MINER-S Station Controller. Substation Automation

Similar documents
MINER-S Station Controller

Scout-S Station Controller

extending the boundaries of technology evolution of proven technology FEATURES

Type VRLTC tap changer

Bus Bar Protection Relay B-PRO 4000

Communication Gateway COM 610. Product Guide

CPU6501 REV1.0 1 WILLOWGLEN MSC BERHAD

USER S MANUAL TP1043 series

PDD-300 pulsed diode driver

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

Enclosed Power Supplies

SCADA. SurvalentONE. STC Explorer

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

SPA-ZC 302. Profibus-DPV1/SPA Gateway. Product Guide. spa-zc302_rightco300

Remote Terminal Unit ER1000 APPLICATION FEATURES

3.2 Information of EUT

Relion 611 series. 611 series Type Test Certificate

For Transmission, Distribution and Machinery protection.

Constant Voltage Mode

SCADAPack ES. Smart RTU

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

TM221M16R controller M IO relay

SEL-3332 Intelligent Server

PMC 530 Series Advanced Multifunction Meter

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

SCADAPack ES. Smart RTU

Transformer Protection Relay

PHYSICAL INTERFACES 5406R

TU531, TU532 Terminal Unit

TM221M16TG controller M IO transistor PNP spring

Providing the missing piece in your Condition Based Monitoring platform

I/A Series HARDWARE Product Specifications

TM221ME32TK controller M IO transistor PNP Ethernet

TM221M32TK controller M IO transistor PNP

DIN Rail RTU 540CMD01 Data sheet

TM258LF42DT compact base M I/O - 24 V DC - CANopen

RT7-48V/6kW Specification

RT4F-48V/50A-WAC RECTIFIER

RT12-240V/2.4kW Rectifier Specification

TALON Network Manager- 2 & 6 Express

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

LMC058LF42 compact base - 42 I/O - 24 V DC supply

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

TF501, TF521 Terminal Bases

Autodaptive Capacitor Control M 2501B

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany

CM592 PROFIBUS Communication Module

RT4F-120V/20A-WAC RECTIFIER

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

AO523 Analog Input Module

TM221CE40T controller M IO transistor PNP Ethernet

Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

TM251MESC controller M251 Ethernet CAN

TM258LF42DT compact base M I/O - 24 V DC - CANopen

TM200CE24T controller M IO transistor Source+ Ethernet

TM221CE24R controller M IO relay Ethernet

TM258LD42DT4L compact base M I/O - 24 V DC

DATASHEET. Ultra Capacitor Charger, UCC-4

TM3DI16 module TM3-16 inputs

Cisco cbr-8 Converged Cable Access Router Supervisor 250G

CM597 Ethernet Communication Module

TM221CE40R controller M IO relay Ethernet

TM3DI16G module TM3-16 inputs spring

PRODUCT DESCRIPTION. Vertically cooled 2RU rectifiers with wide range of output modules available.

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

TM258LD42DT4L compact base M I/O - 24 V DC

Characteristics. Application RTU560. HMI unit 560HMR01. Data Sheet HMI unit 560HMR01

Output Voltage* (nom.)(adjustable)

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

RT4F-110V/25A RECTIFIER

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Energy Management BUS Adapter Type VMU-B

Universal Power Supplies

RT4B-110V/12A RECTIFIER

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

CM589 PROFINET Communication Module

TM221CE24T controller M IO transistor PNP Ethernet

Technical specifications

TM221ME16T controller M IO transistor PNP Ethernet

CM579-PNIO PROFINET Communication Module

HEC-100RTN-48QSCA Rev A1.0

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

CD522 Encoder, Counter and PWM Module

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

Features. Applications and Benefits TRC ELECTRONICS, INC

AX521 Analog Input/Output Module

TM3AI4 module TM3-4 analog inputs

TM241C40U controller M IO transistor NPN

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

CompactBlock Guard I/O EtherNet/IP Safety Modules

Arc protection relay. Features Three-phase overcurrent function. Application

TM241C24T controller M IO transistor PNP

MULTILINK ML2400 Guideform Specification

Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

QUALITROL QTMS Transformer Monitoring System

PE2G4B19L Quad Port Copper Gigabit Ethernet PCI Express Server Adapter Broadcom BCM5719 Based

SEL-2730M 24-Port Managed Ethernet Switch

Transcription:

Substation Automation

MINER-S Station Controller incorporates traditional RTU functions with new technology in a compact design MINER-S Station Controller combines the functions of a traditional RTU with the functionality of a Data Concentrator, and includes a Terminal Server and a Web Server. The MINER-S provides a balanced combination of I/O points and communication ports in a compact package, operating with just 8W in industrial temperature range. Communication Capabilities The communications capabilities allow the MINER-S to connect to multiple intelligent electronic devices (IED), either on multiple ports with multi-drop configurations, or over three Ethernet ports. Communication to the master(s) can be configured to occur via the serial ports, or via three Ethernet ports. When connected to an Ethernet LAN, one or more serial ports can be configured to act as terminal server ports. This allows a remote device (the master or other appropriate computer on the LAN) to access this port and exchange data with an external device. As an example, this feature can be used to remotely configure IEDs or upload historical data files. The MINER-S has a dedicated serial port for configuration: point monitoring, and diagnostics. A simple terminal connected to this port will act as the human interface. When connected to an Ethernet LAN, the same configuration and diagnostic operations can be performed remotely on the RTU via Telnet or a web browser. A powerful web server is also integrated within the MINER-S. This user-friendly tool allows operation, maintenance and configuration of the RTU without the need of proprietary software. Any standard web browser can be used to access the web server. Simple configuration is provided by the Points Mapping Wizard which allows points mapping of third party IEDs and I/O cards in a graphical environment. An extensive library of point maps is available for the most common IEDs available on the market, making IED point mapping a few clicks of the mouse.

Processing Freescale P1020 800MHz Dual Core Processor 64 MB FLASH Memory 1 GB SDRAM and 1Mb battery backed SRAM Nonvolatile EEPROM for system configuration Embedded Linux OS Communications 3 serial RS232 for master, IED, or terminal server 1 serial RS232 for diagnostic and configuration 1 serial RS485 for master, IED, or terminal server 3 Ethernet: 10/100/1000 Mbps Environmental -40 C to 70 C operating 0 C to 85 C storage Humidity 10-90% relative noncondensing Surge Protection per ANSI C37.90 on all I/Os Dimensions Panel mount: 9 x 8.5 x 3 (W x L x H) Power 3 Input Voltage Options: 24 Vdc 48 Vdc, 120/240 VAC, 125/250 Vdc Power Consumption: 8W maximum Time Synchronization SNTP - Simple Network Time Protocol SCADA system Large Points Database Capacity Maximum Database Size of 16,000 Points 8 Digital Outputs Select Before Operate sequence Momentary outputs 1-Form A contact rated at 10 Amps @ 250 VAC or 1 AMP @ 48 VDC 8 Analog Inputs Sampling Rate 2sec Accuracy ±0.2% of full scale Configurable dead band per point (protocol dependent) 16 Digital Inputs Alarm/Status/Accumulator Inputs Optically Isolated Inputs Scan Time 1ms for SOE, 10 ms for others Configurable for dry or wetted field contacts Internal Wetting Voltage Out: +12Vdc 2 Options for Maximum External Wetting Voltage: +48Vdc Maximum Standard +125Vdc Maximum Optional (must be specified at time of order) Master Station Protocols DNP3.0 serial and TCP/IP Modbus serial and TCP/IP IEC 60870-5-101 IEC 60870-5-104 IED Protocols DNP serial and TCP/IP Modbus RTU serial and TCP/IP SEL Protocol IEC 60870-5-101 IEC 60870-5-103 Cooper 2179

Type Tests Electromagnetic Compatibility Emissions Conducted Emissions: IEC 61000-6-4 or EN 61000-6-4 CISPR 11, EN 55011 Class A, Group 1 Radiated Emissions: IEC 61000-6-4 or EN 61000-6-4 CISPR 11, EN 55011 Class A, Group 1 Electromagnetic Compatibility Immunity Tested in accordance with IEC/EN 61000-6-5: 2015 - Electromagnetic Compatibility (EMC) - Part 6-5: Generic standards immunity for equipment used in power station and substation environment. Electrostatic Discharge: IEC 61000-4-2, EN 61000-4-2 +6 kv Contact Discharge, +8 kv Air Discharge Radiated RF Immunity: IEC 61000-4-3, EN 61000-4-3, ENV 50204 10 V/m, 0.8-1 GHz, 3 V/m, 1-6 GHz Electrical Fast Transient: IEC 61000-4-4, EN 61000-4-4 +0.5 kv + 1 kv + 2 kv on AC lines, +0.5 kv + 1 kv + 2 kv on DC, I/O lines Surge Withstand Immunity: IEC 61000-4-5, EN 61000-4-5 +0.5 kv + 1 kv Differential Mode, +0.5 kv + 1 kv + 2 kv Common Mode Conducted Disturbances Immunity: IEC 61000-4-6, EN 61000-4-6 10 V, 0.15-80 MHz, on AC, DC 3 V, 0.15-80 MHz, on I/O Lines Magnetic Field Immunity: IEC 61000-4-8, EN 61000-4-8 100A/m - Continuous, 1kA/m for 1 sec AC Voltage Dips/Short Interruption: IEC 61000-4-11, EN 61000-4-11 60% UT during 60 cycles, 30% UT during 1 cycle Conducted RF Immunity, 15-150 KHz: IEC 61000-4-16, EN 61000-4-16 30 Vrms Continuous Disturbance on DC, I/O, 300 Vrms 1 sec Disturbance DC, I/O Damped Oscillatory Wave Immunity: IEC 61000-4-18, EN 61000-4-18 2.5 kv Common Mode (1 MHz) on AC/DC/I/O line, 1 kv Differential Mode (1 MHz) on AC/DC/I/O lines Harmonic Current Emissions: IEC 61000-3-2, EN 61000-3-2 Class A (Other), Class B (Portable Equipment), Class C (Lighting Equipment) Voltage Fluctuation and Flicker: IEC 61000-3-3, EN 61000-3-3 Environmental Cold: IEC 61000-2-1, 18 hours at -40 C Damp Heat, Cyclic: IEC 61000-2-30, 25 C to 55 C, 6 cycles, Relative Humidity: 95% Dry Heat: IEC 61000-2-2, 18 hours at +70 C

Control your critical network operations with confidence With Survalent, you can control your critical network operations with confidence. We re the most trusted provider of advanced distribution management systems (ADMS) for electric, water/wastewater, gas, and transit utilities across the globe. We have had no failures to date on any of these RTUs. The performance is outstanding. Thank you for creating such a reliable product. - Sho-Me Power Electric Cooperative Over 600 utilities in 30 countries rely on the SurvalentONE platform to effectively operate, monitor, analyze, restore, and optimize operations. By supporting critical utility operations with a fully integrated solution, our customers have significantly improved operational efficiencies, customer satisfaction and network reliability. Our unwavering commitment to excellence and to our customers has been the key to our success for over 50 years. info@survalent.com survalent.com 905-826-5000 2018 Survalent Technology Corporation. All rights reserved. Product & company names mentioned herein may be trademarks or registered trademarks of their respective owners. Errors & omissions excepted.