_A_en_LED63VG VOICE GUIDE KEYPAD LED63VG

Similar documents
LCD62. Keypad. User Manual

CA62 User s Manual - Operation with LED62 Keypad and PR62 Proximity Cards Reader. English

SIGMA "APOLLO" APOLLO User Manual Page 1

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...

IDS X-Series User Manual E Issued June 2013

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

ELECTRONIC ENGINEERING LTD. OLED Keypad. User s Guide. P/N: Doc Rev-A SW Ver /08/10

2 IDS LCD Keypad User Manual C Issued March 2009

INT-KSG Keypad Quick user s guide

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

INT-KSG Keypad Quick user s guide

SK-1011-SQ Digital Access Keypad with 5A Relay Output

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

SpeedVault Model SV 500 User Manual

Agility 2-Way Wireless Slim Keypad

AMAX panel. AMAX panel 2100 AMAX panel 3000 AMAX panel 3000 BE AMAX panel en Operation Manual

Quick Start Installation Guide

Automatic Phone-Out Home Monitoring System

PC-LC2/ QUICK INSTALL GUIDE. Installation Guide. Version 1.0. Technical Manuals Online! -

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

Installation Manual GENERAL DESCRIPTION...2 WIRING INFORMATION FOR NX-507 AND NX NX-507 TERMINAL DESCRIPTION...3 NX-507 DRAWING...

NX1700EIB02 (Supercedes NX1700EIA02) NetworX Series. NX-1700E Proximity Card Reader Installation and Startup

FastForward User Guide

FastForward TM User Guide

VoiceNav User Manual

1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads...

Series. NX-8-EUR Control Panel. Installation manual

DAS ALPHA NUMERIC LCD CODEPAD INSTALLATION MANUAL

NX-148 LCD KEYPAD INSTALLATION MANUAL

Digital Electronic Lock OWNER S MANUAL

User Guide. Control Box. RoscoLED TM.

Installation Manual IMPORTANT NOTE

212iL Rev. 1.1

User s manual. Evolution Multimedia device for domotic control in SmartLiving systems User s manual

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

SECURITY MODULE CG3 User Manual

FW2 MERLIN PRO Manual ==============================

LCD User Station User Manual

IDS1200 INSTALLER MANUAL. Summary of Operation 2 IDS1200 INSTALLER MANUAL - NO B ISSUED AUGUST 2002 VER 1.18

NAPCO iseevideo Fixed IP Camera User Guide

Table of Contents. Phone number configuration...15 Alarm Phone numbers, 1, 2 & Divert phone numbers 1, 2 &

Mold Control Systems, Inc.

Keypad LCD (software version 3.10) CA-10 plus

SATA II HDD Canister KISS DA 435 Quick Reference Guide

MULTIPLEXER MX4. Operation and Installation Manual. Pacific Micro Systems

Safecom Solution-16 Quick Reference Guide ISSUE 1.10

PROGRAMMING HELP GUIDE

Model P4470 Save A Watt Operation Manual

High Security and Access System EVO48 V2.1 EVO192 V2.1

Important Notice. Customer Information. 2 WisDom User Manual

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

Wireless Expansion Module V2.0 OMN-RCV3. Reference & Installation Manual. Stand-Alone System

Property of Monitronics Inc

REMOTE KEYPAD with NFC Tag (KPT-32N, KPT-32N-F1)

ASCL1 / ASCL2 CarLink Guide for Android Users

PROGRAMMING AND INSTALLATION MANUAL

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

P4472 Save A Watt HD Operation Manual

Keypad LCD-L (software version 3.10) CA-10 plus

Bluetooth Stereo Headset

PWRguard PLUS Spring City Drive Waukesha, WI

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

K44 Code lock. Technical manual

VISTA-128BP/VISTA-250BP Programming Form

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

ADVANCED 4/8-PORT SECURE KM SWITCH

USER MANUAL TP TP TP Expandable serial alarm systems. Release: 3.1

Solution 16 plus. User Guide Security System

Xxxxx Xxxxxx DC Voltage Data Logger

SOFTWARE VERSION 3.3. CD P/N Rev. C

INSTALLATION INSTRUCTIONS

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

EUROPLEX TECHNOLOGIES. WARNING. Copyright. Disclaimer

TanTime Systtem Timer Operation Instructions

DOLXFD1000B. Waterproof Access Control/Reader

Security System User Guide

Models VSP12824V & VSP12860V

QUICK START GUIDE.

Trilogy DL5200 Programming Instructions OI345 10/08

V-9908 MESSAGE/PAGE PANEL

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

Modules Programming Guide. paradox.com

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

USER MANUAL. 26-inch LED Scrolling Messenger Display INSTALLATION: NOTE: READ BEFORE PROGRAMMING YOUR MESSENGER: To START your messenger:

Property of Monitronics Inc

SA-59. GSM Communicator. Installation Manual

QUICK CONSUMER REFERENCE GUIDE

ASCL1 / ASCL2. CarLink Guide for BlackBerry Users Audiovox Electronics Corporation. All rights reserved.

Multiple-User Mode Operating Guide for Lock Models 2006 and 2007

4XLFN6WDUW*XLGH. LYNXR is not intended for UL985 Household Fire applications.

Troubleshooting Tips & Procedures. Model 8800 series. GeoNet Wireless

Owner s Instruction Manual

ISEE-SCHGW User Guide

Transcription:

18020502_A_en_LED6VG VOICE GUIDE KEYPAD LED6VG

Disclaimer While every effort has been made to ensure that the information in this manual is accurate and complete, no liability can be accepted for any errors or omissions. The manufacturer reserves the right to change the specifications of the equipment described in this manual without notice. This document contains information proprietary to the manufacturer. No part of this publication may be reproduced, photocopied, stored on a retrieval system or transmitted, without prior written permission of the manufacturer. Tamper J2 J1 J0 Wire opening GREEN YELLOW RED BLACK JT GND INPUT 2 Figure 2. Back Cover 2

Real time clock adjustment key sequence: PRG 9 COR- REC- TION 7 (2 beeps) Jumper Settings Address J0 J1 J2 JT 0 0 0 0 1 1 0 0 1 0 2 0 1 0 0 0 1 1 0 4 1 0 0 0 5 1 0 1 0 6 1 1 0 0 7 1 1 1 0 Contents Disclaimer 2 General Information 4 Limited Warranty 4 Warnings 4 Overview 5 Sound Indication 5 Voice Messages 5 LED Indication 7 Keypad 7 Operation 8 Arming 8 Full 8 Stay 8 Force 9 Instant 9 Panic 10 Disarming 10 Stopping the Alarm 11 Ambush Code 11 User Level Programming 11 User Code Change 12 Bypassing 12 Technical Troubles Review 12 Events Memory Review 1 Chime Enable/Disable 15 Manager Level Programming 16 Manager Code Change 16 Changing User Code/Rights 17 Events Memory Review 19 Chime Enable/Disable 19 Bypassing 20 Setting the Clock 20 Setting the Date 20 Adding a Proximity Card 21 Removing a Proximity Card 21 Real Time Clock Adjustment 21 Jumper Settings 22 22

General Information Limited Warranty The manufacturer warrants that for period of 12 months from the date of purchase, the product shall be free of defects in material and workmanship under normal use and that in fulfillment of any breach of such warranty, the manufacturer shall, at his discretion, repair or replace the defective equipment upon returning it to its factory. This warranty shall apply to defects in parts and workmanship only and not to damages incurred during shipping or handling, nor due to causes beyond the control of the manufacturer such as lightning, excessive voltage, mechanical shock, or damages arising from abuses, unauthorized alternations or misuse of the equipment. The warranty shall apply to the original buyer only, and is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of the manufacturer. This warranty contains the entire warranty. The manufacturer shall neither assume, nor authorizes any other warranty or liability concerning this product. In no event shall the manufacturer be liable for any direct or indirect or consequential damage, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation or operation or failure of this product. The manufacturer recommends that the entire system be completely tested on a regular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electrical disruption, it is possible for this product to fail to perform as expected. Warnings Before using the LED6VG Keypad, please make sure that you have read and understood the following instructions. Always make sure that the LED6VG Keypad is operated correctly. Do not attempt to disassemble or alter any part of the equipment that is not expressly described in this guide. Internal inspections, alterations and repairs should be conducted by qualified service personnel only. Do not use substances containing alcohol, benzene, thinners or other flammable substances to clean or maintain the equipment. The use Adding a Proximity Card To use proximity cards the system has to be equipped with a proximity card reader. Key sequence for adding a proximity card: PRG 6 USER ID 0 (2 beeps) (00-16) The card must be positioned near the card reader. Removing a Proximity Card The key sequence for removing a proximity card: PRG 6 USER ID 1 (2 beeps) (00-16) Real Time Clock Adjustment Arbitrary units are used for real time clock adjustment. One unit corresponds to every 5 seconds deflection per month. The value of 50 means there is no need for adjustment. The following method is used to calculate the necessary adjustment. The necessary adjustment is calculated by determining the number of days taken for the clock to deflect by 1 minute. The adjustment value is found by dividing the number 60 by the number of days found in the previous step. The result obtained is added to the current value in the case of a slow clock or is subtracted from the current value in case the clock runs fast. The figure thus obtained is entered into the system. Example: Let us suppose the clock is running slow by 1 minute in 85 days. The figure 4.2 is obtained when 60 is divided by 85. The adjustment value of 54 is obtained when the figure 4 is added to the current set figure of 50. 4 21

Bypassing To execute a bypass operation the manager is required to enter his personal code: PRG 4 0 Pressing a numeric key bypasses the respective zone. The display LED, corresponding to the zone number, lights up permanently. Pressing the same key once again de-bypasses the zone and the LED goes out. The selected programming is confirmed by pressing the key. Bypassing sequence (e.g. zone 2): 2 2 2 Setting the Clock To set the clock the manager is required to enter his personal code. The set entries are visualized in binary-hexadecimal form. Key sequence for setting the clock: PRG 5 NEW TIME 0 (2 beeps) (HHMM) Setting the Date To set the date the manager is required to enter his personal code. The set entries are visualized in binary-hexadecimal form. Key sequence for setting the date: PRG 5 NEW DATE 1 (2 beeps) (DDMM) of these substances may lead to fire. No liquids should enter the interior. Overview The LED6VG Keypad is designed to control the CA60Plus Control Panel and provides the user with system status information. The Control Panel is fully programmable with the LED6VG keypad. An LED indication on the keypad visualizes the system status and alarm events information. A sound buzzer informs the user about correct or incorrect key entries as well as activated alerts. Seven voice messages provide the user with addition information. Sound Indication There are seven different sound combinations that indicate seven different conditions: Click single short beep indicating the pressing of a key; Confirm two long sound signals, indicating the system confirmation to a successfully executed operation; Reject a single long beep, indicating an incorrectly executed operation; Entry time continuous beep, indicating intrusion into an entrance zone; Exit time short beeps, indicating the system is armed and the user is required to leave the entrance zone. Ten seconds before the exit time is over beep frequency increases; Technical problem two short beeps, indicating a technical problem; Chime short beeps with subsequently increasing frequency, indicating intrusion into a zone with an activated chime option; Voice Messages There are seven different voice messages that indicate different conditions: System is armed System is disarmed Please enter your code to disarm AC power is lost Battery is discharged Please leave the premises Alarm in the system 20 5

Zone LED Indicators Microspeaker Keypad LED Indicators Keypad Cover (open) NOTE: Forbidding all user permissions will automatically erase the programmed code combination. Events Memory Review To review event memory the manager is required to enter a valid personal code. Press event and one. MEM to for a previous for a following Press the key to see more information on a zone number or a user code. Information on the events, as well as the zone numbers and the users is presented in binary-hexadecimal form. Use the table on pages 14 and 15 to interpret them. Chime Enable/Disable To enable or disable chime mode the manager is required to enter a valid code. Chime enable/disable key sequence: PRG 0 Pressing any numeric key alternatingly switches state of chime on and off. The preferred state is confirmed by pressing the key. Figure 1. Frontal view of the keypad with the cover opened 6 19

Now the manager can switch over between code change mode and user permissions mode, using the and keys. Originally the system is in code change mode. LEDs, 4, 5 and 6 light up to indicate the number of code digits left to be entered. Disarm Full arm Stay arm Bypass Review event memory Force arm Pressing a numeric key alternatingly switches over the state of the respective operation from forbidden to permitted. Selection is confirmed by pressing LED Indication LED Light Blinking RDY (green) System ready Programming mode ARM (red) System armed Exit time / Programming mode TRBL (red) - Technical problem / Programming mode BPS (red) Bypassed zones - TAMP (red) Tamper memory Tamper MEM (red) Alarm memory Activated fire detector 1-6 (red) Alarm memory Activated zone detector The manager is expected to enter the new user code. Entering new user code key sequence: NEW (4 digits) (2 beeps) NEW (reenter) The new code is accepted and the system automatically enters user permissions mode. The LEDs indicate the respective operations the user is allowed to execute. The lit numbers indicate the permitted programs. the key. User permissions key sequence: Keypad ARM DISARM BPS TRBL MEM arms the system (See page 8) disarms the system (See page 10) bypasses certain zone(s) (See pages 12, 20) reviews system troubles (See page 12) reviews event memory (See page 1) PRG CLR activates programming mode (See pages 11, 16) clears entered data or transfers to previous menu level confirms entered data or transfers to next menu level scroll event memory (See pages 1, 19) 18 7

Operation Arming The system can be armed only if the green RDY1 LED is lit up. Full Full arming means all zones are secured. Anyone coming into the entrance zone is required to enter a code. Otherwise the alarm is triggered after entrance time is over. Full arming sequence: ARM 0 Quick full arming key sequence: ARM 0 The ARM1 LED lights up. Stay Stay arming means the user is allowed to stay in (a) certain zone(s), but the entrance zone is secured. Anyone coming into the entrance zone is required to enter a code. Otherwise the alarm is set off after the entrance time is over. Stay arming key sequence: ARM 1 Quick stay arming key sequence: ARM 1 The BPS LED lights up permanently on the display and the LEDs, corresponding to the numbers of the zones which are not armed, blink slowly. The new code has been accepted and the system automatically enters remote access permissions mode. The LEDs stand for the remote access allowable operations. The lit numbers indicate the permitted programs. Remote disarm Remote arm Remote code access Remote bypass Remote event memory review Remote programming Pressing a numeric key alternatingly switches over the state of the respective remote operation from forbidden to permitted. Remote access permissions key sequence: Changing User Code and Rights To change the user code, the manager is required to enter his personal code first before the user code. User code change key sequence: Pressing the key confirms the selection. PRG USER ID (01-16) (2 beeps) 8 17

Manager Level Programming As a rule of thumb you can enter user programming mode using the following procedure: Step 1: Enter valid user code Step 2: Press PRG once Step : Enter a parameter number (two digits - see address table) Step 4: Change parameter value Step 5: Press to confirm and CLR to reject changes. A blinking RDY1 LED indicates that the system is in programming mode. Manager Code Change The manager is required to enter his current personal code before changing it. Manager code change key sequence: PRG 0 0 (2 beeps) The manager can switch between code change mode and remote access permissions mode with the and keys. The system is originally in change code mode. LEDs, 4, 5 and 6 light up to indicate the number of code digits left to be entered. The manager is expected to enter the new code. Key sequence for entering new manager code: Force Force arming means the system is armed although in (a) certain zone(s) there may be obstacles or troubles. Forced arming key sequence: ARM 2 Quick forced arming key sequence: ARM 2 The BPS LED lights up and the LED s corresponding to the numbers of the zones which are not armed, blink slowly. Instant Instant arming means the user is allowed to stay in certain zone(s), but the entrance zone is secured. The difference with the stay arming is that intrusion into the entrance zone immediately sets on the alarm. Instant stay arming key sequence: ARM Quick instant stay arming key sequence: ARM The BPS LED lights up and the LEDs, corresponding to the numbers of the zones, which are not armed, blink slowly. NEW (4 digits) (2 beeps) NEW (reenter) 16 9

NOTE: With all arming modes, except Instant, after exit time starts running, the Please leave the premises voice message will sound every 5 seconds. The buzzer will indicate that exit time is running. Ten seconds before exit time is over, beep frequency will increase. After arming, the System is armed message will be repeated twice. After each of the procedures described above, except Instant, a blinking RDY1 LED also indicates that exit time is running and that the user is to leave the armed zones. In the events of AC loss and low battery, the AC power is lost or Battery discharged messages will sound correspondingly times every 5 seconds when arming is attempted. Panic Pressing and holding CLR + sends an alarm signal to the station without triggering the siren. Disarming If a person comes into the entrance zone, the voice message System is armed. Please enter your code to disarm. will sound every 5 seconds. The buzzer will indicate that entry time is running. The user is required to enter a personal code: After a valid code has been entered, the message System disarmed will be repeated twice. If no valid code has been entered during entry time, the System is armed message will sound. If an alarm has been triggered in the system, the message Alarm in the system. Please enter your code to disarm will be repeated every 5 seconds. NOTE: Certain users may not be allowed to disarm the system. In the events of AC loss and low battery, the AC power is lost or Battery discharged messages will sound correspondingly times every 5 seconds when disarming is attempted. Event Description Code 1 2 4 5 6 Zone/User Duress code entry 0 1 2 4 5 6 User Telephone line failure 1 1 2 4 5 6 0 Telephone line recovery 2 1 2 4 5 6 0 Communication error 1 2 4 5 6 0 Automatic test 4 1 2 4 5 6 0 Manual test 5 1 2 4 5 6 0 Fuse blown 6 1 2 4 5 6 0 Fuse recovery 7 1 2 4 5 6 0 System reset 8 1 2 4 5 6 0 Power supply failure 9 1 2 4 5 6 0 Power supply recovery 40 1 2 4 5 6 0 Battery low or missing 41 1 2 4 5 6 0 Battery recovery 42 1 2 4 5 6 0 Chime Enable/Disable To enable or disable chime mode the user is required to enter a valid code. Chime enable/disable key sequence: PRG Pressing any numeric key alternatingly switches state of chime on and off. The preferred state is confirmed by pressing the key. 10 15

Event Description Code 1 2 4 5 6 Zone/User Alarm activated 1 1 2 4 5 6 Zone number Alarm deactivated 2 1 2 4 5 6 Zone number Fire alarm activated 1 2 4 5 6 Zone number Fire alarm deactivated 4 1 2 4 5 6 Zone number Panic alarm activated 5 1 2 4 5 6 Zone number Panic alarm deactivated 6 1 2 4 5 6 Zone number Tamper alarm activated 7 1 2 4 5 6 Zone number Tamper alarm deactivated 8 1 2 4 5 6 Zone number Medical alarm activated 9 1 2 4 5 6 Zone number Medical alarm deactivated 10 1 2 4 5 6 Zone number Zone bypassed 11 1 2 4 5 6 Zone number Zone de-bypassed 12 1 2 4 5 6 Zone number Fire zone bypassed 1 1 2 4 5 6 Zone number Fire zone de-bypassed 14 1 2 4 5 6 Zone number Panic zone bypassed 15 1 2 4 5 6 Zone number Panic zone de-bypassed 16 1 2 4 5 6 Zone number Tamper zone bypassed 17 1 2 4 5 6 Zone number Tamper zone de-bypassed 18 1 2 4 5 6 Zone number Medical zone bypassed 19 1 2 4 5 6 Zone number Medical zone de-bypassed 20 1 2 4 5 6 Zone number Disarming 21 1 2 4 5 6 User Remote disarming 22 1 2 4 5 6 User Disarming by switch 2 1 2 4 5 6 Zone number Arming 24 1 2 4 5 6 User Remote arming 25 1 2 4 5 6 User Arming by switch 26 1 2 4 5 6 Zone number Quick arming 27 1 2 4 5 6 None Engineer menu entry 28 1 2 4 5 6 17 Engineer menu exit 29 1 2 4 5 6 17 Stopping the Alarm The alarm is stopped by entering a personal code: After a valid code has been entered, the message System disarmed will be repeated twice. NOTE: In the events of AC loss and low battery, the AC power is lost or Battery discharged messages will sound correspondingly times every 5 seconds. Ambush Code Ambush code is a personal code that disarms the system, but still sends an alarm signal. Its purpose to indicate that the user is forced to disarm the system against his/ her will. The ambush code is calculated from the personal code by adding 1 to the last digit. If the last number is 9, it is replaced by 0 in the ambush code. Example: Personal code: 4615 code: 4616 Personal code: 4619 code: 4610 Ambush Ambush After a code has been entered, the System disarmed message will be repeated twice. User Level Programming As a rule of thumb you can enter user programming mode using the following procedure: Step 1: Enter a valid user code Step 2: Press PRG once Step : Enter a parameter number (one digit - see address table) Step 4: Change parameter value Step 5: Press to confirm and CLR to reject changes. A blinking RDY1 LED indicates that the system is in programming mode. 14 11

User Code Change The user is required to enter his/ her current personal code before changing it. User code change key sequence: PRG 0 NEW beeps) NEW (4 digits) (2 (reenter) Bypassing To execute a bypass operation the user is required to enter a valid code: BPS. Pressing a numeric key bypasses the respective zone. The LED, corresponding to the zone number, lights up. Pressing the same key once again de-bypasses the zone and the LED goes out. The selected programming is con- Bypassing key sequence (zone 2 used in the example): 2 2 Technical Troubles Review To review troubles the user is required to enter a valid personal code: TRBL In the events of AC loss and low battery, the AC power is lost or Battery discharged messages will sound correspondingly times every 5 seconds. 2 AC lost Battery low or missing Fuse blown Tamper Communication error Phone line error Events Memory Review To review event memory the user is required to enter a valid personal code. MEM NOTE: Certain users may not be allowed to review event memory. Press event and one. to for a previous for a following Information on the events, as well as the zone numbers and the users is presented in binary-hexadecimal form. Use the table above to interpret them. For convenience the table also includes a graphic representation of the LEDs as they light up for the respective event. A black digit on white background indicates an extinguished LED, and a white digit on dark background indicates a lit up LED. Scroll from LED 1 to LED 6 to determine the correspondence between the event displayed on the keypad and the text in the table. The first 17 rows in the table are used for coding the user number and the zones. Example: Suppose that the event displayed on the keypad is represented by a LED combination of 2,, 5 and 6. The table discloses the first LED 2 data entry. The next data entries disclose that of the first LED. Next comes the first data entry of LED 5 and finally comes the first data entry of LED 6.This is the data entry with the ordinal number of 27 Quick arming. firmed by pressing. Each digit on the display indicates a specific technical problem. Press the key to see more information on a zone number or a user code. 12 1