Product Overview. Switch Models CHAPTER

Similar documents
Product Overview. Switch Model CHAPTER

Product Overview. Switch Descriptions. Front Panel CHAPTER

Catalyst 2960-X and 2960-XR Switch Hardware Guide

Product Overview. Features CHAPTER

Overview. Features CHAPTER

Product Overview. Switch Models CHAPTER

Cisco CGS 2520 Hardware Installation Guide

Product Overview. Switch Model

Product Overview. Switch Features Overview CHAPTER

Cisco IE 3010 Switch Hardware Installation Guide

Product Overview. Features CHAPTER

Overview. Switch Features CHAPTER

Advanced security capabilities like ETA, MACSec-256 and TrustWorthy systems.

Numerics INDEX. 10/100/1000 ports cable lengths 2-4, B-6 connecting to 2-38, B-43 described /100 ports

Product Overview. Introduction. Hardware Features CHAPTER

Configuring Interface Characteristics

Installing and Upgrading Internal Modules and FRUs

New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches

Troubleshooting. Diagnosing Problems. Verify the Switch Module POST Results CHAPTER

Numerics INDEX. cables caution 1-19 cabling

Troubleshooting. Diagnosing Problems CHAPTER

Configuring Interface Characteristics

Troubleshooting. Diagnosing Problems. Check Switch POST Results CHAPTER

Connecting Cisco EtherSwitch Service Modules to the Network

Cisco ME 3800X and ME 3600X Switch Hardware Installation Guide

Connector and Cable Specifications

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Troubleshooting. Diagnosing Problems. Verify Switch Module POST Results. Verify Switch Module LEDs CHAPTER

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

Product Overview. Cisco ME 6524 Ethernet Switch (ME-C6524GS-8S) CHAPTER

FSM-510G Series Ethernet Management Switch Quick Start Guide

Cisco Etherswitch Service Modules

Preface. Managed Media Converter Chassis System

Switch Installation. Preparing for Installation. Safety Warnings

Cisco Series Gigabit Ethernet Half-Height Line Card

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Industrial 8-Port 10/100/1000T + 2-Port 100/1000X SFP Ethernet Switch (-40~75 degrees C)

Cisco EtherSwitch 4- and 9-Port High-Speed WAN Interface Cards Datasheet

Product Overview. Switch Features. Catalyst 4503 Switch Features CHAPTER

INDUSTRIAL POE SWITCH

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

Supported Hardware Components

8~14-Port Managed Ethernet Switch

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Installation Notes for the Catalyst 3750-X and 3560-X Network Modules

NVT Phybridge, Inc Superior Court, Unit 3 Oakville, ON, L6L 0C4 Phone: Web:

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Switch Installation. Preparing. Safety Warnings CHAPTER

Catalyst 2960-X and 2960-XR Switch Hardware Installation Guide

4 PWR XL: Catalyst 3524 PWR XL Stackable 10/100 Ethernet

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

1000Base-SX / LX to 10/100/1000Base-T 802.3at PoE Industrial Media Converter

Interface and Hardware Components Configuration Guide, Cisco IOS XE Everest 16.6.x (Catalyst 9300 Switches)

Fast Ethernet Port Adapter Family (PA-2FE) For Cisco 7200, 7300, 7500 and 7600 Series Routers

Installation Notes for the Cisco TwinGig and OneX Converter Modules

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

PHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X

PHB-200M PHB x 100/1000Base-T to 20x100/1000Base-X SFP Patching Hub

Quick Start Guide Elinx ESW500 Series. Managed Din Rail Ethernet Switch

Installation. Package Contents CHAPTER

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Catalyst 3850 Switch Hardware Installation Guide

IEC /IEEE 1613 Lite L3 Hardened Managed 24-port Gigabit SFP. 10GbE Connectivity Four 10G SFP+ for connecting the switch to the core network

Chapter 2. Switch Concepts and Configuration. Part I

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

MS400870M. User's Guide. Ver.: Port GBE SFP Switch 19 1U 24x10/100/1000T Combo 10/1000X SFP

Cisco Industrial Ethernet 3010 Series Switches Layer 2/Layer 3

Quick Start Guide. Physical Description. The Port Status LEDs

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

Catalyst 2360 Switch Getting Started Guide

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

Troubleshooting 1240AG Series Lightweight Access Points

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Cisco Catalyst Express 520 Series Switches

Configuring Interface Characteristics

Release Notes for the Cisco ESS 2020 Switch, Cisco IOS Release 15.0(2)EC and Later

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

Industrial Din Rail Ethernet Switch

Cisco Industrial Ethernet 3010 Series Switches Layer 2/Layer 3

10 Gigabit Ethernet Copper-to-Fiber Media Converter - Open SFP+ - Managed

Ethernet Cards. 5.1 Card Overview CHAPTER

Industrial 8-Port 10/100TX 802.3at PoE+ + 2-Port Gigabit TP/SFP Combo Ethernet Switch IFGS-1022HPT. User s Manual

PT-7728/7828 Quick Installation Guide

PHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X FE/GbE Media Converter Concentrator

Installing the ASA 5550

Gigabit Ethernet Industrial Switch 10 Port with Ring- Redundancy and PoE

SW-UNM-24FE2GC-24POE 24 Fast Ethernet Ports PoE + 2 Giga Combo User Manual Ver 1.1

IPS-3110 Managed Industrial PoE Gigabit Ethernet Switch

00 ch6.ai 2010/12/16 W È 11:17:02 Ethernet Switches 6.1 Overview P Product Showcase P6-2-1

Industrial and Industrial Hardened Managed PLUS non-poe and PoE switch range

Switched Uplink Modules

Gigabit Ethernet Industrial Switch 10 Port with Railway and Power Substation Certification

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555

Introduction to the Catalyst 3920

Connector and Cable Specifications

LNX-1002C-SFP Series

PHB-200M/PHB x 100/1000Base-T to 20x100/1000Base-X SFP Patching Hub

Configuring the Switch

Transcription:

CHAPTER 1 The Cisco CGS 2520 switches, also referred to as the switch, are Ethernet switches that you can connect devices such as Intelligent Electronic Devices (IEDs), distributed controllers, substation routers, Cisco IP Phones, Cisco Wireless Access Points, and other network devices such as redundant substation switches. This chapter contains the following topics: Switch Models, page 1-1 Cable Side, page 1-2 Power Supply Side, page 1-11 Management Options, page 1-13 Switch Models Note The information in this document regarding China switches (part numbers ending with -C, for example, PWR-RGD-AC-DC-C) are identical to the non-china switches, except where specified. Table 1-1 Switch Models Model Cisco CGS-2520-24TC Cisco CGS-2520-24TC-C Description 24 10/100 FastEthernet ports, two dual-purpose ports (two 10/100/1000BASE-T copper ports and two SFP 1 module slots), and two AC and DC power supply module slots. (For China) 24 10/100 FastEthernet ports, two dual-purpose ports (two 10/100/1000BASE-T copper ports and two SFP module slots), and two AC and DC power supply module slots. Cisco CGS-2520-16S-8PC 16 100BASE-FX SFP-module slots; eight 10/100 FastEthernet PoE 2 ports, two dual-purpose ports (two 10/100/1000BASE-T copper ports and two SFP module slots), and two AC and DC power supply module slots. Cisco CGS-2520-16S-8PC-C (For China) 16 100BASE-FX SFP-module slots; eight 10/100 FastEthernet PoE ports, two dual-purpose ports (two 10/100/1000BASE-T copper ports and two SFP module slots), and two AC and DC power supply module slots. 1-1

Cable Side 1. SFP = small-form-factor pluggable. 2. PoE = Power over Ethernet. Cable Side The 10/100 Fast Ethernet downlink ports in Figure 1-1 are grouped in pairs. The first member of the pair (port 1) is above the second member (port 2) on the left. Port 3 is above port 4, and so on. The dual-purpose ports are numbered 1 and 2. Figure 1-1 Cisco CGS-2520-24TC Cable-Side View 1 3 5 6 7 8 Cisco CGS 2520 207196 2 4 9 1 SD 1 flash memory card slot 6 RJ-45 console port 2 LEDs 7 USB (mini-type B) console port 3 Express Setup button 8 Power-input terminal 4 10/100 ports 9 Alarm port 5 Dual purpose ports 1. SD = Secure Digital The100BASE-FX SFP ports and the 10/100 PoE ports are grouped in pairs. The first member of the pair (port 1) is above the second member (port 2) on the left. Port 3 is above port 4, and so on. The dual-purpose ports are numbered 1 and 2. 1-2

POWER OVER ETHERNET Cable Side Figure 1-2 Cisco CGS-2520-16S-8PC Cable-Side View 1 3 5 6 7 8 9 POWER OVER ETHERNET Cisco CGS 2520 207197 2 4 10 1 SD flash memory card slot 6 Dual purpose ports 2 LEDs 7 RJ-45 console port 3 Express Setup button 8 USB (mini-type B) console port 4 100BASE-FX SFP ports 9 Power-input terminal 5 10/100 PoE ports 10 Alarm port 10/100 Fast Ethernet Ports You can set the 10/100 ports on the switch to operate in any combination of half duplex, full duplex, or 10 or 100 Mb/s. You can set the ports for speed and duplex auto-negotiation. The default setting is auto-negotiate. When set for auto-negotiation, the switch determines the speed and duplex settings of the attached device, and advertises its own capabilities. If the connected device also supports auto-negotiation, the switch negotiates the best connection (the fastest line speed that both devices support and full-duplex transmission if the attached device supports it), and configures itself accordingly. In all cases, the attached device must be within 328 feet (100 meters). PoE Ports Warning Voltages that present a shock hazard may exist on Power over Ethernet (PoE) circuits if interconnections are made using uninsulated exposed metal contacts, conductors, or terminals. Avoid using such interconnection methods, unless the exposed metal parts are located within a restricted access location and users and service people who are authorized within the restricted access location are made aware of the hazard. A restricted access area can be accessed only through the use of a special tool, lock and key or other means of security. Statement 1072 The 10/100 PoE ports on the Cisco CGS-2520-16S-8PC-C switches provide PoE support for devices that are compliant with IEEE 802.3af. The Cisco prestandard PoE is also supported for Cisco IP Phones and Cisco Aironet Access Points. The PoE ports on the switch deliver up to 15.4 W of PoE. Any four of the eight ports are designated as high priority PoE ports, while other four ports are designated as low priority 1-3

Cable Side PoE ports. When both the power supply modules are installed, the system has enough power to support all the eight ports as PoE ports. In case one of the power supply module fails, the power to the low priority PoE ports is dropped, while power to the high priority PoE ports remains uninterrupted. On a per-port basis, you control whether or not a port automatically provides power when an IP phone or an access point is connected. The 10/100 PoE ports use RJ-45 connectors with Ethernet pinouts. The maximum cable length is 328 feet (100 meters). The 100BASE-TX and 1000BASE-T traffic requires Category 5, Category 5e, or Category 6 unshielded twisted pair (UTP) cable. The 10BASE-T traffic can use Category 3 or Category 4 UTP cable. For information about configuring and monitoring PoE ports, see the switch software configuration guide on Cisco.com. For information about port connections and port specifications, see the Connecting Devices to the Ethernet Ports, page 2-24 and the Connector and Cable Specifications, page B-1. Note The output of the PoE circuit has been evaluated as a Limited Power Source (LPS) per IEC 60950-1. Dual-Purpose Ports SFP Modules You can configure the dual-purpose ports on the switch as either 10/100/1000 ports or as SFP-module ports. You can set the 10/100/1000 ports to autonegotiate, or you can configure them as fixed 10, 100, or 1000 Mb/s (Gigabit) Ethernet ports. By default, the switch selects the medium for each dual-purpose port (10/100/1000BASE-T or SFP). When a link is achieved on one media type, the switch disables the other media type until the active link goes down. If links are active on both media, the SFP-module port has priority, but you can use the media-type interface configuration command to manually designate the port as an RJ-45 port or an SFP port. You can configure the speed and duplex settings consistent with the selected media type. For information on configuring interfaces, see the switch software configuration guide. The switch Ethernet SFP modules provide connections to other devices. These field-replaceable transceiver modules provide the uplink interfaces.the modules have LC connectors for fiber-optic connections or RJ-45 connectors for copper connections. You can use any combination of the supported SFP modules listed in Table 1-2. 1-4

Cable Side Table 1-2 Maximum Operating Temperature Type of SFP Module Rugged and Industrial SFPs 40 to 140 F ( 40 to 60 C) Commercial SFPs 32 to 113 F (0 to 45 C) Extended temperature SFPs 23 to 140 F ( 5 to 60 C) Model GLC-SX-MM-RGD GLC-LX-SM-RGD GLC-FE-100LX-RGD GLC-FE-100FX-RGD GLC-ZX-SM-RGD GLC-BX-D with DOM support GLC-BX-U with DOM support GLC-FE-100LX GLC-FE-100BX-D GLC-FE-100BX-U GLC-FE-100FX GLC-FE-100EX GLC-FE-100ZX CWDM SFP with DOM support SFP-GE-L with digital optical monitoring (DOM) support SFP-GE-S with DOM support SFP-GE-Z with DOM support GLC-EX-SMD with DOM support For information about SFP modules, see your SFP module documentation and the Installing and Removing SFP Modules, page 2-19. For cable specifications, see SFP Module Cables, page B-4 SFP Module Patch Cable The switch uses an SFP-module patch cable, a 0.5-meter, copper, passive cable with SFP module connectors at each end (see Figure 1-3). The patch cable connects two switches in a cascaded configuration. Figure 1-3 SFP-Module Patch Cable 126809 See the Inserting and Removing the SFP Module Patch Cable, page 2-21 for information about using the SFP module patch cable. You can order this cable (part number CAB-SFP-50CM=). 1-5

Cable Side Power-Input Terminal The power-input terminal provides screw terminals for the AC and DC power connections. The switch can operate with one or two power supplies. If one of the power sources fail, the other continues to power the switch. See Power Supply Installation, page 3-1 for information. Figure 1-4 Power-Input Terminal Cisco CGS 2520 207234 Alarm Ports The switch has four alarm inputs and one alarm output. The alarm setting is open or closed. Open means that the normal condition has current flowing through the contact (referred to as a normally closed contact). The alarm is generated when the current stops. Closed means that no current flows through the contact (referred to as a normally open contact). The alarm is generated when the current flows. Alarm Input The alarm input is a dry-contact alarm port. You can connect up to four alarm inputs from devices, such as a door, a temperature gauge, or a fire alarm, to the alarm port. You can use the CLI to set the alarm severity to minor, major, or critical. An alarm generates a system message and turns on an LED. See Alarm LEDs, page 1-9 for the LED descriptions. Alarm Output The alarm output can be configured as a minor or major alarm. Output alarms often control an external alarm, such as a bell or a light. To connect an external alarm device to the relay, connect two relay contact wires to complete the electrical circuit. See Alarm Port, page B-3 for information on the alarm pinouts. Management Ports You can connect the switch to a PC running Microsoft Windows or to a terminal server through either the RJ-45 console port or the USB console port. RJ-45 console port. The RJ-45 connection uses an RJ-45-to-DB-9 female cable 1-6

Cable Side USB mini-type B console port (5-pin connector); the USB connection uses a USB Type A-to-5-pin mini-type B cable The USB console interface speeds are the same as the RJ-45 console interface speeds. To use the USB console port, you must install the Cisco Windows USB device driver on the device that is connected to the USB console port (device running with Microsoft Windows). Note For information about downloading the Cisco USB device driver, see the Installing the Cisco Microsoft Windows USB Device Drivers, page C-4. With the Cisco Windows USB device driver, connecting and disconnecting the USB cable from the console port does not affect Windows HyperTerminal operations. Mac OS X or Linux require no special drivers. Note The 5-pin mini-type B connectors resemble the 4-pin mini-type B connectors. They are not compatible. Use only the 5-pin mini-type B. See Figure 1-5. Figure 1-5 USB Mini-Type B Port 253163 The configurable inactivity timeout reactivates the RJ-45 console port if the USB console port is activated, but no input activity occurs on it for a specified time period. When the USB console port deactivates due to a timeout, you can restore its operation by disconnecting and reconnecting the USB cable. For information on using the CLI to configure the USB console interface, see the switch software guide. LEDs You can use the switch system and port LEDs to monitor switch activity and performance. 1-7

Cable Side Switch Panel LEDs Figure 1-6 Switch LEDs (Cable Side) 1 2 3 4 5 6 7 8 9 10 11 12 13 207198 14 15 16 1 SYS (system) 9 OUT (alarm output) 2 CON (console) 10 PSU1 (power supply 1) 3 USB 11 PSU2 (power supply 2) 4 SD (SD flash memory card) 12 PoE 1 5 IN1 (alarm input 1) 13 Express Setup button 6 IN2 (alarm input 2) 14 Ethernet ports 7 IN3 (alarm input 3) 15 SFP module port 8 IN4 (alarm input 4) 16 10/100/1000 port 1. Only on the Cisco CGS-2520-16S-8PC switch. System LED Table 1-3 System LED Color System Status Off System is not powered on Blinking green POST 1 is in progress Green System is operating normally Amber System is receiving power but is not functioning properly 1. POST = power-on self-test. 1-8

Cable Side Power Supply Module LEDs The switch power supply module LEDs are labeled PSU1 and PSU2 (on the switch) and PSU OK (on the power supply module). They show whether power supply modules 1 and 2 are receiving power. See Figure 1-6 and Figure 1-9. Table 1-4 Color Off Green Red Blinking red Power Supply Module LEDs System Status Power supply module (1 or 2) is not installed Valid input is present, and the output is within the operating range Valid input is present, and the output is outside the operating range or is not present Valid input is not present Alarm LEDs Table 1-5 Color Off Amber Red Blinking red Alarm Input LEDs System Status No alarm Minor alarm Major alarm Critical alarm Table 1-6 Color Green Red Alarm Output LED System Status No alarm Relay closed, alarm present Console LEDs The console LEDs show which console port is in use. See Figure 1-6 and Figure 1-9 for the LED locations. If you connect a cable to a console port, the switch automatically uses that port for console communication. If you connect two console cables, the USB console port has priority. Table 1-7 RJ-45 and USB Console Port LEDs LED Color Description RJ-45 console port Green RJ-45 console port is active.; USB console port LED is off Off Port is not active; USB console port is active USB console port Green USB console port is active; RJ-45 console port LED is off Off Port is not active; RJ-45 console port is active 1-9

Cable Side Port LEDs RJ-45 ports and SFP-module slots have port LEDs. Port LEDs, as a group or individually, provide information about the switch and about the individual ports. Table 1-8 LED Color Off Green Blinking green Alternating green-amber Amber Meaning of Port LED Colors Meaning No link or port was administratively shut down Link present but not sending or receiving data Activity. Port is sending or receiving data Link fault. Error frames can affect connectivity, and errors such as excessive collisions, CRC errors, and alignment and jabber errors are monitored for link faults Port is blocked by Spanning Tree Protocol (STP) and is not forwarding data. After a port is reconfigured, the port LED is amber for up to 30 seconds as STP searches for loops. PoE LED Table 1-9 PoE LED Color Off Green Alternating green and amber Blinking amber Amber Meaning Not enabled Enabled and ports are functioning correctly Enabled but power is disconnected or has failed on a low-priority port Enabled but power is disconnected or has failed on a high-priority port Enabled and a PoE circuit failure is detected Dual-Purpose Port LEDs The dual-purpose port LEDs identify the connection as either a copper-based connector or an SFP module. The ports can autonegotiate, or you can manually configure each dual-purpose port as either 10/100/1000 with copper connectors or as an SFP-module port, but not as both types at the same time. See Table 1-8 for LED descriptions. SD Flash Memory Card LED Table 1-10 SD Flash Memory Card LED Color Off / blinking green Blinking amber System Status Transfer in progress Not present (slow blinking); unsupported SD flash memory card is detected (fast blinking) 1-10

Cisco Connected Grid Switch 2500 Series Power Supply Side Table 1-10 Color Amber Green SD Flash Memory Card LED (continued) System Status Error accessing the SD flash memory card; Cisco IOS boot image cannot be found SD flash memory card is functioning SD Flash Memory Card The switch ships with the Secure Digital (SD) flash memory card installed. See Figure 1-1 and Figure 1-2. You can remove the card from a failed switch and install it in a replacement switch. You do not have to reconfigure the new switch. See the Replacing the SD Flash Memory Card, page 2-22 for information. Warning Be aware that the SD card contains sensitive and security relevant information, including but not limited to full device configuration information, public and private keys used for SSH and SSL (if those protocols are enabled), device passwords and others. Access to SD cards for any Cisco CGS switch should be limited to authorized personnel. Power Supply Side The power supply side has the LED panel and two power supply slots for the removable power supplies. See Figure 1-7 and Figure 1-8. Figure 1-7 Switch with One Power Supply Module 1 2 PWR-RGD-LOW-DC 207200 3 1 LED panel Power supply slot 1 3 Power supply slot 2 1-11

Cisco Connected Grid Switch 2500 Series Power Supply Side Figure 1-8 Switch with Both Power Supply Modules PWR-RGD-LOW-DC 1 PWR-RGD-LOW-DC 1 207230 1 PSU OK LED For a description of the PSU OK LED, see Table 1-4 on page 1-9. Power Supply-Side LEDs Figure 1-9 Switch LEDs 1 2 3 4 5 6 7 8 9 10 11 12 Cisco Connected Grid Switch 2500 Series 207199 13 14 15 1 SYS (system) 9 OUT (alarm output) 2 CON (console) 10 PSU1 (power supply 1) 3 USB LED 11 PSU2 (power supply 2) 4 SD (SD flash memory card) 12 PoE 1 5 IN1 (alarm input 1) 13 Express setup button 6 IN2 (alarm input 2) 14 Ethernet port 7 IN3 (alarm input 3) 15 10/100/1000 port 8 IN4 (alarm input 4) 16 SFP port 1-12

Management Options 1. Only on the Cisco CGS-2520-16S-8PC switch. For a description of the LEDs, see LEDs, page 1-7. Power Supply Features The switch has two slots for power supply modules: PWR-RGD-LOW-DC: low-voltage DC (for voltage information, see Table A-6) PWR-RGD-AC-DC: high-voltage AC or DC (for voltage information, see Table A-5) PWR-RGD-AC-DC-C: high-voltage AC or DC for China The switch supports these power supply module combinations: Single low-voltage DC Single high-voltage AC or DC Two high-voltage AC or DC Two low-voltage DC One high-voltage AC or DC and one low-voltage DC For information on installing the power supply modules, see Power Supply Installation, page 3-1 See Table 1-4 for information on the power supply LEDs. Management Options Device manager You can use the device manager in the switch memory to manage standalone switches. For information, see the switch getting started guide and the device manager online help. Cisco IOS CLI You can configure and monitor the switch from the CLI. Connect your management station to the switch console port or use Telnet from a remote management station. See the switch command reference on Cisco.com for information. CiscoWorks application The CiscoWorks LAN Management Solution (LMS) is a suite of management tools that simplify the configuration, administration, monitoring, and troubleshooting of Cisco networks. See the LMS documentation for information: http://www.cisco.com/en/us/products/ps7198/tsd_products_support_series_home.html CiscoView application The CiscoView device-management application displays a switch image that you can use to view switch status and performance information and to set configuration parameters. The CiscoView application (sold separately) can be a standalone application or part of a Simple Network Management Protocol (SNMP) platform. For information, see the CiscoView documentation: http://www.cisco.com/en/us/products/sw/cscowork/ps4565/tsd_products_support_series_home.ht ml 1-13

Management Options Cisco Configuration Engine The Cisco Configuration Engine automates initial configurations and configuration updates. It generates device-specific configuration changes, sends them to the device, executes the configuration changes, and logs the results. For information about Cisco Configuration Engine, see the software configuration guide on Cisco.com. SNMP network management You can manage switches from a Simple Network Management Protocol (SNMP)-compatible management station that is running platforms such as HP OpenView or SunNet Manager. The switch supports a comprehensive set of Management Information Base (MIB) extensions and four Remote Monitoring (RMON) groups. See the switch software configuration guide on Cisco.com and the documentation that came with your SNMP application for information. Cisco Configuration Professional Configuration Professional is a software program that you download from Cisco.com and run on your PC. It offers advanced options for configuring and monitoring multiple devices, including the Cisco CGS 2520 switches. Configuration Professional is available at no cost: http://www.cisco.com/en/us/products/ps9422/index.html See the Configuration Professional getting started guide and online help for more information. Cisco Security Manager Cisco Security Manager (Security Manager) manages security policies on Cisco security devices. It supports integrated provisioning of firewall, IPS, and VPN (site-to-site, remote access, and SSL) services across devices. For information, see the User Guide for Cisco Security Manager 3.2.2. Catalyst Smart Operations The Smart Install feature provides a single point of management (director) in a network. You can use it to provide a zero touch image and configuration upgrade of newly deployed switches and image and configuration downloads for any client switches. For information, see the Cisco Smart Install Configuration Guide on Cisco.com. The Smartports feature provides user-defined and Cisco-default macros for creating custom switch configurations to simplify deployment. For information about configuring Smartports, see the switch software configuration guide on Cisco.com. Network Configurations See the switch software configuration guide on Cisco.com for an explanation of network configuration concepts. The software configuration guide also provides network configuration examples for creating dedicated network segments that are interconnected through Ethernet connections. 1-14