Model Number Structure. Ordering Information. Switch Mode Power Supply S82K (3/7.5/15/30/50/90/100-W Models) Model Number Legend.

Similar documents
S82S (3/7.5-W Models)

S8VE (60/90/120/180/240-W Models)

S82J (10/25/50/100/150/300/600-W Models) CSM_S82J_DS_E_3_1

Switch Mode Power Supply

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Model Number Structure

Model Number Structure

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Model Number Structure

Switch Mode Power Supply

Voltage Current Front-mounting bracket

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

Model Number Structure

NJ-Series Power Supply Unit NJ-PA/PD

Switch Mode Power Supply

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Model Number Structure

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

Switching Frequency Test Conditions (AC3/AC4/AC53-a)

NPN output. 200 mm. Type Cable length Model Remarks

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

Solid State Relays with Failure Detection Function

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4.

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

E2K-X4ME1 2M E2K-X4ME2 2M

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2

Photoelectric Sensor

E2EC. High-sensitivity DC 2-Wire Sensors and Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Model Number Structure

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

Model Number Structure

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Conductive Level Controller

Model Number Structure

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Intelligent Flag Amplifier

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series

Model Number Structure

Handheld Reader Writer

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

EE-SX77/87. Slim, Compact Photomicrosensor that is still easy to use. Photomicrosensor with Slim Cable (Non-modulated) Ordering Information

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Switch Mode Power Supply. New Product

Model Number Structure

Switch Mode Power Supply. New Product

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Switching Power Supply

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

E3S-GS/VS. Both Red-light Models and Greenlight Models to Detect a Wide Variety of Colors. Small Spot/Mark Sensor with Built-in Amplifier

Limit Switch Connectors

Model NPN output PNP output Standard. configuration

Switching Power Supply

M16. Cylindrical 16-dia. Indicator. Indicator (Cylindrical 16-dia.) List of Models. Same basic design as the A16 Pushbutton Switch.

CSM_PYF S/P2RF- -S_DS_E_2_5

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time

Model Number Structure

ID Sensor Modules CJ1W-V600C11/V600C12 CS1W-V600C11/V600C12

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Limit Switch Connectors

Number of input channels

Part number voltage. current Output Undervoltage alarm

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Origin Position Control of an X-Y Table Coaxiality Inspection Checking Turret Indexing Position D5A

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

Model Number Structure

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

Model A7BS

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

Ordering Information. Interface Converter K3SC. List of Models

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

DPDT Basic Switch for Two Independent Circuit Control

G9H. Ordering Information. Hybrid Power Relay. List of Model. Accessories (Order Separately) Connecting Socket Mounting Plate

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

Transcription:

Switch Mode Power Supply (3/7.5/15/30/50/90/100-W Models) CSM DS_E_3_1 Ultimate DIN-rail-mounting Power Supply with a Power Range of 3 to 100 W EMI: EN 61204-3 class B Input: 85 to 264 VAC (except 90-W and 100-W models) Safety standards: UL 60950-1/508, cul: CSA C22.2 No. 14 (Class 2: Per No. 223), cur: CSA No. 60950-1, EN50178 (= VDE 0160) Undervoltage alarm indication available for standard models.] RoHS-compliant! Refer to Safety Precautions for All Power Supplies. Model Number Structure Model Number Legend Note: Not all combinations are possible. Refer to List of Models in Ordering Information, below. - 1 2 3 1. Power Factor Correction None: No P: Yes Ordering Information List of Models 2. Power Ratings 003: 3 W 050: 50 W 007: 7.5 W 090: 90 W 015: 15 W 100: 100 W 030: 30 W 3. Output Voltage 05: +5 VDC 12: +12 VDC 15: +15 VDC 24: +24 VDC 27: ±12 VDC 28: ±15 VDC Note: For details on normal stock models, contact your nearest OMRON representative. Power ratings Output voltage Output current Function Configuration Models Output Undervoltage alarm indicator/output PFC 3 W 5 V 0.6 A Single output Yes No -00305 12 V 0.25 A -00312 15 V 0.2 A -00315 24 V 0.13 A -00324 7.5 W 5 V 1.5 A -00705 12 V 0.6 A -00712 15 V 0.5 A -00715 24 V 0.3 A -00724 ±12 V 0.3 A/0.2 A Dual output -00727 ±15 V 0.2 A/0.2 A -00728 15 W 5 V 2.5 A Single output -01505 12 V 1.2 A -01512 24 V 0.6 A -01524 30 W 5 V 5.0 A -03005 (See note 1.) 12 V 2.5 A -03012 24 V 1.3 A -03024 50 W 24 V 2.1 A -05024 90 W 24 V 3.75 A No -09024 Yes -P09024 100 W 24 V 4.2 A (See note 2.) No -10024 Yes -P10024 Note:1. The output capacity of the -03005 is 25 W. 2. The output current for -P10024 during parallel operation is 3.78 A. 1

Specifications Ratings/Characteristics Power ratings (See note 1.) Single output Dual output Single output Item 3 W 7.5 W 7.5 W 15 W 30 W Efficiency (typical) 60% min. (Varies depending on specifications) 64% min. (Varies depending on specifications) 66% min. (Varies depending on specifications) Input Voltage AC 100 to 240 VAC (85 to 264 VAC) (See note 2.) DC 90 to 350 VDC Not possible Frequency 50/60 Hz (47 to 450 Hz) Current 100-V input 0.15 A max. 0.25 A max. 0.45 A max. 0.9 A max. 200-V input 0.25 A max. 0.6 A max. Power Factor --- Harmonic current emissions --- Leakage current 100-V input 0.5 ma max. 200-V input 1 ma max. Inrush current 100-V input 15 A max. (for cold start at 25 C) 25 A max. (for cold start at 25 C) 200-V input 30 A max. (for cold start at 25 C) 50 A max. (for cold start at 25 C) Noise filter Yes Output (See note 4.) Voltage Adjustment Range ±10% (with V. ADJ) (See note 5.) Not possible (See note 6.) ±10% (with V. ADJ) ( 10% to 15% for -03012/-03024) (See note 5.) Ripple 2% (p-p) max. Input variation influence 0.5% max. (at 85 to 264 VAC input, 100% load) Load variation influence (rated input voltage) Temperature variation influence Startup time 1.5% max. (0 to 100% load) : 1.5% max. 1.5% max. (0 to 100% load) : 3% max. (0 to 100% load) 0.05%/ C max. 100 ms max. (up to 90% of output voltage at rated input and output) Additional functions Undervoltage alarm indication Undervoltage alarm output Parallel operation Operating ambient temperature Storage temperature Other Hold time Overload protection (See note 7.) Overvoltage protection 20 ms min. 105% to 160% of rated load current (105% to 250% of rated load current for dual output models), gradual current/voltage drop, automatic reset (See note 8.) No Yes (color: red) No No Refer to the derating curve in Engineering Data. (with no icing or condensation) 25 to 65 C (with no icing or condensation) Operating ambient humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength Detection current Insulation resistance Vibration resistance Shock resistance Output indicator EMI Conducted Emissions 3.0 kvac for 1 min. (between all inputs and all outputs) 2.0 kvac for 1 min. (between all inputs and PE terminals) 1.0 kvac for 1 min. (between all outputs and PE terminals) 10 ma 20 ma 100 MΩ min. (between all outputs and all inputs, PE terminals) at 500 VDC 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions 300 m/s 2, 3 times each in ±X, ±Y, ±Z directions Yes (color: green) Conforms to EN61204-3 EN55011 Class B and based on FCC Class B Radiated Conforms to EN61204-3 EN55011 Class B Emissions EMS Conforms to EN61204-3 High severity levels Approved standards UL cul cur EN/VDE UL 508 (Listing; Class 2: Per UL1310), Class 2 (excluding Dual Output models), UL60950-1 CSA C22.2 No.14 (Class 2: Per No. 223, excluding Dual output models) CSA No. 60950-1 EN50178 (VDE0160) Based on VDE0160/P100 Weight 150 g max. 260 g max. 380 g max. 105% to 160% of rated load current, gradual current increase, voltage drop intermittent operation, automatic reset Note:1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the power supply may not start. Refer to Overload Protection on page 8 for details. 2. Use with DC voltage input is beyond the conditions of approval or conformance to applicable safety standards. (DC input possible with 15 W max. Use the 7.5-W single-output models under the load of 90% max. if the voltage range is between 90 and 110 VDC. Do not use the Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. There is no polarity. 3. Defined with a 100% load and the rated input voltage (100 or 200 VAC.) 4. The output specification is defined at the power supply output terminals. 5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +10% of the voltage adjustment range. (+15% for -03012/-03024) When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged. 6. The settings for the output voltage must be within the following range: : ±1% of the rated value : ±5% of the rated value 7. Refer to Overload Protection on page 8 for details. 8. When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the protection function will operate at a current of 95% to 160% of the rated load current. 2

Power ratings -P (See note 1.) Single output Item 50 W 90 W 100 W 90 W 100 W Efficiency (typical) 80% min. (Varies depending on specifications) Input Voltage AC 100 to 240 VAC (85 to 264 VAC) 100 V (85 to 132 VAC)/200 V (170 to 264 VAC) Selectable (See note 2.) DC Not possible Frequency 50/60 Hz (47 to 450 Hz) 50/60 Hz (47 to 63 Hz) Current 100-V input 1.3 A max. 2.5 A max. 200-V input 0.8 A max. 1.5 A max. Power Factor --- 0.7 min. (at 200 VAC input, at rated output), 100 V: unlimited Harmonic current emissions --- Conforms to EN6100-3-2 (200-V only) Leakage current 100-V input 0.5 ma max. 200-V input 1 ma max. Inrush current 100-V input 25 A max. (for cold start at 25 C) 200-V input 50 A max. (for cold start at 25 C) Noise filter Yes Output (See note 4.) Additional functions Other Voltage Adjustment Range ±10% (with V. ADJ) ( 10% to 15% for -05024) (See note 5.) ±10% (with V. ADJ) (See note 5.) Ripple Input variation influence Load variation influence (rated input voltage) Temperature variation influence Startup time Hold time Overload protection (See note 6.) Overvoltage protection 2% (p-p) max. 0.5% max. (at 85 to 264 VAC input, 100% load) 1.5% max. (0 to 100% load) 0.05%/ C max. 100 ms max. (up to 90% of output voltage at rated input and output) 20 ms min. 105% to 160% of rated load current, gradual current increase, voltage drop intermittent operation, automatic reset No 0.5% max. (at 85 to 132 VAC input /170 to 264 VAC input, 100% load) 200 ms max. 105% to 160% of rated load current, inverted L drop, automatic reset (See note 7.) Undervoltage alarm indication Yes (color: red) Undervoltage alarm output No Yes Parallel operation No Yes (up to 2 units.) No Yes (up to 2 units.) (See note 8.) Operating ambient temperature Refer to the derating curve in Engineering Data. (with no icing or condensation) Storage temperature 25 to 65 C (with no icing or condensation) Operating ambient humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kvac for 1 min. (between all inputs and all outputs) 2.0 kvac for 1 min. (between all inputs and PE terminals) 1.0 kvac for 1 min. (between all outputs and PE terminals) Detection 20 ma current Insulation resistance 100 MΩ min. (between all outputs and all inputs, PE terminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions Shock resistance 300 m/s 2, 3 times each in ±X, ±Y, ±Z directions 150 m/s 2, 3 times each in ±X, ±Y, ±Z directions Output indicator Yes (color: green) EMI EMS Approved standards Conducted Emissions Radiated Emissions UL cul cur EN/VDE Conforms to EN61204-3 EN55011 Class B and based on FCC Class B Conforms to EN61204-3 EN55011 Class B Conforms to EN61204-3 High severity levels Conforms to EN61204-3 EN55011 Class B and based on FCC Class A UL508 (Listing; Class 2: Per UL1310), Class 2 (excluding dual output models) (See note 9.), UL60950-1 CSA C22.2 No.14 (Class 2: Per No. 223, excluding dual output models) (See note 9.) CSA No. 60950-1 EN50178 (= VDE0160), EN60950-1 (= VDE0805 Teil 1) Based on VDE0106/P100 Weight 400 g max. 600 g max. 1000g max. UL508 (Listing; Class 2: Per UL1310), Class 2 (excluding dual output models) (See note 9.), UL60950-1 CSA C22.2 No.14 (Class 2: Per No. 223, excluding dual output models) (See note 9.) CSA No. 60950-1 EN50178 (= VDE0160), EN60950-1 (= VDE0805 Teil 1) Based on VDE0106/P100 Note: 1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the power supply may not start. Refer to Overload Protection on page 8 for details. 2. Use with DC voltage input is beyond the conditions of approval or conformance to applicable safety standards. Do not use the Inverter output for the Power supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. There is no polarity. 3. Defined with a 100% load and the rated input voltage (100 or 200 VAC.) 4. The output specification is defined at the power output terminals. 5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +10% of the voltage adjustment range. (+15% for -03012/-03024) When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged. 6. Refer to Overload Protection on page 8 for details. 7. When using the 90-W model at an ambient temperature of 25 C or less, the overload protection function will operate at 101% to 111% of the rated output current. When using the 90-W model at an ambient temperature exceeding 25 C, the overload protection function will operate at 92% to 111% of the rated output current. 8. Parallel operation is set with the Parallel/Single Operation Selector. 9. To meet Class-2 requirements with the 100-W, either a fuse or breaker that is UL listed or CSA certified, and rated at 4.2 A max. should be wired in series with the load to be connected to the Power Supply. Only then can the Power Supply output be considered as meeting Class 2. 3

Connections Block Diagrams -003@@ (3 W) -007@@ (7.5 W, Single Output) AC (L) Fuse (1 A) + V Noise filter AC (N) Inrush current protection V Drive control Undervoltage alarm indicator Overload detection Photocoupler Detection -007@@ (7.5 W, Dual Outputs) AC (L) Fuse (1 A) V Noise filter AC (N) Inrush current protection 3-terminal REG + V Drive control Undervoltage alarm indicator Overload detection Photocoupler Detection -015@@ (15 W) -030@@ (30 W) -05024 (50 W) AC (L) Fuse (3 A) + V Noise filter AC (N) Inrush current protection V Drive control Undervoltage alarm indicator Overload detection Photocoupler Detection 4

-09024 (90 W) -10024 (100 W) AC (L) Fuse (5 A) + V Noise filter AC (N) 100 or 200 V Selectable terminals (See note.) Inrush current protection Drive control Undervoltage alarm indicator/output V Overload detection Photocoupler Detection Note: Use the short bar to short- terminals 7 and 8 to select 100 to 120 VAC and remove the short bar to select 200 to 240 VAC. -P09024 (90 W) -P10024 (100 W) AC (L) Fuse (5 A) Noise filter Harmonic current emission control (By-passed for 100-V input) + V AC (N) 100 or 200 V Selectable terminals (See note.) Inrush current protection Drive control Undervoltage alarm indicator/output V Overload detection Photocoupler Detection Note: Use the short bar to short- terminals 7 and 8 to select 100 to 120 VAC and remove the short bar to select 200 to 240 VAC. 5

Construction and Nomenclature Nomenclature -003@@ -007@@ (Single Output) 1-007@@ (Dual outputs) 1 1-015@@ 1 5 7 6 5 7 5 7 6 2 3 2 3 2 3-030@@ -05024 1 8 -@09024 -@10024 1 5 7 6 5 7 6 2 3 2 3 4 Parallel/Single Operation Selector (Only for - P10024) 1. DC Output Terminals ( and ): Connect the load lines to these terminals. 2. AC Input Terminals (L and N): Connect the input lines to these terminals. 3. Protective Earthing Terminals (PE): Connect a ground line to these terminals. 4. Input Voltage Selector Terminals (VOLTAGE SELECT): Selects a 100 V or 200 V input voltage. 5. Output Indicator (DC ON: Green): Lights while a Direct Current (DC) output is ON. 6. Output Voltage Adjuster(V.ADJ): Use to adjust the voltage. 7. Undervoltage Alarm Indicator Terminal (DC LOW: Red): Lights when there is a drop in the output voltage. 8. Undervoltage Alarm Output Terminals (DC LOW): -@09024/-@10024 only. 9. Parallel/Single Operation Selector: Set to "PARALLEL" for parallel operation. 9 6

Engineering Data Derating Curve (A: Standard mounting, B: Face-up mounting) 3-/7.5-/15-/30-/50-/100-W 100-W Models without PFC 100-W Models with PFC Models (-10024) (-P10024) Single-Unit Operation Parallel Operation Parallel Operation Load (%) Installation B Installation A Load (%) Installation A 65 -P10024: 65 85-VAC input -03005 Installation A Installation B Load (%) 90 -P10024: 85-VAC input Installation B Installation A Ambient temperature ( C) Note: When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the load rate will become 90% or less. 90-W Models Single-Unit Operation Ambient temperature ( C) Ambient temperature ( C) Load (%) -P09024: 85-VAC input 65 Installation A Installation B Ambient temperature ( C) Note: 1. The derating curve may vary depending on the installation conditions. 2. Multiple units cannot be installed in a configuration where they are lined up vertically. 3. Use the 7.5-W single-output models under the load of 90% max. if the voltage range is between 90 and 110 VDC. 4. The cold-start time will be longer when using -P09024 or -P10024 with an 85-VAC input. Mounting Top Top Note: Installations other than (A) and (B) are not possible. (A) Standard mounting (B) Face-up mounting 7

Overload Protection The Power Supply is provided with an overload protection function that protects the Power Supply from possible damage by overcurrent. When the output current rises above 105% min. of the rated current, the protection function is triggered, automatically decreasing the output voltage. When the output current falls within the rated range, the overload protection function is automatically cleared. 3-/7.5/15 W Models 30-/50 W Models 90-/100 W Models Output voltage (V) Output voltage (V) Output voltage (V) Intermittent operation 0 50 100 Output current (%) 0 50 100 Output current (%) The values shown in the above diagrams are for reference only. 0 50 100 Output current (%) Note: 1. When connecting a load that has a built-in DC-DC converter, the overload protection function may operate during startup, thus preventing the Power Supply from starting. 2. Internal parts may occasionally deteriorate or be damaged if a short-ed or other overcurrent state continues during operation. 3. When using the 7.5-W single-output models at the input voltage range of 90 to 110 VDC, the overload protection function will operate at 95% to 160% of the rated output current. 4. When using the 90-W model at an ambient temperature of 25 C or less, the overload protection function will operate at 101% to 111% of the rated output current. When using the 90-W model at an ambient temperature exceeding 25 C, the overload protection function will operate at 92% to 111% of the rated output current. 5. When using the 100-W model with PFC in parallel operation, operation is limited to a load ratio of 90% to 100% of the rated output current at 4.2 A. When Using ± Output Models The output detects the total output power ( output and output) to trigger the short- protection against overcurrent. This protection varies depending on the output state. The output independently triggers the short- protection. Undervoltage Alarm Indicator and Output Function If the output voltage at the output terminal drops to 75% to 90% of the rated voltage, the red indicator of the will be lit. In the case of the -@09024/@10024, a voltage drop alarm will be output via the relay available in the models. Note: This function detects the voltage at the output terminal of the Power Supply. To check the precise output voltage, measure the voltage at the terminal of the load. Green lit: Red not lit: Green lit: Red lit: Green not lit: DC ON Red not lit: Indicator Voltage Operation of @09024/@10024 s output (See note 2.) DC ON If the voltage at the output terminal is more than 82% of the rated voltage and operation is normal, the green indicator DC LOW DC ON will be lit and the red indicator will not be lit. If the voltage at the output terminal drops to below 82% (See note 1.) of the rated voltage, the red indicator will be lit. (See DC LOW note 3.) If the voltage at the output terminal approaches 0 V, both the green and red indicators will not be lit. DC LOW Note: 1. The more the voltage at the output terminal drops, the darker both the green and red indicators will be. 2. The relay contacts have a capacity of 0.1 A at 24 VDC. 3. The red indicator will actually first light at a voltage between 75% and 90% of the rated voltage at output terminal. 8

Inrush Current, Startup Time, Hold Time Input ON Input OFF AC input voltage Inrush current on input application AC input current 90% 96.5% Output voltage Startup time: 100 to 1000 ms max. depending on the model. Hold time (20 ms min.) Reference Value Item Value Definition Reliability (MTBF) 135,000 hrs min. MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates reliability of devices. Therefore, it does not necessarily represent a life of the product. Life expectancy 8 yrs. min. The life expectancy indicates average operating hours under the ambient temperature of 40 C and a load rate of 50%. Normally this is determined by the life expectancy of the builtin aluminum electrolytic capacitor. 9

Dimensions Note: All units are in millimeters unless otherwise indicated. -003@@ (3 W) -007@@ (7.5 W) Mounting Brackets (Supplied) Used when not mounting the Power Supply directly on the DIN rail. Two, 4.5±0.1 dia. 35±0.15 25±0.15 27±0.1 37.5±0.1 (Sliding: 7 max.) M3.5 with square washer Mounting Holes Attached Mounting Bracket M4 or 4.5-dia. hole Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. -015@@ (15 W) 45 9.8 8.3 7.5 Mounting Holes Two, M4 or 4.5-dia. mounting holes 75 58.1 45 35 60 4.6 (Sliding: 7 max.) M3.5 with square washer 91 5 L 35 Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. 10

-030@@ (30 W) -05024 (50 W) Four, 4.5 dia. 35 4 (Sliding: 7 max.) M3.5 with square washer Mounting Holes Four, M4 or 4.5-dia. mounting holes 60 Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. L 80 -@09024 (90 W) -@10024 (100 W) 145 9.8 135±0.2 8.3 Four, 4.5 dia. 7.5 75 58.1 60±0.2 45 35 4 (Sliding: 7 max.) M3.5 with square washer M3.5 terminal screw Short bar 91 5 Mounting Holes Four, M4 or 4.5-dia. mounting holes 60 Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. L 135 11

DIN Rail (Order Separately) Mounting Rail (Material: Aluminum) PFP-100N/PFP-50N PFP-100N2 4.5 15 25 25 25 25 10 1,000 (500) 10 (See note.) 7.3±0.15 35±0.3 27±0.15 15 (5) (See note.) Note: The values shown in parentheses are for the PFP-50N. Noise Filter (Order Separately) 1 4.5 15 25 25 25 25 15 10 10 1,000 35±0.3 16 27 24 29.2 1 1.5 S82Y-JF3-N for 3- to 50-W Models S82Y-JF6-N for 90- and 100-W Models 4 16 max. Two, 4.8 dia. A max. 16 max. (Mounting B±1 holes) D±1 39±0.5 Nameplate 47±1 4 6.5 C±0.5 6.5 Six, M4 12

Safety Precautions Refer to Safety Precautions for All Power Supplies.!CAUTION To dismount the Power Supply, pull down portion (C) with a flat-blade screwdriver and pull out the Power Supply. Minor electric shock, fire, or Product failure may occasionally occur. Do not disassemble, modify, or repair the Product or touch the interior of the Product. Minor burns may occasionally occur. Do not touch the Product while power is being supplied or immediately after power is turned OFF. Fire may occasionally occur. Tighten terminal screws to the specified torque of 0.98 N m (M3.5). Minor injury due to electric shock may occasionally occur. Do not touch the terminals while power is being supplied. Always close the terminal cover after wiring. Minor electric shock, fire, or Product failure may occasionally occur. Do not allow any pieces of metal or conductors or any clippings or cuttings resulting from installation work to enter the Product. Precautions for Safe Use Mounting Take adequate measures to ensure proper heat dissipation to increase the long-term reliability of the product. The Power Supply is designed to radiate heat by means of natural air-flow. Therefore, mount the Power Supply so that air flow takes place around the Power Supply. Wiring Do not apply more than 75-N force to the terminal block when tightening it. Ensure that input and output terminals are wired correctly. Selection of 100 or 200 VAC Input Voltage (-@09024/-@10024) (C) Rail stopper 30 mm min. Select a 100-V or 200-V input by shorting or opening the input voltage selector terminals, as shown in the following diagram. (The default setting is 200 V.) 100-V Input Air When mounting two or more Power Supplies side-by-side, allow at least 10 mm spacing between them, as shown in the following illustration. Forced air-cooling is recommended. Use the short bar to short- terminals 7 and 8. 200-V Input 10 mm min. Remove the short bar to open terminals 7 and 8. Generating Output Voltage (±) Short bar To mount the Power Supply on a DIN rail, hook portion (A) of the Power Supply to the rail and press the Power Supply toward direction (B). An output of ± can be generated by using two Power Supplies as shown below, because the Power Supply produces a floating output. Correct (A) (B) When connecting the Power Supplies in series with an operation amplifier, connect diodes to the output terminals as shown by the dotted lines in the figure. No diodes are required with -@09024 and -@10024. 13

Series Operation Two Power Supplies can be operated in series. Only 90-W/100-W models can be operated in series. Series operation, however, is not possible for the + outputs and outputs of models with ± outputs. Correct 90-, 100-W Models Parallel Operation 100-W models can be operated in parallel. Perform parallel operation with power supplies satisfying the same model. Correct 100-W Models Incorrect 3-, 7.5-, 15-, 30-, 50-W Models Note: When operating the -P10024 in parallel operation, set the selector to PARALLEL. In this case, the rated current per -P10024 is 3.78 A. Incorrect 3-, 7.5-, 15-, 30-, 50- and 90-W Models Parallel Operation Precautions The length and thickness of each wire connected to the load must be the same so that there is no difference in voltage drop value between the load and the output terminals of each Power Supply. Adjust the output voltage of each Power Supply with output voltage adjuster (V. ADJ) so that there will be no difference in output voltage between each Power Supply. Minimum Output Current (-00727/-00728) The minimum output current of the -00727 and -00728 is restricted by the output voltage and control method. Note: All the outputs of the -00727 and -00728 are controlled by the output. If the output current falls to more than 10% of the rated output, the V output voltage may drop. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 14

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2011.1 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2011 All Right Reserved.