Digital electropneumatic positioner SideControl

Similar documents
Digital electropneumatic positioner

Digital electropneumatic positioner

Digital electropneumatic positioner

Digital electropneumatic Positioner SideControl

Digital electropneumatic Process Controller

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process

Digital electropneumatic Positioner for the integrated mounting on process control valves

Pneumatic Control/Feedback

Digital electropneumatic Positioner for the integrated mounting on process control valves

Control Head for the integrated mounting on process valves

Pneumatic Control/Feedback

Pneumatic Control Unit for the integrated mounting on process valves

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves

Control head for decentralized automation of ELEMENT process valves

Pneumatic Control/Feedback

SideControl Positioner

Control head for hygienic process valves

LFC Liquid Flow Controller

T EN TROVIS Electropneumatic Positioner

Electromotive process valve - 2 way angle-seat shut-off valve

Series 3730 Type Electropneumatic Positioner

Fieldbus Gateway Type ME43

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Digital Positioner 8049

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

Series 3730 Electropneumatic Positioner Type

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Electromotive process valve - 2 way shut-off globe valve

Pressure sensors SDE3, with display

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Type 8791 Positioner SideControl BASIC. Quickstart. English / Deutsch / Français

По вопросам продаж и поддержки обращайтесь:

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Series 3730 Type Electropneumatic Positioner

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Installation kits for hygienic process valves

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Mass Flow Meter (MFM) for Gases

System Control Unit (SCU)

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

Type 8694 Positioner TopControl Basic. Quickstart. English Deutsch Français

Mass Flow Meter (MFM) for Gases

Data Sheet T EN

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Remote Process Actuation Control System AirLINE PHOENIX INLINE

Technical Data. General specifications. Rated operating distance s n 3 mm

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Type 8792, Electropneumatic positioner and process controller. Operating Instructions

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

Type 8792, Quickstart. English Deutsch Français

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Type 8692, Positioner and process controller Positioner und Prozessregler Positionneur et régulateur de process. Quickstart

Remote Process Actuation Control System AirLINE PHOENIX INLINE

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

Sensor boxes SRBG Key features

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Replacement Positioner SideControl Typ 1067

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Inductive sensor NI3-EG08K-Y1-H1341

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Inductive sensor BI1.5-EG08-Y1-H1341

PROFIBUS-PA Positioner Type 3785

GEMÜ 4232 Travel sensor for linear actuators

Mass Flow Meter (MFM)

Electronic pressure switch with display Model PSD-4

Sensor boxes SRBE Key features and product range overview

Rotary Measuring Technology Absolute encoders, Singleturn, Profibus-DP

Inductive sensor BI1.5-EG08-Y1-H1341

Series 3730 Electropneumatic Positioner Type with HART communication and pressure sensors

HERION SERIES Indirect solenoid actuated spool valves

Series 3730 Type Electropneumatic Positioner

Material Seat seal. N/en

11 PROFIBUS Fieldbus Connector

Flow sensors SFAB Key features

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

GEMÜ 1235 Electrical position indicator

Data Sheet T EN

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

24011 series, 3/2 Direct solenoid actuated poppet valve

Series 3730 Type Electropneumatic Positioner with HART communication and pressure sensors

Transcription:

Digital electropneumatic positioner Type 879 can be combined with Compact and robust design Easy to start using tune function Integrated diagnostic functions for valve monitoring (optional) Dynamic positioning system with no air consumption in controlled state PROFIBUS DP-V1 or DeviceNet (optional) Yoke type actuators Rotary actuators Rotary actuators with remote positioner Process control valve with remote positioner Hygienic process control valve with remote positioner The robust and compact positioner is designed to standardisation acc. to IEC 605-6-1 or VDI/VDE 85 (IEC 605-6-) for assembly with linear and rotary actuators. In addition, the remote version with the displacement position sensor can be combined with Bürkert process control valves. The digital electropneumatic positioner can be operated with the usual current and voltage standard signals and can also be equipped with the fieldbus interface PROFIBUS DP-V1 or DeviceNet. The positioner is equipped with additional diagnostic functions to monitor the state of the valve. Through status signals, valve diagnostic messages are transmitted according to NAMUR NE 107 recommendations and recorded as history. With the diagnosis, the operating conditions of the control valve can be monitored. This allows planned maintenance and optimises plant availability. Operation occurs via the external operation and display module with a backlit graphical display. The user operation is very simple and clear, identical to the Bürkert positioner or process controller TopControl, Type 869/869. The pilot valve system can be used equally for single and double-acting drives. It is characterised by a defined safety feature in case of failure of the electrical or pneumatic power supply and possesses an enormous air capacity range with pressure supply up to 7 bar. Technical data Material Body Seal Aluminium plastic-coated EPDM, NBR, FKM Operating voltages V DC +/- 10% Residual ripple Max. 10% Setpoint setting 0/ to 0 ma and 0 to 5/10 V Input resistance 0/ to 0 ma: 180 Ω 0 to 5/10 V: 19 kω Analogue feedback -0 ma, 0-0 ma 0-10 V, 0-5 V Binary input Galvanically isolated, 0-5 V = log 0, 10-0 V = log 1 Binary output Current limit Control medium Dust concentration Particle density Pressure condensation point Oil concentration Ambient temperature Outputs (optional), galvanically separated 100 ma, Output will be synchronised when overloaded neutral gases, air, quality classes acc. to ISO 857-1 Class 7 (<0 μm particle size) Class 5 (<10 mg/m ) Class (<-0 C) Class X (<5 mg/m ) -10 to +60 C (without Ex-Approval) 0 to +60 C (with ATEX / IECEx-Approval) Pilot air ports Threaded ports G 1/ Supply pressure 1) ) 1. to 7 bar Air supply filter Exchangeable (aperture size ~0.1 mm) Actuator system Air capacity Single and double-acting to 150 l N /min. 50 l N /min (with 1. bar ) ) for aeration and ventilation 150 l N /min (with 6 bar ) ) for aeration and ventilation (Q Nn = 100 l N /min (acc. to the defi nition with decrease in pressure from 7 to 6 bar absolute) Position detection module Potentiometer, max. angle 180º Stroke range valve spindle Min. 0º on the rotary shaft, depending on lever Installation As required, display above or sideways 1) The supply pressure has to be 0.5-1 bar above the minimum required pilot pressure for the valve actuator ) Pressure specifi cations: Overpressure with respect to atmospheric pressure continued on next page www.burkert.com p. 1/17

Technical data, continued Technical data Type of protection Power consumption Electrical connection Multipole connection Cable gland IP65/IP67 acc. to EN 6059, Type X acc. to NEMA 50 standard < 5 W M1, 8-pin/-pin; M8, -pin x M0x1.5 (cable Ø 6-1 mm) on screw terminals (0.1-1.5 mm ) 1x M1x1.5 (cable Ø -6.5 mm) Remote version Bus communication PROFIBUS DP-V1 or DeviceNet Protection class III acc. to DIN EN 6110 Conformity EMC directive 01/0/EU CSA approval information Product category code Considered standards CAN/CSA-C No. 19 UL 9 CSA trademark Class 1 8-VALVES - Actuators - Certifi ed to US standards Class 1 0-VALVES - Actuators Ex-Approval ATEX IECEx II G Ex ec ic IIC T Gc / II D Ex tc IIIC T15 C Dc Certifi cate; BVS 16 ATEX E 118 X Ex ec ic IIC T Gc / Ex tc IIIC T15 C Dc Certifi cate; IECEx BVS 16.0091 X Technical data - Linear Remote Position Sensor (ELEMENT) Electrical connection Cable gland Connection cable length 1x M16x1.5 (cable Ø 5-10 mm) on terminal screws (0.1-1.5 mm²) 10 m Operating voltage V DC ± 10 % Power consumption < 0. W Sensor measurement range to 5 mm (Stroke range valve spindle) Actual position signal digital (RS85) Ambient temperature -5 to +80 C Protection class III acc. to DIN EN 6110 Type of protection IP65 and IP67 acc. to EN 6059, Type X acc. to NEMA 50 standard Type of Ignition protection II D Ex tc IIIC T15 C Dc II G Ex na IIC T Gc Conformity EMC directive 01/0/EU Approvals culus Certifi cate no. 8179 Technical data - rotative Remote Position Sensor (NAMUR) Electrical connection m round cable (shielded) Operating voltage 10 to 0 V DC Residual ripple < 0.8 W Sensor measurement range 0º to 60º Actual position signal digital (RS85) Ambient temperature -5 to +80 ºC Protection class III acc. to DIN EN 6110 Type of protection IP65 acc. to EN 6059 Conformity EMC directive 01/0/EU Approvals UL (culus) Certifi cate no. E6909 Technical data - Position feedback with proximity switches (Accessory) Electrical connection M1, -pin Output function -wire, normally open contact, PNP Operating voltage 10 to 0 V DC Residual ripple 10% U ss DC rated current 100 ma Type of protection IP65 and IP67 Protection class III acc. to DIN EN 6110 Conformity EMC directive 01/0/EU Approvals ccsaus Using a remote positioner the length of the control air pipes influences the dynamics and attainable accuracy of the position control loop. The length of the control air pipes therefore should be as short as possible. Note: The position feedback has two proximity switches which are independently adjustable via switch lugs. p. /17

Example of assembly variations of positioner Positioner Type 879 879 NAMUR 879 Remote Positioner 879 Linear actuators IEC 605-6-1 Rotary actuators VDI/VDE 85 (IEC 605-6-) Type 8805 + Type 879 Linear actuators IEC 605-6-1 Rotary actuators VDI/VDE 85 (IEC 605-6-) Type 8798 Sensor Remote NAMUR + Type 879 Remote Control valve system Type 00 + Type 8798 Remote Position Sensor + Type 879 Remote p. /17

Assembly options NAMUR Version (Positioner with integrated position sensor, assembly acc. to NAMUR/IEC 605-6-1 and VDI/VDE 85 (IEC 605-6-)) Assembly on linear actuator Assembly on rotary actuator Description Adapter kit 787 15 Description Adapter kit 787 8 Assembly bridge 770 9 Dimensions [mm] Adapter kit 5 Assembly bridge 1 R 0 50 R7 19,5 Actuator shaft A B C height 0 6.5 80-0 56.5 80 10 50 76.5-10 ( B ) 107,6 A C Position feedback with proximity switches (upgrade feature for NAMUR) External position indicator Cover for standard display element Housing cover Description C ti t l iti i di t Position feedback 677 18 p. /17

Assembly options continued Remote version (Displaced positioner with external remote position sensor) Assembly with accessory brackets Dimensions [mm] Description Assembly bracket for wall mounting 675 715 Assembly on DIN-Rail Dimensions [mm] x 90º The adapter can be turned every 90º on the DIN-Rail Description DIN rail assembly kit 675 70 p. 5/17

Assembly options continued Remote version (Remote position sensor for displaced positioner) Type 8798 Description Standard ATEX II GD Remote Position Sensor Control valves ELEMENT Types xx 1 60 6 860 Description Remote Position Sensor NAMUR 11 56 Dimensions For mounting on Control valves ELEMENT Types xx p. 6/17

Dimensions Mounting on control valves according to NAMUR (IEC 605-6-1 / VDI/VDE 85 (IEC 605-6-)) SW 17 6.1 80 50 6 6 0 8 0 5.5 91 p. 7/17

Ordering Chart (further version on request) Positioner Type 879 Assembly variations Electrical connection Item No. Assembly variations Control function Pilot valve system /Air capacity Communi cation Electrical connection Analogue feedback Binary outputs Binary Input Diagnostic functions* ATEX II GD / IECEx no no yes 06 610 NAMUR IEC 605-6-1 VDI/VDE 85 (IEC 605-6-) Single and doubleacting Universal No PROFIBUS DP-V1 DeviceNet Cable gland Multipole no yes yes yes 06 61 yes yes yes yes 06 611 yes yes yes yes yes 10 06 no no yes 06 61 no yes yes yes 06 615 yes yes yes yes 06 61 via Bus no yes 06 616 via Bus no yes yes 10 08 via Bus yes yes yes yes 10 09 via Bus yes yes yes 06 617 no no yes 9 09 no yes yes yes 9 095 Assembly variations ELEMENT Actuator size Control function Pilot valve system /Air Capacity Communi cation Electrical connection Analogue feedback Binary outputs Binary Input Diagnostic functions* ATEX II GD / IECEx Ø 70/90 mm Singleacting Low yes yes yes yes 870 no yes yes yes 871 Remote Ø 10 mm Single and doubleacting Universal no Cable gland no no yes 06 6 yes yes yes yes 06 6 no yes yes yes 06 65 yes yes yes yes yes 10 10 Remote Position Sensor Standard ATEX II GD/ IECEx ELEMENT Type xx Cable gland - 10 m round cable 1 60 6 860 NAMUR (rotative) Cable gland - m round cable (max. extension 10 m ) *see additional software functions parametrisable diagnostic functions on page 1 11 56 - p. 8/17

Ordering chart for accessories Description Accessories for NAMUR Assembly bridge VDI/VDE 85 (IEC 605-6-), stainless steel 770 9 Adapter kit VDI/VDE 85 (IEC 605-6-), stainless steel 787 8 Adapter kit linear actuators IEC 605-6-1, stainless steel 787 15 Position feedback with proximity switches (optional upgrade feature) ) 677 18 Accessories for Remote Bracket for wall mounting, stainless steel 675 715 DIN rail assembly kit, Aluminium/stainless steel 675 70 Adapter kit - remote sensor, ELEMENT Type xx control valves Actuator size Ø 70/90/10 mm 679 917 Sensor Puck (replacement part) 68 0 Standard Accessories USB Interface for serial communication 7 09 M1 socket 8-pin with 5 m cable for power supply and input/output signals 919 67 M8 plug -pin for binary outputs, with solder joints 917 11 Silencer G 1/ (spare part) 780 780 * Related Communication software can be downloaded from www.buerkert.com (879) ) External end position feedback for upgrading NAMUR p. 9/17

Connection options Multi-pin connection Operating voltages and diverse signals Binary output optional 1 8 7 1 6 Circular connector M1, 8-pin 5 FE Earth plate functions Socket M8, -pin Circular connector M1-8-pin (Setpoint) Pin Configuration External Circuitry / signal level 1 Setpoint + (0/-0 ma or 0-5/10 V) 1 + (-0 ma or 0-10 V) Complete galvanically separated Setpoint GND GND GND V DC ± 10% Max. Residual ripple 10% + V 5 Binary input + 5 + 0-5 V (log. 0) 10-0 V (log. 1) 6 Binary input GND 6 GND Optional analogue feedback 8 Analogue feedback + 8 + (0/-0 ma or 0-5/10 V, ) Complete galvanically separated 7 Analogue feedback GND 7 GND Socket M8, -pin (only with Binary Output Option) Pin Configuration External Circuitry / signal level 1 Binary Output 1 1 V / 0 V, NC / NO relative to operating voltage GND (terminal GND) Binary Output V / 0 V, NC / NO relative to operating voltage GND (terminal GND) Binary Output GND GND Electrical connection Position feedback with proximity switches (accessory for upgrading) Proximity switch 1 Proximity switch 1 Pin Config. External circuit /signal level 1 Supply +10 V... +0 V 1 10... 0 V 10... 0 V Switching output +10 V... +0 V Open / 10... 0 V (NO) Proximity switch 1 GND GND GND Switching output (NO) Proximity switch +10 V... +0 V Open / 10... 0 V p. 10/17

Connection options, continued Connection PROFIBUS DP 5 6 FE Earth plate functions 5 7 8 1 5 1 1 Circular connector M1, 8-pin Socket M1, 5-pin (inverse coded PROFIBUS DP) Circular connector M1, 5-pin (inverse coded, PROFIBUS DP) Operating voltages - Circular connector M1, 8-pin Pin Configuration External Circuitry / signal level 1 Not confi gured Not confi gured GND V DC ± 10 % + V max. Residual ripple 10 % 5 Binary input + 6 Binary input 7 Binary Output 1 (oriented at Pin ) 8 Binary Output (oriented at Pin ) Bus-Connection - socket/circular connector M1, 5-pin Pin Configuration External Circuitry / signal level 1 VP+5 Load resistance supply RxD/TxD-N Receive and send information -N, A Circuitry DGND Information transfer potential (measured to 5 V) RxD/TxD-P Receive and send information -P, B Circuitry 5 Shield Shield / protective earth Bus connection DeviceNet - M1, 5-pole circular connector Pin Signal Colour Configuration 1 Shielding Not used V+ Not used V- Not used 5 CAN H White 1 5 CAN L Blue p. 11/17

Connection options, continued Cable gland connection 1 + V GND 8 + 85 + 1 + 11 + 1 81 + Optional: S + S A B Terminal Configuration External Circuitry / signal level 11 + Setpoint + 11 + + (-0 ma or 0-10 V) Complete galvanically separated 1 Setpoint GND 1 GND 81 + Binary input + 81 + + 05 V (log. 0) 10 V (log. 1) Obtained at GND operating voltages (GND clamps) + V GND Operating voltages + Operating voltages GND + V GND V DC ± 10 % max. Residual ripple 10 % Terminals 1,,, : not connected Optional Analogue feedback / Binary Output Terminal Configuration External Circuitry / signal level 8 + Binary Output 1 8 + V / 0 V, NC / NO Obtained at GND operating voltages ( GND clamps) 85 + Binary Output 85 + V / 0 V, NC / NO Obtained at GND operating voltages ( GND clamps) 1 + Analogue feedback + 1 + + (0/-0 ma or 0-5/10 V) Complete galvanically separated Analogue feedback GND GND Terminal 1,,, : NC Optional remote version in connection with remote positioner sensor Type 8798 Terminal Configuration External Circuitry / signal level A Serial interface, A cable A A line B Serial interface, B cable B B line S + Supply sensor + S + + S - Supply sensor - S - - For version without remote version: terminals A, B, +, - not connected Remote Sensor Remote Sensor Type 8798 Remote sensor Type 8798 Terminal Wire colour for cable type Configuration External Circuitry 1 1 white black Supply Sensor - 1 8791 or brown Supply Sensor + 879 / 879 yellow orange Serial Interface, B line 8791 or green red Serial Interface, A line 879 / 879 p. 1/17 Terminal 1,,, : NC

Signal flow plan Position control loop Additional software options of the positioner Type 879 (extract) Automatic start of the control system Automatic or manual characteristics curves selection Setting of the seal and the maximum stroke threshold respectively Parameterisation of the positioner Limitation of the stroke range Limitation of the manipulating speed Setting of the moving direction Configuration of the binary input Signal range splitting on several controllers Configuration of analogue or binary outputs Signal fault detection Safety position Code protection Contrast inversion of the display Parametisable diagnostic functions* / Binary output (option) Operating-hours counter Path accumulator Position monitoring Graphical display of the dwell time density and movement range Monitoring of the mechanical end positions in the armature *You will find more diagnostic functions with a detailed description in the operating manual for Type 879/9 p. 1/17

Schematic diagram of, Type 879 Without Fieldbus interface Input for Setpoint position value - 0mA, 0-0 ma 0-10 V, 0-5 V Binary input Input Positioner Output Analogue feedback ) -0mA, 0-0mA, 0-10 V, 0-5 V binary outputs V PNP ) V DC 1) Supply Initiator 1/Initiator V PNP NO ) Operation With PROFIBUS DP / DeviceNet Bus Bus Input Positioner PROFIBUS DP/ DeviceNet Output Binary output V PNP ) Binary input Initiator 1 / Initiator V PNP NO ) V DC 1) Supply unit Operation 1) The operating voltage is supplied with a -wire unit independent from the setpoint signal ) Alternative options p. 1/17

Dimensions [mm] NAMUR version Cable gland (standard) 7.5 NAMUR version PROFIBUS DP Multipole 17 A1 A A1 7.5 A 81.8 109.8 A NAMUR version Multipole with Binary outputs NAMUR version Multipole Remote version cable gland A1 A1 A1 A A A 81.9 98.9 R A1 P A L 97. 1.6 9.9 10 5 50 10 Description L A A1 A Standard 171.1 1 0 PROFIBUS DP 157.8 6 1 1.5 Multipole Bin. OUT 157.6 6 1 Mulitpole 157. -.5 Remote 171.1 1 0 11.5 p. 15/17

180 879 Positioner Dimensions [mm], continued The rotation angle of the sensor must be within a range of 180 With the valve open approx. 50%, the sensor indicator should be in this position. Standard Version Remote version p. 16/17

Dimensions [mm], continued ATEX / IECEx version 9.6 111.85 To find your nearest Bürkert facility, click on the orange box www.burkert.com In case of special application conditions, please consult for advice Subject to alterations. Christian Bürkert GmbH & Co. KG 1705/15_EU-en_00895119 p. 17/17