VirtualWisdom Performance Probes are VirtualWisdom Fibre Channel SAN Performance Probe

Similar documents
VirtualWisdom SAN Performance Probe Family Models: ProbeFC8-HD, ProbeFC8-HD48, and ProbeFC16-24

VirtualWisdom â ProbeNAS Brief

Cisco SAN Analytics and SAN Telemetry Streaming

Cisco Nexus 9500 Platform Switches for Cisco Application Centric Infrastructure

Cisco Nexus 9500 Platform Switches for Cisco Application Centric Infrastructure

GigaVUE-2404 // Data Sheet

Port Tapping Session 3 How to Survive the SAN Infrastructure Storm

Cisco Nexus 9500 Series Switches

Hybrid IT Infrastructure Management

Port Tapping Session 2 Race tune your infrastructure

Load Dynamix Enterprise 5.2

Meraki MS22 / MS42 Cloud Managed Gigabit PoE Switch Family

MS425 SERIES. 40G fiber aggregation switches designed for large enterprise and campus networks. Datasheet MS425 Series

Brocade ICX 6610 Switch

Installing the IPS 4345 and IPS 4360

Cisco Meraki MS400 Series Cloud-Managed Aggregation Switches

X1 X2. traditional security tools, allowing malware to propagate across the infrastructure. SPAN ports on the leaf and spine switches provide

CONNECTRIX DS-6500B SWITCHES

FlowDirector x 1G//10G SFP/SFP+ Ports Network Fabric Visibility Appliance

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Cisco UCS 6100 Series Fabric Interconnects

Virtual Instruments Application Aware Infrastructure Performance Management

Cisco UCS 6324 Fabric Interconnect

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

CONNECTRIX MDS-9132T, MDS-9396S AND MDS-9148S SWITCHES

Over 70% of servers within a data center are not connected to Fibre Channel SANs for any of the following reasons:

Dell SC7020 Storage Controller Getting Started Guide

TECHNICAL SPECIFICATION. Brocade 6510 Switch Technical Specifications

GigaVUE-420 // Data Sheet

CONNECTRIX MDS-9250I SWITCH

SUN BLADE 6000 VIRTUALIZED 40 GbE NETWORK EXPRESS MODULE

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

NST6000 UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment

QuickSpecs. Models HP TippingPoint S8010F Next Generation Firewall Appliance

Artico NAS Storage Appliance Site Planning Guide

Ixia Net Optics ilink Agg xstream

FlowDirector x 1G/2.5G/10G SFP/SFP+ and 4x 40Gb QSFP+ Ports Network Fabric Visibility Appliance

16x16 Modular Matrix Switch VM1600

MS Cloud Managed Gigabit Switch Series

VIRTUAL EDGE PLATFORM 4600 Next Generation Access

Ixia xbalancer. A Purpose-Built Load Balancer for 10G Networks. The Load Balancing Solution DATA SHEET. Highlights

MS120 Switches. Cloud-managed access switches with 1G SFP uplinks, designed for branch deployments. Datasheet MS120 Switches

SUN BLADE 6000 CHASSIS

Cisco Firepower 9300 Security Appliance

EMC ISILON X-SERIES. Specifications. EMC Isilon X210. EMC Isilon X410 ARCHITECTURE

Cisco Nexus 9300 Series Leaf Switches for Cisco ACI. Application Centric Infrastructure

ISILON X-SERIES. Isilon X210. Isilon X410 ARCHITECTURE SPECIFICATION SHEET Dell Inc. or its subsidiaries.

Pinnacle 3 SmartEnterprise

Summit Virtual Chassis Design and Installation Guide

IBM TotalStorage SAN Switch F08

SEVONE DATA APPLIANCE FOR EUE

Gmux Modular TDMoIP Gateway FEATURES

IBM TotalStorage SAN Switch F32

McAfee Network Security Platform

Cisco MDS 9250i Multiservice Fabric Switch Overview. Introduction CHAPTER

GigaVUE-420 Specifications

McAfee Network Security Platform

Observer Probe Family

The Genesis HyperMDC is a scalable metadata cluster designed for ease-of-use and quick deployment.

Cisco Mobility Services Engine: An Open, Appliance-Based Platform for Delivering Mobility Services

GigaStor Upgradeable 2U. User Guide

ORACLE DATABASE APPLIANCE X3 2

DELL POWERVAULT NX3500. A Dell Technical Guide Version 1.0

Savant Host: SVR-4500S

IBM System Storage SAN40B-4

Data Sheet. OceanStor SNS2624/SNS3664 FC Storage Switches. Product Features HIGHLIGHTS. OceanStor SNS2624/SNS3664 FC Storage Switches

CSU 0111 Compute Sled Unit

Cisco UCS C200 M2 High-Density Rack-Mount Server

TECHNICAL SPECIFICATION. Brocade G620 Technical Specifications

Security-hardened Appliances for Network Infrastructure Identification

Cisco Nexus 7000 Series.

CONNECTRIX ED-DCX8510B ENTERPRISE DIRECTORS

Cisco MCS 7845-H1 Unified CallManager Appliance

Oracle Database Appliance X6-2S / X6-2M

IBM TotalStorage Storage Switch L10

The power of centralized computing at your fingertips

SEVONE END USER EXPERIENCE

SINGLEstream Link Aggregation Tap (SS-100)

EMC ISILON S-SERIES. Specifications. EMC Isilon S200. EMC Isilon S210 ARCHITECTURE

32 x 32 Modular Matrix Switch

Cisco Nexus 9500 R-Series

Oracle Database Appliance X6-2L

G3-GSP-2P40-8TSSD. Parts list. G3-GSP-2P40-8TSSD technical specifications. About G3-GSP-2P40-8TSSD

Genesis HyperMDC 200D

Savant Host Controller: SVR-4100

EMC ISILON X-SERIES. Specifications. EMC Isilon X200. EMC Isilon X400. EMC Isilon X410 ARCHITECTURE

G3-GSP-2P100-8TSSD Hardware Installation

MS Cloud Managed Gigabit Switch Series

ngenius 5100 Packet Flow Switch

IBM Europe Announcement ZG , dated February 13, 2007

MS120-8 Compact Switch

Cisco MCS 7815-I2 Unified CallManager Appliance

PE2G4SFPI35L Quad Port SFP Gigabit Ethernet PCI Express Server Adapter Intel i350am4 Based

NX 9500 INTEGRATED SERVICES PLATFORM SERIES FOR THE PRIVATE CLOUD

ngenius 5010 Packet Flow Switch

ExtremeWireless WiNG NX 9500

QuickSpecs. HPE Altoline 6921 Switch Series. Overview. HPE Altoline 6921 Switch Series

Dell PowerEdge C410x. Technical Guide

Cisco Nexus 7000 Switches Second-Generation Supervisor Modules Data Sheet

Apex Lynx DATASHEET. DS-1030-E 1 of 5

Transcription:

Data Sheet VirtualWisdom Performance Probes for line-rate wire data monitoring VirtualWisdom Fibre Channel SAN Performance Probe VirtualWisdom Performance Probes are VirtualWisdom Fibre Channel SAN Performance Probe hardware devices that are part of the industry s most comprehensive infrastructure performance monitoring and analytics platform, VirtualWisdom. Monitor every application conversation from the initiator to the target LUN Hardware Probes Enable High Fidelity Monitoring channel in a 1U chassis appliance, reporting at 1 sec resolution. Storage arrays in your SAN can collect sub-second visibility into application per-second granularity. Doing so would conversations using metrics for R/W impact their primary function which is to latency including Exchange provide on-demand storage capacity to Completion Time (ECT), R/W ratios applications. Offloading the monitoring and R/W IO size. the storage array to stay focused on its Identify credit starvation by keeping track of buffer credits and the primary function serving data. number of unacknowledged frames An event that occurs for a few milliseconds that can be in flight between a source but impacts the SLA of your business- and destination critical application would be lost to software monitoring solutions as they rely As VirtualWisdom Performance Probes work at the protocol level, the solution is Identify low level physical layer errors as well as higher level SCSI errors. on sampling. Benefit from histograms that provide statistics, but they cannot monitor over a function to a dedicated appliance allows Up to 24 ports of 4/8/16G Fibre Identify delays at the host and storage level Leverage over 400 metrics gathered agnostic to the storage or SAN vendor. and summarized at 1 sec, 10 sec and 1 This enables a consistent single pane- min intervals. of-glass view across multi-vendor SAN An application conversation is a and storage to identify root-cause of discrete communication between an infrastructure issues impacting your initiator (host), the target (storage application SLA. port) and the LUN number being accessed. VirtualWisdom tracks

every conversation by taking 31 measurements per conversation per second. A single Performance Probe can monitor 19,200 unique ITLs per second. Get to root-cause on issues that occur for only a few seconds Leverage our machine learning based analytics which are designed to proactively optimize and prevent problems: Queue Solver to troubleshoot flow control issues and understand the impact of different I/O queue depths across hosts. Queue depth refers to the number of I/O requests (SCSI commands) that can be queued at one time. Storage Port Balancer to improve application performance by optimizing the load on storage ports on your Fibre Channel SAN attached storage. Trend Matcher to get to root-cause of problems created by an entity that is several hops away from the location of an alarm. This level of machine learning based analytics is needed for cross domain correlation and actionable recommendations. This is because the traffic flow between entities could comprise thousands of micro transactions per second which converge and diverge at different nodes. Deployed with passive TAPs which ensure that every I/O is monitored with zero performance impact on the infrastructure being monitored. Connectivity SAN Link Interface: Connectivity to the TAP monitor outputs is provided by way of field-replaceable small form factor pluggable plus (SFP+) optical transceivers. SAN Link Capacity: ProbeFC-16G SAN Performance Probe monitors up to 12 or 24 concurrent Fibre Channel SAN Links operating at 4/8/16 Gbps speeds. VirtualWisdom Platform Connectivity: SAN Performance Probes connect to the VirtualWisdom Platform Appliance and transfer calculated SAN metrics for persistent storage, analysis, and display. Deployment and Serviceability No physical or remote console access. Firmware maintenance, device configuration, and operational monitoring are all performed remotely via VirtualWisdom. Initial configuration and ongoing management are performed through a standard browser interface via a dedicated and directly connected Ethernet port (not a networked port). Redundant hot-swappable power supply modules for high availability. Field-replaceable and reversible cooling fan modules support both front-to-rear and rear-to-front airflow.

Safety and Emissions Compliance Safety UL/EN/IEC 60950-1 Restriction of Hazardous Substances (RoHS) Emissions United States: FCC Part 15, Subpart B (Class A Device) Canada: ICES Europe: EN 55022 Korean: KN 22 Environmental Temperature Operating: +10 to +35 C (50 to +95 F) Max gradation 10 per hour Non-Operating: -20 to +80 C, (-4 F to 176 F) max gradation 20 C per hour Humidity Operating: 20% to 80% non-condensing, Non-Operating: 5% to 95% noncondensing, Mechanical ProbeFC-16G-12 ProbeFC-16G-24 Height 1U, 1.75 in (4.45 cm) 1U, 1.75 in (4.45 cm) Width 17.2 in. (43.7 cm) 17.2 in. (43.7 cm) Depth 28.2 in. (71.6 cm). Maximum fixed projection from front face 0.75 in (1.9 cm), from rear face 1.0 in (2.5 cm). Optional cable manager projects 4.5 in (11.4 cm) from front face. 28.2 in. (71.6 cm). Maximum fixed projection from front face 0.75 in (1.9 cm), from rear face 1.0 in (2.5 cm). Optional cable manager projects 4.5 in (11.4 cm) from front face. Weight Rack Mounting 42 lbs. (19 kg) including rack rails and cable management system Sliding rack rails support 4 post racks with square, round, or tapped holes with rail-to-rail depths of 26.5 in (67.31 cm) to 36 in (91.4 cm.) 1U, 25 in (61 cm) deep shelf kit available for alternate rack deployments. 45 lbs. (20.4 kg) including rack rails and cable management system Sliding rack rails support 4 post racks with square, round, or tapped holes with rail-to-rail depths of 26.5 in (67.31 cm) to 36 in (91.4 cm.) 1U, 25 in (61 cm) deep shelf kit available for alternate rack deployments.

VirtualWisdom NAS Performance Probe VirtualWisdom NAS Performance Probe Monitor every application conversation over 16 ports of 10 GbE line rate in a 2U form factor with support for SMB 2.0, NFSv3, iscsi over TCP/IPv4 Identify why a storage array whose front-end CPU is operating at close to 100% is delivering only a fraction of the performance it can deliver on a 10GbE link Identify root cause of metadata and login storms Identify a noisy neighbor or rogue client impacting the performance of a business-critical application. This could be a legacy application migrated from bare-metal and local storage to a virtual machine (VM) with networked storage but using the same legacy logic to crawl the shared resource Identify top N SMB or NFS conversations by input/output operations per second (IOPS) Identify root cause of SMB or NFS hosts complaining about slow reads Identify network flow control issues by monitoring for Ethernet Pause Frames Identify performance issues caused at the storage or network level across multivendor SAN fabrics and storage systems Identify performance bottlenecks anywhere from compute down to NFS/SMB shares or iscsi LUNs using 373 NFS metrics, 210 SMB metrics, 345 iscsi metrics Support for link aggregation and IEEE802.1Q VLAN Metrics collected in different categories, for example, SMB metrics come under 3 categories: Health (metrics such as Read/write errors, file create errors) Utilization (metrics such as IOPs and total byte rate) Performance (metrics such as read/ write completion times, TCP window closes, pause frames) Best-practice alarms such as seasonal trend deviation alarms which fire whenever there is a deviation from your normal business cycle Deployed with passive TAPs which ensure that every I/O is monitored with zero impact on the infrastructure being monitored Connectivity Link Interface: Connectivity to the TAP monitor outputs is provided via fieldreplaceable small form factor pluggable plus (SFP+) optical transceivers. Link Capacity: The NAS Performance Probe comes with 16 concurrent GigE Links operating at 10 GbE speeds or 40GbE speeds with Gigamon integration support for GigaVUE and Gigamon Traffic Aggregators.

VirtualWisdom Platform Connectivity: The Performance Probe connects to the VirtualWisdom Platform Appliance via Gigabit Ethernet to transfer calculated SMB 2.0, NFSv3, iscsi over TCP/IPv4 metrics for persistent storage, analysis, and display. Deployment and Serviceability No physical or remote console access. Firmware maintenance, device configuration, and operational monitoring are all performed remotely via VirtualWisdom. Initial configuration and ongoing management are performed through a standard browser interface via a dedicated and directly connected Ethernet port (not a networked port). Redundant hot-swappable power supply modules for high availability. Field-replaceable and reversible cooling fan modules support both front-to-rear and rear-to-front airflow. Emissions United States: FCC Part 15, Subpart B (Class A Device) Canada: ICES Europe: EN 55022 Korean: KN 22 Environmental Temperature Operating: +10 to +35 C (50 to +95 F), max gradation 10 per hour Non-Operating: -20 to +80 C, (-4 F to 176 F) max gradation 20 C per hour Humidity Operating: 20% to 80% non-condensing, Non-Operating: 5% to 95% noncondensing, Safety and Emission Compliance Safety UL/EN/IEC 60950-1 Restriction of Hazardous Substances (RoHS)

Mechanical ProbeFC-16G-12 Height Width Depth Weight Rack Mounting 2U, 3.5 In. (8.9 cm) 17.2 in. (43.7 cm) 28.2 in. (71.6 cm) Maximum fixed projection from front face 0.75 in (1.9 cm), from rear face 1.0 in (2.5 cm). Optional cable manager projects 4.5 in (11.4 cm) from front face. 55 lbs (24.9 kg) including rack rails and cable management system Sliding rack rails support 4 post racks with square, round, or tapped holes with rail-to-rail depths of 26.5 in (67.31 cm) to 36 in (91.4 cm.) 1U, 24 in (61 cm) deep shelf kit available for alternate rack deployments. Electrical VirtualWisdom NAS Performance Probe Input Voltage Input Frequency Input Current Inrush Current Operating Power 100-240V AC 50-60 Hz 12/6A (RMS) @115/230V 15/30A (max) @115/230V 750W (max) 10/2018 Virtual Instruments. All rights reserved. Features and specifications are subject to change without notice, WorkloadWisdom. VirtualWisdom, Virtual Instruments, are trademarks or registered trademarks in the United States and/or in other countries. All other trademarks and trade names are the property of their respective holders.