Upgrading from MICRO/MIDIMASTER 2 to MICRO/MIDIMASTER 3

Similar documents
5 MICROMASTER 440 specifications

5 MICROMASTER 420 specifications

Power 004=0.4kW 015=1.5kW. Delta Variable Frequency Drive

Product Overview. PowerFlex 520-Series AC Drives Feature. Modular Design. Packaging and Mounting. Optimized Performance

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

02/11/2015

Easy To Use OEMS Take Note

lnvertek Drives.com ct,ve ELECTRICAL SUPPLIERS LTD

MOTOR STARTERS & VARIABLE SPEED DRIVES Variable speed drives

SENSORLESS VECTOR CONTROL

CATALOG SELECTION / PRODUCT SELECTION

Motor Controllers AC Variable Frequency Drives Type Variflex 3 RVLF Advance

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Jussi Rantanen, Component AC, December 29, 2009 ABB general machinery drives ACS355. ABB Group February 12, 2010 Slide 1

HVAC Products. Introducing the SED2 Variable Frequency Drives

MICROMASTER 4 th. Generation. A&D SD Thailand MM4 Next.Generation /50

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

IEC Contactors. Auxiliary Contact Blocks GENERAL

SPX 1hr product overview Eaton Corporation. All rights reserved.

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

Technical Data and Specifications. Table 1. LCX9000 Specifications. Drive Efficiency > 95% Power Factor (Displacement).96

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

VLT Micro Drive. Ready Set Go!

Motor Controllers AC Variable Frequency Drives Type Variflex 3 RVLF Advance

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

Product Discontinuation Notices. Discontinuation Notice of Multi-function Compact Inverter 3G3MX Series

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

Motor Controllers Variable Frequency AC Drives Type VariFlex 2 RVCF

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

SD250 VARIABLE SPEED DRIVE

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

SIMOREG DC-MASTER. Operating Instructions. 6RA70 Series. Microprocessor-Based Converters from 6kW to 2500kW for Variable-Speed DC Drives

Optidrive Applications Support Library

SPARE CONNECTORS KTM 2014

OPTIDRIVE PLUS 3 GV 3 rd Generation Vector Control AC Variable Speed Drive kW

PowerFlex 40 Sample Specification

Trio Application Control System Instruction Sheet

8200 vector frequency inverter

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

Operating Instructions

SPAREPARTSCATALOG: CONNECTORS SPARE CONNECTORS KTM ART.-NR.: 3CM EN

VARIABLE SPEED DRIVE

Technical Catalogue Softstarters

idrive 2 AC Variable Speed General Purpose Drives kW Affordable drives evolved

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

S5-115U. Application

Selection Guide. PowerFlex Digital DC Drive

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Operating comfort redefined Frequency Inverters M-MAX

VS mini J7 to J1000 Replacement Instructions

AC DRIVES Catalogue Electronic for drives. Quality is our Drive.

Time Counters mini "h", DC Version

SED2 Variable Frequency Drives

PTC/PT100 board 2.0 Option

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Section 16. Drives AF-650GP General Purpose Drive. Standard Specifications. Environmental Conditions. Logic Controller (LC) Sequencer

PSU. User s manual. Rev. 0

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

2-Type Series Pressurized Closures

SmartVFD HVAC232/402 GENERAL FEATURES SPECIFICATIONS. Frequency drives. Mains Connection Input voltage U in : Supply Network Networks:

Specification Number: Product Name: FRENIC-Mega AC Drives for General Purpose Applications (½ - 150Hp at 230V and ½ Hp at 460V)

SED2 Variable Frequency Drives

PGR-2601 MANUAL DC GROUND-FAULT RELAY

D SERIES AM16 PREMIUM DRIVE FOC VECTOR CONTROL FOR IM AND PM MOTORS AM16 PREMIUM DRIVE FOC VECTOR CONTROL FOR IM AND PM MOTORS

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVLF

Motor Control and Protection Unit M10x AO Module User Guide

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

22ND CENTURY_J1.xls Government Site Hourly Rate

Integrated Multi-Function

PTC/PT100 board 2.0 Option

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV1200A kv kva

ATV1200A kv kva

C-DIAS Analogue Conversion Module CAM 124 for eight 0 10V DC inputs and four 10V outputs

8200 vector frequency inverter

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

Neon pr. ph/ ORP measurement. Applications. Description

Important Safety Notice

YASKAWA AC Drive V1000 Supplementary Documentation for Software Upgrade. Preface

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

PowerFlex 4-Class Options

Quick Start Guide For GVX9000 AF Drives

INTRODUCING THE S V ADJUSTABLE SPEED DRIVE

Y07/1-01(V1.0) Goodrive20 Series Vector Control Inverter

vacon nx user manual basic i/o boards expander i/o boards adapter i/o boards ac drives

DC1 Series 10 min Product Overview Eaton Corporation. All rights reserved.

The VLT Micro Drive Small drive maximum strength and reliability

Instruction Manual (Supplementary) Totally-Enclosed Box Type Inverter

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

Simply Smart! Altivar to 600V AC / 1 & 3-phase / 0.25 to 20HP. All in a high performance package! Easy to Use, Plug and drive!

Transcription:

The new MICRO/ Vector range is designed to replace the existing MICRO/ in most applications without changing parameter settings, mounting arrangements, etc. In some cases the new (standard) range will provide the necessary functionality. The tables below list the basic differences. CONTENTS Page 1. Mounting / Wiring... 1 2. Features and Specifications... 2 3. Terminal Connections... 3 4. Parameters... 4 5. Equivalents Table... 5 6. Equivalents Table (IP21/NEMA 1)... 6 Equivalents Table (IP56/NEMA 4)... 7 7. Table of Similar Types... 8 8. Options... 9 1. Mounting / Wiring 1.1 Mechanical, Vector. Larger units (frame size B and C) are identical footprint to, but are slightly deeper. Frame size A is higher, but narrower and has two fixing points, not four. DIN rail mounting is possible. Frame size B and C have gland terminations; Frame size A use optional plate, making the unit higher and providing NEMA 1 terminations. Optional footprint filters, where used, fit under the unit. Braking resistors are now mounted alongside the unit ( Vector). Vector Identical overall size to previous units, but new frame size 7 for higher power units (75kW Constant Torque, 90kW Variable Torque). Integrated versions and IP56 units will also be available in all ratings. 1.2 Electrical, Vector. Power connections in two rows (supply at top) with PE on left. Control terminals re-arranged, but Analogue input terminals 1 to 4 unchanged. See table. Vector terminals 1-26 in three different rows. See table. Vector Power terminals as previous units. Control terminals as Vector in two rows with second analogue output terminal 27 (see table on page 3) - 1-19/12/97

2. Features and Specifications 2 nd Gen Power Range 120W - 3kW 230V 1AC 120W - 4kW 230V 3AC 370W - 7.5kW 400V 3AC Voltage Range 208-230V +15%/-10% 380-500V +/- 10% 3 rd Gen 6SE92 120W - 3kW 230V 1AC 120W - 4kW 230V 3AC 370W - 7.5kW 400V 3AC 208-240V +/-10% 380-500V +/- 10% Vector 120W - 3kW 230V 1AC 120W - 4kW 230V 3AC 370W - 7.5kW 400V 3AC 208-240V +/-10% 380-500V +/- 10% Vector 5.5kW - 45kW 230V 3AC 11kW - 75kW 400V 3AC 11kW - 37kW 575V 3AC 208-240V +/-10% 380-500V +/- 10% 525-575V +/- 15% Input Frequency 47-63Hz 47-63Hz 47-63Hz 47-63Hz Power Factor cos Φ 0.98, Total λ 0.7 cos Φ 0.98, Total λ 0.7 cos Φ 0.98, Total λ 0.7 cos Φ 0.98, Total λ 0.7 Operating 0-40 C 0-50 C 0-50 C 0-40 C Temperature Storage -40 to +70 C -40 to +70 C -40 to +70 C -40 to +70 C Temperature Relative 95% non-condensing 95% non-condensing 95% non-condensing 95% non-condensing Humidity Degree of protection IP21 / NEMA 1 IP20 / NEMA 1 (FSA units require optional gland plate to meet NEMA1) IP20 / NEMA 1 (FSA units require optional gland plate to meet NEMA1) IP21 / NEMA 1 (Optional IP56 / NEMA 4 also available) Cooling Method Fan cooling Software controlled fan Software controlled fan Fan cooling cooling cooling Output 0-650Hz 0-400Hz 0-650Hz 0-650Hz Frequency Output 0.01 0.01 0.01 0.01 Frequency Resolution Overload Capability 150% for 60 secs referred to rated current 150% for 60 secs referred to rated current 200% for 3 secs 150% for 60 secs referred to rated current 200% for 3 secs 150% for 60 secs referred to rated current Control Method V/f,FCC V/f SVC,FCC,V/f SVC,FCC,V/f Inverter 97% 97% 97% 97% Efficiency Digital Inputs 5 3 6 6 Analogue input 1 Analogue input 2 Analogue output 1 0-10V / PID input 0-10V / PI input 0-10V,0/4-20mA -10V / +10V bipolar n/a n/a 0-10V,0/4-20mA PID input, 0/4-20mA n/a 0/4-20mA with 500Ω max. load with 500Ω max. load 8 bit resolution 0-10V,0/4-20mA -10V/ +10V bipolar 0-10V,0/4-20mA PID input, 0/4-20mA 500Ω max. load Analogue output 2 n/a n/a n/a 0/4-20mA 500Ω max. load Relay output 1 30VDC 2A, 240VAC 0.8A 30VDC 1A, 110VAC 0.3A 30VDC 2A, 240VAC 0.8A 30VDC 2A, 240VAC 0.8A Relay output 2 30VDC 2A, 240VAC 0.8A 30VDC 1A, 110VAC 0.3A 30VDC 2A, 240VAC 0.8A 30VDC 2A, 240VAC 0.8A RS485 Interface D-type/Terminal strip D-type D-type / terminal strip D-type / terminal strip Braking Built-in (MM) n/a Built-in Optional external module Chopper External (MD) Compound No Yes Yes Yes Braking Fast Current No Yes Yes Yes Limit Motor Protection Dedicated PTC input PTC input on digital input Dedicated PTC input Dedicated PTC input - external Motor Protection - internal I²t Thermal Relay I²t I²t - 2-19/12/97

3. Terminal Connections The terminals on the new units have additional features and the terminals are generally arranged to accommodate these. Note that this table serves as an approximate guide and exact specification should be checked before installation: Function MICRO- MASTER MICRO- MASTER 3 rd Gen 6SE92 MICRO- MASTER Vector 10V reference 1 1 1 0V 2 2,9,D5 2/D5 Analogue input Positive 3 3 3 Analogue input Negative 4 4 4 PTC Connection 5-14 PTC Connection 6-15 +15 Supply for digital inputs 7 8 9 Digital input 1 8 5 5 Digital input 2 9 6 6 Digital input 3 10 7 7 Digital input 4 11-8 Digital input 5 12-16 RS485 P+ input 13 D3 25/D3 RS485 N - input 14 D8 24/D8 5V power for OPm2 etc. - D6 26*/D6 Protective Earth 15-23** Relay RL1 normally closed 16 18 Relay RL1 normally open 17 10 19 Relay RL1 common 18 11 20 Relay RL2 normally open 19-21 Relay RL2 common 20-22 PID input + MM MD 3 1 - - 10 10 PID input - (0V) MM MD 2 3-11 11 Analogue output + MM MD 1 2-12 12 Analogue output - MM MD - - - 13 13 Analogue output 2+ MD - - 27 Digital input 6 - - 17 * 23 on Vectors **26 on Vectors. - 3-19/12/97

4. Parameters. The 3 rd generation range of MICRO and use a parameter set based on the previous units. Therefore parameter selections used on earlier units can usually be used with new units without changes. The following table shows the main parameters which have additional or changed values. Parameter Values Remarks P006 3 Digital set point addition now possible P019 Skip frequency range now adjustable P023 3 +/- 10V input now possible P024 2 Scaling of the digital set point by the analogue input now possible. P026 Second analogue output ( Vector only) P027-29 Additional Skip Frequencies. P356 Additional Digital Input P051-55, P356 20 22 23 24 Additional Values: Watchdog timer trip Download parameter set 1 from OPm2 Download parameter set 2 from OPm2 Change from analogue input 1 to analogue input 2 P057 Watchdog timer time (see above) P066 Compound Braking P075 1 Braking resistor value no longer necessary. P074 4-7 Additional de-rating settings - inverter trips P077 3 Sensorless Vector Operation P080 Motor Power Factor Value required P140-3 Most recent fault codes P186 Instantaneous Current Limit P323 Second analogue input options P386 1-20 Sensorless Vector control loop gain. P725/6 Analogue output selections - 4-19/12/97

5. Equivalents Table Ersatztypen Drive type Integral Integrierte (1 st Gen) 6SE30 Upgrading from MICRO/ 2 (2 nd Gen) MIICROMASTER Vector (3 rd Gen) Umrichter Typ Order No / MLFB Order No / MLFB Order No / MLFB MM12 ä - 10-7BA40 MM25 ä 11-5BA40 11-5BA40 MM37 ä 12-1BA40 12-1BA40 MM55 ä 12-8BA40 12-8BA40 MM75 ä 13-6BA40 13-6BA40 MM110 ä 15-2BB40 15-2BB40 MM150 ä 16-8BB40 16-8BB40 MM220 ä 21-0BC40 21-0BC40 MM300 ä 21-3BC40 MM12/2 10-7CA40 MM25/2 6SE3011-5BA00 11-5CA40 11-5CA40 MM37/2 6SE3012-0BA00 12-1CA40 12-1CA40 MM55/2 6SE3012-6BA00 12-8CA40 12-8CA40 MM75/2 6SE3013-4BA00 13-6CA40 13-6CA40 MM110/2 6SE3014-8BC00 15-2CB40 15-2CB40 MM150/2 6SE3016-4BC00 16-8CB40 16-8CB40 MM220/2 6SE3019-0BC00 21-0CC40 21-0CC40 MM300/2 21-3CC40 21-3CC40 MM400/2 21-8CC40 MM37/3 11-1DA40 MM55/3 11-4DA40 MM75/3 12-0DA40 MM110/3 12-7DA40 MM150/3 14-0DC40 14-0DA40 MM220/3 15-8DC40 15-8DB40 MM300/3 17-3DC40 17-3DB40 MM400/3 21-0DC40 21-0DC40 MM550/3 21-3DC40 21-3DC40 MM750/3 21-5DC40-5 - 19/12/97

6. Equivalents Table Ersatztypen Protection IP21, NEMA 1 Schutzart IP21, NEMA 1 Drive type SIMOVERT P 6SE21 Vector Vector with Integral Umrichter Typ Order No / MLFB Order No / MLFB Order No / MLFB Order No / MLFB MD550/2 22-3CG40 22-3CG40 22-3CG50 MD750/2 23-1CG40 23-1CG40 23-1CG50 MD1100/2 24-2CH40 24-2CH40 24-2CH50 MD1500/2 25-4CH40 25-4CH40 25-4CH50 MD1850/2 26-8CJ40 26-8CJ40 26-8CJ50 MD2200/2 27-5CJ40 27-5CJ40 27-5CJ50 MD3000/2-31-0CK40 31-0CK50 MD3700/2-31-3CK40 31-3CK50 MD4500/2-31-5CK40 31-5CK50 MD750/3 6SE2113-3AA21 21-7DG40 21-7DG40 21-7DG50 MD1100/3 6SE2117-3AA21 22-4DG40 22-4DG40 22-4DG50 MD1500/3 6SE2122-3AA21 23-0DH40 23-0DH40 23-0DH50 MD1850/3 6SE2127-3AA21 23-5DH40 23-5DH40 23-5DH50 MD2200/3 6SE2133-3AA21 24-2DJ40 24-2DJ40 24-2DJ50 MD3000/3 6SE2142-3AA21 25-5DJ40 25-5DJ40 25-5DJ50 MD3700/3-26-8DJ40 26-8DJ40 26-8DJ50 MD4500/3 - - 28-4DK40 28-4DK50 MD5500/3 - - 31-0DK40 31-0DK50 MD7500/3 - - 31-4DK40 31-4DK50 MD220/4-13-8FG40 MD400/4-16-1FG40 MD550/4-18-0FG40 MD750/4 21-1FG40 21-1FG40 MD1100/4 21-7FG40 21-7FG40 MD1500/4 22-2FH40 22-2FH40 MD1850/4 22-7FH40 22-7FH40 MD2200/4 23-2FJ40 23-2FJ40 MD3000/4 24-1FJ40 24-1FJ40 MD3700/4 25-2FJ40 25-2FJ40-6 - 19/12/97

6. Equivalents Table Ersatztypen Protection IP56, NEMA 4/12 Schutzart IP56, NEMA 4/12 Drive type Vector Umrichter Typ Order No / MLFB Order No / MLFB MD550/2 22-3CS45 22-3CS45 MD750/2 23-1CS45 23-1CS45 MD1100/2 24-2CS45 24-2CS45 MD1500/2 25-4CS45 25-4CS45 MD1850/2 26-8CS45 26-8CS45 MD2200/2 27-5CS45 27-5CS45 MD3000/2-31-0CS45 MD3700/2-31-3CS45 MD4500/2-31-5CS45 MD750/3 21-7DS45 21-7DS45 MD1100/3 22-4DS45 22-4DS45 MD1500/3 23-0DS45 23-0DS45 MD1850/3 23-5DS45 23-5DS45 MD2200/3 24-2DS45 24-2DS45 MD3000/3 25-5DS45 25-5DS45 MD3700/3 26-8DS45 26-8DS45 MD4500/3-28-4DS45 MD5500/3-31-0DS45 MD7500/3-31-4DS45 MD220/4-13-8FS45 MD400/4-16-1FS45 MD550/4-18-0FS45 MD750/4 21-1FS45 21-1FS45 MD1100/4 21-7FS45 21-7FS45 MD1500/4 22-2FS45 22-2FS45 MD1850/4 22-7FS45 22-7FS45 MD2200/4 23-2FS45 23-2FS45 MD3000/4 24-1FS45 24-1FS45 MD3700/4 25-2FS45 25-2FS45-7 - 19/12/97

7. Table of Similar Types (check specifications for suitability as alternatives!) Vergleichbare Typen (Überprüfen Spezifikation für Kompatibilität!) Drive type Integral Integrierte (1 st Gen) 6SE30 Upgrading from MICRO/ 2 (2 nd Gen) Junior 6SE91 MIICROMASTER Vector (3 rd Gen) (3 rd Gen) 6SE92 Umrichter Typ Order No / MLFB Order No / MLFB Order No / MLFB Order No / MLFB Order No / MLFB MM12 ä - 6SE9110-7BA53 10-7BA40 6SE9210-7BA40 MM25 ä 11-5BA40 6SE9111-5BA53 11-5BA40 6SE9211-5BA40 MM37 ä 12-1BA40 6SE9112-0BA53 12-1BA40 6SE9212-1BA40 MM55 ä 12-8BA40 6SE9112-6BA53 12-8BA40 6SE9212-8BA40 MM75 ä 13-6BA40 6SE9113-4BA53 13-6BA40 6SE9213-6BA40 MM110 ä 15-2BB40 15-2BB40 6SE9215-2BB40 MM150 ä 16-8BB40 16-8BB40 6SE9216-8BB40 MM220 ä 21-0BC40 21-0BC40 6SE9221-0BC40 MM300 ä 21-3BC40 6SE9221-3BC40 MM12/2 6SE9110-7CA13 10-7CA40 6SE9210-7CA40 MM25/2 6SE3011-5BA00 11-5CA40 6SE9111-5CA13 11-5CA40 6SE9211-5CA40 MM37/2 6SE3012-0BA00 12-1CA40 6SE9112-0CA13 12-1CA40 6SE9212-1CA40 MM55/2 6SE3012-6BA00 12-8CA40 6SE9112-6CA13 12-8CA40 6SE9212-8CA40 MM75/2 6SE3013-4BA00 13-6CA40 6SE9113-4CA13 13-6CA40 6SE9213-6CA40 MM110/2 6SE3014-8BC00 15-2CB40 15-2CB40 6SE9215-2CB40 MM150/2 6SE3016-4BC00 16-8CB40 16-8CB40 6SE9216-8CB40 MM220/2 6SE3019-0BC00 21-0CC40 21-0CC40 6SE9221-0CC40 MM300/2 21-3CC40 21-3CC40 6SE9221-3CC40 MM400/2 21-8CC40 6SE9221-8CC13 MM37/3 6SE9111-1JA13 11-1DA40 6SE9211-1DA40 MM55/3 6SE9111-4JA13 11-4DA40 6SE9211-4DA40 MM75/3 6SE9113-4JA13 12-0DA40 6SE9212-0DA40 MM110/3 6SE9112-7JA13 12-7DA40 6SE9212-7DA40 MM150/3 14-0DC40 6SE9113-7JA13 14-0DA40 6SE9214-0DA40 MM220/3 15-8DC40 15-8DB40 6SE9215-8DB40 MM300/3 17-3DC40 17-3DB40 6SE9217-3DB40 MM400/3 21-0DC40 21-0DC40 6SE9221-0DC40 MM550/3 21-3DC40 21-3DC40 6SE9221-3DC40 MM750/3 21-5DC40 6SE9221-5DC40-8 - 19/12/97

8. Options Option Type (2 nd Gen) MIICROMASTER Vector (3 rd Gen) (3 rd Gen) 6SE92 Vector Option Typ Order No / MLFB Order No / MLFB Order No / MLFB Order No / MLFB Order No / MLFB SIMOVIS 90-1XX87-90-0XX87-90-0XX87-90-1XX87-90-0XX87- Profibus Module 86-4AK00 90-0XX87-8PB0 90-0XX87-8PB0 86-4AK00 90-0XX87-8PB0 Clear Text Display (OPm) 90-0XX87-90-0XX87-90-0XX87-90-0XX87-90-0XX87- Electronic Braking Unit (400/460V) built-in built-in - 90-0DX87-2DA0 90-0DX87-2DA0 Electronic Braking Unit (230V) built-in built-in - 90-0CX87-2DA0 90-0CX87-2DA0 Note: SIMOVIS, Profibus Modules and Clear Text Display modules from 2 nd generation / () ranges are not compatible with the 3 rd generation / Vector product range. - 9-19/12/97