TFS 2100 Traveling Wave Fault Location System

Similar documents
TFS-2100E Travelling Wave Fault Locator System Description and Specification

TWFL - Travelling Wave Fault Location System

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

DRTS 33. The new generation of advanced three phase relay test set

CBA HV Circuit Breaker Analyzer and Microhmmeter

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS.

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

CBA 1000 Circuit Breaker Analyzer and MicroOhmmeter

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

IDM DATA ACQUISITION SYSTEM

A P P L I C A T I O N

THE INTEGRATED TESTING SOLUTION

CBA 1000 CHARACTERISTICS

Bus Bar Protection Relay B-PRO 4000

DRTS 66 can test all the following relays

SM100. On-Line Switchgear Condition Monitoring

Feeder/ Motor Protection Relay VAMP 40

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany

Residual overvoltage relay

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Scout-S Station Controller

A2000 Multifunctional Power Meter

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information

MINER-S Station Controller

GRID/PRSHT/MU320/EN/1.2014/GBR/1894 ALSTOM All rights reserved.

Earth-fault Relay SPAJ 110 C. Product Guide

G4K Fixed Power Quality Analyzer BLACKBOX. Don t be left in the dark

XU1-E Earth fault voltage relay. (August 1996) Manual XU1-E (Revision New)

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

MINER-S Station Controller. Substation Automation

6220 Ethernet-Based Voltage Measurement Module

MIC-2 Multi-instrument DATA SHEET

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

MIC-2 MKII, Multi-instrument DATA SHEET

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

LPI SST Surge Filters

Control and Protection System Win-TDC

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Substation Automation Products. Line differential protection RED670 Relion 670 series

FL MC 2000E (SM40) LC

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Discover. BlackBox G4400. Outstanding Features. Designed for Your Needs. PQZIP Compression Technology. Elspec s Unique Technology

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

CompuScope Ultra-fast waveform digitizer card for PCI bus. APPLICATIONS. We offer the widest range of

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Circuit Breaker Sentinel (CBS) for SF 6. power circuit breakers

Technical Data Sheet Medium Current Power Surge Filters

Sub-Station Station. Secondary Sub. Sub- Distribution. Network. Distribution Panel. Distribution. Panel

Feeder protection relay SPAA 121 C. Product Guide

DIN Rail RTU 540CMD01 Data sheet

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

InHand Wireless. As an important sector of smart grid building, smart distribution network faces the

Deploying Digital Substations: Experience with a Digital Substation Pilot in North America. Harsh Vardhan, R Ramlachan GE Grid Solutions, USA

Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers

SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics

TM241C40U controller M IO transistor NPN

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

An expert solution is within your reach. EORSys. We take care of it.

General Specifications

A variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation

TM241C24T controller M IO transistor PNP

Communication Gateway COM 610. Product Guide

Automation System Solutions

Modular Two-Wire Telecontrol System

PMC 530 Series Advanced Multifunction Meter

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

TM241CE24T controller M IO transistor PNP Ethernet

Q Series - Q.station 101 Test Controller

TM241CE24U controller M IO transistor NPN Ethernet

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

Power Transmission and Distribution. I m on guard here! SIMEAS R reports power system weaknesses quickly and accurately

M-Bus Central Unit. Use

Transformer Protection Relay

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Circuit Breaker Analyzer & Timer CAT66

Synchro-check relay. Application

Est Constant Current Regulator MC2 3kW 30kW

LPI SG + SST Spark Gap Surge Filter

Circuit Breaker Analyzer & Timer CAT65

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

TM221M16R controller M IO relay

InteliPro. Protection Relay for Parallel Applications. Technical Specification

PMC-630 Series Advanced Multifunction Meter

TM241CE24T controller M IO transistor PNP Ethernet

Circuit Breaker Analyzer & Timer CAT126

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

ADVANCED TEST AND DIAGNOSTIC SYSTEMS.

Circuit Breaker Analyzer & Timer CAT126

TM221M16TG controller M IO transistor PNP spring

Transcription:

Traveling Wave Fault Location System The most accurate overhead transmission and distribution line fault locator Accuracy: ±150m typical regardless the line length Unaffected by fault resistance Suitable for all kind of power lines AC and DC Automatic distance to fault calculation Unlimited number of monitored lines Reduce overhead lines outage time Non intrusive installation Easy to set up Master Station software for distance to fault calculation and analysis Ethernet TCP/IP, Modem and Point to Point connections available OVERVIEW The Traveling Wave Fault Location System TFS 2100 provides accurate fault location solution for transmission and distribution power lines. The fault distance measurement error is less than ±150m typical regardless of the line length and free from the influence of factors which affect fault location accuracy using traditional impedance methods. The traveling wave technique can also be used to locate the single phase to ground fault in distribution systems with nonsolidly earthed neutral, which can not be accomplished by any other techniques so far. The traveling waves based fault location was first proposed in the 1930s and was made practical for field application in 1990s with the availibility of microelectronic-based ultra-high speed data acquisition and time synchronization using (Global Positioning System) receivers. While the traveling wave fault locator developed in 1950s measures transient voltages using a specially designed capacitor coupler attached to high voltage bus, the modern system measures the transient signals of existing current transformer (CT) secondaries. This makes the system installation very easy and cost effective. Fault Location Principle Traveling waves are voltage and current surges propagating along the power line, arising from power system disturbances such as fault, switching operations and lightning. The traveling wave fault locator determines distance to fault by measuring the time for a surge to travel from fault position to measurement point. Since the 1950 s several practical fault location methods have been proposed. - Traveling wave data acquisition unit 1

Type D (Double Ended) Method XS XR L S F R Type D method time tags the arrival of the fault generated surges at two time-synchronized locations, usually the ends of the line. The fault distance is determined in terms of the difference of the arrival times. X S = [(T S - T R ) n + L]/2 X R = [(T R - T S ) n + L]/2 T S and T R are the arrival times of fault generated surges at the two terminals of the line; n is velocity of traveling wave, which is closer to light velocity in overhead line. L is total length of the line. Type A (Single ended) Method Type A method determines fault distance by analyzing the fault generated traveling wave waveforms recorded at one end of the line. The time difference Dt between the initial fault surge and the corresponding reflected pulse from fault is the time interval for a surge to travel from terminal to fault and back. It can be used to calculate distance to fault XL. S t TS1 TS2 TS3 Initial surge F Fault reflection X L = Dt n/2 Type E Method Type E method makes use of transients generated when a circuit breaker is closed to a dead line. The time interval between the pulse created by breaker closing and the reflected pulse from a short circuit, open circuit or broken conductor is used to calculate the distance to fault. R Application of different methods The Type D method is simpler and proven to be excellent in accuracy and reliability by field operation results. The Type E method is very efficient to locate broken conductor faults. The Type A method is more cost effective, but its reliability is compromised by the difficulty in discriminating fault reflections from pulses introduced by reflections from other line terminals and nonlinearity of fault arc. TFS 2100 uses the Type D method as its major fault location principle, while the Type A and Type E methods are employed as complimentary fault location means. Measuring traveling waves The traveling waves can be detected by monitoring the fault generated transient voltage or current signals at the bus. For AC Power Line The conventional current transformer (CT) which can reproduce current transients faithfully in secondary qualities provides a simple and cost-effective means to detect traveling waves for AC power lines. For maximum ease of installation an auxiliary clip on CT could be used to measure the transient current of existing CT secondary. The bus of the AC power line has usually more than one line connected besides the faulted line and therefore produces very significant current transient when the incident surge arrives, which ensures the detection sensitivity of the traveling wave. If there are no other lines other than the faulted line connected to the bus the magnitude of transient current is limited and the voltage transient should be measured using conventional voltage transformer (VT). In EHV transmission system with capacitive voltage transformer (CTV - which is a tuned circuit and has filtered out transient responses) installed, the transient voltage can be acquired indirectly by measuring transient current through the earth wire of the coupling capacitor using a clip-on transformer. 2

TRAVELING WAVE FAULT LOCATION SYSTEM T2000 TRANSFORMER TEST SET V Harmonic filter DC Trasmission Line C1 i C2 TV For HVDC Transmission Line The CT s and VT s of HVDC system are usually installed behind harmonic filtering circuit and their outputs can not be used to detect traveling waves from the line. The transient voltage can be acquired by measuring transient current through the earth wire of the surge suppression or carrier coupling capacitor using a clip-on transformer. SYSTEM DESCRIPTION The TFS 2100 consists of Traveling Wave Data Acquisition Unit TDU 100 installed at substations, a Master Station Software deployed in the control center and communication network. Each can monitor up to 4 lines, and therefore two or more units are needed to monitor more than 4 lines in a substation. In bay level application a is dedicated for one line monitoring and installed near the circuit breaker. When more than one is installed in a substation, a Data Processing Server DPS 100 is used to collect traveling wave data acquisition units and communicates with the Master Station. Master station TAS 2100 Communication network Up to 4 lines More than 4 lines Travelling wave data acquisition unit Data processing server DPS 100 System Configuration 3

TRAVELING WAVE DATA ACQUISITION UNIT AND T 2000 records traveling wave transients and it is synchronized by an external clock (T 2000). It continuously samples the secondary outputs of CT s or VT s and stores the sampled data in a circular memory buffer. The buffered data is then transferred to a non-volatile memory when the unit is triggered, i.e. the deviation of any input signals exceeds a pre-set threshold level. The acquired transient data are then sent to the Master Station via communication network for further processing. - Traveling wave data acquisition unit The features:. Number of inputs: 3-12 input channels configurable for 1-4 lines, 1-10ms length of record time and 100 khz - 4 MHz sampling frequency, user programmable.. Software controlled analog gain and trigger threshold.. Direct CT secondary input or via an external clip-on CT.. Synchronized to 1 µs accuracy by external clock ( MC 100).. 1Mb standard or optional 12 Mb nonvolatile memory for local transients data storage.. Successive transient recording with less than 100 µs reset time.. Contacts inputs and outputs are provided for external triggering, remote alarm and indication of internal failure, such as lost of synchronization.. Support local setting and transient records interrogation through Ethernet port.. 1 RS 232/422 port, 2 RS 232 port and 1 Ethernet port enable flexible communication, including point-to-point, dial-up or TCP/IP communication to the Master Station using selectable protocol and point-to-point or TCP/IP communication to the Data Processing Server (DPS 100). MASTER STATION The Master Station is a PC and runs Traveling Wave Analysis Software TAS 2100 (Windows NT/2000/XP/Vista environment). It collects and processes the transient data acquired by each traveling wave data acquisition unit and calculates the distance to fault automatically by the double-ended (Type D) method. The Master Station with TAS 2100 software features:. Automatic distance to fault calculation based on Type D Method.. Versatile waveform analysis utilities to allow the users to analyze the fault waveforms in detail and measure the distance to fault by identifying fault reflections.. Transient records management to allow the user manipulate, search, copy in and copy out the fault waveforms.. Support remote configuration and setting to the field.. Remote diagnosis to allow the service engineer of system provider to maintain the system or verify the fault location results.. Support point-to-point, dial-up or TCP/IP communication to the or DPS 100 units. A serial communication server connected to the Master Station through a Ethernet port is used to extend multiple point to point ports. T 2000 - Syncronization clock 4

TRAVELING WAVE FAULT LOCATION SYSTEM T2000 TRANSFORMER TEST SET DATA PROCESSING SERVER DPS 100 DPS 100 is used to collect the data of units and communicates to the master station when two or more TDU 100 units are installed in a substation. Its 6 RS 232/485 ports and 2 Ethernet ports support point-to point, dial-up or TCP/IP communication to the Master Station and serial point to point or Ethernet connection to the. With a built in Flashdisk the DPS 100 can store a large amount of collected transient records. DPS 100 - Data processing server Dial up modem The /DPS 100 and the Master Station are connected to the utility or public telephone network using modems connected to their RS 232 port. COMMUNICATION The transient data acquired by each are sent to the Master Station by dialing up modem communication automatically from the TDU to Master Station. Master station TAS 2100 Modem Telephone network Up to 4 lines Modem More than 4 lines DPS 100 Modem communication configuration 5

The /DPS 100 and the Master Station are linked together through a dedicated point to point data transmission channel provided by optical fiber or microwave communication network. Communication is via RS 232 port. POINT TO POINT CONNECTION The baud rate is 1,200-56k bps selectable depending on channel conditions. A serial communication server is used to extend multiple point-to-point connections of Master Station to field traveling wave data acquisition units. Master station TAS 2100 N-Port Server Up to 4 lines Point to point Channels More than 4 lines DPS 100 Point to point connection configuration TCP / IP NETWORK The, DPS 100 and the Master Station are connected to a TCP/IP network via their Ethernet ports. Master station TAS 2100 TCP/IP network Up to 4 lines More than 4 lines DPS 100 TCP/IP network configuration 6

Advanced Protection Relay Test Set and Measurement System TFS 2100 TRAVELING WAVE FAULT LOCATION SYSTEM SPECIFICATIONS Traveling Wave Data Acquisition Unit Input:. Channels: 3-12 configurable for 1-4 lines application.. Type of input: Secondaries TA, TV or Clip on TA depending on field application A/D conversion:. Sampling rate: 100 khz-4mhz programmable, standard 1MHz.. Resolution: 12 Bits Length of each transient record:. 1-10ms programmable, standard 4ms. Nonvolatile memory:. 1Mbytes Contact input:. 1 dry contacts, 1 for optional control Alarm:. 2 dry contacts: normally open.. Contact rating: 28V DC/2A, 250V AC/0.5A. 1 for power failure alarming, 1 for synchronization lost Communication port:. 2 RS 232 port. 1 Ethernet port Time synchronization:. 1PPS synchronization signal, RS 232/422 for date information input. IRIG-B Power:. Voltage 90...240V, 50Hz AC or 90...240V DC. Power consumption: <10W Environment:. Operating temperature: 0-55. Storage temperature: -40-85. Humidity: 5% - 95% (non-condensing) Applicable standard: IEC 255-22-1(1988); EC 255-5(1977) Electromagnetic Compatibility: EN61326 Low Voltage Directive: EN61010 Physical dimension: 19, 2U Traveling Wave Analysis Software TAS 2100 Minimum hardware requirements:. X86 series Pentium II 366 above desktops or laptops Software environment:. Windows 95/98 / NT 4.0 / 2000 Professional / XP / Vista Communication port:. 2 RS 232 port. 1 Ethernet port. RS 232 port Extension for multiple point to point communication to TDU s, Serial port server Data Processing Server DPS 100 Master station Communication:. 1 RS 232 port. 1 Ethernet port TDU communication. 4 RS 232 ports Mass storage memory 4 Gbytes. Power:. Voltage: 90...240V, 50Hz AC or 90...240V DC. Power consumption: <10W Environment:. Operating temperature: 0-55. Storage temperature: -40-85. Humidity: 5% - 95% (non-condensing) Applicable standard: IEC 255-22-1(1988); IEC 255-5(1977) Physical dimension: 19, 2U T 2000 syncronization clock Indications:.Power.1PPS. Sync. Lost Performance acquisition time:. 90 seconds max typical (new installation).. 90 seconds max with location changes.. 45 seconds max without location changes.. 20 seconds max with power instant shut up. Time accuracy:.1 µs for PPS Output port features:. Voltage between dry contact C and E VCE<30V.. Current between dry contact C and E ICE< 50mA. Serial Port Outputs with selectable baud rate:. 2 RS 232 outputs.. 2 RS 422/485 outputs.. 1 IRIG-B Programmable Pulse Output:. PPS, PPM and PPH output, standard 200 ms pulse width.. 7 dry contact outputs.. 1 TTL wet contact output. 7

Power:. Voltage 110V, 50/60 Hz AC, 110 V DC 220V, 50/60 Hz AC, 220V DC. Power consumption: <10 W Environment:. Operating temperature: 0-40. Storage temperature: -40-50. Humidity: 5% - 95% (non-condensing) Applicable standard: IEC 255-22-1(1988), IEC 255-5(1977) Electromagnetic Compatibility: EN61326 Low voltage directive: EN61010 Physical dimension: 19, 2U Weight: <3 kg EXAMPLE OF FAULT LOCATION RESULTS ORDERING INFORMATION: CODE MODULE 10171 Traveling Wave Fault Location System TFS 2100, including: - No. 1 data acquisition unit (for 1 power line), 2 RS 232, 1 Ethernet port, 1 IRIG-B, 1 Mb non volatile Memory - Master Station Software license TAS 2100 (code ZSW90171) 11171 Traveling Wave Fault Location System TFS 2100, including: - No. 1 data acquisition unit (for 2 power lines), 2 RS 232, 1 Ethernet port, 1 IRIG-B, 1 Mb non volatile Memory - Master Station Software license TAS 2100 (code ZSW90171) 12171 Traveling Wave Fault Location System TFS 2100, including: - No. 1 data acquisition unit (for 3 power lines), 2 RS 232, 1 Ethernet port, 1 IRIG-B 1, Mb non volatile Memory - Master Station Software license TAS 2100 (code ZSW90171) 13171 Traveling Wave Fault Location System TFS 2100, including: - No. 1 data acquisition unit (for 4 power lines), 2 RS 232, 1 Ethernet port, 1 IRIG-B, 1 Mb non volatile Memory - Master Station Software license TAS 2100 (code ZSW90171) 11150 Additional 1 Power Line (up to 3 additional lines) 20171 DPS 100 - Data processing server: Mass Storage memory 4 Gbytes, 4 RS 232 ports, 1 Ethernet port. 13150 12 Mb Flash Memory expansion option for 14150 Clip-on CT (1 Power Line) - q.ty 3 CT s 30171 T 4000 receiver - 2 RS 232, 1 IRIG-B, 2 RS 422/485 for centralized installation 31171 T 2000 receiver - 1 RS 232, 1 RS 422/485, 1 IRIG-B for distributed installation 17150 antenna with 30 m cable 18150 antenna with 40 m cable 19150 antenna with 50 m cable The document is subject to change without notice. 8 ISA Srl Via Prati Bassi, 22 21020 Taino VA - Italia Tel +39 0331 956081 Fax +39 0331 957091 Web site: www.isatest.com E-Mail: isa@isatest.com GB -TFS 2100-04-09