Veritas Appliance Hardware Service Procedure

Similar documents
Veritas Appliance Hardware Service Procedure

Veritas Appliance Hardware Service Procedure

Veritas Appliance Hardware Service Procedure

Veritas Appliance Hardware Service Procedure

Veritas Appliance Hardware Service Procedure

Veritas Appliance Hardware Service Procedure

Veritas Appliance Hardware Service Procedure

Veritas Appliance Hardware Service Procedure

Dell SC5020 and SC5020F Storage System Owner s Manual

Customer Replacement Procedure

Customer Replacement Procedure

DNS-2608 Enterprise JBOD Enclosure User Manual

SCv3000 and SCv3020 Storage System. Owner s Manual

EMC VNXe. Replacing a link control card in a 12-slot disk-array enclosure REV 02. July, 2015

Customer Replacement Procedure

Customer Replacement Procedure

Dell SC7020 and SC7020F Storage Systems Owner s Manual

Customer Replacement Procedure

Replacing a 3.5-inch disk drive

Customer Replacement Procedure

Customer Upgrade Procedure

Dell SCv3000 and SCv3020 Storage System Owner s Manual

Dell EMC Storage MD1280 Enclosure Owner's Manual

EMC VNXe. Adding input/output modules to a disk processor enclosure REV 03. July, 2015

Customer Replacement Procedure

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

3 Here is a short overview of the specifications. A link to a data sheet with full specification details is given later in this web based training

Replacing an Advanced Power and Cooling (APC) Unit

EMC CloudArray. Customer Maintenance Guide REVISION 6.0

Customer Upgrade Procedure

ETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014

2002 Series FRU Installation and Replacement Guide

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Installation Instructions

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

Removing Components from the MX960 Chassis Before Installing It Without a Lift

Release Notes. Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series. Prerequisites. Preparing Your Location

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

Removing Components from the MX480 Chassis Before Installing It Without a Lift

Installation Instructions

Dell PowerVault MD3060e Storage Enclosure Owner's Manual

Port Type Link Status (Left Side LED) Speed (Right Side LED) Green solid: Link detected/no activity Off: No link/card offline

Installation Instructions

I/O Modules Overview. Before You Begin. I/O Module Options. ESD Requirements

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Installing the EN-4000

Installing a Network Module

Chassis (FRU) Replacement Guide

P1 PowerStation Backlight Bulb

SAS Disk Shelves. Service Guide. For DS460C, DS224C and DS212C. November _C0

XTM 1050 Replacement Parts Installation

Dell Storage Center. Owner's Manual. SC180 Expansion Enclosure. Regulatory Model: E11J Regulatory Type: E11J001

StorageWorks Building Block (SBB) for Disk Drives

Installing the Cisco SFS 3504 Server Switch

Installation Instructions

EXPRESS5800 3UDEU. Disk Expansion Unit User s Guide

Nvidia Quadro FX 5600 graphics card and auxiliary power adapter cable installation

Chassis Overview. About the Cisco NCS 4016 Chassis. This chapter provides an overview of the Cisco NCS 4016 chassis and components.

Installation Instructions

NetBackup Appliance Safety and Maintenance Guide

Maintaining the Avaya S8800 Server for Avaya Aura SIP Enablement Services

NetBackup Appliance Safety and Maintenance Guide

Installation Instructions

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

Replacing/Upgrading Mac Pro Processors (Early 2008)

Maintaining E-Series Routers

Intel Server Board S2600BP Intel Compute Module HNS2600BP Product Family

Installation Data. The 1771 OB module can control the following output devices: dc motor starters indicators solenoids

Installing the MWAM CHAPTER

Power Systems and 5877 removal and replacement procedures

F2A (M527) F2A (M506n/dn) F2A (M506x)

NetBackup 5000 Release Routine Maintenance. Issue 01. Date Symantec Corporation

Removing and Replacing Chassis Components

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

Installation Instructions

Before you begin. Installation and Setup Instructions for E-Series 60-Drive Trays. Unpack & Prepare. Install Hardware. Connect Hardware.

FlexPower Server User Guide

Veritas Velocity 7330 Appliance Product Description. Release 1.2.6

HP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions

Replacing the Gateway M305 Optical Drive

Maintaining the ERX System

Veritas Appliance Safety and Maintenance Guide

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

Quantum DXi6802 and DXi690x: Power Supply Replacement

AirPort Extreme Card

Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Shelves. Apply Power. Connect Data Hosts. Connect Ethernet Cables

Solutions 24 SBB RAID Subsystem Deskside Expansion Unit (SW300-Series) User s Guide

Intel RAID Controller RS3DC040/ RS3DC080 Quick Installation User's Guide

Dell EMC PowerVault MD3460 Storage Arrays

EMC Avamar Data Store Gen4S

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Tower to Rack and Rack to Tower System Conversion Guide

13 MMC for PC Option Modules

Replacement Instructions

Dell Storage MD1400 Enclosures Hardware Owner's Manual

Wiwynn SV320 Maintenance User Manual

Installation Instructions

Transcription:

Veritas Appliance Hardware Service Procedure Replacing a RAID Controller in a Veritas 5U84 Primary Storage Shelf Document Number: 217 Version: 1.0 (11/06/17) Purpose This document describes the process for replacing a RAID Controller in a Veritas 5U84 Primary Storage Shelf that is connected to a 5340 Appliance. Electrical Safety The static discharged by human bodies can damage static-sensitive components on the boards. When installing and maintaining the equipment, observe appropriate electrostatic safety precautions to prevent personnel injuries or device damage. When operating a device in an electrostatic sensitive area, you must take electrostatic-discharge (ESD)-preventive measures. These include wearing ESD-preventive gloves, an ESD-preventive wrist strap, and ESD-preventive clothes to avoid personnel injury or device damage. To prevent damage to the device, pay attention to the following during operations: Do not touch devices with bare hands because ESD from the human body may damage the electrostatically sensitive elements on a board. When dealing with the server or any of the internal components, wear an ESD-preventive wrist strap, ESD-preventive gloves, and ESD-preventive suit. High availability (HA) appliance service considerations Attention: A HA or multi-node appliance is serviced in the same manner as a single node appliance. About the RAID Controller in a 5U84 Primary Storage Shelf The Veritas 5U84 Primary Storage Shelf uses dual, hot swappable RAID Controllers. These controllers create and manage the 5U84 Primary Storage Shelf disk drive RAID arrays that contain backed up data. They also create and manage the RAID disk drive arrays on 5U84 Expansion Storage Shelves when those are attached to the 5U84 Primary Storage Shelf. 1

The 5U84 Primary Storage Shelf can continue to operate with only one functioning RAID Controller. But if both RAID Controllers are faulty the shelf must be powered off before you replace the controllers. Although you must have access to the rear panel of the 5U84 Primary Storage Shelf, it is not necessary to remove the shelf from the rack to replace the RAID Controller. Note: Always ensure that one RAID Controller per 5U84 Primary Storage Shelf is functional before attempting to remove and replace any faulty RAID Controller within a 5U84 Primary Storage Shelf. Do not remove a faulty RAID Controller unless you can immediately install a replacement RAID Controller. The system must not operate for long period of time without all RAID Controllers in place to provide adequate cooling to the Storage Shelf internal components. Requirements Use the following to verify the requirements of the service. Hot-swappable RAID Controller Cable labels ESD wrist strap Removing the faulty RAID Controller Use the following procedure to remove the faulty RAID Controller. To remove the faulty RAID Controller 1 Check the Module Fault LED on the front of the Storage Shelf. At the front of the Storage Shelf, an Operator Panel located on the left-hand storage shelf ear displays any fault information using a series of LEDs. The middle LED should be amber, indicating that a module fault exists. 2

2 Identify the RAID Controller to be removed. If the controller has failed, the fault LED will be lit amber. 3 Make a note of the locations of the cables before removing them from the RAID Controller. A RAID Controller uses fiber cables. It may also have a SAS3 cable attached to it if there is a 5U84 Expansion Storage Shelf as part of the 5340 Appliance system. Label and disconnect any cables connected to the controller. Label each cable to facilitate re-connection to the replacement RAID Controller. 4 Pinch the latch on the module and pull the handle towards you. This levers the module out of its connector on the midplane. 3

Note: Do not disturb other SAS3 cables if there are multiple storage shelves installed as part of the 5340 Appliance system. 5 Swing the latch handle open, grip the latch handle and ease the RAID Controller forward from the slot. 6 Place both hands on the module body, and pull it straight out of the enclosure such that the RAID Controller remains level during removal. 7 Place the faulty RAID Controller in an ESD-preventative bag. Installing the replacement RAID Controller Use the following procedure to install the replacement RAID Controller. To install the replacement RAID Controller 1 Slide the replacement RAID Controller into the chassis. To insert a replacement RAID Controller, rotate the replacement RAID Controller so that the release latch is at the bottom. Open the release latch and rotate it to its most open position. Slide the replacement RAID Controller into its slot until it will go no further and the handle has started to close. 2 Close the latch until it clicks home. 4

3 Connect the cables to the replacement RAID Controller. Note: Refer to the labels and any notes you made before you removed the cables from the defective RAID Controller. 4 Verify that the LED illuminates green. 5 If the LED is not green, call Veritas Technical Support. 5