LRS-12. "Last Mile" SNMP Modem Rack FEATURES

Similar documents
Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

FOMi-40 Fiber Optic Modem with Remote Management

Gmux Modular TDMoIP Gateway FEATURES

Optimux-34, Optimux-25

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

RAD KILOMUX-2100/2104

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer

Optimux-34 Fiber Optic Multiplexer

2/4-wire SHDSL Modem/Multiplexer

ASMi-52. 2/4-Wire SHDSL Modem FEATURES

Optimux-4T1 Four-Channel T1 Multiplexer

This provides an easily configurable solution, flexible enough to meet the specific requirements of a broad range of applications.

Optimux-108, Optimux-106

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

ACE-2002, ACE-2002E. Multiservice Access Concentrators/ ATM Network Termination Units FEATURES

MARKET SEGMENTS AND APPLICATION

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer

ASMi-52 2/4-wire SHDSL Modem/Multiplexer

ETX-102 Carrier Ethernet Demarcation Device

Optimux-108, Optimux-106 Four-Channel E1/T1 and Ethernet Multiplexers

4 Last Mile (Local Loop)

Optimux-1032, Optimux-1025

Megaplex-2100/2104. Data Sheet. Modular Integrated Access Multiplexers

Where to buy > Product page >

FCD-E1, FCD-T1 E1/T1 or Fractional E1/T1 Access Units

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

Gmux-2000 Hub-Site Pseudowire and Voice Trunking Gateway

IPmux-1E. TDMoIP Gateway FEATURES

ASMi-54 SHDSL.bis Modem

ASMi-54 SHDSL.bis Modem

Last Mile (Local Loop)

DXC /1/0 modular multiservice cross connect access node up to 1.2 Gbps matrix. Data Sheet. Multiservice Access Node. The Access Company

Product Overview CHAPTER

Optimux-108, Optimux-106

ASMi-54L. Data Sheet. SHDSL.bis Modem

Multiservice Network Termination Unit

FCD-E1E Managed E1 and Fractional E1 Access Device

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

Optimux-108, Optimux-106

Loop-O 9300 Fiber Optical Mux

VCL-TP, Teleprotection Equipment

ASMi-54L SHDSL.bis Modem

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH. Product Brochure. Copyright: Valiant Communications Limited U.K. INDIA U.S.A.

HS-2. MEGAPLEX-2000/2100 Module. 2-Channel High Speed Data Module DESCRIPTION FEATURES

FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES

Loop-O9330 Fiber Optical Mux

IPmux-16 TDM Pseudowire Access Gateway

Megaplex-2100/2104 Modular Integrated Access Multiplexers

V C ALIANT OMMUNICATIONS. VCL-Gigabit Optical Add-Drop Multiplexer. Product Brochure U.S.A. U.K. INDIA

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer

ISO 9001:2000 Certified Company

IPmux-14. TDMoIP Gateway FEATURES DESCRIPTION

IPmux-11. TDMoIP Gateway DESCRIPTION FEATURES

LOOP-O 9100 STM1 ADM/TM

V C ALIANT OMMUNICATIONS. STM-1 Optical to STM-1 Electrical Converter. Data Sheet & Product Brochure U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

Cisco Prisma II Platform

Specifications Connectors. Chassis backplane consists of passive components. Single or optional redundant power supplies

E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

Prisma II Platform. Optoelectronics

Datasheet. Multi-Service Access Platform OPCOM3500E-12. OPCOM3500E-12 Feature. Raisecom Technology Co., Ltd.

V C ALIANT OMMUNICATIONS. VCL-Ethernet over SDH (Ethernet over STM-1) Product Brochure. Copyright: Valiant Communications Limited U.K.

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

FRM220 Solution Portfolio

5U CWDM Managed Platform SML-5000

16 x E1 G x Ethernet optical multiplexer

ETHERNET FIBER OPTIC CONVERTERS

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

RADview. Element Management System Optimux-4E1, Optimux-4T1 Optimux-4E1L, Optimux-4T1L RAD Data Communications Publication 07/05

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

FCD-155 STM-1/OC-3 Terminal Multiplexer

IPmux-1E TDM Pseudowire Access Gateway

TEX-100. Ethernet Extender User Manual

Metroplex 6000/T1 Global T1 Access Multiplexer HIGHLIGHTS Metroplex 6000 System Overview Diverse Applications Unified System Architecture

Vmux-2120 Voice Trunking Gateway

Megaplex-2100/2104. Modular Integrated Access Multiplexers

VCL-TP, Teleprotection Equipment with Trip Counter Display

FOM-FXO32 / FOM-FXS32 32 Voices (FXS/FXO) POTS Fiber Multiplexer

Megaplex-4100 Next Generation Multiservice Access Node

modules in the MP-4100/4104 chassis (E1/T1, SHDSL, data or voice ports) into IP or MPLS packets for transmission over Ethernet, IP or MPLS networks.

RION ORION TELECOM NETWORKS INC. TELECOM NETWORKS. Optical Multiplexer Product Brochure. Orion Telecom Networks Inc.,

RC702-FX Ethernet over SDH User Manual

ORION TELECOM NETWORKS INC.

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH (GigE) ( Gigabit Ethernet over STM- 4) Product Brochure

Megabit Modem MM300S INSTALLATION GUIDE

ATM OVER PACKET CAPABILITIES

GigaVUE-2404 // Data Sheet

GYM Bilgi Teknolojileri

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company

Overview of the Cisco 2524 and Cisco 2525 Routers

PDH Fiber Transmission Equipment

FB-10/100MMC Series Managed/Unmanaged. 10/100Mbps Fiber Media Converter User Manual

User Manual. RC511/RC512 Series SNMP Manageable, Bandwidth Control, 10/100 Mbps Auto-Sensing Ethernet Copper to Fiber Media Converter

3630 MAINSTREET. Intelligent, high perfomance multiplexing that terminates up to 31 voice or data circuits. PRIMARY RATE MULTIPLEXER Release 5.

Vmux-110. Voice Trunking Gateway FEATURES

Application RTU560 RJ45 RJ45. Management. Switch RJ45 RJ45. Switch 560NMS34 SDSL. Data Sheet Switch 560NMS34. Port 1. Port 2. Port 3.

Product Model 1058 Standalone and Rack Card Product Name VDSL Modem Product Manager John Grant Contact

Transcription:

"Last Mile" SNMP Modem Rack FEATURES Accommodates any combination of 12 HDSL, copper or fiber optic modem cards SNMP management agent Supports modems with or without integrated SNMP agent Management running on UNIX or PC platform HPOV application for management of and remote modems Direct connection to Ethernet for controlling large number of racks from a central management station Two hub versions: ANSI: 4U high, connectors on the back ETSI: 6U high, connectors on the front Optional dual power supplies with full redundancy, AC or DC Hot swapping of cards and power supplies Remote power feed option System clock distribution to all cards for network synchronization Supports Telnet protocol Remote software download via LAN by TFTP protocol via terminal by X-MODEM protocol

DESCRIPTION The, Last Mile SNMP modem rack, is a 12-card hub that accommodates any combination of HDSL, copper and fiber modem cards (see Table 1). All cards, electrical or fiber optic, can be managed by the RADview-HPOV SNMP management system. All cards in the hub have remote control abilities for monitoring and/or controlling remote units. Several cards contain an internal SNMP agent. RADview-HPOV management is available for modules with or without integrated SNMP agent, via the SNMP Control Module (CM-2). The RADview-HPOV station is connected to the LRS- 12 via an integrated Ethernet connection on the CM-2 module. The CM-2 module provides transparent connection to modules with SNMP agent and acts as a proxy SNMP agent for those cards without an agent. APPLICATION is available in two different physical hub versions: ANSI card insertion, LEDs and switches are at the front, but cable connections are at the rear of the hub. This compact, 4U high unit complies with the American ANSI standard. Cards can be hot-swapped without removing cables. ETSI card insertion, LEDs, switches and cable connections are at the front. This version is 30 cm high (almost 6U), and complies with European ETSI standard. Cards can be hot-swapped without removing cables. Both control modules, CM-1 and CM-2, have a station clock connection enabling clock distribution to all cards, so that all cards can be synchronized to the same station clock. can also be managed from an ASCII terminal. In this case, Control Module CM-1 can be used for management of modules with SNMP agent onboard, such as HTU-E1C. CM-2 supports ASCII terminal management for modules with or without on-board SNMP agents. Figure 1. Backbone Data Distribution up to the Customer s Premises

POWER SUPPLIES can operate with single or dual, AC or DC power supplies. Each power supply supports a full rack of cards. The redundant power supply can be replaced during operation, without affecting the system performance (hot-swapping). Cards in the hub can provide remote power feeding for repeaters and remote standalone units. For this purpose, a separate standalone power supply should be ordered (see Ordering). INSTALLATION AND MAINTENANCE All cards can be replaced, or cables removed, during operation, without causing interference to data transmission to/from other cards in the hub. CENTRALIZED NETWORK MANAGEMENT The RADview HPOV/UNIX and RADview-PC provide network management for. RADview manages together with other RAD WAN products such as Megaplex-2100 E1/T1 Multiplexer and DXC DACs products. RADview-HPOV can be integrated into other NMS applications from third party vendors running on the standard HPOV/UNIX platform. can also be managed on a PC platform by RADview-PC, a Windows-based Graphical User Interface (GUI) SNMP platform. Figure 2. Management of Local and Remote Distribution Nodes

Management functionality is provided in accordance with ITU-T Telecommunication Management Network (TMN) recommendations. System management supports real-time monitoring and control of more than 64,000 hubs and connected remote modems at the same time. Several users can simultaneously monitor and control the system. The central and remote sites can be managed in real-time. Performance information is available in graph and table format for the last 24 hours. This information can be saved in a file for accounting purposes. SPECIFICATIONS Number of Slots 12 card slots 1 slot for common logic 2 slots for power supplies Connectors Each card has its own connector options (see specific data sheet on the card for connector types) Power Supply 100 to 240 VAC 47 to 63 Hz, 100W or -48 VDC (± 25%) Network Management Connections RS-232: DB-9 connector Ethernet: Coax (BNC) or RJ-45 connector (Available on CM-2 card only) System clock DB-15 connector Physical ANSI version (B): Height 17.7 cm / 7.0 in (4U) Width 48.2 cm / 19.0 in Depth 32.4 cm / 12.75 in ETSI version (F): Height: 30.0 cm / 11.80 in (6U) Width: 48.2 cm / 19.0 in Depth: 25.3 cm / 9.94 in Environment Temperature: 0-45 C / 32-113 F Humidity: up to 90%, non-condensing Table 1. Modules Product Technolog Type Description y ASMi-24 PR-4 4-wire, sync up to 144 kbps, short range 10 km (6.2 miles) at 64 kbps modulation ASMi-31 IDSL 2-wire, sync/async up to 128 kbps, short range up to 8 km (5 miles) independent of data rate ASMi-50 MSDSL 2/4 wire up to 1152 kbps, extended range modem up to 9.5 km (6 miles) FOMi-E1/T1 Fiber optic sync 1544 kbps (T1) or 2048 kbps (E1), extended range FOMi-40 Fiber optic sync up to 1544 kbps (T1) or 2048 kbps (E1), extended range up to 100 km (62 miles) HTU-E1 HDSL 4-wire 2048 kbps, short range up to 4.8 km (3 miles) HTU-T1 HDSL 4-wire 1544 kbps, short range up to 4.8 km (3 miles) HTU-2 HDSL 4-wire n x 64 up to 2048 kbps, short range up to 4.8 km (3 miles) MTMi-20 QAM 4-wire, sync up to 128 kbps, extended range 14 km (8.7 miles)

ORDERING */$/& Last Mile SNMP modem rack * Specify physical enclosure: F ETSI standard, 6U, connectors on the front B ANSI standard, 4U, connectors on the back $ Specify power supply: AC for 100-260 VAC ACR for dual 100-260 VAC 48 for -48 VDC 48R for dual -48 VDC & Specify control module card type: CM1 for control module card with ASCII terminal management CM2/BNC for control module card with SNMP management and ETHERNET BNC connector CM2/UTP for control module card with SNMP management and ETHERNET UTP connector For modem cards, see individual datasheets. LRS-PS-FEED/+ Standalone power supply for remote power feeding + Specify power supply source: AC for 100-260 VAC 48 for -48 VDC 698-100-02/99 1999 RAD Data Communications Ltd. Specifications are subject to change without prior notice. Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com