Discrete Output Modules IC697MDL750

Similar documents
Discrete Output Modules IC697MDL740

Discrete Output Modules IC697MDL750 24/48 Volt DC, 0.5 Amp, 32 Point Output Module

Discrete Input Modules IC697MDL653

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697BEM721. I/O Link Interface Module for the Series

PACSystems RX7i IC698CHS009/119

PLC Racks IC697CHS782/783

This Datasheet for the IC697BEM731. Series Genius I/O Bus Controller.

This Datasheet for the IC697BEM711. Bus Receiver (Required for Each Local Expansion Rack)

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

This Datasheet for the IC670MDL /24VDC 0.5A Output Pos. Logic 16 Pt. Grouped.

This Datasheet for the IC697BEM733. Series Genius Remote I/O Scanner.

This Datasheet for the IC670MDL VDC 2A Output Pos. Logic 8 Pt. Electronic Short Circuit Protect

IC693PWR331 High Capacity Power Supply, 24 VDC Input

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

Power Supplies IC697PWR724/CE697PWR724

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point

PACSystems* RX3i IC695PSA040

This Datasheet is for the IC693PWR332. High Capacity Power Supply, 12 VDC Input.

PACSystems* RX3i IC695PSA140

This Datasheet for the IC660BBD025. Block 5/12/24Vdc Sink I/O 32 Circuits.

This Datasheet is for the IC693MDL /24 Volt DC, 0.5A Positive Logic Output, 32 Point.

Allen-Bradley Drives

Power Supplies IC697PWR710/712

This Datasheet for the IC697CMM741. Series MMS or TCP/IP Ethernet LAN Interface.

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

Installation Instructions

This Datasheet for the IC660BBR100. Block Relay Output Normally Closed 16 Circuits.

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

Installation Instructions

Relay Contact Output Modules

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

PACSystems RX3i IC695PSA140

CONTROL MICROSYSTEMS Analog Input Module. Hardware Manual

CONTROL MICROSYSTEMS Differential Analog Input Module. Hardware Manual

24 Input/8 Output AC Block I/O Module

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels.

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

Accessories IC690ACC900

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

78 Series Electromechanical Relay Selection Guide

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

Installation Instructions

H3C S12500 Routing Switch Series

Allen-Bradley Drives. Instructions. (For 6180 Industrial Computers)

INSTALLATION INSTRUCTIONS Model VCC2002-A1 Voice input/output Card

Digital ac/dc (24V) Input Module

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

Replacing the Power Supply

Programmable Controller IC697ACC721/724/744

Installation Instructions

Installation Instructions

This Datasheet for the IC697CMM711. Communications Coprocessor, CMM, RTU, SNP, and SNPx Protocols

IIM Warwick Court. Williamsburg VA REV 5

Technical Manual SMART TRAC PS Card

This Datasheet for the IC670MDL VAC 16 Pt. Input Grouped.

Installation Instructions

5401 and 5402 Digital I/O Modules

Installation Instructions

Site Preparation CHAPTER

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

This Datasheet for the IC670MDL VAC 8 Pt. Isolated Input.

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V

NUV300 Datasheet. Nuvation BMS Low-Voltage Battery Controller , Rev Copyright 2018, Nuvation Energy

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

Answers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process

TABLE OF CONTENTS 1. OVERVIEW... 1

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

SERIES SIX PROGRAMMABLE CONTROLLERS

SECTION PANEL WORK

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

DC561, digital input/output module,

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

CONTROL MICROSYSTEMS and 5404 Digital Input Module. Hardware Manual

SECTION VARIABLE FREQUENCY MOTOR CONTROLLERS (VFD)

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 0-20mA Sourcing Analog In/ Out HE800MIX906 / HE-MIX906* * HE- denotes plastic case.

TRC-190 User s Manual

GE Fanuc Automation. Series I/O Processor Module. User s Manual. Programmable Control Products

Installing and Removing SDRAM and DRAM

SNAP Digital Output Modules. SNAP Digital Output Modules. Features. Description

DX561 Digital Input/Output Module

DC562, digital input/output module,

Analog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules

Installing the IPS 4345 and IPS 4360

Advantages of a Full Featured 700 Series Relay

PLC CPUs IC697CPU MHz, 32-Bit, Expandable, Floating Point Central Processing Unit

PGR-2601 MANUAL DC GROUND-FAULT RELAY

CS7 Industrial Control Relays

Installing the Cisco AS5400XM Universal Gateway

PACSystems* RX3i IC695ACC650

Series Specialty PLCs

EMC Installation Guide

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

Installation Instructions

Answers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process

In-Sight 7010C/7200C/7400C

Transcription:

54 IC697MDL750 (IC697MDL750) datasheet Features 32 Points - Four isolated groups of 8 points each a44709 0.5 amp capacity per point High inrush capacity (20x rated current) Functions The 24/48 Volt DC 0.5 Amp Output Module for the Programmable Logic Controller (PLC) provides 32 output points in four isolated groups of 8 points each. This output module provides a high degree of inrush current which makes the outputs suitable for a wide range of loads which have such characteristics. LED indicators which give the ON-OFF status of each point on the logic (PLC) side of the circuit are located together at the top of the module. The module is mechanically keyed to ensure correct replacement with a similar type in the field. I/O references are user configurable without the use of jumpers or DIP switches on the module. Configuration is done using the configuration function of the MS-DOS or Windows programming software running on Windows 95 or Windows NT over Ethernet TCP/IP or through the SNP port. The Programming Software configuration function is installed on the programming device. The programming device can be an IBM XT, AT, PS/2 or compatible Personal Computer. B2 B4 B6 B8 C2 C4 C6 C8 D2 D8 SLOT B2 B4 B6 B8 FUSE C2 C4 C6 C8 OUTPUT 24/48 VDC 0.5A/PT PILOT DUTY D2 D8 B2 C2 B4 C4 B6 C6 B8 C8 FUSE D2 D8 2A MAX/GRP 2 3 4 5 6 7 8 9 0 2 3 B2 4 5 B4 6 7 B6 8 9 B8 20 2 22 23 C2 24 25 C4 26 27 C6 28 29 C8 30 3 32 33 D2 34 35 36 37 38 39 D8 40 MODULE IC697MDL750 LABEL 4426758 002R0 IBM and PS/2 are registered trademarks of International Business Machines Corporation. MS-DOS, Windows, Windows 95, and Windows NT are registered trademarks of Microsoft Corporation. 54-

2 Operation of the 24/48 Volt DC 0.5 Amp Output Module TO OTHER OUTPUTS a4236 BACKPLANE SYSTEM INTERFACE LED OPTO ISOLATOR OUTPUT DRIVER COMMON LOAD MODULE FIELD CONNECTIONS Output Characteristics The 24/48 Volt DC 0.5 Amp Output Module is compatible with a wide variety of load devices, such as: Solenoids Motor starters Indicators The rating of 0.5 amp per point applies to the longterm current capacity of each point. Because of overall heat dissipation within the module, the maximum current for each group of 8 outputs is limited to 2 amperes. Each output on this module is capable of transiently conducting a surge current which is much greater than its long-term current rating. The rate at which such surges can be repeated depends on the current rating of the device and the duty cycle (percent of time the device is ON). For typical incandescent devices operating at a 50% duty cycle, the following repetition rates apply. Figure. Block Diagram for IC697MDL750 Fault Mode Selection The module can be configured from the programmer so that output points assume one of two states in response to certain operating or default conditions. Maintain existing output state Turn outputs OFF This is explained in more detail in the Programmable Controllers Reference Manual. Fusing The 24/48 VDC 0.5 Amp Output Module has no fuses. If protection is required, a fuse as specified below may be externally connected to each output point by the user. Littlefuse 32.750 (3/4 amp, 250 volt) Fast Acting Bussmann AGC-3/4 (3/4 amp, 250 volt) Fast Acting Steady-State Current (ma) 00 250 500 Repetition Rate (Hz) 5 0. 54-2

3 Module Mechanical Keying TERMINALS FIELD WIRING a4242 This module includes a mechanical key that prevents inadvertent substitution of one module type for another in a given slot. The key fits a uniquely shaped area on the board below the connector. The key is included with each module. When the module is first installed, the key latches onto the backplane center rail. When the module is extracted, the key remains in the center rail, configuring the slot to accept only identical module types. If it is necessary to change the module location in the rack after the key has been latched onto the center rail of the rack, the key can be removed by pushing it upward to unhook the latch while pulling it off the rail. It may then be reinserted onto the module and the module inserted into the rack in the desired location. Note: Only the power supply can be placed in the leftmost rack position. 2 4 6 8 0 2 4 6 8 20 3 5 7 9 3 5 7 9 2 B2 B4 B6 B8 Field Wiring The module is wired as shown in Figure 2. Since each group of eight outputs is isolated from the others, a wire from the power source to the power input terminals for each group is required (power input terminals for each group are not connected inside the module). The detachable field wiring terminal board will accept wire sizes from #22 (0.36 mm ) through #4 (2.0 mm ). Two wires may be terminated on a given lug if both wires are the same size. There is room for a bundle of forty #4 (2.0 mm 2) wires to be routed out through the terminal board cavity. The wire bundle can be secured to the terminal board by passing a cable tie through a cleat located at the lower corner of the terminal board. 22 24 26 28 30 32 34 36 38 40 23 25 27 29 3 33 35 37 39 C2 C4 C6 C8 D2 D8 Figure 2. Field Wiring Connections for IC697MDL750 54-3

4 Recommended Field Wiring Procedures The following procedures are recommended when connecting field wiring to the detachable terminal board on this input module. Module features referenced in the following procedures which are common to all IC697 I/O modules are illustrated in the following figure. JACKSCREW HINGED DOOR JACKSCREW a43855 TERMINAL BOARD CLEAT CLEAT STRAP CLEAT STRAP STRAP Figure 3. I/O Module Features. Turn off power before removing or installing terminal boards. Open the hinged door on the module to access a jackscrew which holds the terminal board securely in place. The detachable field wiring terminal board can now be removed from the module by turning the jackscrew counter-clockwise until it is fully disengaged. 2. To remove the terminal board, grasp the top of the terminal board and swing it outward. 54-4 Caution Do not use the hinged door to remove the terminal board. The hinged door could be damaged if this is done. 3. The terminal board is designed to accept wire sizes from AWG #22 (0.36 mm 2 ) through AWG #4 (2.0 mm 2 ). It is important that when using AWG #4 (2.0 mm 2 ) wire for wiring all points, that a maximum insulation diameter of.35 inch (3.43mm) not be exceeded. To ensure proper connection, two wires may be terminated on any one terminal only if both wires are the same size. 4. The terminal board is designed to accept a maximum of (40) AWG #4 (2.0 mm 2 )wires. If AWG #4 (2.0 mm 2 ) wires are to be used, then wire markers should be placed at least 8 inches (203 mm) from termination end to provide sufficient space for the hinged door to close.

5 JACKSCREW DO NOT PULL ON DOOR a43747 WIRE BUNDLE CABLE CLEAT Figure 4. Removal of I/O Terminal Board 5. After completing connections to all modules in a rack, the wire bundle must be secured. To ensure that the wire bundle is secured properly, it is recommended that a cable tie be wrapped around the wire bundle and tightly secured through the cable tie cleat located at the lower right corner of the terminal board. For extremely large wire bundles, additional cable ties should be used. 6. A door label insert is included with each module to indicate circuit wiring information and provide space to record user circuit wiring identification. A slot is provided on the hinged door to allow for insertion of this label. If the label is difficult to insert, crease the scored edge before insertion. The outside label has a color coded stripe to allow quick identification of the module voltage type (blue: low voltage; red: high voltage). 7. After field wiring is completed, the terminal board should be securely fastened to the rack by inserting the terminal board strap (attached to each module) into the small rectangular slots in the bottom card guide grill on the rack. This strap not only secures the terminal board to the rack, it also provides a way of identifying the wired terminal board with its correct mating rack slot location. 8. For adequate module ventilation, it is recommended that at least a 6 inch (52mm) clearance be allowed above and below the rack grill. Wire bundles should not obstruct the rack grill work. Removing an I/O Module The instructions below should be followed when removing an I/O modulefrom its slot in a rack. Grasp the board firmly at the top and bottom of the board cover with your thumbs on the front of the cover and your fingers on the plastic clips on the back of the cover. Squeeze the rack clips on the back of the cover with your fingers to disengage the clip from the rack rail and pull the board firmly to remove it from the backplane connector. Slide the board along the card guide and remove it from the rack. 54-5

6 Rated Voltage: Outputs per Module: Isolation: Output Voltage Range: Output Current: Output Characteristics Inrush Current: Output Voltage Drop: Response Time-On: Response Time-Off: Output Leakage: Current Required from 5V Bus: Table. Specifications for IC697MDL750 24 or 48 volts DC 32 (four groups of 8 outputs each) 500 volts - any output to backplane 500 volts between input groups 20 to 60 volts 0.5 amps maximum per point 2 amps maximum per group 0 amps maximum for 20 ms volt (2 ohms) maximum ms maximum ms maximum ma maximum 0.25 amp VME System designed to support the VME standard C. Refer to GFK-0867B, or later for product standards and general specifications. For installations requiring compliance to more stringent requirements (for example, FCC or European Union Directives), refer to Installation Requirements for Conformance to Standards. Table 2. Ordering Information Description Output Module, 24/48 VDC 0.5 Amp, 32 points Catalog Number IC697MDL750 Note: For Conformal Coat option, or Low Temperature Testing option please consult the factory for price and availability. 54-6