Single Phase Industrial UPS System Range: 10 to 300 kva series CEMENT POWER STEEL & METAL OIL & GAS
Single Phase Industrial UPS System Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of industrial UPS systems since 1987 and is an approved supplier with all the major consultants as well as to leading industries. The first UPS Company in the country to win ISO : 9001 certification, our manufacturing facilities are one of the finest in the country. A comprehensive support network that covers the entire country is always at your disposal. We offer the most appropriate technology and complete, customized, system-solutions for every demanding application for providing high quality back up power. i4 Series Parallel Redundant UPS System i4 series UPS systems are specifically designed to provide secure power to mission critical loads in Refineries, Petrochemicals, Power Generation, Steel and Process Industries as well as for critical data processing applications. These units adopt the most advanced technology available and comfortably surpass the specifications required in all grueling applications. Three phase input single phase output unit are available in rating from 10 kva - 300 kva and are custom built to your exact specifications. Block Diagram RECTIFIER CONTROL REDUDANT/SMPS GATE DRIVERS SYSTEM F/B & PS SYSTEM CONTROL SYSTEM MANAGER KEYPAD + LCD www.hitachi-hirel.com 02
Exceptional safeguard against power disruption Standard Features n Input reactors to minimize AC mains notching n Automatic Battery Charging Float / Boost mode selection with current limit n High efficiency : IGBT based inverter n Specially designed output transformer for PWM operation n Sinusoidal PWM operation with direct AC feedback handle nonlinear loads upto Crest Factor 3:1 with <5% THD n High branch fuse clearing capacity (upto 30% rated fuse) n DSP based control n Redundant control power supplies n Programmable static switch with upto ± 6% synchronization window n Comprehensive LED mimic and LCD + keypad enabled -Date Time stamped event recording last 999 events logged in non volatile memory - Programming & Monitoring of various system parameters IGBT modules in the inveter of an i4 Series UPS Also available with IGBT Based Active Front End Rectifier Input Power Factor Near Unity <5 % Input THDi Available Parallel Redundant, Cascade Redundant in, N+1 & Split Redundant configuration n RS232C interface and programmable potential free contacts n Front access oriented layout n PC based Monitoring, Control & Reporting unit (Optional) -Monitors the system performance with automatic generation of daily weekly reports. -Automatic service call fax generation with fault and alarm log details. -Higher level connectivity with DCS/PLC through MODBUS protocol. - Monitoring on LAN through SNMP - Battery Monitoring System. n A large array of options available including 12 pulse charger, IP53 protection, Parallel or Hot standby Redundancy, Redundant cooling fans and more System Control Board of an i4 Series UPS - The Microprocessor based digital control advantage! i4 Series Single Phase Industrial UPS Systems 03
Alarms, Indications and Metering LCD Display METERS - DIGITAL - LCD DISPLAY VOLTAGE & CURRENT METERS FREQUENCY METERS Mains Alternate Battery Inverter Load Alternate inverter TRIPS-TEXT READ OUT-LCD DISPLAY End of battery discharge IGBT limb 1 fault / IGBT limb 2 fault Over load (Inverse Time) Over temperature CPU fault Options Input Isolation Transformer 12 Pulse Rectifier Input Harmonics Filters Fan Redundancy Bypass Line Regulator AC Distribution Panels PC Based Monitoring & Recoding Unit RS - 485 Communication Port INPUT DC ALARMS-TEXT READOUT -LCD DISPLAY BATTERY INVERTER ALTERNATE STATIC SW Under Voltage Over Voltage Over Voltage Discharging Under Voltage Under Voltage Over Volta ge Over load Disconnected Under Voltage Over Voltage frequency out of limit Transfer t o alternate Note: All Alarms and trips initiate an audible warning Monitoring on LAN through SNMP Battery Monitoring System Remote Annunciator Automatic Server Shutdown Kit DCS Connectivity through MODBUS / POFIBUS Protocol 110 VDC * / 220 VDC ** / 490 VDC Bus Voltage 0 50 C Ambient in IP 41 Enclosure Bypass line equipment SCVS-SSVS-CVCF * Up to 20 kva and ** Up to 150 kva www.hitachi-hirel.com 04
Technical Specifications State-of-the-art IGBT driver for higher reliability MAINS INPUT Voltage Frequency DC BUS Voltage Maximum DC Bus Ripple Without Battery Max DC Bus Ripple (with Battery) OUTPUT Nominal Voltage (1 Phase) Load Power Factor - Rated Load Power Factor - Range Voltage Regulation Steady State 100% Step Load Recovery Time to 98% Over Load 110% 125% 150% Branch Fuse Clearing Ability Frequency Bypass Synchronization Window Internal Oscillator Slew Rate Total Harmonic Distortion Linear Load Nonlinear Load (CF 3:1) OPERATING CONDITIONS Ambient Temperature Altitude Humidity Atmosphere Audible Noise @ 1metre from Panel Front ENCLOSURES Construction Protection Class Finish (Powder Coated) Ventilation Cable Entry 415 V +15% -25% Three phase Three wire 50 Hz ± 10% 304 to 434 V 2% RMS 1% RMS 220/230/240 V 110/115/120 V 0.8 0.6 to Unity ± 1% ± 5% typical < 20 ms 3600 Seconds 900 Seconds 60 seconds 30% Rated (Semiconductor Type Fuse) 50 Hz ± 1% to 6 % (Field Programmable) ± 0.1% 1 Hz/Sec <2.5% <5% 0 0 45 C (50 C Optional) Meter From MSL 95% Non Condensing Non Corosive, Dust Free, Freely Ventilated 55 dba to 74 dba (depending on system rating system Configuration) CRCA Steel Sheet (IP 41 (IP 42, IP 43, IP 52 & IP 53 Optional) RAL 7032 (Other Colours Optional) Forced Air (Internal Fans) Bottom (Top Optional) Note: Overall audible noise, heat generation etc. depend upon the system configuration and options required. i4 Series Single Phase Industrial UPS Systems 05
Dimensions Rating (kva) Height (mm) Width (mm) Depth (mm) Weight (Kg) 10 20 25 30 40 50 60 75 100 120 130 150 180 200 225 250 300 1400+100 1400+100 1400+100 1800+100 1600+100 1700+100 1700+100 1700+100 800 + + + 1200+1200 1200+1200 1200+1200 1200+1200 1200+1400 1200+1400 1200+1400 800 800 900 900 900 Dimensions on request 300 300 350 500 700 850 950 1150 1550 1650 1650 2000 2500 2500 2750 Note: Height of canopy and top fan box not included in the height dimension indicated above. Dimensions & weights indicated are approximate. Dimensions and weights are subject to change based on configurations and options selected. Dimensions for i410 kva to 30 kva UPS systems are without I/P x'mer. Serving Entire Gamut of Industries We have rich experience in supplying power electronics products & complete customized solutions for mission critical applications in refineries, petro-chemicals, power generation, steel & metal and process industries as well as critical data processing applications and back-up technology and complete customized system solutions for demanding applications.. and others... Power Oil & Gas Steel & Metal Cement Chemical Pharmaceutical Plastic Pulp & Paper Packaging Textile and many more... www.hitachi-hirel.com 06
About Us Founded & established in 1983 as Hi-Rel Electronics Pvt. Ltd., we are now a Hitachi group company - Hitachi Hi-Rel Power Electronics Pvt. Ltd., recognized as a pioneer in power electronics. With 3 decades of experience, we have garnered a significant level of trust in our market segment and continue to offer world class power electronics products, value added services & customized solutions. Our product portfolio includes UPS (uninterruptible power supply) for industrial, commercial & enterprise applications, medium voltage & low voltage variable frequency drives, steel automation & engineered drives for customized applications, industrial automation & control products like PLC, SCADA & DCS, solar inverters, railway products and other customized products like UMPS, I-dip (dip ride through solutions). Leading manufacturer of UPS, drives & automation products and solar inverters State-of-the-art manufacturing facility at Gandhinagar & Sanand in Gujarat, India In-house R&D facility recognized by DSIR, Government of India ISO 9001:2008, ISO 14001:2004 & BS OHSAS 18001:2007 certified company with export house status Approved by leading consultants and EPC vendors Pan India & global presence Serving entire gamut of industries Rich experience in mission critical applications Dedicated & decentralized 24x7 after-sales-service Offers products with greater energy efficiency & lower carbon footprint With expertise, experience and an efficient product line, we will always be your power electronics partner. When you choose to do business with us, you are partnering with a company who cares. i4 Series Single Phase Industrial UPS Systems 07
Global & Pan India Presence USA Middle East Japan India South East Asia Africa Australia Jammu & Kashmir Jammu Amritsar Ludhiana Chandigarh Mandi Himachal Pradesh Punjab Jaipur Jodhpur Barmer Kanpur Gwalior Ajmer Udaipur Gandhinagar Ahmedabad Mehsana Sanand Mundra Jamnagar Rajkot Baroda Ankleshwar Surat Vapi Haryana Hisar Noida Uttara khand Lucknow Indore Bhopal Uttar Pradesh Rajasthan Maharashtra Nagpur Belgaum Siliguri Guwahati Gorakhpur Allahabad Muzzafarpur Gopalganj Arunachal Pradesh Ranchi Jorhat Sibsagar Meghalaya Bihar Sasan Korba Jharkhand Bokaro West Bengal Kolkata Jamshedpur Jajpur Angul Chattisgarh Bilaspur Cuttak Orisaa Bhubaneswar Raipur Bhilai Madhya Pradesh Gujarat Nashik Mumbai Pune Dehradun Moradabad Patna Agartala Hyderabad Vizag Rajahmundry Andhra Pradesh Bellary Karnataka Kadapa Udipi Bangaluru Chennai Manufacturing Plant Mangalore Tamil Nadu Kerala Tiruneveli Corporate Office Branch Office Thiruvananthapuram Service Center Hitachi Hi-Rel Power Electronics Pvt. Ltd. B - 14/1 & 171, GIDC Electronics Zone, Sector - 25, Gandhinagar - 382 044, Gujarat, India. Phone: +91-79-2328 7180/81, +91-79-6170 0500, Fax: +91-79-2328 7182 Email: contact@hitachi-hirel.com, Web: www.hitachi-hirel.com In the spirit of continuous improvement, specifications are subject to change without notice. i4 / 02 / 15 / Ver.1 / Corp. Mktg. / India l Spotlight - 079 3002 2324 Coimbatore Karaikal Palakkad