Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment?

Similar documents
How do I... If you manage a datacenter, we have a solution for you.

The -3Ph extension on a product indicates a 3 Phase power product.

MAJOR VA Power Inverter

Model HM-535 Power Supply Installation and Service Instructions

Intelligent Monitoring. Taking intelligent monitoring to a higher level

Out of Band Networking Device, Infrastructure, and Environmental Management for Communications Networks

How do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.

Smart Pro Rack/Tower UPS Intelligent, line-interactive network power management system

User Manual. Per Port Monitoring Models

Infrastructure for the Architecture

Test Asset Optimization Services Power Line Utilization Module (PLUM) DATA SHEET

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

An Overview of Telecommunications Packaging Requirements

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

CAR0548TN. Product Features. Benefits. -48V/ 500W rectifier

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

G5 PDU Installation Guide

Designing a Reliable Industrial Ethernet Network

2 Telecommunications Data Center Facility Requirements

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

Next Generation Data Center Facilities Design. Presenter: Ping Lin

Power Control and Distribution

Server Technology Inc.

Engineering and Manufacturing Excellence in Data Centre Infrastructure

Model# ANI SWH. Ver. 1.1

SMARTONLINE E3 UPS SYSTEMS

24/48V Battery Bank Ah High Cycling Long Life

Installing the Cisco AS5400XM Universal Gateway

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Designing a Reliable Industrial Ethernet Network

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SPECIFICATION FOR THE SUPPLY OF A BATTERY MONITORING SYSTEM

CPS VS UPS FOR POWERING DATA CENTERS

Sigma XT Ancillary Board (K588)

Model #: SU1500RTXL2U

Premium Online Series

ULTRA-COMPACT 48V, 24V and 12V INTEGRATED DC POWER SYSTEMS

SmartOnline Expandable Rack/Tower UPS System On-line, double-conversion protection for mission-critical applications

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

Delivered the Way Yo u Want

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial

InnoMedia Business VoIP ATA Models

MANUAL NLMAINUNIT-2U-E & NLPDU. Remote power management and surge protection for IT equipment. Netshield (Pty) Ltd

Safety Control Relay Product Catalog

UPS Series. features: uninterruptible power supply. what great systems are built on.

Polar PDUs POWER MANAGEMENT

DC Output Voltage range: 1V to 50V Current: up to 30A Power: up to 400W. Efficiency Typical 85-87% - (nominal line, full load, room temperature)

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

High Availability and Redundant Operation

ADVANCED TECHNICAL MANUAL AAC1 SMALL SYSTEM CONTROL CONSOLE. Redefine your comfort zone.

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

DC POWER OVERVIEW BROCHURE Powerful Solutions for Critical Data and Telecom Applications

ANI SWH. PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL

Power Monitoring in the Data Centre: Is the Right Time Now? Jacarta Ltd

HPE Intelligent Power Distribution Unit Installation Instructions

02 Why Does My IT Infrastructure Need a UPS?

Intelligent On-Line UPS

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Functional safety in BATTERY MANAGEMENT SYSTEMS

CONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 3

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

NetAnalyst Test Management Software Automated, Centralized Network Testing. NetComplete Service Assurance Solutions Portfolio

PDU. InfraPower POWER AUSTI AUSTIN AUSTIN AUSTIN 3 PHASE WSI WI WS W MD BASIC. Enclosure Power Management Solutions

SafeC S to MSR127 Conversion

I/O ETHERNET CONTROLLER ELAN1

Liebert GXT MT kva

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9

Model volt to 24 volt DC to DC Converter. Table of Contents. Introduction. 2. Specifications.. 2. Operation... 2

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

User Guide Regenerative & Non-Regenerative Digital DC Drives 5 to 1000 HP

SmartOnline 230V 2kVA 1800W On-Line Double- Conversion UPS, Tower, Extended Run, Network Card Options, LCD, USB, DB9

SmartPro Tower UPS System Intelligent, line interactive network power management system

Troubleshooting the Cisco RPS

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

HIT/HIX HART Isolator

Innovative Electronics for a Changing World INDEX

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

Preparing to Install the Cisco AS5350XM Universal Gateway

Electrical Demand Specification (Reference SOP: )

AT&T Switched Ethernet Service SM

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

TELCO. Tomi Männikkö/HW Architect, Datacenter R&D/ Nokia

POWERING TECHNOLOGY. Reliably powering your business. Solving your power needs. DC POWER SYSTEMS

SmartOnline V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

CAN enabled The retifier can be monitored and controlled through analogue signals. It is also equipped with a CAN signal bus.

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, LCD, USB, DB9 Serial

Tech Byte 25: UPS Systems - Key To Ensuring Business Continuity - Part 1

Buffered Power Supply PS-30DR v1.0

Power supplies CP-E, CP-S and CP-C range NEW! CP-E Range

MX480 3D Universal Edge Router

Cisco CRS 16-Slot Chassis Power Systems

Removal of Hardware ESD, Independent of Safety Logic Solver

Transcription:

Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment? A Network Power Management White Paper Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment? Answer Any enterprise or service provider that relies heavily on the use of 48 VDC internetworking equipment, such as routers, ATM switches, and DSLAMs, for mission-critical networks or e-commerce services. When a network goes down, the problem list gets very long, very quickly. The problem list includes lost revenue, customer dissatisfaction, decreased productivity and potential Service Level Agreement penalties. Many enterprises, CLECs, IXCs, ISPs and ASPs rely on 48 VDC internetworking equipment to power their business models and service offerings. When these devices lock-up or fail, the recovery options for these devices are limited. The most proven method to restore the device to its operational state is to cycle the power a Reboot. When the internetworking device is remotely located in a distant POP site, co-location facility, telco central office, or even an equipment room, gaining access to the device to perform the reboot presents additional challenges. Why Does Your Organization Need Remote Power Management? Consider this information polled from Server Technology s customers: 72% of all third party technicians service calls to locked-up remote network equipment are solved with a reboot operation. Average cost of a third party service call is $500. Downtime from locked-up or failing equipment can be reduced from 1.5 hours to minutes with a Sentry Remote Power Manager. The costs of lost revenue and/or service level penalties can be significantly reduced or altogether eliminated. What the Sentry -48 VDC Does for Remote Equipment Units The Sentry -48 VDC allows the network management center to perform essential operations for distributed equipment: Power Distribution: distribute dual power input feeds to multiple equipment units in a rack or cabinet and eliminate the need for a power distribution panel in the cabinet or rack. Power Measurement: Extend network management capabilities and protect the investment in internetworking devices with SNMP Measurement traps, including Load Sense, On Sense and Temperature Sense. Power Control: Perform a remote reboot and rectify locked-up or failing equipment. Also, manage remote equipment through console port access and ensure that software and carrier to the line are running correctly. How a Sentry -48 VDC Remote Power Manager Supports Equipment With a Sentry -48 VDC Remote Power Manager, recovery of locked-up devices is easy. The Sentry provides a logical, software-controlled interface to individual power modules. The network operations center can immediately establish a communications session with the Sentry to power cycle (Reboot) an individual internetworking device and quickly return the device to operation status. 1

In addition to its ability to reboot remote locked-up devices, the Sentry 48 VDC also serves as an Intelligent Power Distribution Unit, eliminating the need for a separate power distribution fuse panel. Summary -- service providers, hosting companies and all large enterprises with distributed LAN/WAN networks will improve network operations by installing Sentry Remote Power Managers in their enterprise equipment rooms, POP locations and co-location facilities. When a network device goes down or a distant server hangs up, Server Technology s remotely addressable power switches enable you to power On/Off and ReBoot your devices from a remote location via in-band or out-of-band communications. What is the Significance of Intelligent Power Distribution? Available power is the critical factor that defines what equipment can be installed. For businesses and service providers whose revenue streams are dependent upon the quantity of internetworking devices they manage, installing the maximum number of devices that the available power resource will support is critical. Yet, configuring the maximum number of devices for the power supply is not a straightforward exercise. In a 48 VDC network environment, internetworking devices receive power from battery packs via a 60 to 100 Amp power feed cable. The power input feed is then distributed to multiple devices in an equipment rack through a power distribution panel. With the 24x7 environment of the Internet economy, installation of new equipment is routinely needed to handle increasing data loads. Adding additional equipment, however, is constrained by the availability of power resources and complicated by the manufacturer s nameplate specification, which is generally inaccurate and cannot be used for power planning. The solution for adding new equipment to existing power resources is to perform power measurement verification. However, when equipment units are co-located at multiple sites, performing on-site power measurement verifications becomes costly and untimely. Additionally, the availability of personnel with the skills to perform power verification draws from a limited field. To expedite this process, performing remote-site power measurement verification through Sentry s Load Sense is the solution. The following diagrams show the benefits of real-time power measurement: Diagram 1: Manufacturer's Nameplate Power Planning 35 A 35 A 40 A 40 A Total Amps drawn 75 A 75 A Using the manufacturer s nameplate specification for power consumption (Diagram 1) would indicate that the available power resource has been maximized. 2

However, an on-site measurement verification (or a Remote power measurement verification through a Sentry -48 VDC) proves differently (Diagram 2): Diagram 2: Power Measurement Verification Total Amps drawn 19 A 19 A Using the Sentry s Load Sense option, the amount of power being used at each DC circuit is measured in a real-time manner. The result of real-time power measurement allows more equipment to be added on existing power resources (Diagram 3): Diagram 3: Add New Equipment on the Same Power Resource Total Amps drawn 26.5 A 26.5 A 3

Eliminate the Need for a Separate Power Distribution Panel The Sentry -48 VDC combines the functions of a power distribution panel and remote power management unit into a compact 2U 19 rack-mounted enclosure. Each power output block is protected by a push-to-reset/pull-to-break circuit breaker, replacing the old-style fuses on a power distribution panel. Heat from the high-amp load equipment units will frequently weld fuses into a fuse panel. When the fuse is welded, removing the fuse without damaging the fuse panel is nearly impossible. Sentry s push/pull circuit breakers eliminate the problem of high Amp loads welding fuses to their mountings on the fuse panel. Many 48 VDC devices do not have power on/off switches and require a fuse to be removed if the device is to be powered-off (rebooted). Installation engineers may use Sentry s push/pull circuit breaker as an on/off switch. Now new equipment can be safely added to an equipment rack without exposure to current carrying terminals. Expand Remote Power Management Capabilities with SNMP Traps The Sentry XL utilizes SNMP Measurement traps to extend network management capabilities and protect an enterprise s investment in internetworking devices. Load Sense dynamically measures the load in amps that each connected server, internetworking device and telecom equipment unit is drawing and sends an alarm when a unit draws power outside defined thresholds. Additionally, power-planning engineers can use Load Sense to determine how much capacity remains on an existing power source by precisely measuring the amps each equipment unit draws. On Sense feature ensures power is flowing through the Sentry XL. On Sense positively verifies that there is voltage at each of Sentry XL s power outlet circuits and sends an alarm when voltage is not present. Temperature Sense makes certain that remote hardware operates only in optimal temperatures. Each Sentry XL is fitted with temperature probes that measure the ambient temperature in degrees centigrade inside an equipment rack or cabinet. When low and high temperature thresholds are exceeded putting equipment units at risk, Temperature Sense reports the variance. With a Sentry XL unit, SNMP traps are generated: When the temperature exceeds user specified limits; When the device load on any of the Power Modules exceeds specified limits; When a failure is detected on any of the Power Modules; When the state (i.e., on or off ) of a Power Module is changed; and When the chain of Sentry units is started (i.e., booted). These traps can be enabled or disabled by the user, and the limits for the temperature and device load can be set by the user. Traps are detected by the Sentry and then sent to an attached LAN interface for relay onto an SNMP destination. Console Port Access The optional R484/R488 Any-to-Any pass thru connection ports connect to a remote device s console port to allow the reboot process and console port monitoring to be managed from the network operations center. If a device looses carrier from a high-speed communications line, the device must be rebooted to restore carrier. The Any-to-Any switch can be used to perform the reboot, monitor the software and make certain carrier to the communications line is restored -- without the need to dispatch technical personnel or install a terminal server in a remote location. 4

NEBS Compliant Network Equipment Building Standards (NEBS) is Bellcore s established equipment specifications for fault-tolerance and is a requirement for co-location equipment within a telco central office. NEBS ensures that telecommunications and network equipment located at a central office conforms to safety and operational requirements related to specific environmental hazards. For companies seeking to co-locate equipment within a telco central office, the NEBS compliant Sentry -48VDC provides an added level of assurance that their network equipment maintains high availability. Now, CLECs and ISPs can deploy the versatile Sentry -48 VDC alongside their DSLAMs, routers and other equipment in the Bell Atlantic, Southwestern Bell, Pacific Bell and Nevada Bell central offices. The Sentry 48 VDC has been tested to the following NEBS standards: GR-63-Core Spatial Requirements Section 2.0 Thermal Requirements Section 4.1 Fire Resistance Section 4.2 Earthquake/Vibration Section 4.4 Acoustic Noise Section 4.6 GR-1089-Core EMI Emissions Section 3.2 Lightning & AC Power Fault Section 4.0 Electrical Safety Section 7.0 Bonding and Grounding Section 9.0 Sentry 48 VDC Power Distribution, Power Measurement and Power Control Highlights: Remote Power Management = Increased Service Levels and Reduced Expenses Eliminate expensive third party service technicians calls to power cycle locked-up equipment Improved problem determination Faster Alarm notification and recovery Improved network availability Reduced equipment outages Improved facility security Real-time Power Measurement Add more (new) equipment on existing power resources New equipment = increased revenues Power Measurement at each DC circuit provides improved power planning and forecasting Enhanced equipment protection Eliminate a power distribution panel and eliminate associated welded fuse problems Push/Pull circuit breakers can be used an On/Off switch by installation engineers Load Sense provides over/under limit reporting for each device Temperature Sense sends alarms regarding ambient temperature beyond thresholds Always-on architecture eliminates single points-of-failure Auxiliary 5 Amp terminal block drives fans and aux equipment How to Measure the Benefits of a Sentry -48 VDC Power Manager Eliminate power distribution panel ($600.00) Eliminate one on-site service call/ yr. ($500.00) Eliminate one equipment outage/yr. ($500.00) Eliminate verification visits ($300.00) Improved SLA, reduced penalties?? Install new equipment faster/increased Rev.s + Value Optimize investments in Power resources + Value 5