ASCO 920 Remote Control (RC) Switches

Similar documents
920 Remote Control (RC) Switches

Catalog Number Identification with Elements Explained V V V V X 347 V Hz

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

ASCO Power Transfer Load Centers. Power Switching & Controls for Business-Critical Continuity

ASCO SERIES 300 Service Entrance Power Transfer Switch

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

60103 Circuit Breaker

Series 300 POWER TRANSFER SWITCHES MAXIMUM RELIABILITY & EXCELLENT VALUE FEATURES

Application Techniques CENTERLINE 2100 Motor Control Centers

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

CS8 Industrial Control Relays

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

E-Series General Specifications

Power Switching & Controls for Business-Critical Continuity

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

TeSys IEC Contactors and Overload Relays

SECTION DISCONNECT SWITCHES

SECTION SWITCHBOARDS

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

ASCO SERIES 300 Manual Transfer Switch Solutions

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

Product Guide. UL 1077 DIN Rail Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet

Miniature Circuit Breakers and Supplementary Protectors. Contents

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Product Guide. UL 489 DIN rail miniature circuit breakers

UL 489 DIN Rail Miniature Circuit Breakers

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

Mini Contactors & Overloads

SECTION PANELBOARDS

UL 489 DIN Rail Miniature Circuit Breakers

Large Frame IEC Contactors

SECTION DISTRIBUTION SWITCHBOARDS

WMS SUPPLEMENTARY PROTECTORS

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

ALLEN BRADLEY RELAY Bulletin 700-HF

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Featuring Spectra RMS Breakers

Power Supplies V7-T6-2 V7-T6-4 V7-T6-10 V7-T6-16 V7-T6-36 V7-T6-39 V7-T6-43

Quick Start Guide TS A

APL/UPL, 205/295 Series Magnetic Circuit Protectors

Grid to Chip Surge Protection Product Catalog

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Voltage Dip-Proofing Inverter

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM>

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

The ASCO 7000 Series. Protecting data centers, hospitals, airports, retail stores and other facilities

Power-Style QED-2, Series 2 Low Voltage Switchboards

IELR Rail-Mount Series Magnetic Circuit Protectors

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

CS7 Industrial Control Relays

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Posi-Lok Plugs and Panels

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

PLC Racks IC697CHS782/783

Applying branch circuit breakers and supplementary protectors in North America

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Series 230 Automatic Transfer Switch

Bulletin 1489 Circuit Breakers. Selection Guide

Section 4 Ground-Fault Protection Devices

Micro Contactor MA Series

Bulletin 700-HA Tube Base Relay

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

IELR Series

4000 SERIES Power Transfer Switches Product Features

Bulletin 700-HL 2-Pole Terminal Block Relay

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

Voltage Current Front-mounting bracket

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

C-Series. Circuit Breaker

Installation Instructions

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

Motor protection relays

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

Site Preparation CHAPTER

Transcription:

Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities beyond the ASCO 97. ASCO 920 RC switches are available for separate mounting in NEMA type enclosures or direct mounting within lighting panelboards for total or splitbus applications. It is available from 30 through 225 Amperes per pole with 2 or 3 poles and service voltages through 600 volts AC. The ASCO 920 is listed under UL 508 for ballast lighting, tungsten, general use and resistive loads. It also meets the withstand current requirements of UL 67 for panelboard applications. The ASCO 920 is easy to install and features all position mounting, no derating for high inrush loads and a reliable single-solenoid operator. ASCO 920 RC switches can be used with energy management systems which automatically control lighting and power circuits through control devices such as photoelectric cells, microprocessors, timers and occupancy sensors. ASCO 920 Features Electrical Features UL listed. CSA Approved Meets UL 67 requirements with short-circuit rating (Withstand Current Rating) of 22,000 rms symmetrical at 480 volts for use with molded case circuit breakers; 00,000 rms symmetrical at 600 volts for use with currentlimiting fuses. Interrupts 300% of rated current at 480 volts, 0.4 to 0.5 power factor Can be used with metal halide, mercury vapor, quartz halogen, tungsten and fluorescent lighting. No derating when used on high inrush loads such as cold tungsten lamps. Wide arc gaps and arc splitters to quickly extinguish arcs. Isolated arcing chambers are widely spaced and symmetrically located. Construction Features Long life. Designed for more demanding lighting contactor use. Provides extended life and quieter operation. Suitable for use with energy management systems. Rugged molded base and cover with superior electrical insulation. Provisions for manual operation during inspection and maintenance. Lightweight for easy installation. Plug-in auxiliary control relays available. Control line terminal clamps simplify installation: Insert wire and tighten. Wire range #4 AWG to #0 AWG. Contacts are power-driven in both directions for complete dependability. No extra wires or contacts needed to install signal lamps at control stations. Can be mounted in any position. Available from stock from 30-225.

ASCO is the global leader in power switching and controls ASCO 920 Product Specifications Switch Only (Panelboard Mounting),2,3 Switch Rating Dimensions, In. (mm) Width Height Depth 30-00 50-225 7-5/6 (20) 8-5/6 (2) 7-5/6 (20) 9-/2 (24) 3-/2 (89) 3-/2 (89) Approx. Shipping Weight Lb. (kg) 6 (2.7) 7(3.2). Suitable insulation must be behind switch unit. 2. Suitable for bus bar mounting. Lugs not supplied. 3. Dimensional data is approximate and subject to change. Certified dimensions available upon request. Switch With Sub-Panel (Panelboard Mounting) 4 Switch Rating 30-00 50-225 Dimensions, In. (mm) Width Height Depth 7-5/6 (20) -3/4(298) 7-5/6 (20) 4-/2(368) 3-7/8 (98) 3-5/6(00) Approx. Shipping Weight Lb. (kg) 8(3.6) (5.0) NEMA Type Enclosure Dimensions, In. (mm) Width Height Depth 3(330) 3(330) 8-/4(464) 24(60) 4. Enclosure gutter spaces are based on non-looping of cables within the enclosure. Where cables must be looped within the enclosure, oversize cabinets are available at extra cost. Contact ASCO for complete information. Maximum Voltage Ratings at Rated, Open or Enclosed 5 When Connected When Connected 2 Poles to Load on Pole to Load and 3 Poles to Load on 3 Ballast Tungsten General Use Switch Rating 30-00 50-225 277 VAC 250 VAC 347 VAC Ballast Tungsten General Use Inrush Current Values and Minimum Recommended Control Circuit Fuse Size 6,7,8 20 Volts, 60 Hz Inrush Minimum Fuse 24 8 30 0 480 VAC 250 VAC 600 VAC 240 Volts, 60 Hz Inrush Minimum Fuse 2 4 5 5 4-/2 (4) 4-/2 (4) Approx. Shipping Weight Lb. (kg) 23(0.4) 3(4.0) 5. For DC service, maximum current rating is 75 amps or switch rating, whichever is less, with maximum voltage rating of 25 volts when connected pole to load and 250 volts when connected 2 poles to load. 277 Volts, 60 Hz Inrush Minimum Fuse 4 3 5 6. Overcurrent protective device ratings for control circuits should be selected and installed in accordance with the NEC. 7. This table shows the minimum permissible control circuit fuse size, based on the operating coil s momentary inrush current. 8. ASCO furnished control fuses are rated at 5. Wire Size for Service and Control Connections 9,0 Switch Rating 30 60-75 00 50-200 225 AL or CU Terminal Lug Wire Range AWG-MCM 4-8 2-2 4-/0 6-250 4-400 No. of Cable per Terminal Lug Connector 9. Control circuit connections are supplied with terminals accommodate a copper wire range of #4 AWG to #0 AWG. 0. Service connection for switches on sub-panels are furnished with solderless lugs to accommodate copper or aluminum wire, except on 30 Amp size which is provided with /4 studs. 480 Volts, 60 Hz Inrush 6 7 Minimum Fuse 2 3 Maximum Distance Between Control Station and One ASCO 920 RC Switch with Source Line Voltage at 90% of Normal Switch Rating 30-00 50-225 AWG No. 4 2 0 4 2 0 20 Volts, 60Hz 465 740 75 395 630 000 Distance in Feet 2,3 240 Volts, 60Hz 860 2960 4700 580 2520 4000 277 Volts, 60Hz 2480 3940 6265 200 3350 5325. If the control device does not have adequate current-carrying capacity to control the switch directly, or the control station is to be located a greater distance from the switch than is allowed in the above table, auxiliary control relays for 2-wire, or 3-wire control are available. See optional accessories on inside tab. 2. For 208 volt system, reduce 240 volt values by 5%. 3. For 265 volt system, reduce 277 volt values by 5%.

Creative, responsive, customer - focused and competitive. ASCO 920 Ordering Information Product Code No. of Poles Continuous Ampere Rating AC/DC AC Voltage Code Voltage 2 Code Sub-Panel Options Enclosures 920 2 3 30 60 75 00 50 200 225 0 to 20V 208 to 240V 265 to 277V 440 to 480V Other Voltages Up to 480 3 6 7 9 X 0 = No 3 Sub Panel = Sub-Panel Leave Blank for No Options. X Indicates Options. List Separately. See Below. Leave Blank for Open - Type. C Indicates NEMA Type, or Specify Other Type Required.. For DC service, maximum current rating is 75 or switch rating, whichever is less, with maximum voltage rating of 25 volts when connected pole to load and 250 volts when connected 2 poles to the load. 2. All at 50 or 60 Hz. For voltages other than those listed, and for DC applications, contact your nearest ASCO source. 3. Specified only when ASCO 920 is to be mounted within a panelboard. A sub-panel is required when mounting in NEMA type enclosures Example: The catalog number for an ASCO 920, 3-pole, 225-amp switch with a control coil voltage of 277 volts, 60 Hz, with an Optional Accessory 48 and a sub-panel, in a NEMA Type enclosure is: 92032257XC with option 48A(20V) Optional Accessories Option Description See Notes Specify Option ASCO 920 Remote Control Switch with sub-panel Auxiliary contacts, one normally open and one normally closed. Supplied as a pair. Rated 0 amps at 480 VAC. Fully-rated neutral plate Auxiliary control relay for 2-wire control Auxiliary control relay for 3-wire control Auxiliary control relay for Form 3 control Control line fuse: For grounded control voltage (to 300V) For ungrounded control voltage (to 300V) For ungrounded control voltage (30-600V). A maximum of one pair of optional 4A and 4B contacts can be supplied on the above indicated remote control switches. 2. The Amperage of the neutral plate will be equal to the Amperage of the specified remote control switch. Lugs capable of accommodating the same cables as a single main pole are provided. 3. When ordering specify desired control voltage. See next page for control voltages. 4. Control line fuses can be used to supply power from the remote control switch enclosures to external control stations. Any incoming service or control power should have appropriate overcurrent protection at their source as required by application codes. For a grounded control voltage, one fuse should be ordered; for an ungrounded control voltage, two fuses should be ordered. 5. Shipped loose for open types. Installed for enclosed types. 6. U.L. recognized. 2 3,5,6 3,5,6 3,5,6 4,5 4A and 4B 22 47 48 49 52A 52B 52C

The largest service organization of its kind ASCO 920 Optional Auxiliary Control Relays Features Allows control of RC switches directly from energy management systems. UL recognized for use with ASCO RC switches. Permits low voltage AC or DC normal. Low VA burden. Narrow width design. Incorporates ASCO 5 relays. Polycarbonate dust cover for protection against industrial environment. Barrier screw type terminals with approved means for solderless connection of conductors. Auxiliary Control Relays to Operate RC Switches are useful when: When the controlling device does not have adequate current-carrying capacity to directly control the RC switch. When the control station is to be located at a distance greater than the allowable RC switch line run. When the controlling device is only available as a single pole, single throw contact, necessitating a two-wire control line. When Form 3 (start-stop) control for an RC switch is required. Two-Wire Control Accessory 47 Catalog No. 32A40 ASCO relay for two-wire control. Standard Control Voltages: 24,20, 208, 240, 277VAC, 50 or 60Hz, 24 or 0VDC Accessory 47 Two-wire relay control of a remote control switch Three-Wire Control Accessory 48 Catalog No. 32A36 ASCO relay for three-wire control. Standard Control Voltages: 24,20, 208, 240, 277VAC, 50 or 60Hz, 2, 24, 32, 48 or 0VDC Accessory 48 Three-wire relay control of a remote control switch Dimensions inches (mm) for ASCO two-wire and three-wire Control Relays Height 6-/2 65 (mm) Width 2 5 (mm) Depth 3-3/8 86 (mm). Dimensional data is approximate and subject to change. Certified dimensions available upon request. Operating Coil Characteristics Rating Accessory 47 Nominal AC Pickup Voltage AC Nominal DC Pickup Voltage DC Maximum Voltage 3.0 VA 2.0 VA 85% of Nominal 2.5 Watts 80% of Nominal 20% of Nominal Accessory 48 85% of Nominal.2 Watts 75% of Nominal 20% of Nominal

A SCO Power Technologies 50 Hanover Road F l o r ha m Park, NJ 07932 USA 8 0 0 8 0 0 A SCO w w w. ascopower. co m w w w. ascoapu.com Emerson Network Power. The global leader in enabling Business-Critical Continuity TM. AC Power Connectivity DC Power Embedded Computing Embedded Power Infrastructure Management & Monitoring Outside Plant Power Switching & Controls Precision Cooling EmersonNetworkPower.com Racks & Integrated Cabinets Services Surge Protection Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 20 Emerson Electric Co. Publication 3206 R2 February, 20 Printed in the U.S.A.