Similar documents
IRT Eurocard Type. DVA Mb/s ASI/SDI 8 O/P Reclocking Distribution Amplifier

User Manual DDA-4320 & ZDA-4320RH. ASI / SDI / STM-1 Path Protection & Distribution Amplifier. Page 1 of 17 Revision 08

FRU RU Frame with built in AC PSU. User Manual. I.R.T. Communications Pty Ltd Revision 03

AMS x1 Video + Audio Passive Switcher. User Manual. I.R.T. Communications Pty Ltd Page 1 of 10 Revision 03



OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

UTAH-100/XHDA SERIES

OPERATOR MANUAL OSD730 FULL DUPLEX FOUR CHANNEL DIGITAL AUDIO/DATA SYSTEM

8 Chanel HD SDI Over Fiber. Transmitter and Reciever Extender. User Manual L-8SDI-FE-HD-TX/RX

TM1 MK2 and TM1+ MK2 Installation Manual (SN on)

SPECTRA ENGINEERING PTY LTD

General Operating, Maintenance and Installation Manual

OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

ViaLite RF Splitter / Combiner

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

EOS-6000 Series Optical A/B Switch User Manual DC Version

3G/HD/SD-SDI Pattern Generator. User Manual

Manual Simatek Control Unit GFC 32

Manual Control Unit GFC 32

OPERATOR MANUAL OSD8826 SERIES DIGITAL VIDEO AND DATA FIBER OPTIC TRANSMISSION SYSTEM

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

OPERATOR MANUAL OSD420 SERIES VIDEO, AUDIO AND DATA FIBER OPTIC TRANSMISSION SYSTEM

OPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM

UPS Series. features: uninterruptible power supply. what great systems are built on.

OPERATOR MANUAL. OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER. WITH PoE SOURCE

RC702-FX Ethernet over SDH User Manual

6 Port HD/SD-SDI Splitter with Reclocking

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Instruction Manual RR-915C Video Receiver With Bi-directional Multi-Protocol Data And Bi-directional Contact Closure

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual

crio PN Installation Instructions V0.2/ COMSOFT

Model 7705 Control Module

Installing Sentor. Hardware Installation

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

National Semiconductor EVK User Manual

Single Channel Video Insert Unit with Bi-directional Data Channel for a Dual Redundant fibre ring

8 Channel Video Receive Unit with 2 Bi-directional Data and Audio Channels plus Ethernet for a Dual Redundant multimode fibre ring.

Product Specifications

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER

PMC494 10BaseT to 10Base2 PMC Media Converter

Voltage Transducer UMT516 / MT516

4 Channel Video Receive Unit with up to 8 Bi-directional Data and Audio Channels plus Ethernet

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

Installation & Operation Guide

OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

Instruction Manual Model Block Translator

ViaLite Digital GPS Fibre Optic Link

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

RangerBOSS Network Ready Constant Monitor Model CM2800

Premium Online Series

GE 800. Digital IP-Intercom Server GE 800 DATASHEET

AMU1-CHD+MK2 AUDIO MONITORING UNIT

NV6000 and NV8000 Series Universal Routers User Guide

Table of Contents. Functional Description Installation Power Source Power Connection Fiber Connection... 4

OPERATOR MANUAL OSD2153 SERIES GIGABIT ETHERNET MEDIA CONVERTER

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

8 Channel Video Transmit Unit with 9 Bi-directional Data and Audio Channels and Ethernet for a Multimode Fibre Link

Resolver to Digital Expansion Board

MODEL 805 USER MANUAL

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

iconverter 2-Module Power Chassis

Accessories and options

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

4 Channel Video Receive Unit with Bi-directional Data Channel and Ethernet for a Singlemode Fibre Link

Moxa TCC-100 Series Hardware Installation Guide

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Series 8900 LAN. Operation Manual. Part Number (example configuration) Part Number (example configuration)

DS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES

8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link

Intrinsically safe batch controller Batching Master 110i

CERBERUS. Cerberus multi I/O. Datasheet. Shaping the future of sound reinforcement. Cerberus. Applies to Part Number:

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER

Prisma II Platform. Optoelectronics

OPCOM STM-1 High Capacity Terminal Multiplexer USER MANUAL. Raisecom Technology Co., Ltd (4/2005)

Switched Mode Power Supply Operating manual PAP800

8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link

Agilent OBSAI Protocol Tester

OPERATOR MANUAL OSD860 SERIES DIGITAL 2/4/8 CHANNEL VIDEO/AUDIO/DATA/IP FIBER OPTIC MULTIPLEXER

Neon pr. ph/ ORP measurement. Applications. Description

MADI-PC MADI RECORDING SYSTEM

Installation and Operating Handbook. ICLH Combiner ISLH Splitter

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

PSBOC PSBOC 27,6V/5,5A/OC

RXTP ROOM TEMPERATURE

Instruction Manual RT-91685SL RR-91685SL Sixteen Channel Video Multiplexer With Two Bi-directional Data Channels

NVE40K Installation Guide

IQ21x Series Controllers

8000 Series: Installation Supplement R2-1-12

MANUAL NLMAINUNIT-2U-E & NLPDU. Remote power management and surge protection for IT equipment. Netshield (Pty) Ltd

16E1 + 1Ethernet Fiber Optical Multiplexer

Series 8000 RF Signal Switch Solution

Transcription:

I R T Electronics Pty Ltd A.B.N. 5 000 8 575 6 Hotham Parade, ARTARMON N.S.W. 064 AUSTRALIA National: Phone: (0) 949 744 Fax: (0) 949 749 International: +6 949 744 +6 949 749 Email: sales@irtelectronics.com Web: www.irtelectronics.com IRT Eurocard Type HDA-450.485 Gb/s HD 6 O/P Reclocking Distribution Amplifier Designed and manufactured in Australia IRT can be found on the Internet at: http://www.irtelectronics.com 450-HDA.ib.Rev0.doc Page of 9/07/006

Section IRT Eurocard Type HDA-450.485 Gb/s HD 6 O/P Reclocking Distribution Amplifier Instruction Book Table of Contents Page Operational Safety General Description Technical Specifications 4 Configuration 5 Link Settings 5 Location of links & user settings 5 Installation 6 SMU-4000 Installation 7 Figure : SMU-4000 module 7 HDA-450 SNMP Functions 7 Front and rear layouts 8 SNMP What Is It? 9 Maintenance & Storage Warranty & Service Equipment return Drawing List Index This instruction book applies to units later than S/N 050600. Operational Safety: WARNING Operation of electronic equipment involves the use of voltages and currents that may be dangerous to human life. Note that under certain conditions dangerous potentials may exist in some circuits when power controls are in the OFF position. Maintenance personnel should observe all safety regulations. Do not make any adjustments inside equipment with power ON unless proper precautions are observed. All internal adjustments should only be made by suitably qualified personnel. All operational adjustments are available externally without the need for removing covers or use of extender cards. 450-HDA.ib.Rev0.doc Page of 9/07/006

IRT Eurocard Type HDA-450.485 Gb/s HD 6 O/P Reclocking Distribution Amplifier General Description BLOCK DIAGRAM HDA-450 SIGNAL PATH OUTPUTS INPUT The HDA-450.485 Gb/s serial digital video reclocking distribution amplifier provides the user with a single standard module to cover a wide range of distribution and monitoring functions for High Definition (HD) digital signals. As well as accepting an HD signal, the HDA-450 will also accept Standard Definition (SD) rates such as SDI. ASI is also possible, however as three of the six outputs are inverted only the non-inverted output ports are suitable for ASI. Serial digital signals suffer severe deterioration over relatively short cable distances. This is especially so with the HD high data rate. The HDA-450 provides a means of extending the working distances that can be achieved by equalising and re-transmitting the data mid route. The HDA-450 will automatically reclock either a.485 Gb/s HD signal or a lower rate SD signal and automatically adjust the output driver slew rate to suit. Front panel LEDs indicate when an input signal is present and also whether it is either an HD or SD type of signal. A relay alarm output, with a selectable N/O or N/C switch to ground contact, is available for indication of loss of input signal or loss of power. An optional SNMP (Simple Network Management Protocol) plug in module is available for remote monitoring when used in conjunction with IRT s 4000 series frame fitted with SNMP capability. The HDA-450 is designed to fit IRT s 4000 series frame for use with IRT s SNMP system as well as being suitable with IRT s Standard 000 and 000 series Eurocard frames and may be used alongside any other of IRT s analogue or digital Eurocards. Standard features: EQUALISER SNMP Relay RL = Output Alarm RECLOCKER SIGNAL DETECT Automatic selection of either High Definition or Standard Definition digital signals 6 reclocked outputs Automatic input equalisation Locked signal presence LED and external relay alarm contact Optional plug-in SNMP monitoring module RL RL LINK O/P O/P O/P O/P 4 O/P 5 O/P 6 ALARM O/P 450-HDA.ib.Rev0.doc Page of 9/07/006

Input: Technical Specifications IRT Eurocard module Type HDA-450 Number. Type.485 Gb/s High Definition, or 70 Mb/s Standard Definition. Impedance 75 Ohm. Return loss * >0 db 5 MHz to 70 MHz, >5 db to.485gb/s. Equalisation Automatic, >50 metres at 70 Mb/s, >00 metres at.485 Gb/s for Belden 88 or equivalent cable. Outputs: Number 6 HD or SD, output slew rate automatically selected. Signal level 800 mv ± 0% Impedance 75 Ohm. Return loss * >0 db 5 MHz to 70 MHz, >5 db to.485gb/s. DC offset Nil. Performance: Output rise time Residual Jitter Connectors: Indicators: Power Signal present HD SD Power requirement: Voltage Consumption General: <00 ns, (80 ns typically). <0.5 UI at.485 Gb/s (measured with up to 00m of Belden 88 or equivalent cable) BNC. LED (green) for +5 Vdc. LED (green) when signal present. LED (green) when input signal is.485 Gb/s HD. LED (yellow) when output signal is 70, 60 or 540 Mb/s SD. 8 Vac CT (4-0-4) or ±6 Vdc 4.0 VA. Temperature range 0-50 C ambient Mechanical Suitable for mounting in IRT 9" rack chassis with input, output and power connections on the rear panel. Dimensions 6 HP x U Extended Eurocard (0 mm x 00 mm). Weight With rear assembly 85g. Finish: Front panel Grey background, silk-screened black lettering & red IRT logo Rear assembly Detachable silk-screened PCB with direct mount connectors to Eurocard and external signals Supplied accessories Optional accessories Rear connector assembly with matching connector for alarm outputs. SMU-4000 SNMP plug-in module for use with 4000 series frame fitted with SNMP Agent * Note: When mounted in an IRT 000 or 4000 series frame. Due to our policy of continuing development, these specifications are subject to change without notice. 450-HDA.ib.Rev0.doc Page 4 of 9/07/006

Configuration Link Settings: LK IN Reclocker set for HD or SD operation (Default position IN). OUT Reclocker automatically bypassed on lock loss. LK IN Selects Manual PLL rate. OUT Selects Auto PLL rate (Default position OUT, LK not installed). LK4, LK5, LK6 Set manual PLL rate. Must be left open when Auto PLL selection (LK OUT) used. Rate (Mb/s) LK4 LK5 LK6 4 0 0 0 70 0 0 60 0 540 0 0 485 0 LK7 N.C. Output alarm switches to ground on loss of input, or loss of power. N.O. Output alarm switches (breaks) from ground on loss of input, or loss of power. Location of links & user settings The following location diagram is not to scale and is intended only to assist in finding the location of links and other settings, which may need to be changed by the user during Configuration. Plug-in SNMP LK7 N.C. N.O. LK4 LK5 LK6 GND COM. +V LK LK 450-HDA.ib.Rev0.doc Page 5 of 9/07/006

Installation Pre-installation: Handling: This equipment may contain or be connected to static sensitive devices and proper static free handling precautions should be observed. Where individual circuit cards are stored, they should be placed in antistatic bags. Proper antistatic procedures should be followed when inserting or removing cards from these bags. Power: AC mains supply: DC supply: Earthing: Ensure that operating voltage of unit and local supply voltage match and that correct rating fuse is installed for local supply. Ensure that the correct polarity is observed and that DC supply voltage is maintained within the operating range specified. The earth path is dependent on the type of frame selected. In every case particular care should be taken to ensure that the frame is connected to earth for safety reasons. See frame manual for details. Signal earth: For safety reasons a connection is made between signal earth and chassis earth. No attempt should be made to break this connection. Installation in frame or chassis: See details in separate manual for selected frame type. Digital Input and Outputs: Input and outputs are all 75 Ω BNC type for connection with high quality 75 Ω coaxial cable suitable for either.485 Gb/s high definition digital signals for HD use, or for 70 Mb/s standard definition signals for SD use. Ensure that links settings are correctly set for the mode of operation required as described in the Configuration section of this manual. Alarm Output Connection: A normally open, or normally closed, -pin connector is provided on the rear assembly for an alarm connection on loss of signal input or loss of power. Pin is permanently tied to ground. During an alarm condition an on board relay contact either shorts or open circuits pin to/from ground dependent on the position of link LK7, as described in the Configuration section of this manual. Front Panel Indicators: Front panel LED s indicate the presence of an input signal (SIG Green); whether the input signal is an HD signal (HD Green) or an SD signal (SD Yellow); and the presence of power to the module (DC Green). 450-HDA.ib.Rev0.doc Page 6 of 9/07/006

SMU-4000 Installation The SMU-4000 plug-in SNMP management controller module can only be fitted to IRT s 4000 series modules that are capable of being SNMP upgradeable. To determine whether a module is SNMP upgradeable, a square section on the main PCB is silk screened and fitted with three multipin sockets as shown below: J J This is where the SMU-4000 plug-in SNMP management controller module is fitted. The three sets of multipins on the underside of the SMU-4000 line up with the three sets of multipin sockets on the main PCB module. Align all pins and then gently press the SMU-4000 all the way down into place. If the SMU-4000 is not already programmed with the correct firmware to match the module that it is being plugged into, it then needs to be programmed via the pins on the topside of the SMU-4000. Note that installation will generally be done by IRT Electronics at the time of ordering. Note also that an SMU-4000 will only be functionally operational when the main module that it is plugged into is fitted into an IRT 4000 series frame fitted with a CDM-4000 SNMP agent and being interrogated by a suitable Network Management System. HDA-450 SNMP Functions: With the HDA-450 installed in an IRT 4000 series frame with SNMP capability, the HDA-450 can be interrogated by an SNMP Network Management System (NMS). The following SNMP functions are capable of being monitored by an NMS: An indication that an input signal is present; An indication of the current state of the Urgent Alarm; Trap automatically sent, if enabled, when an Urgent Alarm occurs or is restored; Unit reset control. J Figure : SMU-4000 module 450-HDA.ib.Rev0.doc Page 7 of 9/07/006

Front & rear panel connector diagrams The following front panel and rear assembly drawings are not to scale and are intended to show connection order and approximate layout only. HDA-450 6 O/P HD/SD D.A. P OUTPUTS OUTPUTS SK7 SIG SK6 HD SD DC N40 SK5 SK INPUT SK SK4 SK SK0 SK0 = Alarm SK0 = Gnd P 450-HDA.ib.Rev0.doc Page 8 of 9/07/006

SNMP What Is It? SNMP stands for Simple Network Management Protocol. It is an application layer protocol for managing IP (Internet Protocol) based systems. SNMP enables system administrators to manage system performance, and to find and solve system problems. SNMP runs over UDP (User Datagram Protocol), which in turn runs over IP. Three types of SNMP exist: SNMP version (SNMPv), SNMP version (SNMPv) and SNMP version (SNMPv). It is not the intention here to discuss the differences between various versions, only to bring attention to the fact that IRT Electronics modules, fitted with SNMP capability, use SNMPv. An SNMP managed network consists of three key components: Network Management Systems (NMS), agents, and managed devices. An NMS is the console through which the network administrator performs network management functions, such as monitoring status (e.g. alarm states) and remote controlling, of a set of managed devices. One or more NMSs must exist on any managed network. Generally the NMS is a computer running third party SNMP control software. There are a number of third party SNMP software applications currently available on the market. An NMS polls, or communicates with, an agent. An agent is a network management software module that resides in a managed device. An agent has local knowledge of management information and translates that information into a form compatible with SNMP. The agent, therefore, acts as an interface between the NMS and the managed devices. The NMS sends a request message, and control commands for the managed devices, to the agent, which in turn sends a response message, containing information about the managed devices, back to the NMS. A managed device contains an SNMP agent and resides on a managed network. Managed devices collect and store management information and make this information available to NMSs using SNMP. Managed device agent variables are organised in a tree structure known as a Management Information Base (MIB). Within the MIB are parameters pertaining to the managed device. An Object Identifier (OID) number within the MIB defines the managed device type. This is a unique number specific to the model of managed device. Other information relating to the device is also stored, information such as alarm states, controllable settings, etc. The MIB tree is organised in such a way that there will be no two MIB files with conflicting placements. Normally an NMS polls an agent for information relating to the MIB in a managed device to be sent back to the NMS. When certain conditions are met within the MIB, such as major alarm conditions, for example, the agent automatically sends what is known as a trap to the NMS without any prompting from the NMS. This allows automatic notification of a predetermined event. NMS NMS SNMP Block Diagram IP Network SNMP Agent Protocol Engine SNMP Agent Protocol Engine SNMP Agent Protocol Engine MIB MIB MIB SNMP Agent SNMP Agent SNMP Agent 450-HDA.ib.Rev0.doc Page 9 of 9/07/006

SNMP with IRT Products: IRT Electronics currently employs SNMPv with its 4000 series frame. The frame acts as an agent when fitted with a CDM-4000 module. This module has its own designated slot next to the power supply so as to not affect the number of modules that the frame will take. Communication between the NMS, the frame and its loaded modules are via this CDM-4000 module. Note that the NMS software is third party and not supplied by IRT Electronics. Ethernet connection for SNMP operation is via an RJ45 connector on the rear of the frame, below the mains inlet. Ethernet rate runs at either 0 baset or 00 baset. Frame parameters, such as Name, Address and Location, are set via an RS interface, a D9 connector on the rear of the frame below the mains inlet. A software terminal emulator, such as Tera Term or HyperTerminal, is used for setting and reading the parameters of the frame. IRT modules that are SNMP compatible need a plug-in SMU-4000 module with a program relevant to the module that it is plugged into. Depending on the module, besides the module identification, parameters such as alarm states, inputs and controls etc. are communicated to the CDM-4000 agent via a data bus on the rear of the frame. Thus the CDM-4000 collects information on what is loaded within the frame, what positions they occupy, and their current status for communication to the NMS when the NMS sends a request for information. In the event of a major alarm from any of the SNMP compatible modules, or power supplies, a trap is automatically sent by the CDM-4000 agent to the NMS without any prompting by the NMS. This alerts the operator to any fault conditions that may exist that need immediate attention. RS Ethernet FRU-4000 0/40 V 50/60 Hz FRAME 0.7 A (max.) Alarm + - 48Vdc FUSES 0/40 Vac 500 ma S.B. 0/0 Vac A S.B. AS60 approval no.: CS646N Ass. no.: 80469 IRT SNMP Connections Network IRT modules fitted with SMU-4000 IRT 4000 Series IRT modules fitted with SMU-4000 CDM-4000 PSU s NMS Ethernet Cable Ethernet Cable CDM-4000 PSU s IRT 4000 Series SNMP Setup IRT 4000 Series Ethernet Cable 450-HDA.ib.Rev0.doc Page 0 of 9/07/006

Maintenance & Storage Maintenance: No regular maintenance is required. Care however should be taken to ensure that all connectors are kept clean and free from contamination of any kind. This is especially important in fibre optic equipment where cleanliness of optical connections is critical to performance. Storage: If the equipment is not to be used for an extended period, it is recommended the whole unit be placed in a sealed plastic bag to prevent dust contamination. In areas of high humidity a suitably sized bag of silica gel should be included to deter corrosion. Where individual circuit cards are stored, they should be placed in antistatic bags. Proper antistatic procedures should be followed when inserting or removing cards from these bags. Warranty & Service Equipment is covered by a limited warranty period of three years from date of first delivery unless contrary conditions apply under a particular contract of supply. For situations when No Fault Found for repairs, a minimum charge of hour s labour, at IRT s current labour charge rate, will apply, whether the equipment is within the warranty period or not. Equipment warranty is limited to faults attributable to defects in original design or manufacture. Warranty on components shall be extended by IRT only to the extent obtainable from the component supplier. Equipment return: Before arranging service, ensure that the fault is in the unit to be serviced and not in associated equipment. If possible, confirm this by substitution. Before returning equipment contact should be made with IRT or your local agent to determine whether the equipment can be serviced in the field or should be returned for repair. The equipment should be properly packed for return observing antistatic procedures. The following information should accompany the unit to be returned:. A fault report should be included indicating the nature of the fault. The operating conditions under which the fault initially occurred.. Any additional information, which may be of assistance in fault location and remedy. 4. A contact name and telephone and fax numbers. 5. Details of payment method for items not covered by warranty. 6. Full return address. 7. For situations when No Fault Found for repairs, a minimum charge of hour s labour will apply, whether the equipment is within the warranty period or not. Contact IRT for current hourly rate. Please note that all freight charges are the responsibility of the customer. The equipment should be returned to the agent who originally supplied the equipment or, where this is not possible, to IRT direct as follows. Equipment Service IRT Electronics Pty Ltd 6 Hotham Parade ARTARMON N.S.W. 064 AUSTRALIA Phone: 6 949 744 Fax: 6 949 749 Email: service@irtelectronics.com 450-HDA.ib.Rev0.doc Page of 9/07/006

Drawing List Index Drawing # Sheet # Description 804999 HDA-450 HD/SD Distribution Amplifier Schematic Diagram 450-HDA.ib.Rev0.doc Page of 9/07/006

Control Interface P TX RX SIGNAL TX +5V Q5 BC807 4 5 6 J P RX SEL0 SEL SEL A B A B A B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 0A 0B A B A B A B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 0A 0B A B A B A B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 0A 0B A B A B MAN OUTPUTS SK7 L7R A B A B A B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 0A 0B A B A B A B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 0A 0B A B A B A B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 0A 0B A B A B ALARM HD/SD R5 K R50 4K7 804999is5.sch Output Drivers Output 6 Output 5 Output 4 Output SD/HD Output DDI DDI Output 804999is.sch Power Supply Circuit AC AC AC AC 4 804999is4.sch LK7 COPYRIGHT HDA-450 HD/SD Distribution Amplifier Title SIZE A DO NOT COPY NOR DISCLOSE TO ANY THIRD PARTY WITHOUT WRITTEN CONSENT SCALE Sheet Drawing No. 804999 N.T.S. of 5 IRT Electronics Pty. Ltd. ARTARMON NSW AUSTRALIA 064 DRAWN K.N. CHECKED ENG. APP. Revision: Date: 8-Jul-006 'DC' R7R R49 0R +5V LD 'grn' R4 4K7 n.c. n.o. DIN64RA -0-004 08-06-005 ECR794 PCB 805000 C4 47nF 'SIGNAL' +5V R46 470R LD 'grn' +V SK6 L6R R6R Q4 BSS Input and Reclocking DDO DDO SD/HD HD/SD MAN/AUTO SS SS SS0 LD R44 4K7 C5 47nF Q BSS Input C6 D BAS6 804999is.sch 4.7uF RLA V06 +5V 8 Q BSS RLB 5 0 C7 47nF ALARM CIRCUIT CONTACT CLOSURE (OR BREAK) TO GROUND ON ALARM, AS SET BY LK7 'SD' R48 470R SK5 LD4 'yell' 'HD' R47 470R L5R LD 'grn' R5R +5V SK4 L4R R4R R45 4K7 SK LR RR SK LR RR P 9 7 5 R4 4K7 J Q BSS LR SK INPUT RR SK0 J optional power in (used when fitted to FRU-00 frame) DIN64 8-0-005 ECR8