FREQUENCY CONVERTER FC102 (QUICK GUIDE)

Similar documents
FREQUENCY CONVERTER FC101 (QUICK GUIDE)

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

User Guide VLT Parallel Drive Modules

Taco System Logic (TSL)

1 Extended and Advanced Cascade Controller Option 3

Safety Instructions 1-1 Avoid unintended Start General Description 2-2

AF-600 FP TM Fan & Pump Drive. (230V to 60HP, 460/575V to 125HP Operating Instructions

Metasys N2 Instruction Manual VLT Adjustable Frequency Drive. 12/ Revision B

Operating Instructions Extended Cascade Controller MCO 101

MAKING MODERN LIVING POSSIBLE. VLT AQUA Drive Cascade Controller Options MCO 101/102 Operating Instructions

Vacon HVAC100 Commissioning Guide

Control system for rotary heat exchanger EQRB, L=3,4

Installation Instructions

Installation and Wiring Instructions... 9

INGERSOLL RAND Fixed Speed/Variable Speed Conversion COMMISSIONING AND OPERATION MANUAL

AF-60 LP TM Micro Drive. Programming Guide

P216. Condenser fan speed controller. Product bulletin. Features

TPE, TPED Series 2000

EQ5 SERIES Quick Start Guide for Constant Torque Applications

Operating Instructions

MAKING MODERN LIVING POSSIBLE. Instruction VLT HVAC Basic Drive Cascade Controller

Genset control and protection with safety system

SMVector Additional I/O Module Installation and Operation Manual

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 2.00

Standard Cascade Controller Setup... 38

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

Modbus RTU Option Card for VLT 5000/6000 Adjustable Frequency Drive

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 1.10

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

MAKING MODERN LIVING POSSIBLE. Quick Guide. VLT HVAC Basic Drive Cascade Control *MG18F102*

Control D. Controller Module for Proportional Valve Control. Installation Manual

Optidrive Applications Support Library

Q9 ASD LOW VOLTAGE DRIVE

1. Safety Danger Warnings Earthing and earth fault protection... 4

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

NICOTRA Gebhardt EKE E-IM EKE E-IM S. Operating manual EC-Controller BA-EKE /2012

Operating Instructions

P216 Series Condenser Fan Speed Controller

Genset Controller Unit Model EMS - GC10. Installation Manual Section

WARNING ELECTRICAL SHOCK HAZARD

Setpoint Isolators. Technical Manual. HA Issue Parker SSD Drives, a division of Parker Hannifin Ltd. WARRANTY

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

Unidrive M400 (Frame 1 to 4) Quick Start Guide

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

MAKING MODERN LIVING POSSIBLE. Quick Guide VLT HVAC Basic Drive

RXTP ROOM TEMPERATURE

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

SMVector Additional I/O Module Installation and Operation Manual

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Optidrive Applications Support Library

I/O module (Expansion module)

1.1.1 Software Version Introduction About this Manual References 2

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

Voltsys Inverter Control Unit

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Operating Instructions. Modbus RTU VLT 2800 VLT 6000 VLT 8000

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Contents. Index 35. VLT HVAC Drive Metasys N2

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3

Digital DRIVE for Brushless motor MD Serial

RXTH DUAL ROOM SENSOR / SWITCH

PROGRAMMING MANUAL IM262R00. AQUAVAR Intelligent Pump Controller START-UP GENIE PROGRAMMING MANUAL

Tachometer Panel, PE3

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

isma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland

Optidrive VTC Modbus RTU Register Map

Metasys N2 Communications Protocol Operating Instructions

DeviceNet Drive Profile CFW-09

TR150 DRIVE STANDARD FEATURES

Supported Modbus RTU Function Codes... 26

OPERATING INSTRUCTION

Peristaltic Cased Tube Pump

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

1 How to Read these Operating Instructions 3. 3 Introduction to MCF 106 A/ B in C Option Adaptor 7

DIRIS D-30 DIRIS Digiware D-40 DIRIS Digiware D-50 Control and power supply interface

VLT 8000 AQUA. Installation. Mechanical installation

Programming Guide VLT BACnet/IP MCA 125

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

Power Connections: Basic Wiring:

PumpDrive. Self -cooling, motor-independent frequency inverter. Brief Instructions

MCH Series Drives Metasys N2 Communications Guide

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

TECO L510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

3GV M Modbus RTU Register Map

vacon 20 vacon 20 x vacon 20 cp ac drives modbus rtu user manual

DriveWare. User s Guide DriveConfig

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Issue 06

VLT 6000 Start-Up. Oct 2003

Compressor Controller MAM 890

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

HTTL Speed Feedback Communications Option

Voltsys Inverter Control Unit

TR200 DRIVE STANDARD FEATURES

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3

Transcription:

FREQUENCY CONVERTER FC102 (QUICK GUIDE) INSTALLATION AND MAINTENANCE Content Page Safety instructions 2 IT system 3x230VAC 2 Connections 3 Control unit (LCP) 4 Manual operation 4 Reverse the direction of rotation 4 More information 4 Wiring diagram 5 Basic configuration 6 PID regulation 7 FläktGroup DC_9325GB 20180202_R0 Specifications are subject to alteration without notice

2 Installation and maintenance SAFETY INSTRUCTIONS Check that the frequency converter is correctly connected to earth. Do not pull out the mains or motor contacts or other power connections when the frequency converter is connected to the power supply grid. Protect the user from mains voltage. Protect the motor against overload in accordance with national and local regulations. The leakage currents to earth exceed 3.5 ma, see Design guide. The [Off] button is not an isolator switch. It does not disconnect the frequency converter from the mains. WARNING! Warning high voltage The frequency converter is subject to highly dangerous voltages when it is connected to the mains. Incorrect installation of the motor or frequency converter can lead to material damage, serious personal injury or death. Follow the instructions in this manual as well as local and national provisions and safety regulations. Voltage (V) WARNING! Discharge time! Frequency converters have DC bus capacitors that can hold a charge even after the mains voltage has been disconnected. Prevent electrical hazards by disconnecting the mains voltage, disconnecting permanent magnet motors and DC bus supplies, including battery backup, UPS and DC bus connections for other frequency converters. Wait until the capacitors have fully discharged before carrying out maintenance or repairs. Read more about the discharge waiting times in the table below. Starting to service or repair the unit immediately after cutting the power supply, without waiting for the specified period, can lead to death or serious personal injury. Output range (kw) Minimum waiting time (min) 200 240 1.1 3.7 4 200 240 5.5 45 15 380 480 1.1 7.5 4 380 480 11 90 15 WARNING! Installation at heights For installation at height, contact FläktGroup regarding PELV. TAKE CARE! Residual current device: This product can cause a direct current in the protective earth conductor. When using a residual current device as additional protection, use only a type B residual current device (delayed) on the input side of this product. See also Danfoss application note for the MN90G RCD. The protective earthing of the frequency converter and the use of RCDs must always follow national and local regulations. TAKE CARE! IT system (3x230VAC) When installing the FC102 on an isolated system (IT system, 3x230VAC) set parameter 14-50 to [0] Off. Press [Main Menu] twice. Navigate using the [ ] [ ] and [OK] buttons until parameter 14 50 is displayed (select 14 **, then 14 5* and lastly 14 50). Set this parameter to [0] Off.

Installation and maintenance 3 CONNECTIONS PRINCIPLE IMAGE 1 2 3 130BB492.10 1 Control unit (LCP) 2 RS 485 serial bus 3 Analogue I/O 18 4 5 4 LCP contact 5 Analogue switches 6 Cable support/ PE earth 7 Earthing plate 8 Earth clamp 17 16 9 Shielded cable earth clamp and cable support 10 Motor connection 15 6 11 Relay 1 12 Relay 2 13 Brake and load distribution terminal 14 Mains connection 15 USB 8 7 16 Serial bus, terminal switch 8 17 Digital I/O and 24 V 14 14 9 18 Cover panel 13 12 10 11

Info 4 Installation and maintenance CONTROL UNIT (LCP) A. Alphanumeric display The information displayed in the control unit display (LCP) can be customised. See parameters 0 20, 0 21, 0 22, 0 23 and 0 24. The factory settings display: motor rpm, motor current, motor output, motor frequency and reference. B. Menu buttons Use the menu buttons to access the parameter settings, to toggle between status display modes during normal operation and to display fault log data. a a Status 1(1) 1234rpm 1.0 A 43,5Hz Run OK 43,5Hz C. Navigation and indication [Back] returns to the previous step or menu list [Cancel] Cancel the latest change or command [Info] Provides information of the function displayed [ ] [ ] [ ] [ ] navigate and increase/decrease [OK] Activate selection or access a parameter group b Status Back Quick Menu Main Menu Cancel Alarm Log Green indication power on Yellow indication warning Red indication alarm c c On Warn. OK D. Driftslägesknappar och återställning [Hand/on] Starting the motor for local control [Off] Stopping the motor [Auto/on] Allow control via control terminals or the communication bus [Reset] Resetting alarms d Alarm Hand on Off Auto on Reset MANUAL OPERATION Press [Hand/on] to start Press the navigation buttons to set the desired speed Press [Off] to stop Press [Auto/on] to return to automatic operation REVERSE THE DIRECTION OF ROTATION If necessary the direction of rotation can be reversed using parameter 1 06. When connection is correct 0=clockwise and 1=anti-clockwise. MORE INFORMATION This quick guide contains the basic information needed to install and operate the frequency converter. There is more information available in the attached documentation.

Installation and maintenance 5 WIRING DIAGRAM L1 L2 L3 N PE F1 91 92 93 95 L1 L2 L3 PE Danfoss FC102 +24V 12 +24V 13 DIG IN 18 DIG IN 19 COM 20 DIG IN 27 DIG IN 29 DIG IN 32 DIG IN 33 DIG IN 37 +10V 50 A IN 53 A IN 54 COM 55 A OUT 42 COM 39 R2 R1 01 02 03 04 05 06 + - + - Relay output 0 Alarm NO/NC (Param. 5-40.0) Relay output 1 Start Start Reference 0 10VDC (FW standard) Actual value PID regulation Run Indicator NO/NC (Param. 5-40.1) Analog switches A53 12 A54 12 ON ON ON = 0-20m OFF = 0-10VDC U V W PE 96 97 98 99 RS-485 com 61 RS-485 + 68 RS-485-69 The basic configuration (FläktGroup standard) relates to 0...10 VDC control via terminal block 53. M To activate the internal PID regulator see page 6. The sensor is connected to terminal block 54. SIGNALS Designation Type Terminal block Start Potential-free closure 12-18 Control signal 0...10VDC 53 Pressure/flow sensor 0...10VDC (4...20mA) 54 COM For analogue in (Terminal blocks 53, 54) 55 Alarm R1 NO/NC 01, 02, 03 Operation R2 NO/NC 04, 05, 06

6 Installation and maintenance BASIC CONFIGURATION FOR ASYNCHRONOUS MACHINES (FLÄKTGROUP STANDARD) When the frequency converter is energized for the first time the language can be selected. Obviously this can be changed later. After Smart Start is started for 0...10VDC control by pressing [ ], followed by pressing [OK]. Step Description TF FF 1 Language English English 2 Select Q3 Function Setups Asynchronous Asynchronous 3 Number of motors 1 1 4 Thermal motor protection ETR 1 ETR 1 5 Motor Power [kw] 6 Motor Voltage 7 Motor Current 8 Motor Frequency See motor plate 9 Motor Nominal Speed 10 Minimum Reference 0 Hz 0 Hz 11 Maximum Reference Hz Hz 12 Apply on terminal block 53 Yes Yes 13 Application Fan Fan 14 Autom Energy Optimisation Yes (2, 4-pon) Yes (2, 4-pin) No (other) No (other) See motor plate 15 AMA Yes Yes 16 Confirm AMA OK OK 17 Press [Main Menu] twice 18 Select 3-** Reference / Ramps 19 Select 3-4* Ramp 1 20 [3-41] Ramp 1, Ramp Up Time 21 [3-42] Ramp 1, Ramp Down Time 30s 40s When the frequency converter is energized for the first time the language can be selected. Obviously this can be changed later. After Smart Start is started for 0...10VDC control by pressing [ ], followed by pressing [OK]. When using CentriFlow 3D, you need to enter 1-06 and change the direction of rotation to [1] inverse. Configuration carried out by Date Smart Start can be reactivated at any time. First press [Quick Menus]. Then navigate using the [ ] and [ ] buttons until the cursor is on Q4 Smart Start. Then press [OK]. Danfoss factory reset Press [Main Menu] twice. Navigate using the [ ] [ ] and [OK] buttons until parameter 14 22 is displayed (select 14 **, then 14 2* and lastly 14 22). Set this parameter to [2] and then switch off the mains voltage. When the frequency converter is re-energised the parameters will have returned to their factory settings.

Installation and maintenance 7 ACTIVATING PID REGULATION Step Description TF FF 1 Press [Quick menus] 2 Press [Quick menus] 3 Select Q3-3 Closed Loop Settings 4 Select Q3-30 Single Zone Int.Setpoint 5 1-00 Confi guration Mode [3] Closed Loop [3] Closed Loop 6 20-12 Reference/Feedback Unit [72] Pa [72] Pa 7 20-13 Minimum Reference/Feedb. 0 Pa 0 Pa 8 20-14 Maximum Reference/Feedb. Pa Pa 9 Press [ ] once 10 6-24 Terminal 54 Low Ref./Feedb. 0 Pa 0 Pa 11 6-25 Terminal 54 High Ref./Feedb. Pa Pa 13 6-26 Terminal 54 Filter Time Const 1 s 1 s 14 Press [ ] four times 15 20-21 Setpoint 1 Pa Pa 16 20-81 PID Normal/Inverse Control [0] Normal [0] Normal See sensor See sensor Setpoint 17 Press [ ] twice 18 20-93 PID Start Speed 2.0 2.0 19 20-94 PID Proportional Gain 30.0s 30.0s Adjust if necessary 20 Press [Main Menu] twice 21 Select 0 ** Operation / Display 22 Select 0 2* LCP Display 23 0 20 Display Line 1.1 Small [1654] Feedback 1 [1654] Feedback 1 Configuration carried out by Date

8 Installation and maintenance MODBUS RTU IN EQ If Modbus RTU is used in eq AHU for controlling drives, they must be set according to the table below. Configuration Parameter Description Value 8-30 Protocol [2] Modbus RTU 8-31 Address Supply fan: 60 Exhaust fan: 70 8-32 Baudrate [2] 9600 8-33 Parity / Stop bits [2] No parity, 1 Stop bit PARALLEL OPERATION When two frequency converters are to operate in parallel, one must be configured as master and the other as slave. After this, connect the two frequency converters together as indicated below. Configuration, master Parameter Description TF FF 6-50 Function, terminal block 42 4-20mA 4-20mA Configuration, slave Parameter Description TF FF 6-14 Output frequency equivalent to 4mA 0 Hz 0 Hz 6-15 Output frequency equivalent to 20mA Hz Hz Set switch A53 (located under the display) to position I. The power to the converter must be switched off. Connection Master Slave 42 53 39 55