PAC BI-DP BIM and 8701-CA-BI Carrier

Similar documents
VersaMax IP Input Module

PACSystems* RX3i IC695PBM300

VersaMax* IC200BEM003. PROFIBUS Master Module. Ordering Information. Specifications. GFK-2739 April of their respective owners.

Redundant System Redundant System P9-1-1

PAC BI-PN-05, 8516-BI-PN-05 and 8752-CA-NS-01

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products

EL731 PROFIBUS INTERFACE

GFK-2415A March Type of sensor connection

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

SMART RELAY SRW 01 V4.0X

I-7550E PROFIBUS/Ethernet Converter. User's Manual

CAN 300 PRO, Communication Module

Technical Support Note No. 105 Date August 2002 Rev. 1

Copyright: December 2017 Nidec Issue: E

PACSystems* RX3i IC694ALG233

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

PACSystems* RX3i IC694ALG232

VersaMax IP I/O Module

Analog Input, 16-Bit Thermocouple Module

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

PACSystems* RX3i CANopen Master Module, IC695CNM001 Quick Start Guide, GFK-2837 March 2013

GE Intelligent Platforms PAC8000 RTU

Profibus Gateway 3E V Technical Bulletin

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

PACSystems* RX3i IC695CMM002 and IC695CMM004

PACSystems* RX3i and Series 90*-30 IC694ALG442-CC and IC693ALG442-EC

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013

SK CU4-PBR-C Part number:

TB3P/TB4P I/O PROFIBUS DP FIELDBUS MODULE FOR PNEUMATIC MANIFOLD VALVES. Pg. 1 di 14

MCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module.

MGate 5111 Quick Installation Guide

L5353 Profibus-DP Communications Interface

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.

PAS 300, PROFIBUS Slave Interface Module

IL CAN BK-TC-PAC. Extract from the online catalog. Order No.:

VersaMax* Serial Communications Module

CPU module for zone 2 Series 9442/35

VERSAMAX IP PROFINET SCANNER. 1 Description. GFK-2760 June 2012

MGate 5102-PBM-PN Series

MTL8000-2/x Series Modular I/O

VersaMax* Analog Input, 16-Bit Thermocouple Module

Data sheet VIPA CPU 115DP (115-6BL22)

GE Fanuc IC695ALG708. Rx3i PacSystem

HART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation

CSI 6300 SIS Overview

BB2 Profibus DP option

SK TU4-PBR Part number:

Release 2.11 Standard AXE Primary Firmware is not intended for use on any 8521 Controller not licensed as a RTU.

Shown with terminal block Supports diagnostic point fault contacts in the logic program

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

INSTRUCTION SHEET. Eaton Logic Controller DeviceNet Distributed I/O Adapter Module. [Applicable Distributed I/O Adapter Module] ELC-CADNET

S-series Profibus DP Interface Card

BL compact Multiprotocol Station for Industrial Ethernet 16 Digital PNP Inputs BLCEN-16M8LT-8DI-P-8DI-P

M-series Intrinsically Safe I/O

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Features and Benefits. Certifications

Technical Information Fieldgate SFG500

PROFIBUS Gateway for MCD 3000 Series Soft Starters. User Manual

GW-7553-CPM PROFIBUS/CANopen GATEWAY. User's Manual

GE FANUC Parts 1. DeviceNet Network Master/Slave August 2002 GFK-1539A. Quick Start Guide. Product Description. Specifications. Preinstallation Check

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Type code. BLCEN-8M12LT-4AI-VI-8XSG-P Ident-No Nominal system voltage 24 VDC. Nominal current Vo Max. current Vo

S800 I/O ABB Automation

Installation and Programming Manual. This Manual describes the IBSS InterBus-S Slave, its uses and set up.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

RS-485 Products. ICP Electronics Australia Pty Ltd Communication Cards for PC/IPC P 2-1

DVPPF02-SL PROFIBUS DP Slave Communication Module

System Control Unit (SCU)

Data sheet CC 03, Commander Compact (603-1CC21)

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

Sauter Systems

Motors I Automation I Energy I Transmission & Distribution I Coatings. SymbiNet CFW-11. User s Manual

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Thermocouple Elements BLCEN-8M12LT-4AI-TC-4AI-TC

Technical Manual. HA Issue 4. Copyright Parker SSD Drives, Inc 2008

General information. Supply voltage

PROFIBUS-DP/MODBUS RTU REPEATER

MGate 4101-MB-PBS Series

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

IPC194. ipconv Protocol Converter

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide

Modular controllers CECX

BL compact fieldbus station for DeviceNet 2 Analog Inputs for Current or Voltage and 2 Analog Outputs for Voltage BLCDN-4M12S-2AI2AO-VI

Transcription:

June 2013 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier PROFIBUS DP Bus Interface Module and Carrier The 8507-BI-DP Bus Interface Module (BIM) provides the communications link between the PAC8000 series I/O modules and a PROFIBUS-DP host. High-speed acquisition of data from the modules and LAN operation speeds of up to 12 Mbaud allow the host to respond rapidly to changes in process conditions. The BIM gathers data from the I/O modules and makes it available to the host upon request. It is a slave to the PROFIBUS master. As well as cyclic data exchange, which is required for reading input and writing output data, the BIM supports PROFIBUS Extended Diagnostics for status information. The BIM(s) must be used with an 8701-CA-BI Redundant BIM Carrier, described on page 4. Redundant BIMs can be used for critical applications. Each BIM in the redundant pair operates in parallel, continually checking status to enable the backup BIM to monitor the health of the primary BIM. 8507-BI-DP Bus Interface Module For details on the installation and operation of the BIM, refer to the PAC8000 I/O - PROFIBUS DP BIM Instruction Manual, INM8507. Features support for up to 24 I/O modules redundant operation extended diagnostics for module and channel status PROFIBUS network speeds of up to 12 Mbaud non-volatile memory for configuration configurable via PROFIBUS host HART Pass-through support to monitor/configure HART devices Configuration/Reset of IP address Parameterization The 8507-BI-DP supports parameterization from the PROFIBUS master. The configuration is created in a PROFIBUS configurator using details provided in a GSD file. This method is fast and enables a configuration to be built based upon logical modules which represent the physical modules. Modules are added one at a time to the configuration. The configuration is passed from the PROFIBUS master to the BIM at the start of communication. If the system is stopped and re-started, or if the node goes through a cold start cycle, the configuration file is retransmitted to the BIM.

2 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier Standard and Extended Diagnostics The PROFIBUS BIM supports Standard and Extended Diagnostics. While the Standard Diagnostics provide standard PROFIBUS status information, the Extended Diagnostics provide detailed information relating to the status of the BIM, the health of the modules and the status of I/O channels. Depending on the I/O module type, events such as high and low alarm, open circuit and line fault are detected. Extended Diagnostic messages are generated on detection of any anomalies in I/O modules. Use of the diagnostic capability requires suitable support in the host application. For hosts unable to use diagnostic data in the control algorithm, it is possible to map the diagnostic data into the input dataframe. Important Note: The equipment must be installed, operated, and maintained in accordance with the installation and control drawings approved by the Certification Agencies. These drawings, together with the Agency Certificates, are available for download from www.ge-ip.com. PROFIBUS Bus Interface Module LED Indicators Indicator Off On Blinking Power (green) Power fail Power OK NA Master (yellow) Standby Master NA Healthy (yellow) Not healthy Healthy NA Fault (red) No fault Permanent fault NA Failsafe (red) Failsafe mode inactive Failsafe mode active NA RedCom (yellow) No redundancy communications received Communications received through redundancy link Railbus (yellow) No activity on railbus NA Railbus activity Link (yellow) A valid Ethernet link has not been established. Valid Ethernet link between 8507-BI-DP and an external device has been established. LAN (yellow) No Ethernet comms NA Ethernet comms PROFIBUS (yellow) No PROFIBUS comms NA PROFIBUS comms NA NA

PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier 3 PROFIBUS Bus Interface Module Specifications PROFIBUS Interface Protocol Transmission rates Maximum bus segment length (speed dependent) Table applies to cables with an impedance of 135 165Ω and a capacitance per unit length that does not exceed 30pF/m. Transmission standard Isolation (PROFIBUS to Railbus to Power Supply) Action on software malfunction I/O and Diagnostic Data Input data, including 2-byte Status word Output data, including 2-byte Control word Total Input plus Output data PROFIBUS-DP (to EN-50170) 9.6, 19.2, 93.75, 187.5, 500 Kbaud 1.5, 6 and 12 Mbaud Speed (baud) 9.6K 19.2K 93.75K 187.5K 500K 1.5M 6M 12M 1200 1200 1200 1000 400 200 100 100 RS-485 500V Modules go to failsafe. 240 bytes maximum 240 bytes maximum 480 bytes maximum Length (meters) Diagnostic Telegram length Option 1: 61 bytes Option 3: 29 bytes Option 2: (default): 13 bytes Option 4: 110 bytes Address setting System Power Railbus (12V) current Mechanical Module width Weight (approximate) Hazardous Area Approvals Hardware setting on carrier 420mA (typical) 520mA (maximum at -40 C) 42mm 500g Location of Equipment Same as Carrier. See page 4. Environmental Requirements Temperature, humidity, vibration and shock. Same as Carrier. See page 4.

4 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier 8701-CA-BI Redundant BIM Carrier For details on the installation and operation of the BIM Carrier, refer to the PAC8000 I/O - PROFIBUS DP BIM Instruction Manual, INM8507. Features accommodates two Bus Interface Modules supports PROFIBUS-DP provides dual PROFIBUS network connections can be used with DIN rail or panel mounting Carrier Specifications Power Supplies (x2) Hazardous Area Approvals Location of Node Electrical Railbus connector PROFIBUS LAN Serial Ports Ground terminals External DC power supply (optional) Power supply fail detection Environmental Requirements Ambient temperature: Operating Storage Relative humidity Vibration and shock Materials Carrier moulding Printed wiring board Mechanical Dimensions (overall) Weight (approximate) Mounting 8910-PS-DC (obsolete) are supported. BQ2320-9R-EX power supplies are an alternative to the obsolete 8910-PS-DC power supply. BQ2320-9R-EX supplies are mounted external to the 8701-CA-BI carrier and require a separate mounting kit, BQ2320-ACC. For power supply connections, see page 6. Zone 2, IIC T4 hazardous area Male out 9-pin, D-type (female) (x2) M4 screw terminal (x2) An 8-pin connector is provided at the top/rear of the carrier to connect a 12.0 VDC (±5%) power supply. This is an alternative to the carrier mounted PSU modules. PSU failures are reported to the BIM(s) via the carrier. External power fail signals can be input via the 8-pin connector. See Power Supply Connections on page 6. -40 C to 70 C -40 C to 85 C 5 to 95% (non-condensing) See PAC8000 System Specification Data Sheet Modified poly-phenylene oxide Epoxy resin woven glass laminate 178 (w) x 170 (d) x 68 (h) mm 450g Flat panel (two fasteners) or DIN rail DIN rail types Top hat, 7.5 x 35 mm to EN 50022.or 15 x 35 mm to EN 50022 or G- section, to EN 50035

PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier 5 Carrier Diagram PROFIBUS-DP Network (Serial Port) Interfaces Terminal Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Socket shroud NC RxD/TxD+ RTS+ Function GND (Bus Termination ground) V p RTS+ RxD/TxD- NC PROFIBUS-DP Network Address Switches Three rotary switches (1, 10 and 100) are provided to set the PROFIBUS Slave address.

6 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier User Controls Two change state buttons, one for each BIM, are provided on the carrier to enable the user to change the state of a BIM from Primary to Backup. The state change depends upon the BIM state before the button is pressed. State before Pressing Change State Button Primary (Momentary press) Backup (Momentary press) Press more than 3 seconds and less than 8 seconds (Primary only) State after Pressing Change State Button Change to Backup if current backup BIM is healthy. No change in state. Master IP Address is reset to 10.0.5.252 (Direct IP addresses will not be reset) Power Supply Connections External Power Terminal Function 1 Reserved. Connect jumper to pin 4 (+12V) to prevent the BIM from reporting a continuous power fail alarm. 2 0V input 3 External PSU power-fail input 1. 0V indicates the external supply is OK; an open circuit causes the BIM to report a power fail alarm. If an external power supply is not in use, connect jumper to pin 2 (0V) to prevent the BIM from reporting a continuous power fail alarm. 4 +12V input (PSU 1) 5 +12V input (PSU 2) 6 External PSU power-fail input 2. 0V indicates the external supply is OK; an open circuit causes the BIM to report a power fail alarm. If an external power supply is not in use, connect jumper to pin 7 (0V) to prevent the BIM from reporting a continuous power fail alarm. 7 0V input 8 2/1 power supply alarm defeat. If a Railbus isolator and 2/1 power supply (8922-RB-IS / 8920-PS-DC) are not in use, connect jumper to pin 7 (0V) to prevent the BIM from reporting a continuous power fail alarm. Product Documentation INM8507, PAC8000 I/O - PROFIBUS DP BIM Instruction Manual PAC8000 System Specification Data Sheet

PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier 7 Release History Hardware Versions Software Versions Comments GE02 Rev. B Primary firmware: 1.23 Boot firmware: 2.00 GSD file: 1.2 GEF01 Rev. C Primary firmware: 1.22 Boot firmware: 1.00 GSD file: 1.1 GEF01 Rev. C Primary firmware: 1.21 Boot firmware: 1.00 GSD file: 1.1 GEF01 Rev. C Primary firmware: 1.20 Boot firmware: 1.00 GSD file: 1.0 GEF01 Rev. B Primary firmware: 1.10 Boot firmware: 1.00 GSD file: 1.0 Implementation of digital signature for the firmware update. Update to include HART Pass-through support and Master IP reset functionality. Assign of IP address using Standalone IO configurator tool. Firmware version 1.21 resolves the issues listed in Problems Resolved by Release 1.21 on page 9. Firmware version 1.20 adds support for field upgrades of firmware and resolves compatibility issues with 8123-PI-QU and 8223-PI-IS pulse input modules. For details, see Problems Resolved on page 9. Change in manufacturing location only. No change in functionality, performance or compatibility. Important Product Information for this Release This release resolves the incompatibility between the 8507-BI-DP bus interface module and the 8123-PI-QU/8223-PI-IS pulse input modules. The 8507-BI-DP module s firmware is updated to support these two modules; there is no change in hardware. Updates The 8507-BI-DP firmware can be upgraded to version 1.23 using the downloader utility, which is provided in the upgrade kit. An upgrade kit can be downloaded from http://support.ge-ip.com. Upgrade kit: 82A1733-MS10-000-A4 (Version 1.23 firmware upgrade kit) 8507-BI-DP_GSD_File_GEF_0ADF_v1.2 (Version 1.2 GSD file) Functional Compatibility Unsupported Modules 8127-DI-SE sequence of events functionality not supported The 8507 PROFIBUS DP BIM does not support the 8129-IO-DC, 8132-AI-UN, 8133-HI-TX, 8140-DI-AC and 8142-DO-DC modules. The 8127-DI-SE module can be used with the 8507 PROFIBUS DP BIM. However the BIM does not support the Sequence Of Events functionality. 64-slot address bus module carriers are not supported The 8507 PROFIBUS DP BIM only supports 32-slot address bus module carriers. The 8709-CA-08 and 8729-CA-08 module carriers are not supported. Module diagnostics do not work with Delta V Delta V PROFIBUS masters do not report a module removal fault when a module is removed from the 8507-BI-DP s backplane. In this situation, all of the module s channel diagnostics report a bad channel status, which is the only indication provided that the module is not present.

8 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier The standalone I/O Configuration software does not support 8507-BI-DP for IO module configuration Compatibility with GEF01 Rev. C and earlier The standalone I/O Configuration software does not support the 8507- BI-DP. The 8507-BI-DP can be configured only through the GSD file using a PROFIBUS master. The 8507-BI-DP cannot be configured on a per-channel basis. When using module GE02 Rev. B with earlier versions of modules in redundant configuration, earlier version modules start-up faster compared to GE02 Rev. B version. As a result, earlier version modules will always be master after start-up. It is recommended that both BIMs in a redundant configuration have revision GE02 Rev. B or higher firmware.

PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier 9 Problems Resolved by Release 1.23 Support of HART Pass-through over Ethernet The support for HART Pass-through over Ethernet is implemented as part of this release. The new firmware version 1.23 corrects this issue. Restrictions and Open Issues The GSD file offers incorrect configuration options for Analog Input modules. For 8123/8223 PI module, some of the configuration options given in 8507-BI- DP GSD file are not applicable. The 8507-BI-DP GSD file incorrectly provides the options of open circuit and short circuit detection for analog input modules 8101, 8103, 8119 and 8201. The default configuration setting ( off ) for O/C detection and S/C detection parameters should not be changed when configuring these modules with the GSD file. For the Digital Output parameter of 8123/8223 PI module, only the options Not Used and Counter Preset Reached are applicable. Other configuration options should not be used while configuring the Digital Output parameter from the GSD file.

10 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier Operational Notes 8507 PROFIBUS DP BIM configuration Configuration of the PROFIBUS network address is done via rotary switches on the carrier. Configuration is delivered to the PROFIBUS DP BIM over the PROFIBUS network from a PROFIBUS master (parameterization). A GSD file for the PROFIBUS BIM and supported modules is available for creating a configuration in a PROFIBUS configuration package. The GSD file can be downloaded from the support website. The PROFIBUS DP BIM cannot be configured using the standalone Workbench IO Configuration software. PROFIBUS network speeds Replacing an 8502 PROFIBUS DP BIM with an 8507 PROFIBUS DP BIM Up to 24 modules supported PROFIBUS DPV1 not supported The 8507 PROFIBUS DP BIM supports all speeds up to 12MBps. The following differences should be considered when replacing an 8502 PROFIBUS BIM with an 8507 PROFIBUS BIM. The 8701-CA-BI carrier must be used with the 8507 PROFIBUS BIM. The carriers for the 8502 PROFIBUS BIM are not compatible with the 8507 PROFIBUS BIM. The parameterization data has changed slightly for the 8507 PROFIBUS BIM. A new GSD file is required to be used with PROFIBUS configuration software. The LEDs on the face of the 8507 PROFIBUS BIM have changed. See INM8507 for a description of the LEDs on the 8507 PROFIBUS BIM. The bits in the status word are significantly different between the 8502 and 8507 PROFIBUS BIMs. See INM8507 for a description of the status word on the 8507 PROFIBUS BIM. Bit 0 in the control word Scan BIM is not required to be sent to the 8507 PROFIBUS BIM. This bit is unused in the 8507. Bit 5 in the control word 15 bit analog data format is not supported in the 8507 PROFIBUS BIM. Scaling of Temperature Input Data (including mv & ohms) is different in the 8507 PROFIBUS DP BIM. See INM8507 for a description of the operation. Parameterization over a PROFIBUS network does not allow independent channel configuration. All channels must be configured the same. An 8502 PROFIBUS DP BIM could be configured using the IO Configurator software. The IO Configurator software cannot be used with the 8507 PROFIBUS DP BIM. The 8507 PROFIBUS DP BIM supports a maximum of 24 modules. The 8507 PROFIBUS DP BIM does not support PROFIBUS DPV1.

PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier 11 HART data acquisition is not supported The 8507 PROFIBUS DP BIM does not support HART data acquisition. HART data acquisition should not be used when configuring HART modules with the GSD file. If data acquisition for a HART module is configured, the input telegram will include extra data. The size of the input telegram will vary based on the configuration selected as follows: Configuration Input telegram Size AI8 + n ch Hart status AI8 + n ch m Hart var 8 words + n words 8 words + n (1 + m x 2) words Latching on Digital Input module does not clear 8507 PROFIBUS BIM and IO Module power-on states 8507-BI-DP transmits status word in bigendian format and reads control word in big-endian format. In the 8101 analog input module, fail state settings are ignored for deactivated channels. Configuration AO8 + n ch Hart status n words Input telegram Size AO8 + n ch m Hart var n (1 + m x 2) words Where n represents number of channels m represents number of Hart variables. Channel LEDs on AI, AO modules will flash in the absence of HART signals. The 8507 PROFIBUS DP BIM does not support latching for Digital Input modules. This functionality should not be enabled when configuring a Digital Input module with the GSD file. When the BIM powers-on, the IO modules respond to IO data received over PROFIBUS, if the PROFIBUS network is in Operate mode and the master is actively sending IO data to the BIM when it powers-on. If the PROFIBUS network is disconnected or in Clear mode when the BIM powers-on, the BIM enters failsafe mode. The BIM remains in Failsafe mode until the Exit Failsafe Mode control bit (Control Word Bit 15) changes state from a zero to a one. Subsequently, the IO modules respond to any IO data received over PROFIBUS. Note: When the BIM is in failsafe mode, the IO modules also enter failsafe mode and adopt their failsafe state if the BIM s Mod. Failsafe Timeout parameter is set to a non-zero value. If this parameter is set to disabled (default setting) the IO modules respond to IO data received over PROFIBUS. The 8507 transmits the most significant byte of the status word first and the least significant byte last. While reading the control word, the 8507 treats the first byte of the control word as the most significant byte. The second byte is the least significant byte. The 8507-BI-DP ignores the configured Failstate setting in the GSD file for channels that are configured as inactive. All inactive channels are forced to hold last state.

12 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier Digital input data format for eight-input Digital modules Increase in start-up time after power cycle and firmware update Invalid firmware update When an eight-input Digital module is configured for counter operation, PROFIBUS presents the digital inputs as word data. The most significant byte contains the states of inputs 1 8 and the least significant byte contains all 0s. This behavior applies to the following modules: 8109-DI-DC 8110-DI-DC 8111-DI-AC 8112-DI-AC 8113-DI-AC 8114-DI-AC 8220-DI-IS (8-input configuration) The start-up time of 8507 Profibus BIM is approximately 15 seconds for firmware versions 1.23 (boot code 2.00) and higher. When invalid firmware is downloaded, the module s fault LED will blink for a period of 60 seconds. After the timeout of 60 seconds the module is reset and remains in firmware upgrade mode. To recover the module, download a valid firmware version.