Installation Guide for Multidrop Combi with Valve Driver for Polara RS

Similar documents
Customer Support Guide Creating a custom Headcount Dashboard

Report Viewer Tutorial

How To: Querying a Database in Excel

USB to Serial Cable Hardware and USB Driver Installation instructions

ClonePix TM 2 QUICK SET-UP INTRUCTIONS MANUAL SOFTWARE RELEASE

Kulite DAQ. Data Acquisition Software User s Manual. Version 3.2.0

Communication Setup Tool for SRZ Series Digital Controller (Win UCI-SRZ)

sohodox Quick Start Guide

Attaching Codesoft 6 to an ODBC Database

User manual. EnVision. Software version 1.12

GloMax 96 Microplate Luminometer

User Manual. Thermo Scientific Orion

StakMax Plate Handling System. User Guide

GloMax 96 Microplate Luminometer INSTRUCTIONS FOR USE OF PRODUCTS E6501, E6511, E6521.

ClonePix TM FL Quick Set-Up Instructions

FlowAccess TM GETTING STARTED. Windows software for Skalar SAN plus systems. Version and up

Liquid handling with modular dosing system

Windows XP Software Installation Instructions GCC Elite Series Printers

Budget Reports for All Users

English. For Windows. WebAccess. User Manual. Buffalo Inc.

Dot Matrix Indicator Programming

Warranty. Disclaimer. Revised January 29 th,

Contents. Installing the Driver...4. Motic Images Plus 2.0 ML Precise Calibration Capturing Images and Video...18

6.3. Applying Designs CHAPTER

Product Overview. your solutions

Issued by: LABORATORY MANAGER Original Date: March 14, 2001 Approved by: Laboratory Director Revision Date: June 6, 2003.

Software Manual Part II: Control Software. Version 5.10

SPA III Quick Reference Guide for Custom Panels

SAM Animation: Troubleshooting

GSC400 Series. GSC400 Programmer and PC Interface User Manual

PerkinElmer Series 200 HPLC: Operating Procedure

PM4 + Partners Knowledge Articles

Nonin Medical, Inc st Avenue North Plymouth, Minnesota USA

Release Notes. Bio-Plex Manager Software, Version 5.0 October 18, 2007

RS 422/485 ComProbe. Quick Start Guide

U-20 Data Collection Software (U-20 for Win-XP/E) Operation Manual

Client Configuration Guide

SymBiot I Sample Workstation

Tenmast Quick Start Guide

Olympus Recorder Basics:

DATA ACQUISITION Hints and Tips

AdminTools. Quick Start Guide. Software for instruments and devices. JSC "Energomera"

SAFARI General Instructions

Irrigation Control. Quick Start Guide Version 2c. Using Soil Moisture Sensors. Delta-T Devices Ltd

Creating and Running a Report

Create a unit using United Streaming and PowerPoint. Materials: Microsoft PowerPoint, Internet access, United Streaming account

Access 2010 Lesson 4 - Managing Database and Objects

The Olis Titrator Series

Working with Standards and Duplicates in Geochemistry for ArcGIS

MICROSOFT VISIO 2010

Setting up the Data Source Creating a Report Design Creating a Report Definition Adding it to the Queue Processing the Report

USB SERIAL ADAPTOR COM PORT INSTRUCTIONS

D&B Market Insight Release Notes. November, 2015

User s Guide. PC Tool for a Universal Bulk Ink System

fluidhandling 96 and 384 channel liquid handling Reagent dispensing Non-contact acoustic dispensing Accessories and consumables

Tecan Cavro components overview. Tecan Cavro innovation is everywhere

epact2 Hospital Trust / Provider Quick start guide

Starting Visual Studio 2005

Uno International Ltd. 20 Belsize Avenue London NW3 4AU/England Co Reg No VAT No Stepper Control Board Manual ISS 8 June 2013

MX-5070/6070. Envelopes Hard Stock Glossy Paper Labels etc. (2,100 sheets only Letter) Capacity Cassette. Document Feeder (150 sheets)

Instruction Manual HIOKI Standby Power Measurement Software

Version 3.1. For the Odyssey Classic Infrared Imaging System

Instructions for Installing FlashUpdate and Downloading Updates for Super Buddy Satellite Meter

PRODUCTIVITY TIPS USING OUTLOOK Washtenaw Community College

Toolkit Activity Installation and Registration

Relativity. User s Guide. Contents are the exclusive property of Municipal Software, Inc. Copyright All Rights Reserved.

G.S.I Controller Web Application. Administrator Guide

Tecan Cavro components overview TECAN CAVRO INNOVATION IS EVERYWHERE

Version 4.0. Quick Start Guide For the Odyssey CLx Infrared Imaging System

2 Your printer. To get up and running with your. EPSON Stylus COLOR 850, you ll need to: Set up the printer

Technical Bulletin DS2

Precision Instruments for Research and Industry. J-KEM Scientific Syringe Pump

Working Model Tutorial for Slider Crank

All About PlexSet Technology Data Analysis in nsolver Software

Introduction In this document, users will Llearn how to utilize SysQue Systems Pipe, and how to draw Pipe into their projects.

1. What s New in Bio-Plex Manager 6.1

Getting started with Panopto Instructors

2.02.x Summary of Firmware Release

DSX Automated ELISA System

ODBC Connector. Using the ODBC Connector. Download Drivers. Configure Your Ciiva Client. Modified by Phil Loughhead on 17-Feb-2016

Unpack the machine and its components. Cassette/Multi-purpose tray

INVU SERVICES LTD GETTING STARTED GUIDE FOR SERIES 6

USB SERIAL ADAPTOR COM PORT INSTRUCTIONS

Darca Plus Eltek Download ing And Remote Con trol Applica tion

Installing LE History Record Reader program software.

Product Overview. Tecan Cavro Components Tecan Cavro innovation is everywhere

(Note if updating the software, delete the old application file from your desktop first, by dragging it to the trash.)

SharePoint AD Administration Tutorial for SharePoint 2007

Orifice Flow Meter

4D v12 Single User Upgrade Installation Manual

INSTRUMENTS, INC. APLICATION NOTES. FOR THE EAGLE LINE OF SOLAR CONTROLLERS

ACQUITY UPLC Systems with 2D Technology Capabilities Guide

Firmware install with Windows XP

EDAN Instruments Twelve Channel ECG SE-12 Express Tango M2 Interface Notes

Endosafe EndoScan-V. Version User Manual. Copyright 2017 Charles River Laboratories

LabVIEW Pump Control Program Using RS232 and USB

Gen5 & Gen5 Secure User's Guide

Overview. Experiment Specifications. This tutorial will enable you to

Legal Library. In this guide we will review how to download and use our Legal Library tool. Commercial Brokers Association May 2018

Microplate Absorbance Reader Labtech LT-4500

Transcription:

Installation Guide for Multidrop Combi with Valve Driver for Polara RS Overview The Valve for the Multidrop Combi is a unique product that allows users to change and control up to eight reagents using one dispenser. The valve is designed for use with an automated system, the following are requirement components: RapidStak microplate stacker Multidrop Combi bulk reagent dispenser Valve [four options are available] Computer with three serial ports and either Windows XP or Windows 7 operating system Polara RS scheduling software Polara RS driver for Multidrop Combi Step 1: Step 2: Unpack and set up RapidStak with Multidrop Combi and instrument plate as per individual instrument documentation. Place the valve on or beside Combi. Slide all the tubes from the Multidrop Combi Cassette onto the connectors on the Front of the Valve. Step 3: Step 4: Step 5: Install Polara RS software and Code Meter software as per the Installing Polara RS documentation. On the Code meter key there will be a folder titled Drivers open this file. Double click on the CombiSetup_3. msi, follow the instructions of the install wizard. Open Polara RS Laboratory Automation Thermo CRS Ltd. Burlington, ON (905) 332-2000 www.thermoscientific.com/rapidstak 5344 John Lucas Drive L7L 6A6 (905) 332-1114 fax

Step 6 Select Tools and Options on the control bar Step 7: Click on the Equipment Tab on the Options Window and select the Settings button next to the model of RapidStak.

Step 8: Make sure the Mode is set to Normal. Give the RapidStak a name, in the example below name=rapidstak. Check that the Serial Port is the correct number and select the OK button.

Step 9: Select the use instrument 1 checkbox. Next click on the down arrow in the box beside to Device, and select the Multidrop Combi. Then click on the Settings button next to the Multidrop Combi device.

Step 10: To configure the Combi, make sure the Mode is Normal. Add a name to the instrument in Polara RS. In the example below the Name=Combi. The next three step are critical, first you need to select the COM port for the Combi. Click the arrow next to the Port location to select proper COM port. Now you need to configure the valve. Select the COM port that is connected to the valve. Next to Valve Installed click on the drop down box and select the model of valve you are using. There are four valve models available.

Step 11: Next click on the box with the 3 dots next to Reagent configuration.

Step 12: Next add valves and identify reagents per valve. Click on the Add button to add the number of valves you will use.

Step 13: With a valve selected in the left panel, you can change the port number and reagent name in the right hand panel by clicking and typing in the box. Continue until you have added all ports required and named all the ports. Select the OK button.

Step 14: Move onto Polara RS, Select Create an Assay on the top right. Step 15: Drag and drop the Run Protocol function in the Operations Panel into the middle of the page.

Step 16: Click on the Combi box in the centre of the screen. Select the reagent for that step of the process in the Fluid drop down in the Properties panel. Select a protocol from the ProtocolName drop down. Polara RS should pull all the protocols you have saved on the Multidrop Combi. If not just select Refresh Protocol Data in the Operations Tasks.

Step 17: Build your process by draging and dropping Combi functions and selecting reagents or water in the Fluid drop down box of the Properties panel.

Step 18: Select Run this assay in the Tasks panel

Step 19: The Run Assay page should appear. Check the Restack check box if you would like plates to sort back to the source stack at the end of the run. Click on the Start Now button.

Step 20: Process will run. Equipment tab will display operations in real time. END