USER MANUAL. Longo programmable controller LPC-2.ID2 RFID Card holder. Version 8

Similar documents
USER MANUAL. Longo programmable controller LPC-2.AQ1 Air Quality module. Version 1

USER MANUAL. Longo programmable controller LPC-2.CH1M Card Holder module. Version 3

USER MANUAL. Longo programmable controller LPC-2.CA1M Card Reader module. Version 2

USER MANUAL. Longo programmable controller LPC-2.CR1 Card Reader module. Version 5

USER MANUAL. Longo programmable controller LPC-2.SM6 Multisensor. Version 4

USER MANUAL. Longo programmable controller LPC-2.IR2V Multisensor. Version 4

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

USER MANUAL. Longo programmable controller LPC-2.EO1 EnOcean Wireless module. Version 1

USER MANUAL. Longo programmable controller LPC-3.IOR.001 Input Output Relay PLC. Version 2

USER MANUAL. 7" Touch Screen LPC-2.PC2. Version 0

IF-80x Outdoor Terminal

Table of Contents SMARTEH ACCESS SYSTEM DESCRIPTION SMARTEH ACCESS 2

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

USER MANUAL. WBV412U01 AC voltage transducer

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Docking station Order no Operation and installation instructions. 1 Safety instructions. 2 Structure of the device.

Access Terminal IF-800

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Speed monitor D / / 2014

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Installation Instructions Model LFMWLT450, Class 1 Series AC-DC Power Supply

Transponder card reader

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

USER MANUAL. WBI412F41 AC current transducer

Transponder card holder

USER MANUAL. WBI414F21 AC current transducer

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

RS232 Control Box. Table of contents

AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine

Electro Magnetic Compatibility (EMC)

TRC-190 User s Manual

RТTH DUAL ROOM SWITCH

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

MC 11 EB-2 Power supply cabinet with external bus, AC version

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

TRIO-DIODE/12-24DC/2X10/1X20

TM3AI4 module TM3-4 analog inputs

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

M-Bus Central Unit. Use

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

Rhino PSM Power Supplies. Operating Instructions

RXTP ROOM TEMPERATURE

PHOENIX CONTACT - 07/2006

Display Panel BAT 100 LSN. en Operation Guide

Conductive Level Controller

USER MANUAL. RC-43T Remote Controller MODEL: P/N: Rev 3

SMVector Additional I/O Module Installation and Operation Manual

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

EZ864 UMTS Terminal Telit Cellular GSM Engine

Technical Datasheet clima RCM-FC 1. Product description

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

CPCI-PS24 24V-Power Supply

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN

Communicative controller for VAV systems

MINI-PS AC/10-15DC/8

MDM 011-Z1 Regen Resistor

TM3TI4 module TM3-4 inputs temperature

RXTH DUAL ROOM SENSOR / SWITCH

Quick Startup Guide. datafeed uagate SI. Version: EN Copyright 2016 Softing Industrial Automation GmbH

Motor Control and Protection Unit M10x AO Module User Guide

Channel Switch CS. General Operating, Maintenance and Installation Manual

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

Operating Instructions Differential Pressure Transducer PS27

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Temperature controller Ducted systems

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Technical Datasheet clima RCM-CC

Room unit with PPS2 interface

REX F-0-9 Standalone or Access Controller

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Non-communicating room controllers

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

USER MANUAL RC-76M/RC-712M MODEL: P/N: Rev 3

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Operating instructions. Standstill monitor A / / 2011

USER MANUAL. SL-10 Master Room Controller MODEL: P/N: Rev 4

Accessories for stand-alone gird inverter SMART LOAD 6000

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

USER MANUAL. RC-74DL Master Room Controller MODEL: P/N: Rev 4

Transcription:

USER MANUAL Longo programmable controller LPC-2.ID2 RFID Card holder Version 8 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0) 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si

Written by SMARTEH d.o.o. Copyright 2012, SMARTEH d.o.o. User Manual Document Version: 008 July 1, 2012 i

STANDARDS AND PROVISIONS: Standards, recommendations, regulations and provisions of the country in which the devices will operate, must be considered while planning and setting up electrical devices. Work on 100.. 240 V AC network is allowed for authorized personnel only. DANGER WARNINGS: Devices or modules must be protected from moisture, dirt and damage during transport, storing and operation. WARRANTY CONDITIONS: For all modules LONGO LPC-2 if no modifications are performed upon and are correctly connected by authorized personnel in consideration of maximum allowed connecting power, warranty of 24 months is valid from the date of sale to the end buyer, but not more than 36 months after delivery from Smarteh. In case of claims within warranty time, which are based on material malfunctions the producer offers free replacement. The method of return of malfunctioned module, together with description, can be arranged with our authorized representative. Warranty does not include damage due to transport or because of unconsidered corresponding regulations of the country, where the module is installed. This device must be connected properly by the provided connection scheme in this manual. Misconnections may result in device damage, fire or personal injury. Hazardous voltage in the device can cause electric shock and may result in personal injury or death. NEVER SERVICE THIS PRODUCT YOURSELF! This device must not be installed in the systems critical for life (e.g. medical devices, aircrafts, etc.). If the device is used in a manner not specified by the manufacturer, the degree of protection provided by the equipment may be impaired. Waste electrical and electronic equipment (WEEE) must be collected separately! LONGO LPC-2 complies to the following standards: EMC: EN 61000-6-3:2007 + A1:2011, EN 61000-6-1:2007, EN 61000-3-2:2006 + A1:2009 + A2: 2009, EN 61000-3-3:2013 LVD: IEC 61010-1:2010 (3 rd Ed.), IEC 61010-2-201:2013 (1 st Ed.) Smarteh d.o.o. operates a policy of continuous development. Therefore we reserve the right to make changes and improvements to any of the products described in this manual without any prior notice. MANUFACTURER: SMARTEH d.o.o. Poljubinj 114 5220 Tolmin Slovenia ii

Longo programmable controller LPC-2.ID2 1 DESCRIPTION...1 2 FEATURES...2 3 INSTALLATION...3 3.1 Connection scheme...3 3.2 Mounting instructions...5 3.3 Module labeling...7 4 TECHNICAL SPECIFICATIONS...8 5 PROGRAMMERS GUIDE...9 6 CHANGES...11 7 NOTES...12 iii

1 DESCRIPTION LPC-2.ID2 card reader (RFID identification) special module is used to register presence in the room. It is also used as identification card holder. Once a person has entered to the room, the identification card (ID card) must be inserted to the LPC-2.ID2 card holder. If ID card for correspondent room is valid (valid ID card number), several actions can be started (e.g. room light and air conditioning switched on) (use LPC Manager for function logics). LPC-2.ID2 module is also used to activate and present messages DO NOT DISTURB and ROOM SERVICE - use LPC Manager for function logics - (refer to the Table 5). LPC-2.ID2 is connected to the main module RS485 port using interconnection cable (e.g. SIC4-7) which must be ordered together with LPC-2.ID2 reader. When more special modules (e.g. LPC-2.ID1, LPC-2.ID2, LPC-2.P01) are connected to main module, splitter (e.g. SPL-2) is also required. In case that other (magnet or contact chip) card system is used for door unlock, LPC-2.ID2 module can be used to activate and show messages. Module is also used as card holder. When card is inserted to LPC-2.ID2 holder, mechanical switch is activated and status is activated (use LPC Manager for function programming). NOTE: For proper system configuration and data allocation please refer to LPC Composer software help menu. LPC-2.ID2 module can be modified on customer request (front label changed, push buttons added, LEDs added). Please contact manufacturer for more information. 1

2 FEATURES Figure 1: LPC-2.ID2 special module. Table 1: Technical data RFID identification 2 LEDs for DO NOT DISURB and ROOM SERVICE status 2 pushbuttons for DO NOT DISURB and ROOM SERVICE request Power LED Internal fault LED Digital input Relay output 2

3 INSTALLATION 3.1 Connection scheme Figure 2: Connection scheme 3

Table 2: K1 K1.1 GND Ground K1.2 9 V DC Power supply input K1.3 Standard RS-485 A Data receive/send line A K1.4 Standard RS-485 B Data receive/send line B Table 3: K2 K2.1 Voltage free contact Make contact (NO) K2.2 Voltage free contact Make contact (NO) Table 4: K3 K3.1 9 V DC Power supply output K3.2 Digital input, 0.. 9 V DC 9 V DC digital input Table 5: LEDs & Buttons Power LED (on the upper side of the module) Internal fault LED (on the upper side of the module) DO NOT DISTURB, ROOM SERVICE DO NOT DISTURB, ROOM SERVICE Green LED: indicates power supply status Red LED: indicates LPC-2.ID1 communication state Green LED: indicates correspondent signal presence Pushbuttons: user request On: power supply OK Off: power supply missing or power off On: RS485 communication fault Off: RS485 communication OK On: signal present Off: signal not present When pressed, user request message is sent (e.g. to the information desk) 4

3.2 Mounting instructions Figure 3: Housing dimensions 29 Dimensions in milimeters. Mounting instructions: All connections, module attachments and assembling must be done while module is not connected to the main power supply. The LPC-2.ID2 module should be positioned on the wall inside the room. It is advised to avoid direct sunlight or position near heating/cooling source object. Round flush-mounting box (e.g. Gewiss GW 24232), Φ60 mm is recommended for installation. A box must be installed with screw holes in the horizontal position! 1. Mount LPC-2.ID2 module back plate to the provided leveled place on the wall. 2. Fasten 2 screws (DIN 7981 or similar, Φ3 mm, max. head height 3 mm) to fix LPC-2.ID2 module to its place. 3. Connect interconnection cable to the interconnection connector K1. Max. allowed tractive force is 30 N. 4. Power (PWR) green LED should switch on according to the Table 5. 5. Mount LPC-2.ID2 module front plate to the back plate. IMPORTANT: Front plate must be placed in order that switch S1 (according to the Figure 2) is pressed (normally is released). 6. Fasten the screw in the bottom carefully (not too strong), to fix the front plate to the back plate. 5

NOTE: LPC-2.MC3 main control module should be powered separately from other electrical appliance connected to LPC-2 system. Signal wires must be installed separately from power and high voltage wires in accordance with general industry electrical installation standard. Signal wires must be installed separately from power and high voltage wires in accordance with general industry electrical installation standard. Several RFID panels should not be mounted close to each other. Minimum distance to next panel is at least 30 cm. This restrict also applies in cases of mounting panels on both sides of the wall. Adequate shielding material and provisions should be used to avoid interference between panels. 6

3.3 Module labeling Figure 5: Labels on housing Label 1 (MC3 sample): Label 2 (MC3 sample): Label 1 description: 1. LPC-2.MC3 is the full product name. 2. P/N:225MC3040001001 is the part number. 225 general code for product family, MC3 short product name, 04001 sequence code, 04 year of code opening, 001 derivation code, 001 version code (reserved for future HW and/or SW firmware upgrades). 3. D/C:16/05 is the date code. 16 week and 05 year of production. Label 2 description: 1. S/N:MC3-S9-0500000190 is the serial number. MC3 short product name, S9 user code (test procedure, e.g. Smarteh person xxx), 0500000190 year and current stack code, 05 year (last two cyphers), 00000190 current stack number; previous module would have the stack number 00000189 and the next one 00000191. 7

4 TECHNICAL SPECIFICATIONS Table 5: Technical specifications Power supply Interconnection connector type Power consumption RFID type Max. reading distance K2 output: Number of outputs Nominal switching capacity Max. switching power Max. switching voltage Max. switching current Min. switching capacity Insulation Dimensions (L x W x H) Weight from main module (LPC-2.MC7) Berg M 0.5 W Manchester 64, read only 8 cm 1 SPST NO relay output 2 A, 30 V DC 60 W 220 V DC 2 A 10 ua, 10 mv DC Basic, do not connect mains voltage 80 x 110 x 26 mm 80 g Ambient temperature 0 to 50 C Ambient humidity Maximum altitude Mounting position max. 95 %, no condensation 2000 m vertical Transport and storage temperature -20 to 60 C Pollution degree 2 Protection class IP 30 8

5 PROGRAMMERS GUIDE Variables There are 22 bytes available for reading and writing from/to ID2 module. While whole frame of 26 bytes is transferred at a time, LPC Manager variables described in the table below are accessed separately. variable Comm. status New ID received BIT2 BIT3 BIT4 BIT5 BIT6 Door switch status VBOOL8 (#N) range 0..1 variable Occupancy switch status BIT1 DO NOT DISTURB PB ROOM SERVICE PB BIT4 BIT5 BIT6 BIT7 VBOOL8 (#N+1) range 0..1 9

variable Relay output command BIT1 BIT2 Buzzer command Received ID OK command Received ID Fault command BIT6 BIT7 VBOOL8 (#N+2) range 0.. 1 variable BIT0 BIT1 DO NOT DISTURB LED ROOM SERVICE LED BIT4 BIT5 Reserved Reserved VBOOL8 (#N+3) range 0.. 1 variable Received ID WORD1 Received ID WORD2 Received ID WORD3 WORD4 WORD5 WORD6 WORD7 WORD8 WORD9 WORD10 VWORD16 (#N+4) range 0.. 65535 10

6 CHANGES The following table describes all the changes to the document. Date V. Description 1.7.2012 008 CGP General update. 11.5.2010 007 Updated warranty permanence. 2.8.2007 006 - updated K2 output specs - updated description about connecting to main module 26.4.2007 005 - connection scheme updated - updated power supply source 15.3.2006 004 - Added: relay contacts rating - Added: pollution degree class 27.3.2005 003 The initial version, issues as LPC-2.ID2 module User Manual. 11

7 NOTES 12