EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

Similar documents
EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

EY-IO 534: I/O module, analogue inputs with galvanic isolation, modu534

I/O module, digital outputs (relays), modu550

I/O module, digital and universal inputs, modu530

I/O module, universal, digital, S0 inputs, modu533

I/O module, digital outputs (open collector), modu551

EY-EM : Remote I/O module, ecolink

I/O module, analogue outputs and universal inputs

EY-RU : Room operating unit, ecounit

modunet292: novanet-ethernet interface

EY-RU : Room operating unit, ecounit

EY-RU : Room operating unit, ecounit

Sauter Systems

EYE 200: DDC single-room controller, ecos200

EY-RU : Room operating unit, ecounit

EY-WS 500: Web server for moduweb Vision and moduweb500 BACnet networks

ProtoConvert Modbus RTU / Modbus TCP/IP / BACnet MSTP / BACnet IP / SNMP - Telnet (Lighting Controller) PG

EY-SU 358: Push-button unit for room operating unit, ecounit358

EY-RU 355: Room operating unit, ecounit355

modu : Local override and indicating units

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

Manual Industry Interfaces

EY-RC 208, 209: Room automation stations, ecos208, 209

Extension module for BACnet over Ethernet / IP and graphic Web functions

Extension module for graphic Web functions for one automation station

General Specifications. P2-SCM Serial Communications

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Extension module for Web functions generic

EY-AS 524, 525: Modular automation station, modu524/525

M-Bus Master. Data sheet. MultiPort 250D/L

M-Bus Master MultiPort 250D/L

EY-AS 524, 525: Modular automation station, modu524/525

RTU560 Connections and Settings DIN Rail RTU 560CIG10

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

mark150s mark150/485s DDC controllers Summary

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

TM221M16R controller M IO relay

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Manual Fiber Optic Interfaces

M-Bus Central Unit. Use

C-DIAS Serial Interface CSI 021

EY-AS 525: Modular automation station, modu525

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

TABLE OF CONTENTS. Communication Functions

ICF-1150 Series Quick Installation Guide

ICP PANEL-TEC PEX3000 II

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

IntesisBox Modbus Server KNX

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

RTU560 Remote Terminal Unit Connections and Settings

Modbus communication module for TCX2: AEX-MOD

MGate 4101-MB-PBS Series

Hardware Manual RM CANview

Module with RS485 communication option for

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

PCI Express 4-Port Industrial Serial I/O Cards

Appendix. Specifications

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

3.1 I-7560 Pin Assignment and Specifications: Introduction

MEV Limited USB232/485 INSTRUCTION MANUAL

User Manual A08. User Manual

Support 1 RS-232 or RS-485/422 serial port to 1 10/100Base-T(X) self-adaptive Ethernet interface

MEC-COM-M134. User s Manual

MIC-2 MKII, Multi-instrument DATA SHEET

GT- IRDM-9603 Product description Rev. 2 17/06/2014

Data Collecting Device. ProData. Operating Instructions. Dip Switches. Interface. Mode RS485- PT LON. Interface Analogue Input 0-20mA

W&T Manual Interface modules W&T

P3-SCM. General Specifications

Media Converters. Media Converters. Product Selection Guides

ME-9000i isolated Serial Interface Board, RS232, RS422, RS485

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

M-BUS Standard acc. EN AE.05:04.01: Protocol Specification

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

MIC-2 Multi-instrument DATA SHEET

TM221CE24R controller M IO relay Ethernet

MRUC-20 Modul-R CAN Bus Network

PXR11 PXR12. System controllers DESIGO PX

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

TM221ME32TK controller M IO transistor PNP Ethernet

Enron Modbus I/O Driver (Series 2) Programmable Serial Interface Card

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

GmbH, Stettiner Str. 38, D Paderborn

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

MGate 5105-MB-EIP Series

TM221CE40T controller M IO transistor PNP Ethernet

General information. Display. Supply voltage. Input current

Manual PCD2.F2xxx serial interface modules

EY-AS 521: Compact automation station, modu521

Transcription:

Product data sheet 97.012 EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721 How energy efficiency is improved SAUTER EY-modulo 5 technology: modular, fast and universal Features Part of the SAUTER EY-modulo 5 system family Pluggable element for extending the modu525 automation station (AS) Modular design (baseplate/electronics/led indicators) Direct inscription on the front Connection to non-sauter systems (PLC, chillers, meters etc.) Connection for point-to-point protocols with EIA-232 interface Connection for field bus protocols based on EIA-485 2-wire EIA-485 (half-duplex) Galvanic isolation up to 300 V Jumper for EIA-485 bus voltage, bus termination and connection for galvanic isolation One or two COM modules per modu525 AS M-Bus and further integration of third-party products with the modu525 AS for integrated control and optimised regulation and the option to use BACnet/IP communication with the management level. EY-CM721F010 Technical data Power supply Power supply from modu525 Per AS at location 1 or 2 2 COM modules Current consumption 150 ma Power loss 1.2 W Operating temperature 0...45 C Storage and transport temperature 25...70 C Admissible ambient humidity 10...85% rh, no condensation Protocol processor FPGA COM interface UART Memory Flash memory (user and protocol data) Number of data points 200 COM port, EIA-232 (DTE) D-sub connector (9-pin, male) COM port, EIA-485 6 screw terminals (2 C, 2 D+, 2 D-) Baud rate 0.3...57.6 kbit/s Ambient conditions Architecture Interfaces and communication Data bits 5, 6, 7, 8 Stop bits 1, 1.5, 2 Parity none, even, odd Connection, I/O bus 12-pin, integrated in socket Fitting on top-hat rail Dimensions W x H x D 42 170 115 mm Weight 0.8 kg Type of protection IP 20 (EN 60529) Construction Standards and directives Protection class III (EN 60730-1) Environment class 3K3 (IEC 60721) Right of amendment reserved 2014 Fr. Sauter AG 2.1 1/6

Software class A EN 60730-1 Annexe H CE conformity as per EMC directive 2004/108/EC 1) EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 Overview of types Type EY-CM721F010 EY-CM721F020 Accessories Type Protocol Communication module for Modbus/RTU (master, EIA-232 or EIA-485) Communication module for M-Bus/RTU (master, EIA-232 or EIA-485) Description 7010037001 Manual for moducom communication modules, German 7010037002 Manual for moducom communication modules, French 7010037003 Manual for moducom communication modules, English 0386301001 Connection cable COM DB9(f)-DB9(f), 3 m (null modem) Description of function Communication module (abbreviated as COM module) to integrate third-party products at automation level based on field bus protocols for EIA-232 or EIA-485 such as Modbus/RTU, M-Bus and further integration of third-party products with the modu525 automation station for integrated control and optimised regulation. Option of BACnet/IP communication on management level. Intended use This product is only suitable for the purpose intended by the manufacturer, as described in the Description of operation section. All related product documents must also be adhered to. Changing or converting the product is not admissible. Engineering notes General for moducom The configuration of the COM modules, the system protocol parameters and user-specific data point parameters is carried out with the software tools of SAUTER CASE Suite. Information regarding the exact configuration and function are described in CASE Suite (online help) and the moducom manual (7010037). Reading and writing data points is generally supported by field bus devices. BACnet's present values are written into the data point values of the third-party system or are read from the data point values of the third-party system. The following functions apply to mapping from the point of view of the AS (BACnet object): BACnet alien systems mapping AS (BACnet object) Function CM (FS data point) BI (present value) Reading Bit data point AI (present value) Reading Float data point Unsigned data point Signed data point MI (present value) Reading Unsigned data point BO (present value) BO (feedback value) Writing (reading) Bit data point (feedback) AO (present value) Writing Float data point Unsigned data point Signed data point MO (present value) MO (feedback value) Writing (reading) Unsigned data point (feedback) PC (count) Reading Unsigned data point Erroneous reading or writing can be supported with the BACnet property Reliability. When converting unsigned/signed values to or from analogue objects, the value may lose accuracy and resolution. Listening function for commissioning, monitoring, analysis, etc.: there is an AS TELNET interface (via special TELNET/TCP port) for data logging. This allows the listening data to be recorded in a legible text format (TELNET client, etc.). 1) EN 61000-6-1: EIA-232 cable max. 15 m in length; EIA-485: shielded cable 2 2 twisted pair 2/6 2.1 Right of amendment reserved 2014 Fr. Sauter AG

More detailed information on the protocols and functions can be taken from the function module description and the moducom manual (7010037). EY-CM721F010: modu721 Modbus/RTU (master) (EIA-232 or EIA-485 interface) For the Modbus/RTU (master) protocol implementation, the following Modbus function codes (fc) are supported: (R/W: Read/Write) fc1: Read Coils (R/W) Reading 1-bit values (R/W) fc2: Read Discrete Inputs (R) Reading 1-bit values (R) fc3: Read Holding Registers (R/W) Reading 16-bit values (R/W) fc4: Read Input Registers (R) Reading 16-bit values (R) fc5: Write Single Coil (R/W) Writing 1-bit value fc6: Write Single Register (R/W) Writing 16-bit value fc15: Write Multiple Coils (R/W) Writing 1-bit values fc16: Write Multiple Registers (R/W) Writing 16-bit values Other supported functions: As master only Range of slave addresses 1...247 Max. 200 objects/data points Multi-telegram addressable Telegram transmission only as RTU frame (Remote Terminal Unit frame) Restrictions the following functions are not supported: Other function codes than those mentioned are not supported, and neither is telegram transmission with Modbus/ASCII. Exception codes are also not evaluated. The following data types can be used for the master functionality: 1-bit coil, 1-bit discrete input, 16-bit holding coil, 16-bit input coil, 32-bit formats with 2x16-bit coils ( double coils ), 1-bit of a 16-bit coil. The data from the Modbus data model can be read and written over. The protocol implementation of the Modbus master can interpret the data in diverse data formats and connect it with the BACnet data objects. The following data types are supported by the Modbus master. 1-bit Boolean (8-bit signed/unsigned integer) (8-/16-/32-bit fields) 16-bit signed/unsigned integer 32-bit signed/unsigned integer 32-bit IEEE float Special Modbus master functionality With data point parameter byte order, the 32-bit data formats can be interpreted in reverse 16-bit register order. This parameter can be defined individually for each data point. Each individual bit of a 16-bit coil can also be assigned to a binary data object (BACnet BI, BO) (data point parameter: BitNo. on BitField ). ) When several BOs are used on a coil, only the most recently written bit affects the whole coil. The data point parameter Function code can be used to force single writing of coils with fc15 and execute single writing of coils with fc16. JBUS addressing (from 0 to 65535) is supported for all data model ranges (x, 1x, 3x, 4x), meaning that Modbus addresses are used with an offset of -1. EY-CM721F020: modu721 M-Bus (master) (EIA-232 or EIA-485 interface) For M-Bus protocol implementation, the following M-Bus functions are supported (in accordance with EN 1434 or EN 13757 (partially)): As master only Range of primary addresses 1...250 32-bit IEEE float Max. number of M-Bus counters is defined by the level converter Max. 200 objects/data points Data point sequence is defined by the manufacturer's description ( M-Bus Records ) Response with fixed data structure and response with variable data structure Transmission format low byte/high byte only (CI-Field = 0x72) Right of amendment reserved 2014 Fr. Sauter AG 2.1 3/6

Query of values from several memory pages (Multi-telegram counter with M-Bus Pages ) Initialisation telegram SND_NKE REQ_UD2 only Decoding of the data fields of the DIF and VIF frame part (data/value information field) Time or command-controlled retrieval of counters (battery protection) Automatic detection of M-Bus units and adaptation to SI units Restrictions the following functions are not supported: Secondary addressing and network support Broadcast telegrams Manufacturer-specific frame parts (DIF 0x0F) Frame parts such as medium, DIFE (Data Inform. Field Extension) Frame parts VIFE (Value Information Field (Extension)) The following data types are used for the master functionality: 8-, 16-, 24-, 32-, 48-, 64-bit integer 32-bit IEEE float (real) 2-, 4-, 6-, 8-, 12-digit BCD Counter readings can be converted to the 32-bit IEEE real-float format for the present value of the BACnet object. Values larger than 16,777,215 exceed the resolution of 1 and may no longer be displayed correctly. The use of the pulse-converter object with the property count as an unsigned 32 value increases the maximum counter reading (4,294,967,296). General for modu721 COM module with the following 6 or 7 LED functions: LED name I/O bus No designation Status Frequency 2) Description Continuous green light moducom mode ok ( running ) Pulsating green º º º º º º No channel configuration Rapid pulsating green ººººººººººº Device in configuration Pulsating red º º º º º º No protocol loaded in device Rapid pulsating red ºººººººººººº No communication with the AS Left Ethernet LED Flashing red Internal error LED no. Green red OFF alternating Lamp test active (indicator type priority) 1 Continuous green light Voltage 1 available at moducom 2 Not used 3 Not used 4 Not used 5 Green º º º º º º º º Specific to protocol, such as Requirement (SEND) Red º º or Specific to protocol, such as erroneous requirement (Tg error) 6 Green º º º º º º º º Specific to protocol, such as Response (RECEIVE) Red º º Specific to protocol, such as erroneous response (timeout, Tg error) COM module with a 12-bank terminal block and the following terminal assignment: Terminals Direction Designation Description 7-12 - NC Not connected 5, 6 Common C EIA-485 common (earth GND2) 3) 3, 4 Output D+ EIA-485 data line (+) 1, 2 Input D- EIA-485 data line (-) 2) pulsating: 0.1 s / 10% duty cycle, pulsating quickly: 0.1 s / 50% d.c., flashing: 0.5 s / 50% d.c., alternating: per 1 s 3) can be galvanically separated from the system earth GND1 with jumper GND 4/6 2.1 Right of amendment reserved 2014 Fr. Sauter AG

COM module with following jumpers for bus termination and bus voltage (in accordance with EIA-485, half-duplex): Jumper Resistance Designation Description Top - GND Earth GND2 connected to GND1 Top, centre 511 Ω Pulldown Jumper pulldown (D- to GND2 (earth EIA-485) with 511 Ω) Bottom, centre 511 Ω Pullup Jumper pullup (D+ to VPP2 (feed EIA-485) with 511 Ω) Bottom 121 ohms Termination Jumper line termination (D+ to D- with 121 Ω) The COM module has two interfaces: a serial interface in accordance with EIA-232 and an interface for field bus protocols in accordance with EIA-485 (half-duplex). The communication with the thirdparty system can be operated either with the EIA-232 or the EIA-485 interface. The correct connection directly to third-party devices or to an additional bus coupler (EIA-485<>EIA-485/422) for a possible higher insulation protection against disturbance voltage (galvanic or optical isolation) must be made in accordance with the standards of EIA-485. For the EIA-485 half-duplex (2-wire) wiring there is a line termination resistance (121 ohms) as well as pull-up and pull-down resistances (511 ohms) on the COM module. These resistances can be switched on or off with jumpers. All jumpers are set when the system is delivered. The station must be completely isolated from the power supply when the jumper positions are changed. The COM module electronics must be separated from the baseplate and the jumpers inside the module can then be removed or replaced. The common line should also be used. The 3 wires for the bus (C, D+, D-) should have a maximum twisted length of 1.2 km (depending on the Baud rate) (wiring recommendation: 2*2-core, twisted in pairs with shielding; 1 pair can be common with shielding). There should not be any spurs on the EIA-485 bus. The bus must be designed with linear topology. A maximum of 31 EIA-485 devices can be connected to the bus. Diverse topologies can be taken into account and can be found in the documentation of the third-party device or the optional bus coupler: 2-wire EIA-485 bus topology connected to the modu721 4-wire (full-duplex) EIA-485 devices connected to the modu721 with 2-wire bus topology 4-wire (full-duplex) EIA-485 bus topology with additional bus coupler for modu721 EIA-485 bus topology with more than 31 EIA-485 devices with additional bus amplifier Notes on these topologies are documented in the moducom manual (7010037). COM module with 9-pole D-Sub plug and following pin assignment (in accordance with DTE): PIN Direction Designation Description 1 Input DCD Data Channel Detect 2 Input RxD Receive Data 3 Output TxD Transmit Data 4 Output DTR Data Terminal Ready 5 - GND Earth 6 Input DSR Data Set Ready 7 Output RTS Ready to Send 8 Input CTS Clear to Send 9 Input RI Ring Indicator SH - GND Earth ( shield cable screening) The correct connection directly to the third-party device or to a bus coupler (EIA-232<>EIA-485/422) must be taken from the documentation of the third-party device or the bus coupler. The connection of the data pins (2/3) and pin 5 (earth) is usually sufficient. The maximum cable length of the EIA-232 line may not exceed 15 m. Burst interference greater than 1 kv may disrupt communication of the EIA-232 line. For greater distances, the EIA-485 interface should be used directly or an additional EIA-485<>EIA-232 level converter. Disposal When disposing of the product, observe the currently applicable local laws. More information on materials can be found in the Declaration on materials and the environment for this product. Right of amendment reserved 2014 Fr. Sauter AG 2.1 5/6

Wiring diagram EIA-232 EIA-232 9 pol. Sub-D (male) 1 2 3 4 5 6 7 8 9 A10616 Key 1 DCD (IN) 2 RxD (IN) 3 TxD (OUT) 4 DTR (OUT) 5 GND 6 DSR (IN) 7 RTS (OUT) 8 CTS (IN) 9 RI (IN) EIA-485 GND Pulldown Pullup Termination Key 01, 02 D- 03, 04 D+ 05, 06 Common 07-12 NC 01 03 05 07 09 11 02 04 06 08 10 12 A10617 Dimension drawing 42 115 M11435 85 170 85 Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61-695 55 55 www.sauter-controls.com 6/6 2.1 Right of amendment reserved 2014 Fr. Sauter AG