Abstract. 1. Introduction and Background

Similar documents
Length, Germany, PTB (Physikalisch-Technische Bundesanstalt)

RWS E Frenco GmbH

Assessment of the volumetric accuracy of a machine with geometric compensation

The Virtual CMM a software tool for uncertainty evaluation practical application in an accredited calibration lab

COMPARISON OF ERROR MAPPING TECHNIQUES FOR COORDINATE MEASURING MACHINES USING THE PLATE METHOD AND LASER TRACER TECHNIQUE

Good Practice guide to measure roundness on roller machines and to estimate their uncertainty

RK E Frenco GmbH

RM E Multiple Inspector Rotating simultaneous measurements

Contents 1 Measurement and Machine Tools An Introduction

A practical system for 5-axis volumetric compensation

AN EVALUATION OF NON-CONTACT LASER SCANNER PERFORMANCE USING CALIBRATED ARTIFACTS

Caliber Gauges & Instruments Laboratory, S. No. 14/1, Dattadigamber Soc. B, Warje Jakat Naka, Pune, Maharashtra

[Type text] [Type text] [Type text] GearPro Procedure

UNIT IV - Laser and advances in Metrology 2 MARKS

Limitations of laser diagonal measurements

Calibration House, 71, Tarani Colony, Near Amir Vila, A. B. Road, Dewas, Madhya Pradesh. Discipline Mechanical Calibration Issue Date

Brochure. XR20-W rotary axis calibrator

Development of CNC machine performance standards

BGA Technical Awareness Seminar 2010

Image Measuring Instrument

A02 -e- 01/2008. Product Lines

QC20-W wireless ballbar system description and specifications

Investigating the volumetric performance of multi-axis measurement arms

Error Budget as a Design Tool For Ultra-Precision Diamond Turning Machines Form Errors

Laser diagonal testing

Micro-Flat Datums Pvt. Ltd., Plot No , Zone D-3, GIDC, Vitthal Udyognagar, Anand, Gujarat

ACTA TECHNICA CORVINIENSIS Bulletin of Engineering Tome X [2017] Fascicule 2 [April June] ISSN:

Development of the next generation of 3D probing systems for the future co-ordinate measuring

Study on Gear Chamfering Method based on Vision Measurement

Overview over the different measurement methods for geometry error correction for measuring machines and machine tools

Research on Measuring and Optimization Method of Dynamic Accuracy of CNC Machine Tools

GEAR DESIGN SOLUTIONS

Accuracy for CMMs and Machine Tools

Precimar. PLM and CiM Universal Length Measuring Machines

Nanoprecise measurement systems for. high-end industrial applications. Press Release

COMPACT PRECISION LINEAR MOTORIZED ACTUATORS LSMA Series LSMA-173

A novel approach to the inspection of gears with a co-ordinate measuring machine - theoretical aspects

Industrial Metrology from Carl Zeiss. Form Measuring Machines

XL-80 spares list. Application note. Overview

Introduction to Metrology. ME 338: Manufacturing Processes II Instructor: Ramesh Singh; Notes: Profs. Singh/Melkote/Colton

Optimal Path Planning for Helical Gear Profile Inspection with Point Laser Triangulation Probes

University of Huddersfield Repository

Autocollimator Calibration for Synchrotron Metrology: Advancing from Plane to Solid Angle

XM-60 measures all six degrees of freedom

SWING ARM OPTICAL CMM

Reliance Calibration Laboratory, Sr. No. 21/7, (Gokul Nagar, Narhe), Lygude Estate, Dhayari-Sinhgad Road, Pune, Maharshtra

A Novel Kinematic Model of Spatial Four-bar Linkage RSPS for Testing Accuracy of Actual R-Pairs with Ball-bar

Ch 22 Inspection Technologies

Creative Calibration Centre, Plot No.-3802, Laxman Vihar, Phase-I, Gurgaon, Haryana. Discipline Mechanical Calibration Issue Date

IND62 TIM CALIBRATION OF FREE-FORM STANDARD AND THEIR APPLICATIONS FOR IN-PROCESS MEASUREMENT ON MACHINE TOOLS

STRAIGHT LINE REFERENCE SYSTEM STATUS REPORT ON POISSON SYSTEM CALIBRATION

Coordinate Measuring Machines with Computed Tomography

Strategy. Using Strategy 1

INSPECTION OF THE TURBINE BLADES USING SCANNING TECHNIQUES

1. Motivation 2. Nanopositioning and Nanomeasuring Machine 3. Multi-Sensor Approach 4. Conclusion and Outlook

UNITEST - A new device for the static and dynamic testing of unconventional machine structures

Precimar. PLM and CiM Universal Length Measuring Machines LENGTH MEASURING MACHINES FOR HIGH-END CALIBRATION

Cylinders in Vs An optomechanical methodology Yuming Shen Tutorial for Opti521 November, 2006

Measuring Geometrical Parameters of Involute Spur Gears to Sub-pixel Resolution.

501, , 1052, , 1602, 1604 EXCEL EXCEL 1602UC EXCEL 1052UC EXCEL 501HC. Micro-Vu Corporation. Precision Measurement Systems

Innovations in touch-trigger probe sensor technology

quality news Carl Zeiss Updated Software

Chapters 1 7: Overview

FULLY AUTOMATIC ROUGHNESS MEASUREMENT "IN MINIATURE"

GEOMETRIC CALIBRATION OF CMMs USING 3D LENGTH MEASUREMENTS

(1) (2) be the position vector for a generic point. If this point belongs to body 2 (with helical motion) its velocity can be expressed as follows:

R0 in µm THP in µm 18 C - 22 C

Linear, and segmented over up to 1000 points Squareness calibration Matrix compensation over up to 30 x 30 points

[1] involuteσ(spur and Helical Gear Design)

MULTIPLE-SENSOR INTEGRATION FOR EFFICIENT REVERSE ENGINEERING OF GEOMETRY

H Precitech, Inc. Microfinish ϑ 300 CNC ASPHERIC LENS POLISHING MACHINE MACHINE SPECIFICATION REVISION 6. Page 1 of 5

good check of volumetric accuracy. However, if the mea error components. However, if the errors measured are large,

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling

COMPARISON OF TWO INSTRUMENT DESIGNS FOR NON-CONTACT MEASUREMENT OF GOSSAMER MIRRORS

A NATIONAL MEASUREMENT GOOD PRACTICE GUIDE A NATIONAL MEASUREMENT GOOD PRACTICE GUIDE. No. 42. No. 42. CMM Verification.

Machine Tool Alignment Boring Mills, Gantries, Machining Centers, VTLs

Brochure. Discover RENGAGE technology high-accuracy machine tool probes with market-leading performance

3D Volumetric Positioning Measurement and Compensation of CNC Machines Using Laser Vector Technique

Good practice guide for verification of area-scanning on-board metrology systems on machine tools

Surface Texture Measurement Fundamentals

Vasals Engineering Industries, No. 33, First Floor, Govardhan Garden, J.C. Industrial Area, Kanakapura Road, Yelachenahalli, Bangalore, Karnataka

BENCHMIKE 283 SERIES. Off-Line ID/OD/Wall measurement systems for pipe and tube samples

Form Measurement ROUNDTEST RA-1600

Jinying. factors to. proposed. Introduction. Error element. solutions. same time, Figure

نﺎﻤﻟ آ ﻲﻧﺎﭙﻤﻛ يرﺎﺼﺤﻧا هﺪﻨﻳﺎﻤﻧ

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL

Wireless Intuitive Probe System - WIPS - Troubleshooting Guide

A U T O C O L L I M A T O R S

Discipline Mechanical Calibration Issue Date Certificate Number C-0386 Valid Until Last Amended on - Page 1 of 6

Roll angle in 6DOF tracking. CMSC Charlotte-Concord, July 2008

Involute Simulation Softwares Inc

MarSurf. The new generation of contour measurement systems MarSurf XC 20 MarSurf XC 2

MECATRONIC EQUIPMENT FOR BEARING RING SURFACE INSPECTION

The development of a laser array measurement system for three dimensional positioning testing in machine tool

5-Axis Flex Track Drilling Systems on Complex Contours: Solutions for Position Control

Straightness measurement

Geomet operates in four different levels designed to match your inspection needs. These levels are known as:

Complete 3D measurement solution

Micro Cutting Tool Measurement by Focus-Variation

Discipline Mechanical Calibration Issue Date Certificate Number C-0131 Valid Until Last Amended on - Page 1 of 10

Transcription:

Methods of testing calibration equipment in the UK's National Gear Metrology Laboratory R.C. Frazer and J. Hu Design Unit, Stephenson Building, University ofnewcastle upon Tyne, NE1 7RU England. Abstract This paper describes the functions of the U.K.'s National Gear Metrology Laboratory (NGML). The parameters which are measured on gears and the equipment which is used to calibrate these parameters are described. Methods of verifying the accuracy of calibration equipment are discussed, with particular reference to the scanning mode of operation used by the equipment. A comparison of calibration results between the European Primary Calibration facility at PTB, Braunschweig Germany and NGML is presented. The results demonstrate that high accuracy calibration data may be obtained from commercially available inspection equipment, if the correct methods of testing are used. 1. Introduction and Background The U.K.'s National Gear Metrology Laboratory (NGML) has been run by Design Unit, University of Newcastle upon Tyne for the past nine years. The main function of the Laboratory is to provide a the traceable calibration service for the parameters which are measured on gears. These parameters are lead (tooth alignment error), profile (involute shape error), pitch (tooth spacing error) and tooth thickness. Although NGML is a National Laboratory, it is not the primary calibration facility. Physikalisch Technische Bundesanstalt (PTB) in Germany is the European Primary Gear Calibration Laboratory by the mutual agreement of countries who participate in WECC ( Western European Calibration Cooperation) and EAL (European Co-operation for Accreditation of Laboratories). PTB are responsible for the realization of the primary gear standards which are derived from the SI base unit of the metre (Fig.!)[!]. NGML are accredited by NAMAS (National Accreditation of Measurement and Sampling) which is administered by UKAS (UK Accreditation Service), for the traceable calibration of master gears and gear artefacts. NGML,

232 Laser Metrology and Machine Performance as a National Laboratory, can offer the lowest traceable calibration uncertainties of any UK gear calibration laboratory : lead ± pm/100mm profile ± pm adjacent pitch ± pm cumulative pitch ± 2.0pm radial runout ± 2.5pm tooth thickness ± pm The secondary functions of the laboratory are to provide : 1) an independent gear inspection service to manufacturers and users of gears. 2) training for industry via short courses and seminars in conjunction with the British Gear Association (EGA). 3) support for gear research in UK Universities. This paper concentrates on the calibration function of the laboratory, with particular reference to the methods used to verify the accuracy of gear calibration equipment. The methods described in this paper are developed from those which are used on a gear inspection machine in industry and are specified in the EGA Codes of Practice [2, 3]. 2. Gear Calibration Equipment 2.1 General Description NGML use two unmodified and commercially available CNC gear measuring machines to calibrate master gears and gear artefacts. The machines are: a Hofler EMZ 632 4-axis CNC gear measuring machine. The software comprises of a Hofler gear software package, Zeiss UMESS software package and the Zeiss GON gear software package. The machine is equipped with a 3-axis scanning probe system (Fig. 2). a Gleason GMS 430 4-axis CNC gear measuring machine with Gleason Gear software, with additional gear calibration software written by NGML. The machine has a single axis Tesa GT-31 probe, which is used to scan the tooth surface. The machine slide arrangement is identical to the Hofler. 2.2 Description of Measuring Modes Both machines measure (calibrate) lead and profile errors by moving a measuring probe across the tooth surface. This involves simultaneously moving one (or more) linear axis with the rotary axis in a synchronous motion under CNC control. Error data is gathered at typically 0.1mm intervals. The machines measure (calibrate) pitch by indexing the gear, which is mounted on the rotary axis, and directly measuring the angular position error using an optical angular encoder. All the teeth are measured in an incremental manner under CNC control.

2.3 Evaluation of Gear Measurement Results Laser Metrology and Machine Performance 233 The tooth shape error parameters which are normally used to assess the accuracy of a gear measuring machine are calculated by constructing a 'least squares fit' mean line through the error curve [3]. This adds further complexity to estimating the accuracy of the calibration process because the calibration data is a calculated value. 2.4 Calibration Strategy It is not feasible to calibrate a complex gear measuring machine as there are too many sources of error which will combine in a different unique manner for each geometry of gear measured on the machine. The best that may be achieved is that error sources are quantified, and where possible compensated, and their effects considered when estimating the calibration uncertainty budget (U^) for the calibration process. NGML use a combination of parametric calibration and functional tests, which use artefacts, to estimate the calibration uncertainty of the machine. The functional tests are designed,where ever possible, to test the machine in the same manner in which it operates while calibrating gear parameters. The results of this assessment are verified by comparing calibration data with PTB using the UK National Gear Artefacts. Further details of the procedures are given in section 3. 3. Machine Calibration and Verification Methods 3.1 Datum Axis and Linear Axis Alignment The rotary table axis is defined as the datum axis (Fig. 3). Alignment of the linear axes is carried out using a parallel 500mm long (050mm) mandrel. The mandrel straightness is within 0.4/^m ±0.2yum / 500mm and is traceably calibrated by the reversal technique at NGML. The mandrel is mounted on the rotary table (Fig.4). Radial and tangential axis alignment is calculated by the slope of the 'least squares fit' mean line using straightness data gathered at 2.0mm intervals on the mandrel. Mandrel mounting (swash) errors are eliminated by rotating the table through 180, repeating the straightness measurement and averaging the results. Squareness of the radial and tangential slides is calculated from straightness data after using the rotary table to index the mandrel through 90 intervals. The effect of rotary table indexing errors is reduced by averaging 4 pairs of straightness errors with the mandrel mounted at different angular positions on the rotary table. The vertical axis alignment on the Hofler is more accurately assessed by using Zeiss UMESS cone software. The mandrel is mounted vertically on the rotary table and measured as a cone by scanning vertical lines and gathering data

234 Laser Metrology and Machine Performance at O.lmm intervals. The table is rotated through 180 and the mandrel is remeasured. The average of the cone axis alignments defines the angular alignment of the vertical axis with respect to the rotary table axis. Errors in this axis alignment will directly effect the accuracy of calibration data. Angular roll errors(6^) of the radial(x) slide are also important, as they change the alignment of the vertical measuring slide with the datum axis (Fig.4). They are checked using Zeiss differential, electronic levels. The accuracy of the levels in differential mode is traceably verified by NGML using a small angle generator over 10^m/m range. The calibration uncertainty of the levels is ±0.5yum/m over this range. The results from these tests show that the axes of the Hofler are aligned within 3^m/m. Calibration data is corrected for the residual alignment error. 3.2 Straightness Measurement Vertical(Z) and tangential(y) axis Straightness errors (A^, A^) are measured using a Renishaw Laser Interferometer with Straightness optics and software. This measurement method is preferred because the dynamic data capture software allows data to be gathered dynamically, at O.lmm intervals, at normal calibration scanning speeds of 1 and 2mm/sec. Angular errors(6^ 6^8Ji are checked, using angular optics and software, to identify the causes of the Straightness errors, but in most cases, the Abbe offset of the probe is constant so this information is not used for calibration data correction. The laser Interferometer is traceably calibrated by the National Physical Laboratory (NPL). Straightness and angular optics and software are traceably verified at NGML. The measurement system errors are within ±0.3/^m for Straightness errors (over a 5/^m range) and ±0.6^m/m for angular errors (over a lo^um/m range), with 700mm axis travel and in the laboratory environment. Fig 5 shows an example of a static, vertical axis Straightness result from the Hofler EMZ 632 over 700mm of axis travel. The bi-directional Straightness error is less than 1.2 yum. 3.3 Probe System Verification Each probe axis which is used to calibrate gears is verified separately using artefact based tests. The magnification and discrimination is verified by calibrated gauge blocks and bi-directional repeatability is verified using calibrated ring gauges. Artefacts are used to check the dynamic performance of the probe and the data gathering system. The test methods include: A 'bent' mandrel (2.3/^m TTR) which is rotated under the probe. As the mandrel is rotated the probe readings are taken and compared to static calibration data. (The mandrel is traceably calibrated using Zeiss UMESS software by the reversal technique). The Hofler x-axis probe normally indicates 2.0 to 2.2/^m TIR. A 'rough' mandrel which has a thread of 0.6mm pitch and a mean 16/^m height,

Laser Metrology and Machine Performance 235 has been traceably calibrated by Teeside Metrology Centre, and is used to assess the probe dynamic performance at normal calibration speeds. The mandrel is measured as a gear, which also checks data acquisition. The results in Fig. 6 show that at a 2mm/sec scanning speed, the differences between the static calibration results are less than 0.5/^m at any specific calibration point. This calibration technique is still being developed because variations in form error on the mandrel can still cause comparison problems. The results of these tests yield a probe U^ of ±0.3//m over a 10/^m measuring range when measuring gears with waviness errors of less than 2//m. 3.4 Linear Axes Position Errors Linear axis position errors are measured dynamically using a Renishaw laser Interferometer (U<% ±l.l/um/m) with quadrature signal output. Position data is gathered using a Klingelnberg PEW-02 Transmission Error Measuring System which compares the position of the laser with the linear encoder position and calculates the difference. Data is normally gathered at O.lmm intervals along each linear axis with the laser mounted in the probe stylus plane. Fig. 7 shows the results from the Gleason GMS 430 CNC gear measuring machine. The cyclic error and general form errors were found to be caused by problems with the ball screw drive and Abbe errors. 3.5 Rotary Table Tests The rotary axis roundness accuracy and runout is verified by measuring a traceably calibrated roundness standard using the measuring machine probe. Axial runout is verified by checking the runout of the table over 3 revolutions. The indexing or position accuracy is verified by comparing the spindle encoder output (Quadrature signal) with a second encoder (Heidenhain ROD800) using the Klingelnberg PEW-02. The differences between encoder positions at typically 1800 positions over 360* is checked and plotted (Fig. 8). The second encoder is indexed by 90 and the process repeated. The average combined error for both encoders is calculated and verified that it be less than the combined uncertainty claimed by the encoder manufacturers (the ROD 800 and spindle encoder U<% are each ± 1.0 arc sec). The 0.36 arc sec. steps shown in Fig. 8 are caused by the resolution of the ROD800 encoder. 3.6 CNC Servo Control Errors The servo control errors are not verified. Work is currently being carried out on applying the Klingelnberg PEW-02 encoder checking technique to this problem.

236 Laser Metrology and Machine Performance 3.7 Software Two methods are used to verify the analysis software: Three software packages are available in the laboratory and direct comparisons between packages is carried out by calibrating artefacts. Differences between packages indicate errors less than 0.6/^m/100mm are caused by differences in evaluation and data gathering methods. The evaluation of calibration data from artefacts which have the nominal geometry changed to create differences in measured errors. Differences between a predicted 20um change in calibration data were within 0.3fim. 4. Uncertainty Budgets The individual sources of error are used to estimate the uncertainty budget for the calibrated gear parameters. Uncertainty budgets are estimated in accordance with NAMAS directives [4]. 5. Comparison with PTB Calibration Data using Artefacts NGML maintain a range of artefacts which arefrequentlycalibrated by PTB. Comparisons between PTB and NGML calibration data are carried out before calibration of a client's gear artefact. Typical results are shown in table 1 to 3 for the 200mm diameter lead artefact with 0* and 30 helix angles, profile artefact and pitch artefact. The differences in results are within the PTB calibration uncertainty. (Important systematic errors which are measured using the techniques in section 3 are corrected before comparing calibration values. Data correction is carried out independently from the measuring software using simple mathematical models). 6. Conclusions The methods use a combination of artefact and laser based calibration techniques to efficiently verify the accuracy of gear calibration machines. The results from the tests demonstrate that using standard, commercially available, gear measuring machines in a calibration environment can give accurate calibration results. Acknowledgement NGML gratefully acknowledge the funding from DTI, Programme for Length which supports the research and development at NGML.

References Laser Metrology and Machine Performance 237 1. Beyer, W. Traceable Calibration of Master Gears at PTB. Proc. American Gear Manufacturers Association, Fall Technical Meeting. Cincinnati, Ohio, October 1996. Paper 96FTM4. 2. Anon. Codes of Practice for Gear Measurement and Machine Verification. DUCOP.04 and DUCOP.05, British Gear Association. Revision 1.1. 3. Frazer,R.C, Hu,J. Verifying the Accuracy ofinvolute Gear Measuring Machines, Proc. Lamdamap 97, University of Huddersfield, UK July 97 4. Anon. The Expression of Uncertainty and Confidence in Measurement for Calibrations, NAMAS document NIS 3003, Edition 8 May 1995. FLANK PTB Calibration Data U,5 NGML Calibration Data u,, DIFFERENCE 0 LF -1.8 1.2-1.9 1.4-0.1 0 RF -0.8 1.2-0.9 1.4-0.1 30=L-LF -4.4-5.0 1.7-0.6 30 L-RF -1.0-1.8 1.7-0.8 30 R-LF -5.8-5.2 1.7 +0.6 30=RRF -58-6.7 1.7-0.9 Table 1. Comparison of PTB and NGML Lead Calibration Data ( urn ) FLANK PTB Calibration Data u«ngml Calibration Data U,, DIFFERENCE 0 LF -1.1 1.0-1.2-0.1 0= RF 40.3 1.0 +0.2-0.1 Table 2. Comparison of PTB and NGML Profile Calibration Data ( FLANK 0 LF PTB Calibration Data 5.6 U,5 1.2 NGML Calibration Data U,5 6.4 2.0 DIFFERENCE +0.8 O'RF 5.8 1.2 5.2 2.0-0.6 Table 3. Comparison of PTB and NGML Cumulative Pitch Calibration Data ( nm)

238 Laser Metrology and Machine Performance f NGML \ (NAMAS Accred. No. 0250) > UK Primary Standard NAMAS Accredited Gear Calbration Laboratory UK Gearing Industry \ Fig. 1 Traceable Calibration Chain for Involute Gears V'TrtfS Fig. 2 Hofler EMZ 632 Gear Measuring Machine. 2(VERTICAL AXIS) BETWEEN \\ : CENTRE AXIS X(RADIAL AXIS) Y(TANGENTIAL AXIS) SPINDLE,^z% axis alignment Ayy - position error Ayx atraightness error Gyx - angle error Fig. 3 Measuring Machine Axis Definition.

Laser Metrology and Machine Performance 239 Fig. 4 Measurement of Axis Alignment with a Parallel Mandrel. Bidir, Straightness Least-scrua^es fit as Dat Ax Lo li :a*i?on:ngml ope: Err o -0.00987 T> : 0 K8 3:^5^ = Rep: lillel Bi-dir. RepT 0.0086 Fig. 5 Hofler Z axis Straightness Measurement results (urn). 4 : 1 O 2.5 mm 1000. Top Umit Value 1 Fis. 6 Dynamic Probe Performance Evaluation.

240 Laser Metrology and Machine Performance CN) O LLJ a, O CU (D C op in

Laser Metrology and Machine Performance 241 % Ol CD CD c U 3 _C m _c