Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

TS InteliSwitch Digital Time Switch 24VDC/VAC

Installation Instructions

Installation Instructions

FSIR-100. User Guide. Wireless IR Commissioning Tool CONTENTS USING THE FSIR-100 COMMISSIONING TOOL BATTERIES

Self-Adjusting Ultrasonic Wall Switch Sensor

For Models #2384W/I (and Slave Remote Dimmer Model #1135W/I)

Installation Instructions

Micro Smart Dimmer 2E manual. In-Wall Electrical Installation Instructions:

INSTEON KeypadLinc TM Dimmer (Rev 1.5+) INSTEON Keypad Dimmer. For models: KeypadLinc Dimmer 8-Button

Mini Recessed PIR. Model: PDFM360MINI. Installation & Operating Instructions

INSTEON SwitchLinc 1000W. INSTEON Dimmer Switch. For models: SwitchLinc V2 Dimmer 1000W

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

Bluetooth Ceiling Fan Control with App Owner's Manual

2400W PIR Light Controller

2x 10W LED Slimline PIR Floodlight Twin Flood

Before you get started

Octostrip ORDERCODE 42220

GETTING STARTED WITH IN-WALL RELAY SWITCH

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Pulse LED Instruction Guide

* Optional TLPC shown. Mounting for Square Pole ORDERING INFORMATION 72W 108W 141W 188W 108LED 141LED 188LED. DM 0-10V Dimming. (Std.

INSTALLATION INSTRUCTIONS

1 Channel Strobe Controller ORDERCODE 40226

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

E1135C PDU and Pod Upgrade Procedure

Power Load Controller F series INSTALLATION GUIDE

Sapling Converter Box

Maestro Occupancy sensing switch

Lighting PowerPincher Installation Instructions

Installation, Start-up and Operating Instructions

Wireless Lighting Control Duplex Receptacle

Installation Instructions

Telephone Switch Module. Model# TSM-1. User Guide. Santa Clara, CA (800) (972)

HIGH BAY PASSIVE INFRARED OCCUPANCY SENSOR

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443

Maestro Occupancy Sensing Switch

LITETOUCH HYBRID WALL BOX DIMMER INSTALLATION INSTRUCTIONS

INSTEON ToggleLinc. INSTEON Dimmer Switch. For models:

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

Wattstopper. No: /17 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

Progressive Industries, Inc. EMS Electrical Management System

LA600WH WIRED / WIRELESS DOOR CHIME

Large Police Light 100W ORDERCODE 80361

LED Gooseneck light FEATURES AND BENEFITS: ORDERING MATRIX: LED GOOSENECK LIGHT:

ETC Installation Guide

CDD Carbon Dioxide Transmitter

Data sheet. Function description. Benefits

H704-42(H)(E), H704-42/1(H)(E)

TO AVOID FIRE, SHOCK, OR DEATH; SHUT OFF POWER SUPPLY AT THE CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING.

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

Power Supply and Fan Module Installation

AuroRa Security Installation Guide

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

HAIKU WALL CONTROL KIT

Z-Wave Certified Wireless Lighting Control. Auxiliary Switch ZW2001 ZW2002 rev. 09/01/11

Elapsed Timer Control Panel

Broadband Automatic Disconnect Switch. User Manual

DALI Professional Controller-4. Control unit Operating instructions

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Control Box Setup - PRSalpha

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

Kuna Installation Guide

Specifications N Termination Voltage Range Current Consumption, Max. Type Number Termination. Voltage Range. Sinking Sensor Current

THE CTB08D LIGHT CONTOLLER

PRODUCT DESCRIPTION PACKAGE CONTENTS

Tempco Instruction Manual

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

LSXR50 Sensor. Features pallet quantity. Descriptions

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

Control Your World. Lighting Control System

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

OWNER'S MANUAL DIMMERMASTER 1224 DIGITAL DIMMER

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

HOBO Occupancy/Light Data Logger (UX90-005x/-006x) Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

PRODUCT MANUAL Duet DMX & Wireless RGB-W Controller

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Owner's Manual. Carrier TOSH BA REMOTE CONTROLLER FOR AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit TCB-AX21 UL

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

PowerLogic High Density Metering System 1-Meter Enclosure

SK Installation Instructions

Standalone combined PIR camera with RF transmitter

CONTROLLER INSTALLATION OPERATION & QUICK START

Replacing the Power Supply

Operating instructions. Speed monitor D / / 2014

IIM Warwick Court. Williamsburg VA REV 5

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

EMS Electrical Management System

Transcription:

Please read all instructions before installing RS-350 PIR Dual Relay Universal Application Wall Switch Vacancy Sensor with Manual ON/OFF Lens Lighted Switch ON/OFF button for Relay 1 ON/OFF button for Relay 2 SPECIFICATIONS Voltage...120VAC, 60Hz Load (Single Pole Circuit, each relay) Incandescent or fluorescent... 0-600 Watts Fan motor... 1/6 hp Time Delay Adjustment...15 seconds to 30 minutes Light Level Adjustment...10 fc to 150 fc Environment...Residential Indoor use only Operating Temperature... 32 to 131 F (0 to 55 C) Humidity... 95% RH, non-condensing Tools Needed Insulated Screwdriver Wire Strippers Santa Clara, CA 95050 Installation Instructions DESCRIPTION AND OPERATION The RS-350 PIR Dual Relay Universal Application Wall Switch Vacancy Sensor is designed to replace two single pole standard residential switches or one combination switch ( double switch ). It is ideal for living and dining rooms, family rooms, bedrooms, bathrooms and any other indoor area in a residential space where occupancy sensor-based manual ON/OFF control of two different loads (i.e., a lamp and a fan) from a single location is desirable. Like a standard combination switch, you press either or both of the two ON/OFF buttons to turn lights and/or fans (controlled loads) ON and OFF. Unlike a standard combination switch, the RS-350 automatically turns OFF the controlled loads after the coverage area has been vacant for a period of time (Time Delay). If motion is detected within 30 seconds after they automatically turn OFF, the RS-350 automatically turns the loads back ON. While the sensor is factory preset as a Vacancy Sensor with manual-on operation, it can be adjusted to work as an Occupancy Sensor that turns the controlled loads ON automatically upon detection of occupancy in the area. Lighted Switch To help you locate the RS-350 in a dark room, an amber LED illuminates each of the ON/OFF buttons while the controlled loads are OFF. When one of the controlled loads is ON, the corresponding LED is OFF. Operating Modes There are two operating modes that can be selected independently for each relay during set up: MODE 1 Vacancy sensor (Manual-ON/OFF, Auto-OFF): The user must press the ON/OFF button to turn the load ON. The RS-350 keeps the load ON until no motion is detected for the selected time delay period (adjustable from 15 seconds to 30 minutes). There is a 30 second reset delay. If motion is detected during this time, the sensor turns the load back on automatically. After the reset delay time has elapsed, the ON/OFF button must be pressed to turn ON the load. MODE 2 Occupancy sensor (Auto-ON/OFF with manual control and reset to auto after 5 minutes of vacancy): The load turns ON and OFF automatically based on occupancy detection. The RS-350 keeps the load ON until no motion is detected for the selected time delay period. If the load is turned OFF manually, automatic- ON is re-enabled when no motion is detected for 5 minutes. This prevents the load from being turned ON after it was deliberately turned OFF. Call 888.817.0571 for Technical Support

Time Delay The time delay can be selected by the user during set up. It can be adjusted from 15 seconds up to 30 minutes and it applies to both relays (hence to both controlled loads) simultaneously. For additional information on how to adjust the time delay, please read the SENSOR ADJUSTMENT & PROGRAMMING section of this installation manual. Light Level (Relay #1 only) When relay #1 is set for occupancy sensor Mode 2 (Auto-ON/OFF) the light level feature prevents the sensor from automatically turning the lights, controlled by relay #1, ON if there is already enough light in the area. To adjust the light level, please read the SENSOR ADJUSTMENT & PROGRAMMING section of this installation manual. Coverage Area The RS-350 has a maximum range of 180 degrees and a coverage area of 600 sq. feet (56 sq. meters). The sensor must have a clear and unobstructed view of the coverage area. Objects blocking the sensor s lens may prevent detection thereby causing the load (or loads) to turn OFF even though someone is in the area. 25' (7.6m) 12' (3.7m) Fig. 1: Sensor Coverage Area Windows, glass doors, and other transparent barriers will obstruct the sensor s view and prevent detection. INSTALLATION & WIRING WARNING Disconnect power to the wall switch box by turning OFF the circuit breaker or removing the fuse for the circuit before installing the RS-350, replacing lamps, or doing any electrical work. 1. Prepare the switch box. After the power is turned OFF at the circuit breaker box, remove the existing wall plate and mounting screws. Pull the two old switches or combination switch (double switch) out from the wall box. 2. Identify the type of circuit. If you are replacing a combination switch, you may find either circuit A or B: A. Single-circuit wiring (see Fig. 2): Three wires are attached to the combination switch. The HOT feed wire bringing power into the box is connected to the side of the switch that has a connecting tab. The wires carrying power out to the loads are connected to the side of the switch that does not have a connecting tab. A neutral wire should be present in the wall box. A ground wire may also be present and connected to a ground terminal on the old switch. TO LOADS GROUND FEED WIRE Fig. 2: A. Single-circuit wiring NEUTRAL www.wattstopper.com/athome

B. Separate-circuit wiring (see Fig. 3): Four black wires are attached to the combination switch. HOT feed wires from the power source are attached to the side of switch that has a connecting tab, and the connecting tab is removed. Wires carrying power from the switch to loads are connected to the side of the switch that does not have a connecting tab. A neutral wire should be present in the wall box. A ground wire may also be present and connected to a ground terminal on the old switch. If you are substituting two single pole switches, each single pole circuit should match the following description: In a Single Pole Circuit (see Fig. 4), two single wires connect to two screws on the existing switch. A ground wire may also be present and connected to a ground terminal on the old switch. A neutral wire should also be present in the wall box. FEED TO LOADS GROUND Fig. 3: B. Separate-circuit wiring Ground HOT (power from circuit box) NEUTRAL LOAD (power to lamp) NEUTRAL Fig. 4: Typical Single Pole Switch Wiring CAUTION - FOR YOUR SAFETY: Connecting a proper ground to the sensor provides protection against electrical shock in the event of certain fault conditions. If a proper ground is not available, consult with a qualified electrician before continuing installation. Only connect the RS-350 to one of the three circuit options described. The RS-350 is not suitable for 3-way switching. If the existing wiring does not match any of the previously described circuit options, you should consult with a qualified electrician. 3. Prepare the Wires. Tag the wires connected to the existing switch, so that they can be identified later. Disconnect the wires. Make sure the insulation is stripped off the wires to expose their copper cores to the length indicated by the Strip Gage in Fig. 5 (approx. 1/2 inch). Strip Gage 1/2" 12.7 mm Fig. 5: Wire Stripping 4. Wire the sensor.* Twist the existing wires together with the wire leads on the RS-350 sensor as indicated below. Cap them securely using the wire nuts provided (See Fig 6). Brown/White ->LOAD #2 (switched power to load #2) Brown ->HOT #2 (power from circuit box for load #2) White -> NEUTRAL TOP INDOOR USE ONLY Black ->HOT #1 (power from circuit box for load #1) Red ->LOAD #1 (switched power to load #1) Green ->GROUND Terminal Fig. 6: Sensor orientation, wire connections and wall box assembly * These instructions assume wiring the RS-350 to two independent feed wires (HOTs). If you only have one HOT feed wire coming into the wiring box, connect it to both the solid Brown and solid Black wires on the RS-350.

06006r1 Connect the green or non-isolated (copper) GROUND wire from the circuit to the RS-350 green terminal. Connect the NEUTRAL wire from the circuit and from the loads to the white wire on the RS-350. Connect the power wire from circuit #1 (HOT#1) to the black wire on the RS-350. Connect the power wire to load #1 (LOAD#1) to the red wire on the RS-350. Connect the power wire from circuit #2 (HOT#2) to the solid brown wire on the RS-350. Connect the power wire to load #2 (LOAD#2) to the striped brown/white wire on the RS-350. 5. Put the RS-350 in the wall box. Position the lens above the ON/OFF buttons (lens at top, buttons at bottom) and secure it to the wall box with the screws provided. 6. Restore power to the circuit. Turn ON the breaker or replace the fuse. 7. Test the sensor s operation. See TEST MODE. 8. Review SENSOR ADJUSTMENT & PROGRAMMING below. If you want to make adjustments, follow the instructions in the SENSOR ADJUSTMENT & PROGRAMMING section. 9. Attach the new cover plate. Secure it to the wall box with the screws provided SENSOR ADJUSTMENT & PROGRAMMING To program the RS-350, you use controls located under the ON/OFF buttons. The wall switch cover plate must be removed to gain access to the mode button and adjustment trimpots under the ON/OFF buttons. 1. Firmly grasp the side edges of the Lock Bar and gently pull it away from the switch face until it clicks. Do NOT attempt to pull the Lock Bar off of the switch! 2. Firmly grasp the outside edges of the ON/OFF buttons. Slide the buttons downward approximately 1/2 inch to expose the mode button and adjustment trimpots. max Light Level TOP min 30 Min. 15 Sec. Mode 1 Manual 15 2 Auto-ON minutes Time Delay INDOOR USE ON LY Lock Bar Mode Button & Adjustment Trimpots Slide down ON/OFF Buttons Setting up the Operating Mode Fig. 7: Sensor Adjustment Controls Select the operating mode for each relay by pressing the Mode button. The amber LED behind each of the switch buttons blinks to indicate the selected mode for that particular associated relay: One blink indicates Mode 1 (Vacancy Sensor Operation), Manual-ON/OFF, Auto-OFF Two blinks indicate Mode 2 (Occupancy Sensor Operation), Auto-ON/OFF w/manual control and reset to auto (after 5 minutes of vacancy) To change the mode, press the Mode button once to set the unit to mode 1 or press the Mode button twice to set the unit to mode 2. The LED blinks to indicate the selected mode. It repeats the selected mode three times. After that, the unit operates in the indicated mode. Call 888.817.0571 for Technical Support

Below are the possible mode logic combinations that can be selected by pressing the Mode button: Logic LED #1 blinks Relay #1 LED #2 blinks Relay #2 Combination 1 Once Manual Once Manual Combination 2 Twice Auto-ON Once Manual Combination 3 Once Manual Twice Auto-ON Combination 4 Twice Auto-ON Twice Auto-ON Adjusting the Time Delay Turn the right trimpot counter-clockwise to reduce the amount of time both loads will remain on after the last motion detection (minimum = 15 seconds). Turn the same trimpot clockwise to increase this time delay (maximum = 30 minutes). Warning: Do not overturn the time delay adjustment trimpot! Adjusting the Light Level (Feature applicable to relay #1 only) This feature, applicable only to relay # 1, is factory set at maximum, so that even the brightest light will not prevent the sensor from turning the load, connected to the relay # 1, ON when it detects occupancy. If this feature is not needed, leave the light level at maximum, fully clockwise. 1. The light level must be adjusted when lights would normally be turned OFF because there is enough natural illumination. 2. Set the sensor to Mode 2 and reduce the time delay to 15 seconds. 3. Adjust the light level to minimum. Let the sensor time out so lights connected to the relay #1 are OFF and then wait 30 seconds more. 4. Without casting a shadow on the sensor, enter the area. The lights connected to the relay #1 should remain OFF. 5. Adjust the light level trimpot clockwise in small increments. Wait 5-10 seconds after each adjustment to see if the lights connected to relay #1 turn ON. Continue this procedure until the lights connected to relay #1 turn ON. At this setting the lights connected to relay #1 will not turn ON automatically with occupancy if the light level is above the current natural illumination. 6. Reset the time delay to the desired setting. Warning: Do not overturn the light level adjustment trimpot! TEST MODE During the TEST mode, the controlled loads turns ON for 5 seconds each time the sensor detects occupancy. To test the detection coverage: 1. Press and hold any of the ON/OFF buttons. After 10 seconds the lighted switches flash. The loads turn ON if they were not already ON. The sensor is now in a TEST mode that lasts 5 minutes. (You can end the TEST mode sooner by pressing the same ON/OFF button for another 10 seconds). 2. Move out of the coverage area or stand very still. The controlled loads turn OFF after 5 seconds if no motion is detected. 3. Move into the coverage area. The controlled loads turn ON for 5 seconds each time the sensor detects motion. After 5 seconds expire without motion detection, the loads turn OFF. The controlled loads turn ON automatically with the next motion detection and stay on for 5 seconds. 4. Repeat as necessary to ensure that the desired coverage areas are within detection range. www.wattstopper.com/athome

TROUBLESHOOTING Lighted switches are OFF, no load response when pressing any of the ON/OFF buttons: Make certain that the circuit breaker is on and functioning. Lighted switches are ON, no load response when pressing any of the ON/OFF buttons: Check the loads connected to the sensor (i.e. light bulbs and/or the motor switch on the fan mechanisms). Load will not turn ON automatically when the area is occupied and the corresponding sensor relay is in Mode 2 (the associated lighted switch is ON): If you are troubleshooting the load connected to relay #1, press ON/OFF button #1. If the load turns ON, check the light level setting and also make sure the sensor lens is not blocked. The light level can prevent the sensor s relay #1 from turning on the load automatically. If none of the loads connected to relay #1 or relay #2 turn ON when you press the associated ON/OFF button, check each of the loads connected to the sensor (i.e., light bulbs and/or the motor switch on the fan mechanism). The loads will not turn OFF automatically: Press each of the ON/OFF buttons. If the controlled loads turn OFF, go to next step. The time delay can be set from 30 seconds to 30 minutes. The time delay applies to both sensor relays. Ensure that there is no movement within the sensor s view for the set time period. Hot air currents and heat radiant devices can cause false detection. Make sure the sensor is at least 6 feet (2 meters) away from devices that are a significant heat source (e.g., heater, heater vent, high wattage light bulb). If load does not respond properly after following troubleshooting, turn OFF power to the circuit then check wire connections or call technical support. WARRANTY INFORMATION Watt Stopper/Legrand warranties its products to be free of defects in materials and workmanship for a period of five (5) years. There are no obligations or liabilities on the part of Watt Stopper/Legrand for consequential damages arising out of, or in connection with, the use or performance of this product or other indirect damages with respect to loss of property, revenue or profit, or cost of removal, installation or reinstallation. 2800 De La Cruz Boulevard, Santa Clara, CA 95050 Technical Support: 888.817.0571 www.wattstopper.com/athome 07985r2 4/2009