HANDBOOK OF CABLE TESTING

Similar documents
Testing and Measurement Technology. Handbook of Cable Testing. Fault Analysis Documentation and Reporting. h ps://itnetworks.softing.

Testing Network Infrastructure

A FLUKE networks DTX 1800 Cable Analyzer és DTX Fiber Modules

Wire pert. Cable Certifier. 1st CAT. e C. Cable Tester of Choice

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation

Ethernet Cable Testing, Certifying & Diagnostics Jim Ralston Director of Sales

Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks

Complimentary Reference Material

White Paper: Choosing the RIght OTDR for your Datacenter

Zarządzanie sieciami telekomunikacyjnymi

Cabling Infrastructure

History of Standards

Datasheet: DSX CableAnalyzer Series

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

PRODUCT CATALOG. Certification, qualification, verification & troubleshooting of network infrastructure from copper up to 2,500MHz to fiber.

Network Media and Layer 1 Functionality

Series. WireXpert Key Features. Easy to use and Ruggedized design. Fast and simple for highest productivity

Chapter 3 Certifying Twisted Pair Cabling

Softing PROFINET Diagnostic Tools

Psiber Data WireXpert P R O F E S S I O N A L N E T W O R K T E S T I N G & P R O T O C O L A N A L Y S I S

The AMP NETCONNECT Category 6 Cabling System

The AMP NETCONNECT Category 6 Cabling System

SECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

User Manual Fiber Certification Testing

EoC MDU Wi-Fi Voice Endpoint User s Guide

Chapter 4: Network Access. Introduction to Networks v5.1

Common Mistakes Made in Certification Specifications and Testing. Jim Davis Regional Marketing Engineer Fluke Networks

Testing Considerations for Beyond 10Gigabit Ethernet. Erin Hallett

A+ Guide to Managing & Maintaining Your PC, 8th Edition. Chapter 16 Networking Types, Devices, and Cabling

Multimode Measurement Cords Recommendations for Multimode Link Field Certification

Advances in Fiber Tier 2 Enterprise & Data Center Testing

ELEC / COMP 177 Fall Some slides from Kurose and Ross, Computer Networking, 5 th Edition

Deviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved.

ISO/IEC 11801: (E)

Mosaic TM LCS2 Cat. 6 RJ 45 socket

Ethernet 101 Siemens Industry Inc All rights reserved. usa.siemens.com/industry

New standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks

Datasheet: CableIQ Qualification Tester - The network tech s vision into cabling bandwidth.

Mosaic TM LCS2 Cat. 6 RJ 45 socket

MORE ETHERNET ON THE HORIZON WHO NEEDS 2.5G AND 5G ETHERNET? Krzysztof Ojdana, Product Manager WHITE PAPER. Molex Connected Enterprise Solutions

The Impact of Internet of Things on Cable Certification

White Paper: Installing Data Networks Using LinkWare Live SaaS

The Impact of Internet of Things (IoT) on Cable Certification

REPORT INTERTEK TESTING SERVICES, INC.

ANSI/TIA-568-C Cat 6A Field Test Specifications

Certification for 10G copper cabling

THE INTERCONNECTED NETWORK

The data transmission mode describes the direction of data flow. It is either simplex, half duplex or full duplex.

White Paper: Testing Strategies for SYSTIMAX High Speed Migration Solutions

with its cables, connectors, Switches, Hubs and topologies

Addressing issues in the local area network

The High Cost of a Low-Cost Cable Certification Tester

CHAPTER 7 Copper Cable Testing

Qualified Partner Programme QPP. Warranty Felice Guarna

Frequently Asked Questions (FAQs) Siemon 10G ip Solutions

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

Review For Exam 2. Internetworking. Summary Questions. School of Business Eastern Illinois University. School of Business Eastern Illinois University

ANSI/TIA-568-C Cat 6 Field Test Specifications

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment F Cable Certification

Performance specification for the Fluke DSP Fluke Corporation

Chapter 10: Local Area Networks

Datasheet: DSX CableAnalyzer Series

Multi-Service Cabling in Customer Premises

Wire pert. 1st CAT8 Cable Certifier. Ethernet CABLE CERTIFIER

Part3. Local Area Networks (LAN)

Open System Architecture Selecting the Right Cable and Connectivity for Your Application

History Channel. 10G Ethernet on Copper

Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope

COMPUTER SKILLS COMP101

[0.057] 5.8 [0.23]

Physical Layer Part 3

How to successfully set up your service.

Datasheet: DSX CableAnalyzer Series

Passive optical LAN explained

LAN. CS 4/55231 Internet Engineering. Kent State University Dept. of Computer Science

Review For Exam 2. Fundamentals of Data & Signals. Summary Questions. School of Business Eastern Illinois University

Network+ Guide to Networks, Seventh Edition Chapter 5, Solutions

Evolving Telecommunications to Triple Play:

Application Note. Data Center Standards and Layouts

Chapter 8 Networking and Digital Communication

Course Outline 11/6/ Santa Teresa Blvd Gilroy, CA COURSE: CSIS 274 DIVISION: 50 ALSO LISTED AS: SHORT TITLE: TELECOM/NETWK CABLE

Physical Layer Part 3

Net pert. Cable Qualifier GIGABIT LAN QUALIFIER WITH NETWORK DIAGNOSTIC TOOL

Computer Networks and Internet

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India

Introduction to LAN Topologies Cabling. 2000, Cisco Systems, Inc. 3-1

The NIC is the main interface between the computer and the network cable.

Cabling to support ac and beyond. Nate Herring Sr. Product Manager Hubbell Premise Wiring

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

SignalTEK II. idealindustries.com

Your network s path to its fiber future. Grow confidently with fiber solutions from an experienced partner

Telegärtner Point of View

ScopeData Pro User s Guide

LANmark-7A H i g H - S p e e d C O p p e R S O l u t i O n F O R 4 0 g i g a b i t a p p l i C a t i O n S

TIA TR-42 Liaison to IEEE

Pro 21/Galea/Sistena socket for LCS 6 Category 6

White paper. Field Testing of Direct Attach Modified Permanent Links. occfiber.com

WireScope 155 SCOPE. Agilent Wirescope 155 Specs Provided by The Performance Leader in Hand-Held Network Tools

[0.057] 5.8 [0.23]

Transcription:

Testing and Measurement Technology Fault Analysis Documentation and Reporting HANDBOOK OF CABLE TESTING

Wire pert Cable Certifier WX4500 Best-in-Class Certifier for today and tomorrow. CAT 8 Ready! CAT8 CAT7A CAT6A CAT6 CAT 5e FIBER TESTING MPO PATCH CORD COAX M12 n Full graphical view and control from both local/remote units n Easy field operation with intuitive touch screen and 2 USB ports n Fast Autotest for CAT 6A n First tester to support MPO/MTP testing n Encircled Flux (EF) compliant for Multi-Mode fiber optic testing n Approved by all major cable manufacturers worldwide info@psiber-data.com www.psiberdata.com

Editorial On the way to new frontiers High-quality copper wiring in local area networks form the basis for fast and secure data communication. In the 90th users were satisfied with transfer rates of 10 & 100 Mbit/s, which is no longer enough today. Today we are talking in LANs about 1 & 10 Gbit/s and - especially in the environment of data centers - about 40 Gbit/s over copper cabling. The latest technologies in multimedia environments, such as Next-Generation Wireless LAN (IEEE 802.11ac) and HDTV with high resolutions (4K and 8K), drive the bandwidth - and therefore the transfer speeds - in copper data networks up into new heights. To ensure the warranties and the proper function of these high-speed copper data networks, this inevitably includes measurement and testing of these cabling systems. So the field testing technology must be prepared. Meanwhile, we are talking about Cat 8 / 8.1 / 8.2 and Class I & II. So we are dealing in this brochure with these issues as well. We continue the tradition of summarizing all issues around measuring- and testingtechnology of copper data network cabling in a handy booklet. The first issue on this subject appeared already in March 2007. This new edition of The Handbook of Cable Testing will easily find its place in the tool box or in the case of the measuring equipment of every data cabling installer: Always at hand, quickly to look up, with comprehensive information and up to date. We wish you smooth installations and testing of data cabling installations. Sincerely Dipl.-Ing.(FH) Thomas Huesch Technical Support & Training Psiber Data a Softing Company 3

Content Table of Contents 5 Chapter 1: Retrospective, History 5 Evolution of Ethernet 6 Increasing Data Rates 7 Chapter 2: Structured Cabling 7 Cabling Standards 7 Structured Cabling 9 Categories and Classes 12 Complex Relationships in Standardization 12 It all began in the USA 13 Standards Applicable at the International / European Level 14 What do the tables show by comparison? 14 Augmented Connectors 15 Increasing Cable Requirements 16 Consideration of other Transmission Parameters 19 Chapter 3: Measurement Technoloy 19 Measurement Technoloy for Copper Cabling New Challenges 19 Definition of Permanent Link and Channel 21 Is the Wiring (Wiremap) Correct? 22 Direct Current Resistance of Pairs 23 Propagation Delay and Delay Skew 23 Determination of Cable Length 24 Measurement of the Ultra-High (RF) Frequency Properties 25 Attenuation of Pairs 25 Crosstalk of Pairs at the Near End (NEXT) 26 Return Loss of Pairs 27 Crosstalk of Pairs at the Far End (FEXT) 28 Attenuation-to-Crosstalk Ratio Near End (ACR-N) 29 Attenuation-to-Crosstalk Ratio Far End (ACR-F) 30 Power Sum 31 Chapter 4: Documentation / Reporting 31 Documentation of Test Results 33 Chapter 5: Fault Analysis 33 Fault Analysis in Data Networks 33 Wiring Faults, Incorrect Connector Termination 34 DC Resistance Faults 34 Delay Skew between Pairs 34 High Attenuation, Weak Signal? 35 Crosstalk in Data Cables 36 Return Loss Faults 37 ACR Faults 37 PSNEXT (Power Sum NEXT) faults 38 Quality will Decide 40 Chapter 6: Patch Cords 40 Measurement Equipment for Patch Cords 40 What is a Patch Cord? 41 How to Test Patch Cords? 43 Measurement Equipment for M12 Cabling 44 Perspective 44 Smartphones / BYOD 44 Television / Multimedia 45 Automation Technology 45 Wireless Networks 45 Cloud Applications 4

Booklet of Cable Testing Data Transmission Technology: Standards Installation Measurement Fundamentals of Network Technology This brochure takes a closer look at data transmission technology starting with the evolution of networks, standards, certification testing and troubleshooting to reporting and documentation. Did you know that the popular and widely used Ethernet celebrated its 40th anniversary and that IEEE 802 began the standardization of Ethernet as early as 30 years ago with the first 802.3T standard? The use of computers, smart TVs, telephone systems using VoIP technology and building communications systems (door communications systems, alarm systems) has become an integral part of our modern life. But it is not long ago that separate communication networks were needed to run them: Twisted cables for the telephone, coaxial cables for the television and clumsy data cables (IBM) for the early office PC systems. Today, however,»ethernet«has established itself as the dominant standard in communications technology and is equally used by the various disciplines. Nowadays, the term»ethernet«describes both, the physical interface (cable, connector) and the transfer protocol, providing the basis for the universally known»tcp/ip«world the logical functions of the network components. This brochure will focus on the physical Ethernet interface that is well known as»structured building cabling«. If you are a skilled measurement technician you will even have to consider it when it comes down to its planning, installation, certification testing and operation. For a better understanding, let us start with the basics of today s network infrastructure. Everybody is talking about the so-called»universal structured building cabling«. What does this mean and which relevant standards do exist? Chapter 1: Retrospective, History Evolution of Ethernet Let me quote Bob Metcalfe (Figure 1), the inventor of Ethernet, who is now a professor of Innovation at the University of Texas in Austin, for some historical data. He commented the happy event in 2013:»On May 22nd, we celebrated the 40th anniversary of the invention of Ethernet at Xerox PARC. Now, on June 23rd, we celebrate the 30th anniversary of Ethernet s standardization by IEEE 802.«Of course, Ethernet has been standardized many times by IEEE 802.3 since 1983 to incorporate the rapid innovations from 2.94 Mbit/s to 100 Gbit/s, from thick to thin coaxial cables to twisted-pair and to optical fiber cables and Wi-Fi, from CSMA/CD bus networks to switches and ultimately wireless access points whilst assuring a high degree of backward compatibility.» By 1983, 5

Booklet of Cable Testing there were people buying Ethernet whom I did not know personally. By 1985, there were people whom I did not know inventing Ethernet. And they continue doing so today with great success Figure 1: Ethernet inventor Bob Metcalfe is today professor for innovation at the University of Texas in Austin using the open standardization processes of IEEE. Congratulations, and thank you«, Metcalfe continued (Source: IEEE SA). Increasing Data Rates The same is true for the data rates which were and are increasing dramatically (Figure 2). The development of balanced twisted-pair cabling systems that are used today has advanced rapidly over the last decades. Whereas in 1995 networks with transmission speeds of 100 Mbit/s were installed and operated, network speeds have increased by the factor 100 to date. Since the year 2000 copper-based networks with transmission rates of 1 Gbit/s have been installed and operated, at first in data centers, followed by work place installations. For some years now, Cat Figure 2: Increasing demand for bandwidth in networks and data centers Source IEEE802.3 6