SIMATIC S Update to the S System Manual, edition 03/2014 Product Information

Similar documents
SIMATIC S Update to the S System Manual, edition 03/2014 Product Information

SIMATIC S Update to the S System Manual, edition 01/2015 Product Information

Analog Output Module AQ 4xU/I ST (6ES7135-6HD00-0BA1) SIMATIC. ET 200SP Analog Output Module AQ 4xU/I ST (6ES7135-6HD00-0BA1) Preface

General information. Configuration control. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

ST (6ES7132-6FD00-0BB1)

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview.

SIMATIC S Update to the S System Manual, edition 09/2016 Product Information

General information. Display. Control elements. Supply voltage

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC

Analog output module AQ 2xI ST (6ES7135-6GB00-0BA1) SIMATIC. ET 200SP Analog output module AQ 2xI ST (6ES7135-6GB00-0BA1) Preface. Documentation guide

Analog Output Module AQ 2xU/I ST (6ES7532-5NB00-0AB0) SIMATIC. S7-1500/ET 200MP Analog Output Module AQ 2xU/I ST (6ES7532-5NB00-0AB0) Preface

SIMATIC S Analog output module AQ 4xU/I ST (6ES7532-5HD00-0AB0) Manual. Answers for industry.

Product type designation

Connecting a PC Station to an S using OPC

TIA Portal Workshop. Unrestricted. Siemens AG All rights reserved.

FAQ 12/2015. PROFINET IO Communication.

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Digital input module DI 8x24VDC HS (6ES7131 6BF00 0DA0) SIMATIC ET 200SP (6ES7131 6BF00 0DA0) Preface. Documentation guide.

User Login with RFID Card Reader

Evaluating Diagnostics Data in the User Program

SIMATIC. ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Preface. Properties 1. Parameters 2.

General information. Supply voltage. Input current

General information. Supply voltage. Input current

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

IE/PB LINK PN IO. PROFINET applications

General information. Supply voltage. Input current

General information. Display. Supply voltage

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

Digital input module. DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC. ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Preface

SIMATIC S plus TIA Portal

General information. Supply voltage. Input current

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

Commissioning PC Stations - Manual. and Quick Start SIMATIC NET. PC software Commissioning PC Stations - Manual and Quick Start.

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E09. PROFINET with 2x CPU 315F-2 PN/DP

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

S CPU firmware overview

SIMATIC. S7-1500/ET 200MP Digital input module DI 16x24VDC BA (6ES7521-1BH10-0AA0) Preface. Documentation guide. Product overview.

CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) Preface. Documentation guide. Product overview.

FAQ 03/2014. How do I go online? SIMOTION & SINAMICS.

General information. Display. Supply voltage. Input current

SIMATIC. S7-1500/ET 200MP Analog output module AQ 4xU/I ST (6ES7532-5HD00-0AB0) Preface. Documentation guide. Product overview.

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

SIMATIC S7-300 Product information for the S7-300 Automation System Manual, Module Data

General information. Display. Supply voltage. Input current. Encoder supply. Output current

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

IM PN BA interface module (6ES7155-6AR00-0AN0) SIMATIC. ET 200SP IM PN BA interface module (6ES7155-6AR00-0AN0) Preface

SCE Training Curriculum For Integrated Automation Solutions Totally Integrated Automation (TIA)

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

SIMATIC. S7-1500/ET 200MP Technology module TM Count 2x24V (6ES7550-1AA00-0AB0) Preface. Documentation guide. Product overview.

ST (6ES7522-1BH00-0AB0)

SIMATIC. ET 200SP DQ 4x VAC/2A ST digital output module (6ES7132-6FD00-0BB1) Preface. Guide to documentation. Product overview.

General information. Supply voltage

SIMATIC. S7-1500/ET 200MP Analog Output Module AQ 2xU/I ST (6ES7532-5NB00-0AB0) Preface. Guide to documentation. Product overview.


SINAMICS V: Speed Control of a V20 with S (TIA Portal) via MODBUS RTU, with HMI

SIMATIC. ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Preface. Properties 1. Parameters 2.

IM PN ST interface module (6ES7155-6AU00-0BN0) SIMATIC. ET 200SP IM PN ST interface module (6ES7155-6AU00-0BN0) Preface

Central processing units CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

Digital output module. DQ 16x230VAC/2A ST Relay (6ES7522-5HH00-0AB0) SIMATIC

Digital input module. DI 8x24VDC HF (6ES7131-6BF00-0CA0) SIMATIC. ET 200SP Digital input module DI 8x24VDC HF (6ES7131-6BF00-0CA0) Preface

SIMATIC. ET 200SP Digital output module DI 8x24VDC SRC BA (6ES7131-6BF61-0AA0) Preface. Documentation guide. Product overview.

Interface module IM DP (6ES7157-1AA00-0AB0) SIMATIC. ET 200AL Interface module IM DP (6ES7157-1AA00-0AB0) Preface. Documentation guide

SIMATIC. Automation Systems S7-300 CPU 317T-2 DP: Controlling a SINAMICS S120. Introduction. Preparation 2. Learning units 3. Further Information 4

ST (6ES7522-5HF00-0AB0)

09/2014 SINAMICS G/S: HMI

CPU 412H. Function. Parameterizable properties

Higher-level safe switch-off of the power supply of functionally non-safe standard modules

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS

Cycle and response times SIMATIC. S Cycle and response times. Preface. Documentation guide. Program processing 2. Cyclic program processing 3

Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory

Configuration Control with the S and ET 200SP

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Digital output module. DQ 16x24VDC/0.5A ST (6ES7132-6BH00-0BA0) SIMATIC. ET 200SP Digital output module DQ 16x24VDC/0.5A ST (6ES7132-6BH00-0BA0)

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

CPU 1214C. Overview. Design. The compact CPU 1214C has:

General information. Display. Supply voltage. Input current

SIMATIC. S7-1500/ET 200MP Power supply module PS 60W 24/48/60VDC HF (6ES7505-0RB00-0AB0) Preface. Documentation guide. Product overview.

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

IM DP HF interface module (6ES7155-6BA00-0CN0) SIMATIC. ET 200SP IM DP HF interface module (6ES7155-6BA00-0CN0) Preface

TIA Portal V11 Exercises

SIMATIC ET 200SP Product information on documentation of the ET 200SP distributed I/O system Product Information

SIMATIC. S7-1500/ET 200MP DI 16x230VAC BA Digital Input Module (6ES7521-1FH00-0AA0) Preface. Documentation guide. Product overview.

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

CM PtP RS422/485 BA communication. module (6ES7540 1AB00 0AA0) SIMATIC. S7-1500/ET 200MP CM PtP RS422/485 BA communication module (6ES7540 1AB00 0AA0)

Reading and Writing RFID Data with SIMATIC S and SIMATIC RF160C via PROFIBUS DP

Data sheet VIPA CPU M13C (M13-CCF0000)

Transcription:

SIMATIC S7-1200 Product Information In spite of efforts to ensure the accuracy and clarity in the product documentation, some of the pages in the S7-1200 Programmable Controller System Manual contain information that has been identified as being incomplete, incorrect or misleading. Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. You can find more information about industrial security on the Internet (http://www.siemens.com/industrialsecurity). To stay informed about product updates as they occur, sign up for a product-specific newsletter. You can find more information on the Internet (http://support.automation.siemens.com). Siemens AG 2014. All rights reserved A5E03929122-AD, 05/2014 1

This document contains the following updates AS-i V1.0 to V1.1 firmware upgrade power cycle requirement (Page 2) DTL (Date and Time Long) data value restriction (Page 3) SIMATIC MC 32 GB (Page 3) RF120C Communications module (Page 3) Monitoring execution status (Page 3) Correction of relay performance data (Page 3) SM 1221 DI 16 x 24 VDC connector pin locations (Page 4) Effect of data logs on memory cards (Page 4) Calculating the size of a data log file (Page 4) Maximum size rule for data log files (Page 4) Measurement ranges of the analog inputs for voltage (SB and SM) (Page 5) Upload device as new station (Page 5) Use of the DPRD_DAT and DPWR_DAT instructions to access consistent data (Page 6) Parameter description update for TSEND_C and TRCV_C instructions (Page 7) Read access security level for the CPU (Page 7) Spare parts compatibility for communication modules (Page 7) Behavior of RCV_PTP instruction (Page 8) Uploading program blocks from online CPU to offline project (Page 8) Configuring the SM 1278 4 x IO-Link Master (Page 8) Number of asynchronous communication connections supported (Page 9) SB 1231 AI 1 x 12 bit (Page 10) TeleService modules (Page 11) SM 1232, SM 1234, and SB 1232 analog output tables (Page 11) AS-i V1.0 to V1.1 firmware upgrade power cycle requirement For V4.0 S7-1200 CPUs, if using the web server or a SIMATIC Memory card to upgrade from V1.0 to V1.1 AS-i firmware, you must update the AS-i firmware in the AS-i Master CM 1243-2 according to the following procedure: 1. Download the firmware upgrade to the AS-i Master CM 1243-2. 2. When the download is complete, power cycle the S7-1200 CPU to complete the firmware upgrade process in the AS-i Master CM 1243-2. 3. Repeat steps 1 and 2 for each additional AS-i Master CM 1243-2. The S7-1200 PLC allows a maximum of three AS-i Master CM 1243-2. 2 A5E03929122-AD, 05/2014

DTL (Date and Time Long) data value restriction The maximum value for the DTL data type is reduced to correct a compatibility issue. Table 1 From: Maximum DTL value, as stated in the system manual Year Month Day Hour Minute Second Nanosecond 2554 12 31 23 59 59 999 999 999 DTL#2554-12-31-23:59:59.999 999 999 Table 2 To: New maximum DTL value Year Month Day Hour Minute Second Nanosecond 2262 04 11 23 47 16 854 775 807 DTL#2262-04-11:23:47:16.854 775 807 SIMATIC MC 32 GB Consult with your Siemens contact or distributor for availability of the 32 GB SIMATIC Memory Card, order number 6ES7 954-8LT02-0AA00. RF120C Communications module The RF120C allows Siemens RFID and code reading systems to be connected directly and easily to an S7-1200. The reader is connected to the RF120C via a point-to-point connection. Up to three communications modules can be connected to an S7-1200 to the left of the CPU. The RF120C communications module is configured via the TIA Portal. The order number for the RF120C communications module is 6GT2002-0LA00. For more information about this product and for the product documentation, refer to the product catalog web site for the RF120C. (http://support.automation.siemens.com/ww/view/en/78961671) Monitoring execution status When monitoring program execution status, you can see value updates for a maximum of 50 data elements. Scrolling the program block window allows you to view status for data elements of other instructions. Correction of relay performance data The Typical performance data table (Table A-8) has been corrected as shown below. The number of operating cycles (typical) is 2.0 million (not 12.0 million). Table 3 Typical performance data Switching capacity and life of the contacts For ohmic load Voltage Current Number of operating cycles (typical) 230 VAC 0.5A 2.0 million A5E03929122-AD, 05/2014 3

SM 1221 DI 16 x 24 VDC connector pin locations The connector pin locations table (Table A-108) has been corrected and is shown below. Table 4 Connector pin locations for SM 1221 DI 16 x 24 VDC (6ES7 221-1BH32-0XB0) Pin X10 X11 X12 X13 1 No connection GND No connection No connection 2 No connection No connection No connection No connection 3 1M 2M 3 M 4 M 4 DI a.0 DI a.4 DI b.0 DI b.4 5 DI a.1 DI a.5 DI b.1 DI b.5 6 DI a.2 DI a.6 DI b.2 DI b.6 7 DI a.3 DI a.7 DI b.3 DI b.7 Effect of data logs on memory cards Note To ensure the overall performance and robustness of your system, limit the data log rate to no faster than every 200 ms. Calculating the size of a data log file The data log data bytes calculation in section 8.7.2.4 is incorrect. The correct calculation is shown below. Data log data bytes = ((data bytes in one record + time stamp bytes + 12 bytes) * number of records) Maximum size rule for data log files The maximum size of one data log file cannot exceed the free load memory size or 500 megabytes, whichever is smaller. The size of 500 megabytes in this case refers to the decimal definition of megabyte, such that the maximum data log file size is 500,000,000 bytes or 500 x 1000 2 bytes. 4 A5E03929122-AD, 05/2014

Measurement ranges of the analog inputs for voltage (SB and SM) The following table (Table A-159) has been updated to describe other uses of the value 7FFF. Table 5 Analog input representation for voltage (SB and SM) System Voltage Measuring Range Decimal Hexadecimal ±10 V ±5 V ±2.5 V ±1.25 V 32767 7FFF 1 11.851 V 5.926 V 2.963 V 1.481 V Overflow 32512 7F00 32511 7EFF 11.759 V 5.879 V 2.940 V 1.470 V Overshoot range 27649 6C01 27648 6C00 10 V 5 V 2.5 V 1.250 V Rated range 20736 5100 7.5 V 3.75 V 1.875 V 0.938 V 1 1 361.7 μv 180.8 μv 90.4 μv 45.2 μv 0 0 0 V 0 V 0 V 0 V -1 FFFF -20736 AF00-7.5 V -3.75 V -1.875 V -0.938 V -27648 9400-10 V -5 V -2.5 V -1.250 V -27649 93FF Undershoot range -32512 8100-11.759 V -5.879 V -2.940 V -1.470 V -32513 80FF Underflow -32768 8000-11.851 V -5.926 V -2.963 V -1.481 V 1 7FFF can be returned for one of the following reasons: overflow (as noted in this table), before valid values are available (for example immediately upon a power up), or if a wire break is detected. Upload device as new station You can now upload a device as a new station from the Online menu. In Online menu, the "Upload device as new station (hardware and software)" menu command uploads the hardware configuration and software from a device connected online and creates a new station in the project. This is an alternative to detecting the configuration of an unspecified CPU and then uploading the software from the CPU as described in sections 5.2 and 6.8 of the system manual. A5E03929122-AD, 05/2014 5

Use of the DPRD_DAT and DPWR_DAT instructions to access consistent data The DPRD_DAT and DPWR_DAT instructions in Table 8-78 and following paragraph are corrected and shown below: Table 6 DPRD_DAT and DPWR_DAT instructions LAD / FBD SCL Description ret_val := DPRD_DAT( laddr:=_word_in_, record=>_variant_out_); ret_val := DPWR_DAT( laddr:=_word_in_, record:=_variant_in_); Use the DPRD_DAT instruction to read one or more bytes of data from one of the following locations: Module in the local base DP standard slave PROFINET I/O device The CPU transfers the data read consistently. If no errors occur during the data transfer, the CPU enters the read data into the target area set up by the RECORD parameter. The target area must have the same length as you configured with STEP 7 for the selected module. When you execute the DPRD_DAT instruction, you can only access the data of one module. The transfer starts at the configured start address. Use the DPWR_DAT instruction to transfer the data in RECORD consistently to the following locations: Addressed module in the local base DP standard slave PROFINET I/O device The source area must have the same length as you configured with STEP 7 for the selected module. The S7-1200 CPU supports up to 64 bytes of consistent data on the local bus. Use the DPRD_DAT and DPWR_DAT instructions to access more than 64 bytes of data consistently. PROFIBUS supports up to 4 bytes of consistent data. Use the DPRD_DAT and DPWR_DAT instructions to access more than 4 bytes of data consistently. PROFINET supports up to 1472 bytes of consistent data. You do not need to use these instructions for consistent transfers between the S7-1200 and PROFINET devices. You can use these instructions for data areas of 1 or more bytes. If the access is rejected, error code W#16#8090 results. 6 A5E03929122-AD, 05/2014

Parameter description update for TSEND_C and TRCV_C instructions The following table shows an update to Table 10-3 for the REQ, EN_R, and CONT parameter descriptions for the TSEND_C and TRCV_C instructions: Table 7 TSEND_C and TRCV_C data types for the parameters Parameter and type Data type Description REQ (TSEND_C) IN Bool REQ = 1 starts the TSEND_C send job on a rising edge with the connection described in the CONNECT parameter. (CONT = 1 is also required to establish and maintain the communication connection.) EN_R (TRCV_C) IN Bool When EN_R = 1, TRCV_C is ready to receive. The receive job is processed. (CONT = 1 is also required to establish and maintain the communication connection.) CONT IN Bool Controls the communication connection: 0: Disconnect the communication connection 1: Establish and maintain the communication connection When sending data (TSEND_C) (rising edge at the REQ parameter), the CONT parameter must have the value TRUE in order to establish or maintain a connection. When receiving data (TRCV_C) (rising edge at the EN_R parameter), the CONT parameter must have the value TRUE in order to establish or maintain a connection. Read access security level for the CPU Section 6.6.1 Access protection for the CPU incorrectly states that a password is required to change the CPU operating mode (RUN/STOP) for the Read access security level. You do not have to enter a password to change the CPU operating mode. Spare parts compatibility for communication modules The new communication modules (6ES7 2xx-xxx32-0XB0) replace existing communication modules (6ES7 2xx-xxx30-0XB0). The new modules provide spare parts compatibility. You can employ the revised communication module in place of existing modules without any changes. A5E03929122-AD, 05/2014 7

Behavior of RCV_PTP instruction Note the following correlation between the EN_R input and the message buffer of the RCV_PTP instruction: Input EN_R controls the copy of a received message to the BUFFER. When the EN_R input is TRUE and a message is available, the CPU transfers the message from the CM or CB to the BUFFER and updates the NDR, ERROR, STATUS and LENGTH outputs. When EN_R is FALSE, the CPU checks the CM or CB for messages and updates the NDR, ERROR and STATUS outputs, but does not transfer the message to the BUFFER. (Note that the default value of EN_R is FALSE.) The recommended practice is to set EN-R to TRUE and control execution of the RCV_PTP instruction with the EN input. Uploading program blocks from online CPU to offline project In section 6.8.1 "Copying elements of the project", the description of uploading program blocks from the online CPU to the offline project is incorrect. When you upload the program blocks, you do not upload the technology blocks or tags. To upload technology blocks, rightclick "Technology objects" in the project tree node and select "Upload from device (software)". To upload tag names, you must upload the entire PLC. Note also when uploading program blocks, you can upload all blocks or blocks individually. Configuring the SM 1278 4 x IO-Link Master The TIA Portal version in section 15.3.1 is incorrect. For the module integration, you need the Siemens engineering tool TIA Portal V13 or higher (not TIA Portal V12). 8 A5E03929122-AD, 05/2014

Number of asynchronous communication connections supported Overview of communication services The CPU supports the following communication services: Communication service Functionality Using PROFIBUS DP Using CM 1243-5 DP master module CM 1242-5 DP slave module Ethernet PG communication Commissioning, testing, diagnostics Yes No Yes HMI communication Operator control and monitoring Yes No Yes S7 communication Routing of PG functions Data exchange using configured connections For example, testing and diagnostics beyond network boundaries Yes No Yes No No No PROFIBUS DP Data exchange between master and slave Yes Yes No PROFINET IO Data exchange between I/O controllers and I/O devices No No Yes Web server Diagnostics No No Yes SNMP (Simple Network Management Protocol) Standard protocol for network diagnostics and parameterization No No Yes Open communication over TCP/IP Open communication over ISO on TCP Open communication over UDP Data exchange over Industrial Ethernet with TCP/IP protocol (with loadable FBs) Data exchange over Industrial Ethernet with ISO on TCP protocol(with loadable FBs) Data exchange over Industrial Ethernet with UDP protocol (with loadable FBs) No No Yes No No Yes No No Yes A5E03929122-AD, 05/2014 9

Available connections The CPU supports the following number of maximum simultaneous, asynchronous communication connections for PROFINET and PROFIBUS. The maximum number of connection resources allocated to each category are fixed; you cannot change the values: Based upon the allocated connection resources, the following number of connections per device are available: Programming terminal (PG) 4 (guaranteed to support 1 PG device) Human Machine Interface (HMI) 12 (guaranteed to support 3 HMI devices) GET/PUT server GET/PUT client Open User Communications Web server Maximum number of connection resources 3 8 8 30 (guaranteed to support 3 web browsers) For an example, the CPU has 4 available PG connection resources. Depending on the current PG functions in use, the PG might actually use 1, 2, 3, or 4 of the available connection resources. If one PG uses 1 connection resource and another PG uses 3 connection resources for their current functions, it is possible to use 2 PGs at one time; however, you are always guaranteed at least 1 PG. Another example is the number of HMIs, as shown in the figure below. HMIs have 12 available connection resources. Depending on what HMI type or model that you have and the HMI functions that you use, each HMI might actually use 1, 2, 3, or 4 of its available connection resources. Given the number of available connection resources being used, it may be possible to use more than 3 HMIs at one time. However, you are always guaranteed at least 3 HMIs. Example HMI 1 HMI 2 HMI 3 HMI 4 Total connection resources available Connection resources used 2 3 3 4 12 Note Web server (HTTP) connections: The CPU provides connections for multiple web browsers. The number of browsers that the CPU can simultaneously support depends upon how many connections a given web browser requests/utilizes. Note The Open User Communications, S7 connection, HMI, programming device, and Web server (HTTP) communication connections can utilize multiple connection resources based upon the features currently being used. SB 1231 AI 1 x 12 bit Table A-207, Analog inputs is incorrect. The common rejection value for SB 1231 AI x 12 bit is 40 db, DC to 60 Hz (not 400 db, DC to 60 Hz). In Table A-209, Wiring diagrams for the analog input SB, the note, 1 is further clarified as Connect "R" and "0+" for current applications. 10 A5E03929122-AD, 05/2014

TeleService modules The Teleservice module, TS Adapter IE Advanced (order number 6ES7 972-0EA00-0XA0) is available for use with the S7-1200. SM 1232, SM 1234, and SB 1232 analog output tables In the following tables, the microsecond specification is incorrect. It should be shown as "μs" (microseconds), not "μs". The tables affected are: A-146 SM 1232 Analog outputs A-153 SM 1234 Analog outputs A-212 SB 1232 Analog outputs Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG A5E03929122-AD, 05/2014 11