. d. Disabling receiver number: The receiver number which is already set, if don't want alert messages then it can be disabled. Receiver number is disabled using following SMS command. DISABLE<space>RECEIVER<space><receiver sequence number> e.g. DISABLE RECEIVER 4 Here receiver 4 is disabled which will not receive alert messages. e. Setting RTC Time This is optional feature. This command will work only if your product model supports it. Time and date stamp appears in data string transmitted to server. User can set time and date using following SMS command. Since the command is being issued using SMS, the time at which it gets delivered to modem is not guaranteed. Hence the accuracy of time being set in modem cannot be guaranteed. It is recommended to consider this delay approximately while issuing this command. SET<space>TIME<space><DD/MM/YYYY><space><HH:MM:SS> e.g. SET TIME 29/09/2016 17:11:00 Note: Single space cannot be replaced by multiple spaces. Specified time is in 24hour format f. Enable RTC This command is used to make date and timestamp appear in message string sent to receiver. RTC<space>ENABLE g. Disable RTC This command is used to make date and timestamp disappear in message string sent to receiver. 7

RTC<space>DISABLE h. Setting RTU information This command is used to set the RTU information. SET<space>RTUINFO<space><RTUID>,<REGISTER ADDRESS>,<FUNCTION CODE> e.g SET RTUINFO 1,3220,02 RTUID MODBUS RTU ID of connected device such as PLC REGISTER ADDRESS Register where the message code will be available. FUNCTION CODE MODBUS function code most typically 3 or 4 i. Setting default message Whenever a message code that is not available in message table, modem sends default message to receiver. This default message is set using following command. SET<space>DEFAULTMSG<space>DEFAULT MESSAGE e.g SET DEFAULTMSG FAULT DUE TO DRY RUN j. Clearing the table This command is used to clear all the messages which is stored in message table. TABLE<space>CLAR<space> e.g TABLE CLEAR k. Find empty row in a table This command is to find the next available empty row in a table. If user set the messages from 1 to 30 then using this command it shows the empty row is 031 so user can set the next message in next free row e.g. FIND EMPTYROW Reply: NEXT AVAILABLE EMPTY ROW IS AT 031 8

l. Setting message string Custom message can be set by following SMS command. SET<space>MESSAGE<space>ROW NUMBER,MESSAGE CODE,MESSAGETEXT e.g SET MESSAGE 1,45,FAULT 45 DUE TO LOCATOR MALFUNCTION m. Enable message code The message which is set, can be enabled a message code by using following SMS command. ENABLE<space>MSGCODE<space><Message code> e.g. ENABLE MSGCODE 22 n. Disable message code The message which is set, can be disabled a message code by using following SMS command. DISABLE<space>MSGCODE<space><Message code> e.g. DISABLE MSGCODE 22 o. Search message code The message which is set, can be search a message code by using following SMS command. SEARCH<space>MSGCODE<space><Message code> e.g. SEARCH MSGCODE 22 Reply: p. Changing baud rate of modbus communication This command can be used for changing the communication speed over Modbus interface. It is required that all the devices connected over RS485 bus support the communication baud specified here. Hence make sure to select setting which is also supported by other devices. SET<space>BAUD<space><Desired baud rate> 9

Note: e.g SET BAUD 19200 Supported baud rate are 2400, 4800, 9600, 19200, 38400 and 57600. Factory default setting is 9600 q. Setting parity of modbus communication This command can be used for changing the parity of communication over Modbus interface. It is required that all the devices connected over RS485 bus support the same parity selected here. Hence make sure to select setting which is also supported by other devices. SET<space>PARITY<space><Desired parity> Note: e.g. SET PARITY EVEN Supported parity are EVEN,ODD,NONE Factory default setting is NO PARITY r. Setting resending time This command is to set the resend time of particular fault. Resend time is minimum 30 minutes to maximum 500minutes. Default setting disabled. SET<space>RESENDTIME<space><Resend time in minutes> e.g. SET RESENDTIME 30 This above command is used to resend the fault message after 30minutes. s. Setting data collection interval time Modem collects data from all configured RTU devices at specified interval. This interval is in seconds and can be configured using following command. The polling time can be as low as 200 mili seconds and up to 3000 mili seconds. Default setting for this interval is 1 seconds. SET<space>POLLINTRVL<space><Interval time in seconds> e.g. SET POLLINTRVL 500 10

APPENDIX Troubleshooting notes In normal operation, the modem s status LED blinks continuously. If the blue LED is in OFF state, the modem is in power down state. Following table provides various blink rates of LED for different situations. LED STATUS MODEM STATUS OFF 64mSec on / 800mSec off 64mSec on / 2000mSec off 64mSec on / 600mSec off The modem is in power down state The modem is not synchronized with GSM network. The modem is synchronized with GSM network and is working normally. GPRS data transfer is ongoing In case of GPRS data communication, modem requires considerable power during actual data transmission. Hence power supply is critical for reliable data communication. It is strongly recommended to use an industry grade power supply (SMPS) of at least 2Amp current rating for powering the modem. Also make sure that the antenna is properly connected to modem and placed at an elevated place where the modem can receive strong signal for communication. Some more troubleshooting points are mentioned below. Symptom: Modem not working at all Reason: Check power supply. In many cases, bad power supply is main reason for modem to malfunction. Required power supply specifications are mentioned in relevant sections above. Make sure the modem has been connected with proper power supply with proper polarity. Symptom: Modem powered on but not responding to any SMS queries 11

Reason: Check modem without connecting any device on bus. Many times wrong bus connections make the modem receive garbage data over bus and this result in modem continuously resetting itself trying to recover from the situation. Also check if SIM card has sufficient space free to receive SMS. Check if antenna is properly connected and placed at elevated location. 12

Warranty statement Products specified in this document are covered under warranty for a period of 12 months against manufacturing defects, workmanship and malfunction under normal operating conditions. The warranty is subject to the terms and conditions mentioned below. 1. The warranty commences from the date of sale for a period of 12 months irrespective of the actual installation date. 2. The warranty is against manufacturing defects and any subsequent malfunction of the instrument during the normal operation. The warranty shall not be applicable in case of accidental damage, damage due to wrong operation, connection or conditions that are out of normal operating specifications. 3. KARL PL, at its discretion may repair or replace the product depending on the condition of instrument, availability of spare parts and type of failure. 4. In case of warranty claim, the warranty period will not be extended and remains same as stated earlier from the date of sale. 5. Maximum liability of KARL PL remains up to repair or replacement of the product only. Any damages or losses raised out of use of the instrument are not covered by this warranty. In any case, cost of the product will not be refunded. 6. In case of warranty claim, the product should be sent over to KARL PL immediately after noticing the defect or failure. A detailed note of operating conditions in which fault occurred will be helpful in rectifying the defect. 7. Do not try to open or repair the instrument on your own. Warranty will stand null and void in such case. Products with tampered warranty seal will not be considered for warranty claims and regular service charges will be applicable. 8. In all claims, the company s decision will be final and legally binding. 9. Any and all disputes are subject to pune jurisdiction only. Kurolikar Automation Research Labs Pvt Ltd #226, Laxmi colony, Behind manish market, Hadapsar, Pune 411028. www.automationresearchlabs.com Email: sales@automationresearchlabs.com 13