V03, V04 and V05 Series

Similar documents
80265 series, 3/2 Indirect solenoid actuated poppet valve

SPCH/ Big bottle blowing block

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

V88 series Redundant valve manifold systems - Semi modular 2oo2 Availability

V88 series Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Flow. Flow. N/en

Operating pressure (bar) kv factor (m 3 /h) *3)

Operating pressure (bar)

ISO*STAR (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

26360, NAMUR. Technical data

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

21023, 21025, 2/2 Direct solenoid actuated poppet valves

Series 95000, 2/2 Direct solenoid actuated poppet valve

Material Seat seal. N/en

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves

/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface

ICO3S - 2/2, 3/2 or 5/2 poppet valves Electromagnetically actuated, direct solenoid operated

6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

Operating pressure. N/en/en

G 1/2 30,5 A Brass NBR 0,8 3,

SCVA08, SCVA10, SCVA20 & SCVA32, 3/2 Solenoid actuated safety valve

Operating pressure. N/en/en

98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

Material pressure (bar) (Cv (US) kv x 1,2 Seat

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

21D Allfluid pressure switch, electromechanically actuated

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

Flow. (l/min) (ms) N/en

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

26360, 80207, 3/2, 5/2 & 5/3 Indirect solenoid actuated spool valves

Technical features. N/en

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface

97105 Inline, 3/2 & 5/2 Direct pneumatically actuated spool valves

24011 series, 3/2 Direct solenoid actuated poppet valve

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

60 series, 2/2 or 3/2 Ball valve

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

LB74G - EXCELON Modular System General purpose filter/regulator

97105 Inline direct pneumatically actuated 3/2 and 5/2 spool valves G 1/4.G1/2, 1/4 NPT 1/2 NPT

RM/28000/M, ISO cylinder Magnetic piston, single acting

B64G - Olympian Plus plug-in system Filter/regulator

97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves

98015 series, 3/2 Direct solenoid actuated poppet valve

Technical features. 12/ f. N/en

M/60100/M, Slide units Magnet piston, double acting

10 series (Pneufit) Push-in fittings Ø mm tube size, BSP threads

R./57100/M, R./57300/M, Roundline cylinder Magnetic piston, single acting

ISO*STAR - ATEX version (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

Electro-pneumatic control valves

15 and 16 Series BSP and hose fittings

PNEUFIT 10 series Push-in fittings

26230, Inline 3/2, 5/2 and 5/3 way soft seal spool valves electromagnetic actuated, indirectly controlled G 1/4, G 1/2

ISO STAR Solenoid & pilot actuated spool valves Sub-base 5/2 & 5/3, ISO #1... ISO #3

RM/92000/M, Short stroke cylinder Magnetic piston, double acting

10 series (Pneufit) Push-in fittings Ø mm O/D tube, BSP threads

VCB22, 5/2 Solenoid actuated In-line spool valves

AS-Interface Bus Control System

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

INDUSTRIAL PNEUMATICS - valves

Solenoid Valves PN16 for gas flow interception

BSP & HOSE Fittings M5, 1/8... 1

Fisher 657 and 667 Size 30i - 76i Diaphragm Actuators

3/2 5/2 SERIES 362/562

Direct solenoid and solenoid pilot operated valves

HERION SERIES Indirect solenoid actuated spool valves

How to Order. Manual override. : Non-locking push style. E: Push-turn locking lever style. Electrical entry

M3P..G/A, M3P..F/A Modulating control valves (PN16) for chilled and hot water systems

V50-53 SERIES IN-LINE VALVES

Direct solenoid and solenoid pilot operated valves

size size

Direct solenoid and solenoid pilot operated valves

Electromechanical pressure switches

For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T

Compression Fittings 34 Series Inch

Pneufit C composite and Pneufit M fittings Inch Ø 1/8... 1/2 O/D tube

pneumatic push-in fittings system LF 3000

5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Electrical Actuators

Electrical Actuators

V87 series - Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)

Digital electropneumatic Positioner for the integrated mounting on process control valves

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Pilot operated 2 port solenoid valve (general purpose valve) 100 VAC 50/60Hz 110 VAC 60Hz 200 VAC 50/60Hz 220 VAC 60Hz 12 VDC 24 VDC 48 VDC 100 VDC

Thermal Mass Flowmeter Sensyflow FMT200-D

Flowtronic D 607 Series

Pneumatic Control/Feedback

Field bus connections Link structure BDC Link structure BDC, B-design. Brochure

Pneumatic Control/Feedback

Crane Control Contactors and Relays

Remote Process Actuation Control System AirLINE PHOENIX INLINE

Linear Luminaire with LED Series 6012/5

Stainless steel hygienic butterfly valves. F250 for imperial tubing. F251 for metric tubing.

MPreC - Pressure Relief Device Order specification sheet

Pneumatic positioning module contiuous kpa output signal, with manual operation

Compact Bellows Pumps

Transcription:

V03, V04 and V05 Series / and 3/ Poppet Valves Electrically Actuated G 1 8, G 1 4, CNOMO and Interface Extensive range of power and orifice size options Removable coil Manifold rail for 1 to 0 valves Operating pressure range 0 to 16 bar Exhaust diffuser supplied as standard Normally closed and normally open types Technical Data Medium: Compressed air, filtered, lubricated or non-lubricated. Operation: Poppet valve, directly actuated with spring return. Mounting: Through holes in sub-base, threaded on single station. Port Size: G 1 8, G 1 4 or 3mm (0.1in) (CNOMO and Interface) Operating Pressure: Up to 16 bar (3 psig). See table overleaf. Orifice Sizes: 1,0; 1,5;,0;,5; and 3,0 mm (0.04; 0.06; 0.08; 0.1 and 0.1in). See table overleaf. Flow: See details on page 5.4.04.03 Operating Temperature: -30 C to +90 C (- F to +194 F)* supply air -30 C* to + 50 C ambient (- F to +1 F)* * Consult our Technical Service for use below + C (35.6 F) Response Times: 8-15 ms Materials: Glass reinforced thermoplastic encapsulated coil, stainless iron armature, stainless steel tube and spring, zinc alloy (G 1 8 and CNOMO) or brass (G 1 4) or polyester (interface base), nitrile rubber seals. Ordering Information To order, quote model number as indicated in the tables overleaf, e.g. V04X486L B63A for the 3/ model with an interface base, a mm (0.08in) orifice and a 4,5 W, 4 V d.c. coil without plug. Coils can also be supplied, quote reference from table overleaf inserting the voltage code where marked*. 3 1 1 1 For your local Norgren Technical Sales Centre phone 0345 6666. For your local Norgren Distributor phone 0345 7777. IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS13 6SB N/UK 5.4.04.01

General Information V03 Symbol Model Type Base Orifice Maximum Operating Weight Coil Assembly mm (inch) Pressure bar (psig) kg (lb) without terminal box V03X86J B613A Normally Closed Interface 1,0 (0.04) (145) 0,0 (0.44) V03X86A Q113 1 V03A86J B613A Normally Closed G 1 8 1,0 (0.04) (145) 0,4 (0.53) V03X86A Q113 1 V03X486J B613A Normally Closed Interface 1,0 (0.04) (145) 0,0 (0.44) V03X86A Q113 V03X486K B613A Normally Closed Interface 1,5 (0.06) 4 (58) 0,0 (0.44) V03X86A Q113 V03A486J B613A Normally Closed G 1 8 1,0 (0.04) (145) 0,4 (0.53) V03X86A Q113 1 3 1 V03A486K B613A Normally Closed G 1 8 1,5 (0.06) 4 (58) 0,4 (0.53) V03X86A Q113 V03Y486J B613A Normally Closed CNOMO 1,0 (0.04) (145) 0,30 (0.66) V03X86A Q113 V03Y486K B613A Normally Closed CNOMO 1,5 (0.06) 4 (58) 0,30 (0.66) V03X86A Q113 V03X386J B613A Normally Open Interface 1,0 (0.04) (145) 0,0 (0.44) V03X86A Q113 V03X386K B613A Normally Open Interface 1,5 (0.06) 4 (58) 0,0 (0.44) V03X86A Q113 1 V03A386J B613A Normally Open G 1 8 1,0 (0.04) (145) 0,4 (0.53) V03X86A Q113 1 3 V03A386K B613A Normally Open G 1 8 1,5 (0.06) 4 (58) 0,4 (0.53) V03X86A Q113 V04 Symbol Model Type Base Orifice Maximum Operating Weight Coil Assembly mm (inch) Pressure bar (psig) kg (lb) without terminal box V04X86K B6*A Normally Closed Interface 1,5 (0.06) 16 (3) 0,0 (0.44) V04X86A Q1* V04X86L B6*A Normally Closed Interface,0 (0.08) 16 (3) 0,0 (0.44) V04X86A Q1* V04X86M B6*A Normally Closed Interface,5 (0.1) 14 (03) 0,0 (0.44) V04X86A Q1* V04A86K B6*A Normally Closed G 1 8 1,5 (0.06) 16 (3) 0,4 (0.53) V04X86A Q1* 1 V04A86L B6*A Normally Closed G 1 8,0 (0.08) 16 (3) 0,4 (0.53) V04X86A Q1* 1 V04A86M B6*A Normally Closed G 1 8,5 (0.1) 14 (03) 0,4 (0.53) V04X86A Q1* V04B86L B4*A Normally Closed G 1 4,0 (0.08) 16 (3) 0,3 (0.71) V04X86A Q1* V04B86M B4*A Normally Closed G 1 4,5 (0.1) 14 (03) 0,3 (0.71) V04X86A Q1* V04B86N B4*A Normally Closed G 1 4 3,0 (0.1) 7 () 0,3 (0.71) V04X86A Q1* V04X486J B6*A Normally Closed Interface 1,0 (0.04) 16 (3) 0,0 (0.44) V04X86A Q1* V04X486K B6*A Normally Closed Interface 1,5 (0.06) 14 (03) 0,0 (0.44) V04X86A Q1* V04X486L B6*A Normally Closed Interface,0 (0.08) (145) 0,0 (0.44) V04X86A Q1* V04X486M B6*A Normally Closed Interface,5 (0.1) 4 (58) 0,0 (0.44) V04X86A Q1* V04A486J B6*A Normally Closed G 1 8 1,0 (0.04) 16 (3) 0,4 (0.53) V04X86A Q1* 1 V04A486K B6*A Normally Closed G 1 8 1,5 (0.06) 14 (03) 0,4 (0.53) V04X86A Q1* 3 1 V04A486L B6*A Normally Closed G 1 8,0 (0.08) (145) 0,4 (0.53) V04X86A Q1* V04A486M B6*A Normally Closed G 1 8,5 (0.1) 4 (58) 0,4 (0.53) V04X86A Q1* V04Y486K B6*A Normally Closed CNOMO 1,5 (0.06) 14 (03) 0,30 (0.66) V04X86A Q1* V04Y486L B6*A Normally Closed CNOMO,0 (0.08) (145) 0,30 (0.66) V04X86A Q1* V04Y486M B6*A Normally Closed CNOMO,5 (0.1) 4 (58) 0,30 (0.66) V04X86A Q1* V04X386J B6*A Normally Open Interface 1,0 (0.04) 16 (3) 0,0 (0.44) V04X86A Q1* V04X386K B6*A Normally Open Interface 1,5 (0.06) 14 (03) 0,0 (0.44) V04X86A Q1* V04X386L B6*A Normally Open Interface,0 (0.08) (145) 0,0 (0.44) V04X86A Q1* V04X386M B6*A Normally Open Interface,5 (0.1) 4 (58) 0,0 (0.44) V04X86A Q1* 1 1 3 V04A386J B6*A Normally Open G 1 8 1,0 (0.04) 16 (3) 0,4 (0.53) V04X86A Q1* V04A386K B6*A Normally Open G 1 8 1,5 (0.06) 14 (03) 0,4 (0.53) V04X86A Q1* V04A386L B6*A Normally Open G 1 8,0 (0.08) (145) 0,4 (0.53) V04X86A Q1* V04A386M B6*A Normally Open G 1 8,5 (0.1) 4 (58) 0,4 (0.53) V04X86A Q1* *Insert voltage code from Voltage Codes table page 5.4.04.03. All models are available without manual override. Change th digit to 1 e.g. V03X486J B11*A. CNOMO versions are available with a push to operate spring return manual override. Change th digit to 3 e.g. V03X486J B31*A. Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such a failure. System designers must provide a warning to end users in the system instruction manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable. N/UK 5.4.04.0 For your local Norgren Technical Sales Centre phone 0345 6666. For your local Norgren Distributor phone 0345 7777. IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS13 6SB

V05 Symbol Model Type Base Orifice Maximum Operating Weight Coil Assembly mm (inch) Pressure bar (psig) kg (lb) without plug V05X86M B63*A Normally Closed Interface,5 (0.1) 16 (3) 0,0 (0.44) V05X86A Q13* V05A86M B63*A Normally Closed G 1 8,5 (0.1) 16 (3) 0,4 (0.53) V05X86A Q13* 1 1 V05B86M B43*A Normally Closed G 1 4,5 (0.1) 16 (3) 0,3 (0.71) V05X86A Q13* V05B86N B43*A Normally Closed G 1 4 3,0 (0.1) 13 (189) 0,3 (0.71) V05X86A Q13* V05X486K B63*A Normally Closed Interface 1,5 (0.06) 16 (3) 0,0 (0.44) V05X86A Q13* V05X486L B63*A Normally Closed Interface,0 (0.08) 16 (3) 0,0 (0.44) V05X86A Q13* V05X486M B63*A Normally Closed Interface,5 (0.1) (145) 0,0 (0.44) V05X86A Q13* V05A486K B63*A Normally Closed G 1 8 1,5 (0.06) 16 (3) 0,4 (0.53) V05X86A Q13* V05A486L B63*A Normally Closed G 1 8,0 (0.08) 16 (3) 0,4 (0.53) V05X86A Q13* V05A486M B63*A Normally Closed G 1 8,5 (0.1) (145) 0,4 (0.53) V05X86A Q13* 1 V05B486L B43*A Normally Closed G 1 4,0 (0.08) 16 (3) 0,4 (0.53) V05X86A Q13* 3 1 V05B486M B43*A Normally Closed G 1 4,5 (0.1) (145) 0,4 (0.53) V05X86A Q13* V05Y486K B63*A Normally Closed CNOMO 1,5 (0.06) 16 (3) 0,30 (0.66) V05X86A Q13* V05Y486L B63*A Normally Closed CNOMO,0 (0.08) 16 (3) 0,30 (0.66) V05X86A Q13* V05Y486M B63*A Normally Closed CNOMO,5 (0.1) (145) 0,30 (0.66) V05X86A Q13* V05X386K B63*A Normally Open Interface 1,5 (0.06) 16 (3) 0,0 (0.44) V05X86A Q13* V05X386L B63*A Normally Open Interface,0 (0.08) 16 (3) 0,0 (0.44) V05X86A Q13* V05X386M B63*A Normally Open Interface,5 (0.1) (145) 0,0 (0.44) V05X86A Q13* 1 V05A386K B63*A Normally Open G 1 8 1,5 (0.06) 16 (3) 0,4 (0.53) V05X86A Q13* 1 3 V05A386L B63*A Normally Open G 1 8,0 (0.08) 16 (3) 0,4 (0.53) V05X86A Q13* V05A386M B63*A Normally Open G 1 8,5 (0.1) (145) 0,4 (0.53) V05X86A Q13* *Insert voltage code from Voltage Codes table page 5.4.04.03. All models are available without manual override. Change th digit to 1 e.g. V03X486J B11*A. CNOMO versions are available with a push to operate spring return manual override. Change th digit to 3 e.g. V03X486J B31*A. Valve and Base Options Family 7mm Interface Mounted Valve G 1 8 Valve G 1 4 Valve CNOMO Mounted Valve Fixed Length Manifold Manifold/Valve Assemblies V03 V03X V03A V03B V03Y M/P35598/ V03X 86 -H613A # V04 V04X V04A V04B V04Y M/P35598/ VO4X 86 -H6*A # V05 V05X V05A V05B V05Y M/P35598/ VO5X 86 -H63*A # *Insert Voltage Code from table below Insert number of stations * Voltage Codes Voltage Codes 6 V d.c. 1 1 V d.c. 4 V d.c. 3 48 V d.c. 5 1 V d.c. 7 4 V 50/60 Hz 4 48 V 50/60 Hz 6 1 V 50/60 Hz 8 0 40 V 50/60 Hz 9 Technical Details Voltage Tolerance: ±% Inrush/Hold V03 d.c. 1,0 W VO4 d.c. 4,5 W a.c. 14/ VA VO5 d.c. 9,0 W a.c. 7/0 VA 0% E.D. Plug: A variety of plugs are available, see Section 7.7.001 Manual Override Screwdriver operated, memory type, standard Protection Class: IP 65 (DIN 40 050) with terminal box fitted Note: The V03 models are only available with the 4 V d.c. coil. Flow Characteristics Inlet Orifice C b l/min A Cv Kv Ømm (inch) 1 (0.04) 0,15 0,61 39,4 0,95 0,04 0,03 1,5 (0.06) 0,30 0,36 68,95 1,6 0,07 0,06 (0.08) 0,57 0,30 137,9,36 0,14 0,1,5 (0.1) 0,77 0,30 187,15 3,05 0,19 0,16 3,0 (0.1) 1,16 0,49 75,8 6,5 0,8 0,4 The above figures are based on valves mounted on a G 1 8 base. They are typical of all base styles as the orifice diameter is the limiting factor. N/UK 5.4.04.03 For your local Norgren Technical Sales Centre phone 0345 6666. For your local Norgren Distributor phone 0345 7777. IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS13 6SB

Model Codes V 0 8 6 - B Family VO3 3 VO4 4 VO5 5 Base Type Interface CNOMO G 1 /8 G 1 /4 X Y A B Function / Normally closed 3/ Normally open 3 3/ Normally closed 4 Solenoid operator All Valves 8 Spring return All Valves 6 Inlet Orifice mm (inch) 1,0 (0.04) (Interface, CNOMO) J 1,5 (0.06) (Interface, CNOMO, G 1 /8) K,0 (0.08) (Interface, CNOMO, G 1 /8, G 1 /4) L,5 (0.1) (Interface, CNOMO, G 1 /8, G 1 /4) M 3,0 (0.1) (G 1 /4) N V03X, V04X and V05X Models Interface Mounted Valves * Not available on G 1 4 Plug None Standard, with Pg9 cable gland Indicator, with Pg9 cable gland Voltage code See Voltage Code table on page 3 Power 1W (VO3 models only) 1 4,5W (VO4 models only) 9W (VO5 models only) 3 Manual Operator None 1 Push to operate spring return 3* Lever, memory type 4 Screwdriver, memory type 6* Integral design All Valves Note: This table should be used for identification purposes only and not to build up model variants. V03A, V04A and V05A Models G 1 8 Valves A B G B 3 (1.6) 3 (1.6) 4 (0.94) 4 (0.94) M4 '1' G 1 /8 7 (0.8) 3 (1.6) 3 (1.6) '' G 1 /8 4 (0.94) Ø4,7 (0.19),4 (0.09) 78 (3.07) 59 (.3) 6 (0.4) 7 (0.8) '3' G 1 /8 4,5 (0.18) 37,5 (1.48) 8 (3.3) 8 (0.31) 1,5 (0.49) '3' G 1 /8 63 (.48) 6 (0.4) 40 (1.57) 69 (.7) 1,5 (0.06) 3 (1.6) 40 (1.57) 69 (.7) All dimensions in mm (inch) N/UK 5.4.04.04 For your local Norgren Technical Sales Centre phone 0345 6666. For your local Norgren Distributor phone 0345 7777. IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS13 6SB

V03B, V04B and V05B Models G 1 4 Valves V03Y, V04Y and V05Y Models CNOMO Mounted Valves 1,7 (0.50) M4 1,7 (0.50) 1 (0.83) M4 6 (0.4) Fixed Length Manifold M/P35598/* Weight = N x 0,041 Kg G 1 8 N = Number of stations * indicates the number of stations (1 0) 61 (.40) 61 (.40) ** ** M5 x 0.8 3 (1.6) '' G 1 /4 9 (3.6) 1 (0.47) '3' G 1 /8 '1' G 1 /4 7,5 (.85) 6 (0.4) 87 (3.43) 17 (0.67) 7,5 (0.30) '' '' G 1 /8 7,5 (0.30) 68 (.68) 6 (0.4) 36 (1.4) 50 (1.97) 40 (1.57) 33 (1.30) 70 (.76) 3 (1.6) '1' 1 (0.85) 69 (.7) 4 (0.94) 16 (0.63) 33 (1.30) 33 (1.30) '' G 1 /8 x 9,5 33 x (N-1)+3 (1.30 x (N-1)+1.6) N = Number of stations ** Two additional holes with five or more stations All dimensions in mm (inch) N/ UK 5.4.04.05 For your local Norgren Technical Sales Centre phone 0345 6666. For your local Norgren Distributor phone 0345 7777. IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS13 6SB

Manifold/Valve Assemblies Interface mounted valves can be supplied pre-assembled on manifolds. 61 (.40) 61 (.40) Select the basic valve required and quote the associated manifold/valve assembly model using the table below. M5 x 0.8 4 (0.94) 16 (0.63) 33 (1.30) 33 (1.30) '' G 1 /8 x 9,5 13, (0.5) 3,7 (1.9) 33 x (N-1) + 3 (1.30 x (N-1) + 1.6) G 1 /8 69 (.7) 8,6 (0.34) 17, (0.68) 59 (.3) 6 (0.4) 95 (3.74) Basic Valve Model Manifold/Valve Assembly Model V03X86J B613A V03X86J H613A # V03 V03X486J B613A V03X486J H613A # V03X486K B613A V03X486K H613A # VO4X86K B6*A VO4X86K H6*A # VO4X86L B6*A VO4X86L H6*A # VO4X86M B6*A VO4X86M H6*A # V04 VO4X486J B6*A VO4X486J H6*A # VO4X486K B6*A VO4X486K H6*A # VO4X486L B6*A VO4X486L H6*A # VO4X486M B6*A VO4X486M H6*A # VO5X86M B61*A VO5X86M H63*A # V05 VO5X486K B61*A VO5X486K H63*A # VO5X486L B61*A VO5X486L H63*A # VO5X486M B61*A VO5X486M H63*A # # Insert number of stations (1-0 stations) 1 = 1 station = station A = station B = 11 station K = 19 station L = 0 station * Insert Voltage Code from page 5.4.04.03 All dimensions in mm (inch) Options and Accessories Light Emitting Gaskets Voltage Range Model Number Power consumption 1 4 V a.c./d.c. M/P40861 0,5 W 1 V a.c./d.c. M/P40880 0,5 W 0 40 V a.c./d.c. M/P4086 0,5 W N/UK 5.4.04.06 For your local Norgren Technical Sales Centre phone 0345 6666. For your local Norgren Distributor phone 0345 7777. IMI Norgren Limited, PO Box, Eastern Avenue, Lichfield, Staffordshire WS13 6SB