SPECIALTY FLOODLIGHTING. ACP Series LED ACP1 & ACP2 LED Floodlighting

Similar documents
Autobahn Series ATB2 Roadway Lighting

ROADWAY LIGHTING. Autobahn Series ATB0 & ATB2 LED Roadway

ROADWAY & SECURITY LIGHTING. Autobahn Series ATBS LED Roadway & Security

Autobahn Series ATBM Roadway

Autobahn Series ATBM Roadway

ROADWAY LIGHTING. Autobahn Series ATB0 & ATB2 LED Roadway

ROADWAY LIGHTING. Autobahn Series ATBL, ATBM & ATBS LED Roadway

AREA LIGHT GT SERIES FEATURES & BENEFITS TECHNICAL PARAMETERS

Night Falcon LED floodlight series. Lumark

PRECISION LED HIGH MAST LIGHTING

Project: Catalog No.: CALCULATED LIFETIME. Fixture Type: 100,000 HOURS. Notes:

12" LED RoundBack Adjustable Flood Light, Heritage Series

Item # Part # Wattage Lumens Kelvin Voltage Type Distribution Custom Options Available*

Premium Area Light 10 C O N T R O LLE D

Light Engine. Tilt of. Mounting. Pole Series K. R3W Type III Distribution Wide R3N Type III Distribution Narrow R5 Type V Distribution

UFLD LED utility floodlight. Streetworks

FLOOD LIGHT. FINISHES: Satin bronze finish standard Also available in silver Additional colors available for custom orders

Premium Area Light QMP Unique Fixture

Premium Area Light QMP Unique Fixture

LED FLOODS. Round Back VFloods. Benefits and Features. Accessories (Order as separate line items)

THE ARIA. LED AREA LIGHT. eran industrial. ARL SERIES

Cape Girardeau, MO 43W / 65W / 83W 131W / 165W. StreetSense LED Street Light for roadway and area illumination 190W / 252W.

Features. Product Overview. Wattage: Lumen Output: Color Temp: Dimming: Construction:

24" KittyHawk LED Area Light, Heritage Series

FFC SERIES CONTRACTORS

Features. Product Overview. Wattage: Lumen Output: Color Temp: Dimming: Construction:

FSL-7. Hubbell Outdoor Lighting s sleek and stylish FL series floodlights

QuadroMAX LED FIXTURE QM SERIES

LFS - SFL LED Small Flood

24" KittyHawk LED Area Light, Heritage Series

Arca LED 5YEAR LED WARRANTY. Order Code: Pole Order Code: Customer: Date: Project: Qty: Type: ACL ACL. R2 Type II Distribution.

Features RAPTOR LED AREA / FLOOD

XSP Series XSP1 LED Street/Area Luminaire Single Module Version C

Talon LED Architectural Area Luminaire

* Use only when exposed to salt spray and harsh chemicals. This option is not required for normal outdoor exposure! 5-year limited warranty.

XSP High Output Series XSP1 High Output LED Street/Area Luminaire Single Module

Halco AL-Series Area Light

XSP Series XSP2 LED Street/Area Luminaire Double Module Version B

Suitable for applications requiring 3G testing prescribed by

LFS - SAL LED Small Area Light

LFS - LAL LED Large Area Light

LFS - SAL LED Small Area Light

Area Light Large. Performance Data. Fixture Information. Lumen Output: Lumens Per Watt (typical): CCT: Distribution: Lifespan: Ratings & Certificates

OSQ Series OSQ LED Area/Flood Luminaire Medium

XSP Series XSP2 LED Street/Area Luminaire Double Module Version C

Floodlights. ClearScape. Medium, CSFM. SF Slip Fitter Mount (fits to 2-3/8" O.D. tenon) SP Spot. RSP Rectangular Spot.

* Use only when exposed to salt spray and harsh chemicals. This option is not required for normal outdoor exposure! 5-year limited warranty.

Area Light Small. Performance Data. Fixture Information. Lumen Output: Lumens Per Watt (typical): CCT: Distribution: Lifespan: Ratings & Certificates

LED AREA LIGHT SERIES

Industrial Baymaster HL LED Luminaire High Bay for Ordinary Locations

Ventus LED Architectural Area Luminaire

LFS - SAL LED Small Area Light

FLL.RGBW. Noribachi Product Family Brochure and Specifications. Noribachi.com /

lumenbeam SPECIFICATION SHEET

XSP Series XSP1 LED Street/Area Light Single Module Version B

McGraw-Edison TT TOPTIER SITE LED

LED SLIM AREA LIGHTS AR-MAL SERIES

* Optional TLPC shown. Mounting for Square Pole ORDERING INFORMATION 72W 108W 141W 188W 108LED 141LED 188LED. DM 0-10V Dimming. (Std.

Industrial Baymaster LED Luminaire High Bay for Ordinary Locations

Type. Suitable for applications requiring 3G testing prescribed by

18" Wall Director PicoEmitter LED kl_wd18eled_spec.pdf TYPE APPROVALS

AL SERIES. AL Series - 75 Watts. Key Features & Benefits: Technical Specifications: Additional Options: ESL. Reference Guide WATTS GENERATION COLOR

Archeon LED roadway luminaire. Streetworks

McGraw-Edison TT TOPTIER SITE LED

LFS - SAL LED Small Wall Pack

LFS - LAL LED Large Wall Pack

LENDA. BBE LED Roadway Lighting Luminaire LENDA TM series V1: LDA-15/01/17. Performance Data:

Cape Girardeau, MO 40W / 60W / 80W 120W / 160W. StreetSense Series LED Street Light for roadway and area illumination 180W / 240W.

SBK Series LED Area Light

* Use only when exposed to salt spray and harsh chemicals. This option is not required for normal outdoor exposure! 5-year limited warranty.

OSQ Series OSQ LED Area/Flood Luminaire Large

* Use only when exposed to salt spray and harsh chemicals. This option is not required for normal outdoor exposure! 5-year warranty.

Avista LED Light Engine

PROJECT: PREPARED BY:

ET LED Entablature Large PicoEmitter LED kl_eteled_spec.pdf

CITY OF BOISE SPECIFICATIONS FOR LIGHT EMITTING DIODE (LED) STREET LIGHTING Effective 1 Feb, 2018

OSQ Series OSQ LED Area/Flood Luminaire Medium

14" Wall Director PicoEmitter LED kl_wd14eled_spec.pdf TYPE APPROVALS

Roadway. HighFocus. HFL High mast LED: 92, 184 and 276 LED. Twist-Lock Receptacle. Standard: Standard: DD 1 Dimmable driver 0-10V

SET LED Entablature Small PicoPrism LED kl_setpled_spec.pdf

Input Voltage: V. Efficacy. Dimming: 0-10V standard dimming capability.

BBE LED Roadway Lighting Luminaire LSI TM series

Vigilant LED Floodlight - UL / CSA for Indoor and Outdoor Industrial Applications

PKG-304-5M-DM. 304 Series Parking Structure Luminaire Type V Medium Direct Mount. Product Description. Performance Summary

RA25 25" Era PicoEmitter LED kl_ra25eled_spec.pdf

EcoSpec Floodlight Wash

Lineal SPECIFICATIONS: LED Luminaire STRUCTURA INC. FIXTURE TYPE: PROJECT NAME:

AE21 21" Era Acorn PicoEmitter LED kl_ae21eled_spec.pdf

Available Beam Angles 8, 15, 30, 45, 40 x 9, 60 x 20 Shielding and Glare Control. EasyGlow TM glare reduction technology

SRS Solitaire PicoEmitter LED kl_srseled_spec.pdf

SAR The Archetype Small PicoEmitter LED kl_sareled_spec.pdf

Typical Applications Heavy industrial Light manufacturing Warehousing Large indoor ORDERING INFORMATION V V V 2

Tellus 22 LED Area Light

Mirada - XALM Outdoor LED Area Light

Efficacy. Dimming: 0-10V standard dimming capability.

PROJECT: PREPARED BY:

VRDN LED Area, Site and Roadway Luminaire

AREA LIGHT SERIES OUTDOOR FIXTURE

Indoor/Outdoor Modular Solution for Commercial Applications. series

Light Engine 6TL TL mA/60w 500mA/87w

Transcription:

SPECIALTY FLOODLIGHTING ACP Series LED ACP1 & ACP2 LED Floodlighting

SPECIALTY FLOODLIGHTING The ACP Series LED ACP1LED & ACP2LED The ACP LED is a sustainable solution for floodlighting applications with two models to choose from; the ACP1 (medium) and the ACP2 (large). The ACP1 offers lumen packages for direct replacement for 100-400 watt floods. The ACP 2 offers lumen packages for direct replacement for 400-1000 watt floods.

Key Features Optimized thermal management system for maximum performance, long life, and reliability L70 LED and driver life greater than 100,000 hours (20 years operation) Optional tool-less entry and prewired three stage terminal block reduce installation time NEMA 3 pin locking style photocontrol receptacle comes standard on all product Mounting options include tenon slipfitter knuckle, galvanized steel yoke or painted steel yoke Segmented high performance internal reflectors are designed for superior field to beam ratios, uniformity, and spacing Standard correlated color temperatures (CCT) are 4000K and 5000K, 70CRI minimum Robust design with IP66 rating, 2G vibration rating, and a super durable polyester paint finish with 2500 hour salt fog rating Applications Parking Lots Building Facades Schools/Campuses Military Bases Industrial Parks Substations Recreation Centers Auto dealerships

Optical Performance The ACP LED Series is a direct replacement for installed high intensity discharge (HID) floodlights. The chart below gives general guidance on replacement of ACP1 and ACP2 to common HID floods. Replacement HID wattage CWA type Modules Lumens LED Wattage LPW Savings ACP2 1000 HPS 1100 9COB/10A 33,060 363 91 67% ACP2 1000 MH 1070 8COB/10A 29,989 325 92 70% ACP2 750 MH 820 7COB/10A 26,100 287 91 65% ACP1 400 HPS 464 6COB/10A 22,797 240 95 48% ACP1 400 MH 464 5COB/10A 19,176 202 95 56% ACP1 250 HPS 295 3COB/10A 11,730 120 98 59% ACP1 250 MH 298 3COB/07A 8,429 80 105 73% ACP1 150 HPS 190 2COB/10A 7,760 82 95 57% IP66 Rated Luminaire Lineman Friendly Terminal Block Quick Disconnect for Drive Power Input Double-Articulating Captive Hinge Quick Disconnect for Drive Power Input Surge Protection ANCI cat. C rated-10kv/5ka State-of-the-Art Drivers (700mA, 1000mA) Removable Door

Mechanical Design With energy savings exceeding 50% and expected service life over 20 years, the ACP LED luminaire excels at meeting the challenges associated with flood lighting. By combining the robust mechanical design features with the optical expertise and permanence of glass, this luminaire is designed as a direct retrofit for both yoke and knuckle mount applications. ACPLED Pre-wired 3 stage Terminal Block 3-Pin Locking Style Receptacle (standard) Optional Tool-less Stainless Steel Latches Robust Thermal Management System for Long Life Tenon Mount Prewired to Knuckle Wiring Chamber Standard Cord Grip on Yoke Mount Standard Wraparound Yoke Mount Standard Configuration Includes Stainless Door Closure Bolts Durable Glass Lens Optional Tool-less Entry Trigger Latch (Stainless Steel) Die-Cast Low Copper Aluminum Housing Knuckle Mount Wiring Chamber

ACP Series - ACP1LED & ACP2LED ORDERING INFORMATION Example: ACP1LED 207A 120 55 4K TM BK 05 Series Performance Package Voltage Nema Pattern ACP1LED ACP2LED Flood Flood 207A 1 210A 1 307A 1 310A 1 407A 1 410A 1 507A 1 510A 1 607A 1 610A 1 2 Modules, 700mA Driver 2 Modules, 1050mA Driver 3 Modules, 700mA Driver 3 Modules, 1050mA Driver 4 Modules, 700mA Driver 4 Modules, 1050mA Driver 5 Modules, 700mA Driver 5 Modules, 1050mA Driver 6 Modules, 700mA Driver 6 Modules, 1050mA Driver 707A 2 710A 2 807A 2 810A 2 907A 2 910A 2 7 Modules, 700mA Driver 7 Modules, 1000mA Driver 8 Modules, 700mA Driver 8 Modules, 1000mA Driver 9 Modules, 700mA Driver 9 Modules, 1050mA Driver 120 120V 347 347V 480 480V MVOLT Mulit-volt (120-277) 55 5 X 5 65 6 X 5 66 6 X 6 Color Temperature (CCT) Mounting Paint Cord Length 7 Cord Type 7 Misc 4K 5K 4000K 5000K TM YK 3 YG 3 Tenon Slipfitter - Knuckle Yoke Painted Yoke Galvanized BZ BK GY WH GI Bronze Black Gray White Graphite 04 4 05 5 06 6 08 8 10 10 12 12 15 15 20 20 25 25 30 30 63 16-3 43 14-3 23 12-3 TL NL Tool Less Entry Nema Label Options Controls (blank) 7 P5 7 NR 4 PCSS PCL1 4 PCL3 4 PCL4 4 SH 4 DE 5,6 VE 5,6 DM 4,5 3-Pin Photocontrol Receptacle (standard) 5-Pin Photocontrol Receptacle No Photocontrol Receptacle Solid State Lighting Photocontrol (120-277V) Solid State Long Life Photocontrol (120-277V) Solid State Long Life Photocontrol (347V) Solid State Long Life Photocontrol (480V) Shorting Cap ROAM CONCIERGE Dimming Control ROAMVIEW Dimming Control 0-10VDimmingControl (controls provided by others) Accessories (Shipped Separately) ACP2LEDFV- 9,10 Full Visor ACP2LEDUBV- 9,11 Upper/Bottom Visor ACP2LEDVG 12 Vandal Guard ACP2LEDWG 13 Wire Guard Notes: 1. Available with ACP1LED only 2. Available with ACP2LED only 3. Requires cord length and cord type 4. Not available with DM, NR, PCL1, PCL3, PCL4, PCSS, SH, or VE 5. Not available with DE, VE options 6. Specifies a ROAM dimming enabled fixture with a dimming control module factory installed. NEMA photocontrol receptacle required. Additional hardware and services required ROAM deployment must be purchased separately 7. Not available with NR 8. Not available with TM mounting. Must be combined with a cord type. EX: 0463 9. Paint designator needed. 10. Not compatible with WG, VG, or UBV 11. Not compatible with WG, VG, or FV 12. Not compatible with WG, FV, or UBV 13. Not compatible with FV, UBV or VG ACP1LED ACP2LED 25.1 10.6 22.52 10.6 14.02 23.91 18.5 27.9 Effective Projected Area (EPA) The EPA for the ACP1LED is 3.1 sq. ft., Approx. Wt. = 40 lbs. (MVOLT) Knuckle, Approx. Wt. = 47 lbs., (MVOLT) Yoke Effective Projected Area (EPA) The EPA for the ACP1LED is 3.8 sq. ft., Approx. Wt. = 54 lbs. (MVOLT) Knuckle, Approx. Wt. = 65 lbs., (MVOLT) Yoke

Product Overview Optical Performance of the ACP1 is to replace 100-400 watt HID product. Performance of the ACP2 is to replace 400-1000 watt HID product. The luminaire is available in either knuckle mount or yoke mount. The knuckle mount is adjustable and is designed to fit 2.375 inch to 2.875 inch tenons. The yoke mount is available in either painted steel or galvanized steel. The optical system utilizes state-of-the-art chip-on-board technology. The luminaire uses a highly specular internal reflector designed for superior field to beam ratios, uniformity and spacing. NEMA beam pattern choices of 5X5, 6X5, and 6X6 are available. Optional shielding is available to control uplight and light trespass. The optical enclosure is glass. Electrical Long Life: LED light engines are rated > 100,000 hours at 25 C, L70. Electronic driver has a rated life of 100,000 hour at a 25 C ambient. Surge protection device provides IEEE/ANSIc62.41 Category C (10kV/5kA) level of protection. The luminaire comes standard with a 3 stage terminal block that comes prewired eliminating the lineman from opening the unit during installation. The knuckle version is pre-wired to the wiring chamber at the fitter. The yoke mount has provision for a pre-wired cord drop to specified length in the ordering information. The luminaire comes standard with the door frame bolted to the housing. Optional tool-less stainless steel latches are available to allow easy access to LED drivers, surge protection, and terminal block. The optical enclosure is sealed and gasketed to an IP66 rating. Mechanical Rugged die cast aluminum housing is painted with a super durable polyester paint finish for durability and corrosion resistance. Rigorous five stage pre-treating and paint process yields a finish that achieves a scribe creepage rating of 9 after over 2,500 hours exposure to salt fog chamber. Controls The NEMA three pin photocontrol receptacle is standard on all units. An optional five pin receptacle is available. Dimming version (available with DE and VE option) uses proprietary Acuity Brands components to enable continuous 0-10V dimming down to 10% output via the ROAM smart controls system. (sold separately) Photocontrol for solid-state lighting meets ANSI C136.10 criteria. Warranty & Standards UL 1598 A wet location Full warranty terms located at www.acuitybrands.com/ CustomerResources/Terms_and_conditions.aspx